Loading...
HomeMy WebLinkAboutELEC2020-3076 ELECTRICAL PERMIT (VALUE) (RA F aV IN Issue Date:August 27,2020 q PROJECT DESCRIPTION: RESTORE POWER"GREAT WOLF LODGE" 4, PROJECT# (817) 410-3010 www.mygov.us ELEC-20-3076 Inspections Permits City of Grapevine LOCATION TENANT LEGAL Grapevine,,T TX 76099 9 P.O.Box 100 Great Wolf Dr. Great Wolf Lodge Great Wolf Addition Of X (617)410-3165 Voice Grapevine, TX 76051 Grapevine Blk 1r Lot 1r (817)410-3012 Fax CONTRACTOR INFORMATION Angiel Electrical Construction Corp County Tarrant State ID#23982 Square Footage 500 9030 Directors Row VALUATION 2500.00 Dallas, TX 75247 (214)824-6369 Phone Zoning CC-Community Commercial (214)821-9185 Fax FEES TOTAL=$57.00 (469)576-7614 Mobile Electrical Permit Fee(VALUE} $ 57.00 OWNER PAYMENTS TOTAL=$57.00 Great Wolf Lodge Grapevine Llc Angiel Electrical Construction Corp(Paul A. 525 Junction Rd Ste 6000 Atkinson) ($57.00) Madison, WI 53717-2153 Cc on 0812712020 NOTICES AVAILABLE INSPECTIONS ALL work must be done in compliance with the 2005 NATIONAL ELECTRIC � Electrical Service(required) CODE. r Electrical Final (required) PLAN SUBMITTAL:WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL,THREE (3)SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND/OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. BCS SWITCHGEAR, INC. 4790 Hwy 377 South MIR 24-Hour 888-599-0486 Krugerville, TX. 76227 Fax 940-365-1808 JOB ID# 20-145 LOW VOLTAGE CIRCUIT BREAKER - TEST REPORT CUSTOMER GREAT WOLF LODGE DATE 08/27/20 LOCATION ELECTRIC ROOM/CHILLER PANEL ID# DWI MAIN ROOM ID# ELECTRIC ROOM/CHILLER Breaker ID# NA NAMEPLATE DATA MFR. EATON SERIAL# 33SO1830 CHG na TYPE ICCB/MDS4000 MECH TYPE AIR CONTROL CLOSE na VOLTS 600 RCK TYPE FIXED VOLTAGE TRIP na AMPS 4000 CUBICAL NA UV na VISUAL INSPECTION PRIMARY DISC. NA ITRIP MECH PASS INTERLOCKS NA ARC-CHUTES PASS ICLOSING MECH NA SECONDARY DISC. NA PHASE BARRIERS NA RACKING DEVICE DRAW OUT BELL ALARM L/O NA PRIMARY CONTACTS NA LUBRICATION NA BLOWN FUSE IND. NA CONTACT RESISTANCE RESULTS IN MICRO OHMS A I 26 NO B 1 23 NO I C 24 ND INSULATION TEST A-GRND >1000MD B-GRND >1000MD C-GRND >1000MO A-B >1000MD B-C >1000MD A-C >1000M4 A-OPEN >1000Mf1 B-OPEN >1000M0 C-OPEN >1000M0 OVERCURRENT TRIP DEVICE TYPE TRIP UNIT DIGITRIP 520 SERIAL# NA CURVE# FUNCTIONS LSIG RATING 4000 CT TAP 4000 NAMEPLATE DATA LT P/U SETTING 0.5 IN P/U SETTING 2 LT DELAY 2 GF P/U SETTING 0.25 ST P/U SETTING 2.0 GF DELAY 0.5 ST DELAY 0.5 PRIMARY METHOD TEST RESULTS TYPE TEST TESTAMPS RESULTS CURVE SPECS A B C LONG TIME 5.2 1 8 6000 7.159 1 7.020 1 7.160 PICKUP SHORT TIM 0.39 1 0.50 12000 0.488 0.488 0.488 INSTANTANEOUS 6400.00 9600.00 8450.000 8395.000 1 8605.000 GROUND FAULT 0.39 0.5 3000 0 0 0 BREAKER IS ACCEPTABLE REMARKS TECH TRAVIS LANGER REV. 5 Engineered Power Services C Engineered Power 972-268-1277 SERVICES GROUND FAULT RELAY TEST REPORT CUSTOMER: LOCATION: JOBNUMBER: ANGEL ELECTRIC GREAT WOLF LODGE 20-145 DATE: 9030 DIRECTORS ROW 100 GREAT WOLF DRIVE 812712020 TESTED BY: DALLAS TX 75247 GRAPEVINE TX Daniel Rivera VOLTAGE: NEUT. RES.TO GRD.: SETTINGS SUPPLIED BY: 2771480 >3000MOHMS As Found SWITCHBOARD: TEST EQUIP.ASSET#: CALIBRATION DATE: 4000 AMP MAIN BREAKER LEFT SERVICE NA 11011712020 As Found and As Lek settings Manufacture EATON Trip Unit DIGITRIP 520 Ir 1 1 Model DS4000 tr 4 4 Seriel 33SO830 Is 6 6 Phase to Ground Phase to Phase Main Circuit Breaker is .3 OUT 3 OUT Phase A >3000M I 000M Phase A Line-Loadl >3000M II 8 8 Phase B >3000M I B-C >3000M Phase B Line-Loadj >3000M Ig 1200 1200 Phase C >3000M I C-A 1>3000M Phase C Line-Loal >3000M tg 1 .2 ON 1 2 ON Insulation Resistance 150% 200% Main Breaker Contact TEST RESULTS PICKUP AMPS CURRENT 150% TIME CURRENT 200% TIME TEST RESULT TEST RESULT Resistance Measurement AIN NO TRIP 2000A Phase A 26uohms BIN NO TRIP 2000A Phase B 23uohms C/N NO TRIP 2000A Phase C 24uohms AIN TRIP TEST 1200A 1400A 0.429 2200A 0.245 BIN TRIP TEST 1200A 11400A 0.446 2200A 1 0.215 C/N TRIP TEST 11200A 11400A 1 0.545 L2200A 0.235 IS GROUND FAULT SYSTEM ACCEPTABLE ? YES WERE EQUIPMENT GROUNDS & BONDING JUMPERS INSTALLED ? YES WERE SERVICE ENTRANCE CONDUCTORS INSTALLED ? YES WERE FEEDERS INSTALLED ? YES NOTES: TESTED WITH CB-832 BREAKER PASSED TESTING