Loading...
HomeMy WebLinkAboutECS 11-22-2019 - Missing Field Values - Missing Field ValuesLETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As RequestedFor Your Use 11/22/2019 Grapevine Station North-Phase 1 801 E. Northwest Hwy, Grapevine, TX 1045 Mr. A.L. Burtin Westwood Real Estate Group 1000 Texan Trail Ste. 200 Grapvine, TX 76051 36 CONCRETE, GROUT, AND MORTAR TESTS4050 Sandshell Drive, Suite 500 Fort Worth, TX 76137 (682) 350-2250 [Phone] (817) 847-8616 [Fax] X X XX Tarrant County ECS Southwest, LLP CC:Westwood Group Development No. 11 - Randy Sawey Les Daigh Excavating and Demolition - Les Daigh City of Grapevine - Donald Dixson City of Grapevine - Scott Cannon Westwood Group Development No. 11 - Taylor Hazlewood Acadia Capital Group - Brad Catlett Siddharth Neekhra Principal Engineer Tim Tarbutton Office Manager NOV 22 2019By: 1. This report (and any attachments) shall not be reproduced except in full without prior written approval of ECS. 2. The information in this report relates only to the sample test specimens obtained on the report date. 4. Non-conforming test results will be recorded for future resolution. Disclaimer 3. The primary purpose of this report is to present the laboratory test results for the indicated sample test specimens. For a full compliance evaluation of construction events that the specimens represent, this test report must be used in conjunction with the related field report. 5. Test results that do not meet the required strength levels at the specified ages are marked "LOW TEST RESULTS ". Transmittal Page 1/2 Project: Location:Report No.: Cast Date: Grapevine Station North-Phase 1 801 E. Northwest Hwy, Grapevine, TX 36 10/18/2019 1045Project : Concrete Cylinders Strength Report Set Designation:A 4050 Sandshell Drive, Suite 500 Fort Worth, TX 76137 (682) 350-2250 [Phone] (817) 847-8616 [Fax] ECS Southwest, LLP Acceptance Age:28 Days 4000 psiDesign Strength: Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Westwood Group Development No. 11 - Clint Whitworth Engineering - Russell W hitworth Lot 4 / Lot 5 Approach Charley's Concrete 10 578969 4518 4000 psi 01:45 PM -Added W ater: Approx. Location Set Represents: Lot 4 / Lot 5 Approach Placement Information Supplier Information (If ReadyMix) Sample #Test Date Test Age Curing Type (F/L) Breaking Load Rounded Compr. Str. (psi) Brk Type Date to Lab Field Test Data Avg. CrossSectional Area (in.-sq) Cap Type Average Computed Diameter (in.)(lbs) Air Content:Air Temperature:Concrete Temperature: Time Sampled:Slump/Slump Flow:Mitchell R. Mantzke 02:25 PM 3.50 in. 3.80% (P) Performed by: 71° F73° F Fresh Unit W eight:- 36704608063-1045-36-1 10/25/2019 7 Lab 4.00 2 U 10/19/201912.56 47706000063-1045-36-2 11/15/2019 28 Lab 4.00 3 U 10/19/201912.56 50106291263-1045-36-3 11/15/2019 28 Lab 4.00 3 U 10/19/201912.56 51106421363-1045-36-4 11/15/2019 28 Lab 4.00 3 U 10/19/201912.56 63-1045-36-5 12/13/2019 56 Lab 10/19/2019 Sampling in accordance with (iaw) ASTM C172 except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617, and cylinders denoted with Cap Type N (none) meet the planeness requirements of ASTM C39 and are tested without caps. Break Types are classified as: Type 1,2,3,4,5 or 6 iaw C39. Initial Curing Conditions Curing Box Insulated Heated Cooled Remarks: Final Review By: Ice Other Curing Tank Print Date:11/22/2019 EWood CCBRv265 Transmittal Page 2/2