HomeMy WebLinkAboutCA2014-4207/09/14 11:54AM CDT CCR Roofing, LLC -> 18174103038 Pg 2/2 Tenant NamelOccupancy/Use C�ty Frns� RequestlDeseription of Work to Be Done re roof roofing material will not be visible from the ground and no appearance of - _ the builiding is included in the work scope - - Drawings/Sketches Attached L Phot ra hs Attached t1 Yes * No a Current 0 Historic Material Sam les Attached lease list Thermoplastic pol�lifin_TPO I hereby certify that this information is correct to the best of my knowledge and that the said work will he done in conformance with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and Building Codes. APPROVAL OF A CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF OTHER REQUIRED BUILDING PERMITS. Signed x Z.,� Print Name / Owner or Contractor " { Office Use y� } ,1 Approved Approved with Conditions: _ _ I ���-►'"�1 I I ,�,� �.i l b-�' •_,) T Chatr - Hisluric Preservatiun Crunmission H v c Prsssrvafin C)lrger — x _ _ _ Date Building Official THIS IS NOT A BUILDING PERMIT, A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE STARTING WORK. City of Grapevine Hislorin Praservation Department 1536 SOU111 Mein Street, Grapev'ne, Texas 76051 - (617) 410-3556 010214 CERTIFICATE OF APPROPRIATENESS APPLICATION ���` date 71$12014 Number Propertm Owner Name Address & Phone Number licant Name Address & Phone Number Janet - - --� - - - - CCR Roofing 590.�Sil Path— Phone: 5174$06361 — - - - - Phone; 12,560.5393— Mobile: Mobile Email: Email: Property Address include any suite number Legal Description 430 S main St Black Lat J�1 f �% Subdivision Tenant NamelOccupancy/Use C�ty Frns� RequestlDeseription of Work to Be Done re roof roofing material will not be visible from the ground and no appearance of - _ the builiding is included in the work scope - - Drawings/Sketches Attached L Phot ra hs Attached t1 Yes * No a Current 0 Historic Material Sam les Attached lease list Thermoplastic pol�lifin_TPO I hereby certify that this information is correct to the best of my knowledge and that the said work will he done in conformance with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and Building Codes. APPROVAL OF A CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF OTHER REQUIRED BUILDING PERMITS. Signed x Z.,� Print Name / Owner or Contractor " { Office Use y� } ,1 Approved Approved with Conditions: _ _ I ���-►'"�1 I I ,�,� �.i l b-�' •_,) T Chatr - Hisluric Preservatiun Crunmission H v c Prsssrvafin C)lrger — x _ _ _ Date Building Official THIS IS NOT A BUILDING PERMIT, A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE STARTING WORK. City of Grapevine Hislorin Praservation Department 1536 SOU111 Mein Street, Grapev'ne, Texas 76051 - (617) 410-3556 010214 �Rr�f-�Z Tarrant Appraisal District Real Estate 07/09/2014 Account Number: 01089900 Georeference: 16060-3-14-10 Property Location: 430 S Main St, Grapevine Owner Information: Shaw, Wanda & Janet Dickey 5901 Quails Path Colleyville Tx 76034-7515 1 Prior Owner Legal Description: Grapevine, City of Blk 3 N42'14 Taxing Jurisdictions: 011 City of Grapevine 220 Tarrant County 224 Tarrant County Hospital Dist 225 Tarrant County College Dist 906 Grapevine-Colleyville ISD This information is intended for reference only and is subject to change. It may not accurately reflect the complete status of the account as actually carried in TAD's database. hroaosea values Tor I ax Year zui4 t Appraised value may be less than market value due to state -mandated limitations on value increase, tt A zero value indicates that the property record has not yet been completed for the indicated tax year tttRounded 5 -Year Value Ii1STo Tax Year Land Impr 2014 Total tt Market Value $55,440 $193,560 $249,000 Appraised Value $55,440 $193,560 $249,000' Approximate Size ttt 4,620 Land Acres 0.1060 Land SaFt 4,620 t Appraised value may be less than market value due to state -mandated limitations on value increase, tt A zero value indicates that the property record has not yet been completed for the indicated tax year tttRounded 5 -Year Value Ii1STo Tax Year XMPT Appraised Land Appraised Impr Appraised Total Market Land Market Impr Market Total 2013 000 $55,440 $193,560 $249,000 $55,440 $193,560 $249,000 2012 000 $55,440 $193,560 $249,000 $55,440 $193,560 $249,000 2011 000 $55,440 $170,848 $226,288 $55,440 $170,848 $226,288 2010 000 $55,440 $176,848, $226,288 $55,440 $170,848 $226,288 2009 000 $55,440 $170,848 $226,288 $55,4401 $170,8481 $226,288 2014 Notice Sent: 04/30/2014 Exemptions: None Property Data Deed Date: 07/12/2004 Instrument: D204225723 Year Built: 1946 TAD Map: 2126 460 MAPSCO: 027M Agent: None Protest Deadline: 06/02/2014 Class:040 State Code: F1 Commercial Garage Bays: 00 Central Air: Central Heat: Pool: N 9 July 2014 Janet Dickey 5901 Quails Path Grapevine, TX 76059 A Future With A Past RE: PRESERVATION COMMISSION CERTIFICATE OF APPROPRIATENESS # CA14-42 430 SOUTH MAIN STREET GRAPEVINE, TX 76051 This letter confirms on July 9, 2014, Historic Preservation staff approved with conditions #CA14-42 for the property addressed 430 South Main Street, Block 3 N42'14, Grapevine, City of, Grapevine, Texas. The following was approved on this Certificate of Appropriateness: to re -roof with roofing material Thermoplastic polyolefin (TPO) with metal custom fit coping, 1 %" exposure painted to match brick as per the material description attached with the condition a permit be obtained from the Building Department. An approved Certificate of Appropriateness is not an approved Building Permit and a permit , sem/ is not required. Contact the City of Grapevine's Building Department at 817-410-3165 for information regarding permits. Thank you, David Klempin Historic Preservation Officer cc: Property Owner CA File THE CITY OF GRAPEVINE HISTORIC PRESERVATION - 636 South Main Street - Grapevine, Texas - 76051 - Phone 817/410-3197 Fax Number 817/410-3125 L,(//v S/ -), -5- 6U, -_1) q � VersiWeld® Mechanically Attached Form -Spec November, 2013 PART1 GENERAL 1.01 DESCRIPTION A. The Grapevine Florist is located at 430 S main in Grapevine TX . Terry Washburn , Project Manager/Coordinator, is the Owner's Representative and may be contacted regarding any questions or for a pre-bid job site inspection, phone 512 560 5393 . B. The project consists of installing Versico's VersiWeld (TPO) Mechanically Attached Roofing System as outlined below: : Apply the VersiWeld Mechanically Attached Roofing System in conjunction with 2 inch poles after tear off of the existing built up roof to expose the wooden deck for verification of suitable substrate as specified in this specification. 1.02 EXTENT OF WORK A. Provide all labor, material, tools, equipment, and supervision necessary to complete the installation of the VersiWeld.060-mil, thick white, reinforced TPO (Thermoplastic Polyolefin) membrane Mechanically - Fastened Roofing System including flashings and insulation as specified herein and as indicated on the drawings in accordance with the manufacturer's most current specifications and details. B. The roofing contractor shall be fully knowledgeable of all requirements of the contract documents and shal l make themselves aware of all job site conditions that will affect their work. C. The roofing contractor shall confirm all given information and advise the building owner, prior to bid, of any conflicts that will affect their cost proposal. D. Any contractor who intends to submit a bid using a roofing system other than the approved manufacturer must submit for pre -qualification in writing fourteen (14) days prior to the bid date. Any contractor who fails to submit all information as requested will be subject to rejection. Bids stating "as per plans and specs" will be unacceptable. 4. static backout resistance of 10 inch pounds minimum is required. Certification from the membrane manufacturer indicating the membrane thickness over the reinforcing scrim (top ply membrane thickness) is nominal .15 -mil or thicker. 6. Certification of the manufacturer's warranty reserve. B. Upon completion of the installed work, submit copies of the manufacturer's final inspection to the specifier prior to the issuance of the manufacturer's warranty. 1.10 JOB SITE PROTECTION p 2 � A. The VersiWeld TPO White membrane meets CRRC (Cool Roof Rating Council) for reflectance and emittance. When tested in accordance with ASTM C1549, the VersiWeld White material has an initial solar reflectance of 0.79 and a 3 -year aged reflectance of 0.70. The material has also been tested for emittance in accordance with ASTM C1371; an initial emittance of .90 and a 3 -year aged emittance of 0.86 were achieved. B. The VersiWeld White TPO membrane meets the emittance requirements set forth by the USGBC (U. S. Green Building Council) for their LEED (Leadership in Energy and Environmental Design) Program. The VersiWeld White TPO material has an emittance of 0.95 (when tested in accordance with ASTM E408) and an SRI (solar reflectance index) of 110 (calculated using ASTM E 1980). 2.06 METAL EDGING AND MEMBRANE TERMINATIONS (Choose the appropriate type of metal edging or membrane termination and delete the types which will not be used) A. General: All metal edging s shall be tested and meet ANSI/SPRI ES -1 standards and comply with International Building Code. -- B. Coping: Custom fit coping with !.5 inch exposure from the street. (Olf 0 u I ,W` U �c C. Termination Bar: a 1" wide and .098" thick extruded aluminum bar pre -punched 6" on center; incorporates a sealant ledge to support Lap Sealant and provide increased stability for membrane terminations. 2.08 OTHER MATERIALS Metal Flashing, if required, and miscellaneous items needed to fulfill the project requirements D. Apply Cut Edge Sealant on all cut edges of reinforced membrane (where the scrim reinforcement is exposed) after seam probing is complete. Cut edge sealant is not required on vertical splices. 3.05 FLASHING A. Flashing of parapets, curbs, expansion joints and other parts of the roof must be performed using VersiWeld reinforced membrane. VersiWeld non -reinforced membrane can be used for flashing pipe penetrations, Sealant Pockets, scuppers, as well as inside and outside corners when the use of pre -fabricated accessories is not feasible. B. Follow manufacturer's typical flashing procedures for all wall, curb, and penetration flashing including metal edging/coping and roof drain applications. CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE RELEASEP, 2- PURSUAN, T CA DATE 1 BY /L DEPARTMENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION POLYISO INSULATION VERSICO POLYISO - TYPICAL PROPERTIES Property Dimensional Stability Water Absorption Moisture Vapor Transmission Compressive Strength Product Density Service Temperature Test Method Typical Results ASTM D2126 < 2% linear changa 7 days ASTM C209 < 1 % by volume Water ASTM E96 < One (1) perm ASTM D1621 20 psi minimum"' (138kPa) ASTM D1622 Nominal 2.0 lbs./cu.ft. -100 degrees F to +250 degrees F Max. 'The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data is offered as a service to our customers and is subject to change. All information can be confirmed by contacting Versico. '•The numerical ratings as determined by ASTM Test Method E84 are not intended to reflect hazards presented by this or any other material under actual tire conditions. "'Also available in 25 psi minimum. MECHANICALLY ATTACHED Versico Polyiso insulation is Mechanically Attached to the roof deck with Versico Insulation Plates and Fasteners typically every 8 square feet. The VersiGard or VersiWeld Membrane is installed over the insulation and Mechanically Attached along the seam area to the roof deck with Versico Fasteners and Plates or Versico Fasteners and Batten Bar. Ad- joining sheets of membrane are seamed together according to current Versico Specifications. STORAGE Factory -applied packaging is only irMended for protection during transit. When stored outdoors or on the jobsite, packages should be stacked on pallets at least 4 inches above ground level and completely covered with a weatherproof covering such as a tarpaulin. VERSICO POLYISO REGULATORY COMPLIANCES • Federal Specifications - HH-1-1972/GEN and HH -1-1972/2 Class 1 • ASTM 1289-01 • Metro -Dade County, Florida Product Quality Standards and Title 25 Foam Flammability Criteria (License #TC 1231) • BOCA, ICBO, SBCCI Sections on Foam Insulation • CCMC No. 12464-L For more information and samples please call 1.800.992.7663. FM STANDARD 4450/4470 APPROVAL Versico Polyiso is approved for Class 1 insulated steel, wood, concrete and gypsum roof deck construction for both 1-60 and 1-90 windstorm classifications (may be mopped or mechanically attached to concrete roof deck). Refer to FM Approval Guide for details on specific systems. UL STANDARD 1256 CLASSIFICATION • Insulated metal deck construction assemblies • Construction #120 and #123 UL STANDARD 790 CLASSIFICATION • Class A with most roof membrane systems • See UL Building Materials Directory UL STANDARD 263 FIRE RESISTANCE CLASSIFICATION (ASTM E 119) Some Classifications for fire resistance are P225, P230, P259, P508, P510, P514, P701, P713, P717, P718, P719, P720, P722, P723, P724, P725, P727, P729, P730, P732, P801, P814, P815, P818, P819, P823 and P828. See UL Fire Resistance Directory for updated listings. 'The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data.; .P,red as a service to our customers and is subject to change. All information can be confirmed t,' contacting Versico. -The numerical ratings as determined by ASTM Test Method E84 are not intended to refiect hazards presented by this or any othermoterlal underactual bre conditions. • Also available in 25 psi minimum CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE -.. RELEAS . PURSUANT 1 DATE a BY DE AR ENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION C; tt /'r- T--1- AZVj POLYISO INSULATION POLYISOCYANURATE INSULATION FOR VERSICO ROOFING SYSTEMS Versico Flat and Tapered Polyiso MP -H Versico Polyisocya nu rate (polyiso) insulation consists of state-of-the-art polyiso foam with superior fire performance characteristics and the ability to retain high R -values ranging from 6.0 to 25.0. Versico Polyiso is manufactured with exceptional strength, using dimensionally stable facers, which add durability to the boards. Versico Polyiso MP -H and Tapered MP -H feature polyisocyanurate laminated to heavy, black, fiber -reinforced felt facers. Versico Polyiso Insulation is recommended for use for Fully Adhered, Mechanically Attached and Ballasted VersiGard , and VersiWeld� Roofing Systems. Tapered MP -H is manufactured with a tapered profile to promote positive drainage while maintaining the highest thermal efficiency available in a tapered system. Flat and tapered Polyiso is available in 25 psi. STANDARD SIZES Nominal Thickness MP -H Inches LTTR Value 1.0' 6.0 1.2' 7.2 1.3' 7.6 1.5' _ ;`5:�` 1 CATI E OF APPROPRIATENESS 1.6 b.s.s C;I r'/ OF GRAPEVINE 1.8' ' 1 9 eRELEASFI _q2 ' 2.0' tIRSUA T� CA_ ATE �B 2.3 14. D PAR MENT OF 2.5' 15.3 DEVELOPMENT SERVICES 2.7' 16.6 3.0' 1ANTACT BUILDING INSPECTIONS 3.2' 19.81FOR r'FRMIT INFOPMATION 3.4' 21.1 3.8' 23.7 4.0' 25.0 • Avokb).e ;e 4' 4' c;: -.. ' , ... Y.- nss of t" to 4'. • A"flob:s -125 us- .^ - - • Avaftbty'IDC" " -' .. ,... ', Cer toot. "Long -Term Thermal Resstcnce Va:ues are based on C1289-01 (pending) and CAN/ULC 5770 which provides for a 75 -Year time weighted average. • •Other thicknesses available upon request. Inches to millimeter conversion 7 -In. = 25.4-am. When an LTTR Value greater than 16.6 is required, Venico recomm. en=ds multiple layers of insulation with staggeredjoints. VERSICO ROOFING SYSTEMS SYSTEM ACCESSORIES INSTALLATION - BALLASTED Versico Polyiso insulation is loose -laid over the roof deck. The insulation must fit together tightly to prevent separation, movement and damage during membrane installation. VersiGard Membrane is then loose -laid over the insulation. Adjoining sheets of membrane are seamed together according to current Versico Specifications, The assembly of insulation and membrane is held in place with a minimum of 10 lbs. of ballast per square foot, INSTALLATION - FULLY ADHERED Install Versico Polyiso insulation with perforated side down, Mechanically attach the insulation boards to the substrate, typically every 2 square feet. Coat the insulation and membrane with Substrate Adhesive at a coverage rate of 60 square feet per gallon of finished surface, Roll the coated membrane onto the coated insulation and broom to ensure contact. Complete the roofing system per Versico Specifications. A SINGLE SOURCE FOR SINGLE -PLY ROOFING Versico, PO Box 1289, Carlisle, PA 17013 Te': 800.992.7663 Fax: 717.960.4036 Web: www.versico.com