Loading...
HomeMy WebLinkAboutCU2012-06-F*-1A "t S k PART 1. APPLICANT INFORMATION CITY OFGRAPEVINE CONDITIONAL USE APPLICATION . in L Applicant Name: Pacheco Koch Consulting Engineers, Inc. Contact: Matthew A. Lucas Applicant Address: 8350 N. Central Expressway, Suite 1000 City/State/Zip Dallas, Texas 75206 Phone No. 972-235-3031 Fax No. 972-235-9544 Email Address rnlucas pkce.com Mobile Phone 214-202-5994 Applicant's interest in subject property Civil Engineer Consultant PART 2. PROPERTY INFORMATION Street Address of subject property 11401 W. State Highway 114 Legal Description: Lot [1R Blockf 1 Addition Regency Center Legal description of subject property (metes & bounds must be described on 8 1/2" x 11" sheet Size of subject property: acres6.842 square footage 298,031 SF Present zoning classificationCC Community Commercial Distric Proposed use of property Automotive sales and service Zoning ordinance provision requiring a conditional use Section 25 PART 3. PROPERTY OWNER INFORMATION Property Owner IDDVTDevelopment, LP Contact: Missy Monier (972-536-2906) Prop Owner Address 1550 E. Missouri, Suite 300 City/State/ZipPhoenix, Arizona 85014 Phone No. 602-230-1051 Fax No. 602-200-7560 Submit a letter describing the proposed conditional use and note the request on the site plan document In the same letter, describe or show on the site plan, and conditional requirements or conditions imposed upon the particular conditional use by applicable district regulations (example; buffer yards, distance between users) in the same letter, describe whether the proposed conditional use will, or will not cause substantial harm to the value, use, or enjoyment of otherproperty in the neighborhood. Also, describe how the proposed conditional use will add to the value, use or enjoyment of other property in the neighborhood. Application of site plan approval (Section 47, see attached Form "B"). The site plan submission shall meet the requirements of Section 47, Site Plan Requireme r _C) All conditional use and conditional use applications are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date. All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled. Any changes to a site plan (no matter how minor or major) approved with a conditional use or conditional use permit can only be approved by city council through the public hearing process. I have read and understand all the requirements as set forth by the application for conditional use or conditional use permit and acknowledge that all requirements of this application have been met at the time of submittal. PART 4. SIGNATURE TO AUTHORIZE CONDITIONAL USE REQUEST AND PLACE A CONDITIONAL USE REQUEST SIGN ON THE SUBJECT PROPERTY - i _ l f 2— Print Applicant's Name Applicant's Signature The State of County of Before me (notary) on this day personally appeared (applicant) fl 1 known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office thisF3 day of ,1. A.D. - ---------- SAUNA MARTINEZ ♦� MY COMMISSION EXPIRESL '/u ) i OCTOBER "f 20. 2013 -• Notary In and For State of jkws Print Property Owner's Name Propert wner's Signature The State of County of DqLK Before me (notary) on this day personally appeared (applicant) J14485 -TWW- known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office this F day of A.D. pueeq MELISSA TARVER Notary Public, state of Texas My Commission Expires M,cy 02, 2012 Notary In and For State of X JF PART 1. APPLICANT INFORMATION Applicant Name: (Pacheco Koch Consulting Engineers, Inc. Cu is -off CITY OFCRAPEVINE SITE PLAN APPLICATION Contact: Matthew A. Lucas Applicant Address: 18350 N. Central Expressway, Suite 1000 City/State/Zip Dallas, Texas 75206 Phone No. 972-235-3031 Fax No. 972-235-9544 Email Address miucas pkce.com Mobile Phone 214-202-5994 Applicant's interest in subject property I Civil Engineer Consultant PART 2. PROPERTY INFORMATION Street Address of subject property 11401 W. State Highway 114 Legal Description: Lot 1 R Block Addition Regency Center Legal description of subject property (metes & bounds must be described on 8 1/2" x 11" sheet Size of subject property: acres 6.842 Present zoning classification CC Community Commercial Distric Proposed use of property (Automotive sales and service Zoning ordinance provision requiring a conditional use Section 25 PART 3. PROPERTY OWNER INFORMATION Property Owner I DDVT Development, LP Contact: Missy Monier (972-536-2906) Prop Owner Address1550 E. Missouri, Suite 300 City/State/Zip Phoenix, Arizona 85014 Phone No. 602-230-10510 Fax No. 602-200-7560 Attach a final plat, or replat, of the approved subdivision by city council showing property boundary lines, dimensions, easements, roadways, rail lines, and public rights -of way crossing and adjacent to the tract ( 1 blueline copy) VIf a master development plan is required, attach a statement showing the proposed use substantially conforms to the master development plan. J Submit a site plan showing all information required by Section 47.E., Site Plan review requirements (see attached requirements). Provide all required information demonstrating compliance with all conditions imposed on any conditional use, site plan zoning, or conditional use zoning. All site plans must conform to the approved concept plan. Any changes to a site plan, approved with a conditional use or a conditional use, can only be approved by city council through the public hearing process. PART 4. SIGNATURE TO AUTHORIZE FILING OF A SITE PLAN Print Applicant's Name Applicant's Sign re The State of County of. Before me (notary)rat, yt_; 6 on this day personally appeared (applicant) �� known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (S _— _MW NA4, f office this Sf 3p �'"uPi i SAUNA MARTINEZ is _* MY COMMISSION EXPIRES F�,OCTOBER 20. 2013 Nvws Yi*ym Print Property Owner's Name The State of County of I_ _ 1771 day of1t1' A.D. Notary I Before me (notary) I i on this day personally appeared (applicant) known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office thiF i *- sday of A.D. ❑y Poo moo:?R ::;c�` MELISSA TARVER Notary In and For State of Notary Public, State of Texas My Commission Expires ''•'.iEoi�E:o May 02, 2012 ruor�. 1! l e r..J' �, i ACKNOWLEDGEMENT C LA pL -o6 All Conditional Use and Special Use Applications are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date. All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled. Any changes to a site plan (no matter how minor or major) approved with a conditional use or a special use permit can only be approved by city council through the public hearing process. Any application for a change in zoning or for an amendment to the zoning ordinance shall have, from the date of submittal, a period of four months to request and be scheduled on an agenda before the Planning and Zoning Commission and City Council. If after said period of four months an application has not been scheduled before the Commission and Council said application shall be considered withdrawn, with forfeiture of all filing fees. The application, along with the required filing fee may be resubmitted any time thereafter for reconsideration. Delays in scheduling applications before the Planning and Zoning Commission and City Council created by city staff shall not be considered a part of the four month period. I have read and understand all of the requirements as set forth by the application for conditional use or special use permit and acknowledge that all requirements of this application have been met at the time of submittal. Signature of Applicant Date Signature of Property Owner Date r - L PLATTING VERIFICATION This verification statement must be signed prior To the submittal of this conditional use application It has been determined that the property described below does require platting or replatting and the applicant has been instructed on this procedure. It has been determined that the property described below is currently platted or does not require platting or replatting at this time. Address of subject property 1401 W. State Highway 114 Legal description of subject property Lot 1R, Block I, ReaencY Center i rks Department D to This form must be signed by the public works department and submitted along with a completed application to the planning and zoning department 1 inch = 300 feet 0 CU 12-06 Texas Nissan CU12-06 TEXAS NISSAN OF GRAPEVINE FEBRUARY 19, 2012 1401 WEST STATE HIGHWAY 114 LOT 1R, BLOCK 1, REGENCY CENTER ADDITION TEXAS NISSAN OF GRAPEVINE 1. Please add case number CU12-06 to the first note and to the signature block of each sheet. 2. Please highlight the approximate location of the one displaced employee parking space. Please provide an employee count table/chart beneath the notes which provides the total number of employees and the approximate shifts/times on site. 3. Please dimension the distance of the proposed expansion area to the east property line on the overall site plan and landscape plan and cloud all proposed changes on the overall site plan. 4. The Fire Department requires the sprinkler system to be extended into the expansion area. Please contact the City of Grapevine Fire Deputy Chief (Randie Frisinger) at (817) 410-3482 to discuss fire prevention requirements for the proposed expansion. 5. Please note Building Inspections will require project data sheets for the proposed expansion when a building permit application is submitted. Please contact Don Ellison or Allen Hunt at (817) 410-3165 for any question regarding this requirement. 6. For verification purposes please email a PDF of the final sheets on or before Monday, February 27th and prior reproducing the final copies. The above comments must be reflected in the revised submittal, which are due by Tuesday, February 28th for the March 7th public hearing. Please submit the revised documents to the Department of Development Services at 200 South Main Street. The revised submittal shall include: five (5) folded blackline copies of each sheet, (minimum size 22" x 34") fiver (5) reduced sorted (collated sets) copies at 11" x 17" stapled and z - folded (fold the right edge to the left edge and then fold the right edge in half to form a z -fold). If these revisions are made and submitted at the correct time, you will be scheduled for the next available agenda. If you have any questions please contact Albert L. Triplett, Jr. at (817) 410-3155. O: \ZCU\CU 12-06.1. doc S ATIS MR I Ore VIM i` L. Rei CC; ❑ Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle • Comments: (2/28/2012) Albert Triplett - Texas Nissan Waiting Room CUP Page 1 From: "Carlos Fernandez" <carlos cfaarchitects.com> To: "Albert Triplett' <Atriplett@grapevinetexas.gov> Date: 2/28/2012 1:55 PM Subject: Texas Nissan Waiting Room CUP Attachments: clarification TEXAS NISSAN WAITING CUP_ A-1 SITE PLAN 2-28-12.pdf; TEXAS NISSAN WAITING CUP_ A-1 SITE PLAN 2-28-12.pdf Albert: Please see attached CUP Site Plan and a parking clarification Site Plan At the East side double 20 count Display Parking, we have gained 2 Display spaces and lost 3 Employee spaces (Northeast). At the East side between the Service Building and the East property line, we have gained 2 Employee spaces (Southeast). The previous change of the Ione Employee space at the West side of the New Car Building is back to the original Customer space (no change). To tally the space change: +2 Display spaces (Northeast) -3 Employee spaces (Northeast) +2 Employee spaces (Southeast) +1 Space gained overall or -1 Employee space +2 Display spaces -------------------------------- _ +1 Space gained overall Thanks, Carlos Fernandez p 972-650-1764 f 972-650-1783 580 Decker Drive, Suite 270 Irving, Texas 75062 [-(3/-2&1 2) Albert Triplett - Re- Texas Nissan Waiting Room CUP Page 1 From: "Carlos Fernandez" <carlos cfaarchitects.com> To: "Albert Triplett" <Atriplett@grapevinetexas.gov> Date: 3/2/2012 9:39 AM Subject: Re: Texas Nissan Waiting Room CUP Albert, The new waiting area will be replacing the existing waiting room, the existing waiting will be re -designed into one office and a new Men's restroom. The new waiting room contains 1,055 SF as shown on the Site Plan. Thanks, Carlos Fernandez p 972-650-1764 f 972-650-1783 580 Decker Drive, Suite 270 Irving, Texas 75062 ----- Original Message ----- From: "Albert Triplett" <Atriplett@grapevinetexas.gov> To: "Carlos Fernandez" <carlos cfaarchitects.com> Sent: Friday, March 02, 2012 8:48 AM Subject: Re: Texas Nissan Waiting Room CUP Good morning Mr. Fernandez, can you please tell me if the expanded waiting area is replacing an existing waiting area or an expansion to an existing waiting area and what the total square foot to the waiting area will be? Thank you. Albert L. Triplett, Jr. Planner II City of Grapevine Development Services 200 S. Main Street Grapevine, Texas 76051 P.O. Box 95104 Grapevine, Texas 76099 ph# 817.410.3155 fx# 817.410.3018 Atriplett@grapevinetexas.gov www.grapevinetexas.gov >>> "Carlos Fernandez" <carlos cfaarchitects.com> 2/28/2012 1:55 PM >>> Albert: Please see attached CUP Site Plan and a parking clarification Site Plan. At the East side double 20 count Display Parking, we have gained 2 Display spaces and lost 3 Employee spaces (Northeast). At the East side between the Service Building and the East property line, we have gained 2 Employee spaces (Southeast). The previous change of the Ione Employee space at the West side of the New TO: SITE PLAN REVIEW COMMITTEE MEMBERS DATE: MARCH 7, 2012 SUBJECT: CONDITIONAL USE REQUEST CU12-06; LOT 1R, BLOCK 1, REGENCY CENTER ADDITION RECOMMENDATION Staff recommends the Site Plan Review Committee consider the proposed changes to Conditional Use Request CU08-16 (Ord. 08-35) approved at the July 15, 2008 meeting for an automotive dealership with sales and service of new and used vehicles, specifically to allow a 1,055 -square foot expansion to the service department and parts building and take any other action necessary. BACKGROUND INFORMATIO Originally, Conditional Use Request CU99-72 (Ord. 99-184) was approved at the December 21, 1999 meeting to allow for the development of an automotive dealership (Don Davis Jeep/Chrysler) with sales and service of new and used vehicles along with a 18,950 square foot service building and a 40 -foot pole sign. The Site Plan Review Committee at their July 25, 2006 meeting approved Conditional Use Request CU06-28 (Texas Nissan of Grapevine) to replace a 40 -foot pole sign with a 35-foot,150-square foot pole sign. At the September 18, 2007 meeting Conditional Use Request CU07-26 (Ord.07-53) approved a 1,964 -square foot expansion to the new car sales building which was never constructed. Conditional Use Request CU08-16 (Ord. 08-35) was approved at the July 15, 2008 meeting to allow for a 6,112 -square foot addition to the new car sales building, a 1,079 -square foot addition to the used car sales building and the addition of a new 2,040 -square foot car wash which were never constructed. On August 3, 2011, the Site Plan Review Committee approved Conditional Use Request CU11-12 on the subject site, specifically to allow a 5,329 -square foot expansion to the new car sales building, a 1,537 -square foot expansion to the pre- owned car sales building and the addition of a new 1,871 -square foot car wash. Two landscaped areas totaling 1,154 -square feet were added adjacent to the northeast and northwest quadrants of the subject site to mitigate displaced landscaping adjacent to the new car sales building. On December 11, 2011, the Site Plan Review Committee approved Conditional Use Request CU11-33 on the subject site, specifically to allow a 4,655 -square foot expansion to the service department and parts building, resulting in an enlargement to the service department and parts building to 24,150 -square feet. A security fence was 0AZCU\CU 12-06.4sprc added adjacent to the car wash and an above ground fuel tank was relocated. To accommodate the expansion, total available parking was reduced from 491 spaces to 468 spaces. With this request the applicant proposes a 1,055 -square foot expansion to the service department and parts building for a customer waiting room. The proposed addition will enlarge the service department and parts building to 25,205 -square feet. A chain link gate is being added between the car wash and the proposed expansion area and an existing above ground gas tank is being relocated to accommodate the proposed expansion. The proposed changes to the subject site will result in an increase of one (1) parking space. The total parking provided of 469 spaces exceeds the minimum number of 150 required parking spaces for the use on the subject site. /at 0AZCU\CU 12-06.4sprc March 16, 2012 Pacheco Koch Consulting Engineers Matthew Lucas 8350 N Central Expressway #1000 Dallas, TX 75206 RE: GRAPEVINE FILE #CU12-06 Mr. Lucas, This letter is to verify that your request for a conditional use permit located at 1401 West State Highway 114 and platted as Lot 1 R, Block 1, Regency Center Addition, to amend the previously approved site plan of CU08-16 (Ord. 08-35) for an automotive dealership with sales and service of new and used vehicles, specifically to allow a 1,055 -square foot expansion to the service department and parts building was approved by the Site Plan Review Committee on March 7, 2012. A copy of the approved site plan is enclosed. Any changes to a site plan approved with a conditional use or a special use (no matter how minor or major) can only be approved by city council through the public hearing process. No Conditional Use Permit shall be valid for a period longer than one (1) year from the date on which the City Council grants the Conditional Use, unless within such one (1) year period: (1) a Building Permit is obtained and the erection or alteration of a structure is started, or (2) an Occupancy Permit is obtained and a use commenced. The City Council may grant one additional extension not exceeding one (1) year, upon written application, without notice or hearing. No additional extension shall be granted without complying with the notice and hearing requirements for an initial application for a Conditional Use Permit. Please do not hesitate to contact us if we may be of further assistance (817)410-3155. Sinc rely, Susan Batte Planning Technician The City of Grapevine - P.O. Box 95104 - Grapevine, Texas 76099 ® (817) 410-3154 Fax (817) 410-3018 - www.grapevinetexas.gov Cula-off 1401 W. State Hwy 114 Grapevine, Texas Lot 1 R, Block 1, Regency Center Addition BEGINNING, at a 1/2 -inch iron rod found in the southwesterly right-of-way line of State Highway No. 114 (a variable width right-of-way); said point being the east corner of Lot 2R, Block 1, Regency Center, an addition to the City of Grapevine according to the plat recorded in Cabinet A, Slide 7527 of said Plat Records; THENCE, South 45 degrees, 01 minutes, 35 seconds East, along the southwest line of said State Highway No. 114, a distance of 561.24 feet to a 1/2 -inch iron rod with "RPLS 1967' cap found for corner; said point being the north corner of Lot 1A, Block 1A, Durant Addition, an addition to the City of Grapevine according to the plat recorded in Cabinet A, Slide 12704 of said Plat Records; THENCE, South 44 degrees, 59 minutes, 39 seconds West, departing the said southwest line of State Highway No. 114, along the northwest line of said Lot 1A, a distance of 547.02 feet to a 1/2 - inch iron rod with "PACHECO KOCH" cap found for corner; said point being the west corner of said Lot 1 A; THENCE, North 41 degrees, 46 minutes, 44 seconds West, departing the said northwest line of Lot 1A, a distance of 561.98 feet to a 5/8 -inch iron rod with "Sempco" cap found for corner; said point being the west corner of Lot 4R, Block 1 of last mentioned Regency Center; THENCE, North 44 degrees, 58 minutes, 39 seconds East, along the southeast line of said Lot 4R, passing at a distance of 141.63 feet a 1/2 -inch iron rod with "Area Surveying" cap found for the southernmost southeast corner of said Lot 4R and the southernmost southwest corner of said Lot 2R, continuing in all a total distance of 515.18 feet to the POINT OF BEGINNING; CONTAINING: 298,031 square feet or 6.842 acres of land, more or less. Pacheco Koch GALLAS w FORT CrR F TT, - February 5, 2012 PK No.: 2279-11.303 Mr. Albert Triplett, Jr. CITY OF GRAPEVINE Development Services 200 S. Main Street P.O. Box 95104 Grapevine, Texas 76099 Re: CONDITIONAL USE REQUEST Texas Nissan of Grapevine - Service Building Addition (Waiting Room) Lot 1R, Block 1, Regency Addition Grapevine, Texas Dear Mr. Triplett, This letter is to notify you of a request for Conditional Use of Lot 1 R, Block 1, Regency Center Addition to amend the previously approved site plan of CUII-33, CUII-12 SPRC, CU08-16 (Ordinance 2008-35) for an existing automotive dealership with sales and service of new and used vehicles. The intent of the CUP request is specifically to allow a 1,055 -square foot expansion to the service building. The proposed Conditional Use will not cause substantial harm to the value, use or enjoyment of other property in the neighborhood, as it is an addition to the existing quality automotive dealership. Any future expansion is to be completed with the same quality and care as the existing dealership, and would therefore add to the appearance of the area rather than detract from it. If you have any questions or require additional information, please call me at your convenience. Sincerely, 4119 J)O�Ll� ae��? Matthew A. Lucas, P.E., LEED@AP BD+C MAL/mrm 2279-48 cc: Missy Monier - Van Tuyl Group FEB 0 6, 2100 8350 N CENTRAL EXPY n STE XCY r L)A A�'�, X , . a c. SCHEDULE OF DRAWINGS A-1 OVERALL SITE PLAN A-2 LANDSCAPEPLAN A-3 EXTERIOR ELEVATIONS- N &W Al EXTERIOR ELEVATIONS -SSE rROP..NED USE DESCRIPTION, L CONDITIONAL NEE REdL9T a1-06 16 A RESUEET TO A9 THE PREVIOYILY lFP9'1.ED aim PLAN OF, a11-33. CUll-v Small 010E -1e (Oq,m,XN E :ODE -3a) P1ME AN MIST NG AUTOMOTIVE DEALER6HIP WITH 604.E6 AND EERNOE OF NEW AND u9ED VEFIICLES MECFICNIT to N.LCW A loll 6OMAREE PMT EX ANSIW TO TE SSINILE 411LDM3. 2 14I6 PE¢3EET 16 To AOD AV ADDInQUL SSSS a2L1RE REST OF NEA TO TE EXISTM 6ERNCE yJILO6JG To TYMPLT WITH NI66AN MAC£ 1ffa11Rm•eNTa ] THe AREA oP SNE Py PtlS® ENO JEES rJ11LORYl vswl W lE VIS. Y PAYED M1D uem A6 A YEHILLE ORIYE. NO APP TO OE IEONRED WOFNE �IOVEEDIAS AP TOTAL 911E AREA 5. THERE ARE NO OANNCES TO EXIETM OUTDOOR m2a aP LIC TNG CIA DRAINAGE PAM" ANTICIPATED 0FL {K3 III, WA {F63 Y 6063 OF PER, GTS IN TNI6M REVIEKN. MAXPVI ETALONS, 6. ALL EXISTING DPoYEWAre HAVE A nnNEYA Rama RAOILL] OF 24 OR 30 MEET, EXISTRLS CQIDITIONa Njawl Ell, TO RE31AN WCHAFGED. MAXMJt 1. nWMV1 DRIVE LANE WCTN& N d PRIVATE 949 OR PARCN'a LOTS TOR NEAD-N PARING Is 24 FEET. 239665 V A EXISTING PARCRG APACE mlENSIONa ARE'' Call SPACE FEET BY IS FEET. E 4 ALL FEGWP9'@E2S 6 THE GRA EVNE SOIL 663(3 M EAO61W cOMROL ORDINANCE SHALL EE MET DURING 1VE FEPoOD OP OCNaTTdICTION ANO ALL � iy W -DINE ELECRSCAL fANDUCTORN AIBOOIAipD bl WITH TVE NEiU CONSTRICTION MLALL EE LOCATED �', W9ERrymIAD. _ E WPT Tu." SNFT SPn-Ran No.OF E11q.pTEEy 60 { E \ �.. 6' -OW PLNCIETE WALK S t5'Ctl39 E SB1.1E _ _4 gln OW10 DE IIS' E OSI PARSONS,9PAC! BUILDRG RO'JR NEA+° IEONRED rRov OED TOTAL 911E AREA SERVICE! b PARTS EXI6rMG eXPANeIa+ m2a aP 1� gF 6305 w 118 13. Y TALO PP {K3 III, WA {F63 Y 6063 OF (669 ACf£S) MAXPVI ETALONS, 649 Oft Rama COYERAC£ Njawl Ell, S1ER MAXMJt 649 OR 949 OR p'PERNOL9 AREA 239665 V 236364 9P Call SPACE 209 OR 246 OR Ne.r Ran 663(3 M 68.111 Y PdPofING WAGES 54 66 EM%.oTEE 1N It 6 vsojs¢-e¢m 04 CUSTOMER PAF@Ya t 319 DI9FLAY 9PISCES TO '/XB tPo RIMED • N TOTAL 6 1 6 Accua914LE BPACE9 TOTAL PA INS, E4 N3 WPT Tu." SNFT SPn-Ran No.OF E11q.pTEEy 60 { E \ �.. 6' -OW PLNCIETE WALK S t5'Ctl39 E SB1.1E _ _4 gln OW10 DE IIS' E OSI PARSONS,9PAC! BUILDRG RO'JR NEA+° NEW CAR dIILDNG EASTM PRE-012ED C wil-PING EA61141 CAR NL1]HRG EBIILDNG exerlN6 SERVICE! b PARTS EXI6rMG eXPANeIa+ FTAT O MCImcmt A SECGm AREA TOTAL APoEA A PW' FDSED COOIRSNT 1� gF 6305 w 118 13. Y TALO PP {K3 III, WA {F63 Y 6063 OF 1311 gF WA 1�I gF IH11 PF 2{.60 SF 1302 SF 310" W 2{,e0 BF IjA6 3F W4 32.101 EP 26]08 SP J N E GrNGSE1NICE 0EPARTME143PAATS (19ARNSF.1NFLODO (P.F ELEV-9M.75) 2 STORY(W-7N1 b `aE O OM c, a OF 0 mow,{. TYPICAL PLAN 1M 03PARKING SPACE v9• = r -D• FeYf § Iu. OPERATION UL OPER ox ROX ODVT OEV£LOPMENT LMITPD PARINEPNNIP S1ER ID60 E. MIEBLUR. d11TE 300 o a �a jr a, FER1DNDEL AFO112T t6, PC Ne.r Ran MElwsw HlBm::r ua,R IRNA. TEXAS 15062 OVIP"ina, xlxxB vsojs¢-e¢m cNxoe.�aARCHITEc*Econ ��F'y '/XB ap �Wn 01 VICINITY MAP N.T.S. I 9ECTIW 2s, •cc• DlarRIcr • 2006 mteRNAnaNAL E COYWITY OO'P'IEPo:IAL .aTY a=GRAPEV6Ea 1LEE"_ • A+EPoCJNa wlrH Dlax P )VNnm RECENCY c CENTER ADDITION � PLAABTMREET I NITOTlG aWNK4JEG e ACID56% TNpryT CO31TT. TEXAa s n a I TANG m -- _ — N <i•a1']Y W . 552.p8• !01 1 vW'TRLV SEGMITTt'EI LOT AREA: 298,212 !M8.5 ACRESI CASE # U ( - RVS'D ORDI E # OO 35 02 OVERALL SITE PLAN �� 3, 1Q i 30 Rtli 30 1119 PLANNER H- F wwww CASENWE TFX69 NI39ANOFORAPEVINE CA9ENUMEM M12M LdYAON: AN WEETSTATEHIGHNAV 1L 40 CARLOS FERNANDEZ ARCHITECTS, P.C. WOECNERS'"I"SATE 270IRVING. TEXAS 75052 nnYB13d5111& FcB 1713 l: e.na,®nrvnll,nsox rig; e {rE a GREs20 12 F{g9g2_- - `^ UL ANT1 s j FEB 2 2012` 11 L1.. LQ r_c C W W d W co J O Z� Oy 1— p Z R' Z U. 0M Uz W Z? Lu Ij U) a Z • _i r `Qn7 fN H3 Z: moss` 6 Z. REVISION 0 2/21112 ISSUE DATE: 1/20/12 PROJECT NUMBER 1112.53 SHEET TITLE SITE PLAN CUP SHEET 1 OF 4 A-1 TYPICAL PLAN nP 03PARKING SPACE v9• = r -D• FeYf Iu. OPERATION UL OPER ox ROX ODVT OEV£LOPMENT LMITPD PARINEPNNIP S1ER ID60 E. MIEBLUR. d11TE 300 Noe m s9mu PAX. 602-2¢11-1660 FER1DNDEL AFO112T t6, PC Some OROKEpt DRIVE, WITE 10 IRNA. TEXAS 15062 TEL. ]11-650-M64 PAX. ]ll -6]4-1163 cNxoe.�aARCHITEc*Econ SECURITY m -- _ — N <i•a1']Y W . 552.p8• !01 1 vW'TRLV SEGMITTt'EI LOT AREA: 298,212 !M8.5 ACRESI CASE # U ( - RVS'D ORDI E # OO 35 02 OVERALL SITE PLAN �� 3, 1Q i 30 Rtli 30 1119 PLANNER H- F wwww CASENWE TFX69 NI39ANOFORAPEVINE CA9ENUMEM M12M LdYAON: AN WEETSTATEHIGHNAV 1L 40 CARLOS FERNANDEZ ARCHITECTS, P.C. WOECNERS'"I"SATE 270IRVING. TEXAS 75052 nnYB13d5111& FcB 1713 l: e.na,®nrvnll,nsox rig; e {rE a GREs20 12 F{g9g2_- - `^ UL ANT1 s j FEB 2 2012` 11 L1.. LQ r_c C W W d W co J O Z� Oy 1— p Z R' Z U. 0M Uz W Z? Lu Ij U) a Z • _i r `Qn7 fN H3 Z: moss` 6 Z. REVISION 0 2/21112 ISSUE DATE: 1/20/12 PROJECT NUMBER 1112.53 SHEET TITLE SITE PLAN CUP SHEET 1 OF 4 A-1 TOT, DTiT emu Cil SITE PLP APPV'D CASE # RVS'D ORDR DATE PLANNER. 0 30' 60' •... za rB AT ON Sea ]B.Y DISTRICT CGHMd11TY flRF IAL LEGEND maREES To Tm O, To 3V1Wls r , I To STING lNAS6 u TOTim SeStSHz O U 7�SNISWOFGW�WESWIOFGWP WE S STATEMGXVIAYII< SECRETARY WauiOIDNINO COMMISSION J cwARMnN z OPT : OL SXEE1: M2 U' 4 F AFPRWALGOESNOTAUT10RUEANY Q �WCES WORK INMNCµYC MOR Z OEFAATMENTOFOEVELDPMFNTSERVICES O 4to C A R L 0 S FERNANDEZ ARCHITECTS, PC SNOECIQR9 iNE•SIIRE2M IRVING• TEXAS 75062 :TVN6alm I¢9/Il lm :T= [nln8olurthibtli,eom •1P't. %1 �5 $ r Ochs REVISION 0 221112 ISSUE DATE: 120/12 nm5 p PROJECT NUMBER 1112.53 SHEET TITLE E2 Nim FAR,, LANDSCAPE r as 1X81 W j MISS 111BX^:r ua' • . c..p..mq whrR s,a JCy MBS 607 ) �1 N1F[9 WY VI 14 e Is acI 3 SHEET 2 OF 4 A-2 f�m,tlwMSM�inNANNA Bi illAx �� ,p4 w SAP Naow...wr� F' rv+wu m VICINITY MAP N.T.S. za rB AT ON Sea ]B.Y DISTRICT CGHMd11TY flRF IAL LEGEND maREES To Tm O, To 3V1Wls r , I To STING lNAS6 u TOTim SeStSHz O U 7�SNISWOFGW�WESWIOFGWP WE S STATEMGXVIAYII< SECRETARY WauiOIDNINO COMMISSION J cwARMnN z OPT : OL SXEE1: M2 U' 4 F AFPRWALGOESNOTAUT10RUEANY Q �WCES WORK INMNCµYC MOR Z OEFAATMENTOFOEVELDPMFNTSERVICES O 4to C A R L 0 S FERNANDEZ ARCHITECTS, PC SNOECIQR9 iNE•SIIRE2M IRVING• TEXAS 75062 :TVN6alm I¢9/Il lm :T= [nln8olurthibtli,eom •1P't. %1 �5 $ r Ochs REVISION 0 221112 ISSUE DATE: 120/12 PROJECT NUMBER 1112.53 SHEET TITLE LANDSCAPE SITE PLAN ) e CLIP 3 SHEET 2 OF 4 A-2 01 NEW SERVICE BAYS EXTERIOR ELEVATION (NORI h) 1/8' = 1'' GRAPHIC U D' 4' B' 16' 32' SCALE 02 NEW SERVICE BAYS EXTERIOR ELEVATION 1 GRAPHIC iS' 32• SCALE D 4' 8 CITY OF GRAPEVINE SITE PLAN REVIEW COMMITTEE APPV'D a-0 DENIED CASE# Cu ID -oma RVS'D ORDINANCE DATE PLANNER bERNCE A PARrb WILDMG EXIERICA TOTAL S6 FT. A MA4LNRf (53 FTJ ELEVATId {R' -NT MORNII f.93O S2 ET. 10LR !4.930 Y1 FT) REAR tBdJTN) 3S'-! BO. Ff. Iii <3$9! B1 FTJ RWHT (EA91) 1315 81 FT. 16�0Y. (lily M FTJ LEFT fLLE9T, l.Ibl 81 FT Imo% (!164 51 ET) TOTrY 86 FT. Il)33 91 FT. 109% 1ni33 61 FTJ 4 to CARLOS FERNANDEZ ap cP ccR+clrelE ARCHITECTS, P.C. gqp GECKERgiNE.3UITE Rl0 IRVING. TEXAS r5062 pp,[: Gtt 8561161 Ic GttE`A114i I'. u[rlea0[lan[6ib[b.tom colr->aeTE h g•� y�ER� E%PIRES: I.2m_I2 1(1N12 CONSULTANT WID FLOOR�� X E- W Qw z� ETNG ror cs caNc�E _ ar-x16T. a fiJD=.� Z 1 z 0 UREVISION J rDATE ME:TIXAS NICSPNO 8ZWAV wE n� MBER: LU12C6 Q 1b1 WEST CTPTE HIGXWAY 111 B YCR SECRETARY WQ. ISSUE DATELJ 1120/12 PLANNING AND ZONING COMMISSION V! PROJECT NUMBER J O 1112.53 QSWEET TITLE cHPIRMAu Z K ELEVATIONS GATE: 0 y NORTH, WEST SHEET AG OF d G APPRGVALGOESNOTAUTHORIZEFNY rO GTfP WORX IN CONFLICT WITH ANY CODES OR ORDINANCES Z SHEET 3 OF 4 DEPARTMENT OF DEVELOPMENT SERJICES O UH �� i _ n4 NFW SERVICE BAYS EXTERIOR ELEVATION vi V -w GRAPHIC 16' 37 SCALE p' 4' 8' T IiTMG OP a DQ1CpETE h 29'-T —� E Tr=NOI{ETE h 02 NEW SERVICE BAYS EXTERIOR ELEVATION I GRAPHIC 0' 4' IT 1S 32' SCALE L:`fyv _)1F C; . 'EVINE SITE ELAN REVIEW ColviNlITTEE APPV'D- 02- 0—DENIED_—_----- CUra-oma CASE # 08-.35 RVS'D ORDINANCE # DATE �,�}� la PLANNER EETaIrE dND PdRTi d11LDMG 1 Mg9LNRT rxi RJ ICGt (f.]30 MPTJ 1011 (3b9f 61 FTJ ,yay; (f1i486 FTJ Immf m.233xiRJ CASEX ME; TE%A8 NI85ANK GPAPE lw CAGE XJMBER: CUa2-05 WpTION: IWI WEST STAIE XICNWAV IIi OATS' MAYdi SECRETARY PIANN ING AND ZONING COMMMSIGN DAM SHEEP: A�< OF A OVALDOES NOTRU]NO=r WOaN IN CONFOw >gANY OWEG Ofl OEPAI(IMENTOFOEYELOFMEMS 1a 5 40 CARLOS FERNANDEZ ARCHITECTS,P.0 SB] pEgQa w+INE. sulrE 2]0 Ifl VING, TE%A8 ]5082 pva 2R�a81 hNBTNB'lip I: satloaB[IvnMb[ta.e[e m z O Q U J 1 1 Q FC. G Lu W EL w J o Z Oo z OF Ui • Z: Is REVISION ISSUE DATE: 1/20/12 PROJECT NUMBER 1112.53 SHEET TITLE ELEVATIONS SOUTHEAST CUP SHEET 4 OF 4 A-4 E%I OR TOTAL i PT. ELEVA4M OP of aMm F T (NCRTW {,930 BO. Ft. REAR (Sp11W 9b9f iD. FT. EXISTING PYLON SIGN R�T(E T) 4A15xiR 03 IFR (IIE5T) uis xi Fr. GRAPHIC TOTAL ba Fr. IIA33 32' SCALE P 4' g. 8' 1 Mg9LNRT rxi RJ ICGt (f.]30 MPTJ 1011 (3b9f 61 FTJ ,yay; (f1i486 FTJ Immf m.233xiRJ CASEX ME; TE%A8 NI85ANK GPAPE lw CAGE XJMBER: CUa2-05 WpTION: IWI WEST STAIE XICNWAV IIi OATS' MAYdi SECRETARY PIANN ING AND ZONING COMMMSIGN DAM SHEEP: A�< OF A OVALDOES NOTRU]NO=r WOaN IN CONFOw >gANY OWEG Ofl OEPAI(IMENTOFOEYELOFMEMS 1a 5 40 CARLOS FERNANDEZ ARCHITECTS,P.0 SB] pEgQa w+INE. sulrE 2]0 Ifl VING, TE%A8 ]5082 pva 2R�a81 hNBTNB'lip I: satloaB[IvnMb[ta.e[e m z O Q U J 1 1 Q FC. G Lu W EL w J o Z Oo z OF Ui • Z: Is REVISION ISSUE DATE: 1/20/12 PROJECT NUMBER 1112.53 SHEET TITLE ELEVATIONS SOUTHEAST CUP SHEET 4 OF 4 A-4 I I -U- -4B- I I I I I s 01 NEW WAITING ROOM EXTERIOR ELEVATION ( NORTH) 1/8" = V-0.. I I Q— —©——U--�—®— —0— 02 NEW WAITING ROOM EXTERIOR ELEVATION ( EAST) 118" = 1'-0" EXIST) G h TOP CE CONCRETE 25'-T 7p05E0 Cf LCMICRETE J� m 3 GI FLOOZY EXISTING TOP OF CONCRETE h los T PROPOSED TOP 6 LGv'CRETE J� 3 Revised elevations supertedes elevations approved by SPRC an March 7, 2012. The revisions reduce the height of the approved expansion Of the service depanmem and pans building *am 29' 7" to 20' 6% along with othelminor changes as noted on the elevation dewsI� IIg . 914,3l�� EXTERIOR - COLOR AND MATERIALS OESCRIPTWN MANUFACTURER) PAINT NO. LOCATION COLORAMATERIAL SPECIFICATIONS SUPPLIER P-1 CONCRETE PANEL SATIN LIGHT SILVER HALF DOLLAR 2121-10 BENJAMIN MOORE H CO WALLS GREY PAINT SATIN FINISH P-2 HLW MTL MORS, SEMIGLOSS SILVER HALF OMLAR 2121-00 BENJAMIN MORE S CO OH MORS. LIGHT GREY SEMI,GLOSS FINISH HANDRARS, PAINT PAINT OWNS AND FRAMES TRIMS, GATES, TO MATCH LOWERS. BOLLARDS 40 CARLOS FERNANDEZ ARCHITECTS, P.C. 580 DECKER DRIVE. SHITE 3T0 IRVING, TEXAS )5002 emM�[aiilo.�® Ia 4.972856`105 CONSULTANT z0 u4 L a REVISION Q a -T- ISSUE DATE: 02-27-2012 PROJECT NUMBER 1111.49 SHEET TITLE ELEVATIONS NORTH, EAST CUSTOMER AREA - SERVICE BLDG SHEET 130F 23 AV I —O— —�— —Q— —�— I I 01 NEW SERVICE BAYS EXTERIOR ELEVATION (EAST) 1/8. = 11-011 -O- -O- -®- -O- I It JI U� JI II�� ��_ NEW CONCRETE METPL COIPAINT PIIYa,D 39 PGNE a HATNEWCH PAINT F1, TYP PI, TYP I ➢-u N R rI If S I I Jf -PI-I— r_ g 11V 11 4.il a 11 �W=J SLI 0 T� �1 TOP 6 CONCRETE i Ir A 1111—H lJL Mr .. 1C �1 �� u u -.. 20.-6. n I _I L��� ,IIr 4 � 1�p� Ifff� I 1 2: ) ��A�D�OR MODIFY .— LENGTH TO 44'-10', REPLACE D SOUTHEAST CCLIPW 4T OU STHEAST CORdER PAINT P2 150 T.REF A0]/05, TTP ♦ cND FLOOR EXISTI,W' METAL EXISTING EXISTING, FETAL EXIT NS METAL OVERHEAD DOOR CONCRETE EXISTYY EXISTING EXISTING RELOCATED AGAF NEW 10'U x p'H NO PAINT, TYP OVERHEAD DOOR, CONCRETE HOLLOW METAL OVERHEAD DOOR CONCRETE DR41N AND PIETA - PAINT, NO NO PAINT, TYP PANELS, NO DOOR ARE, NO PAINT, TTP PANELS, NO OVEISLOW DRAIN OVERHEAD PAINT. TTP PAINT, TYP FRAME, NO PAINT, TYP DOWNSPOUT NOZZLES, COOR, PAINT PAINT, TYP REF A33/05, SIM En' TYP RevisW elevations superce,les easations approve) by 02 NEW SERVICE BAYS EXTERIOR ELEVATION (SOUTH) BPRC on Maroproved z. anaremaithe seaneea" height nof ethe approved W batting of the service III With and parts "hang from noted 1020' 6", elmg with plM10 minor changes as note) on,{he elevation P a a ro �, J5E7192012 EXTERIOR — COLOR AND MATERIALS PAINT OESCRIPTIOW MANUFACTUFFN NO. LOCATION COLORMATERAL SPECIFICATIONS SUPPLIER P-1 CONCRETE PANEL SATIN LIGHT SILVER HALF DOLLAR 212110 BENJAMIN MOORE 6 CO WALIS GREY PAINT SATIN FINISH P-2 HLW ST. COMES, SEMIGLOSS SILVER HALF DOLLAR 2121AO BENJAMIN MOORE B CO OR DOORS, LIGHT GREY SEMWLQSS FINISH HAADRNLS, PAINT PAINT COORS AND FRAMES TRIMS, GATES. TO MATCH LOUVERS. COLLARDS • CARLOS FERNANDEZ ARCHITECTS, P.C. 5900ECHER DRIVE. SUITE 270 IRVING, Tay AS 75062 PMei nR2a 1761 ® Iaahieel64tI 1733 n J) N2 �a42 9rE OF Ste' E%PI0.ES. A9�2 4/3W12 CONSULTANT x u; Qw a w� Z wCA REVISION Q5-1-12 ISSUE DATE: 2-13-12 PROJECT NUMBER 1111.49 SHEET TITLE ELEVATIONS SOUTH EAST SERVICE BAYS SHEET 6 OF 12 A2a2