Loading...
HomeMy WebLinkAboutCA2020-111A Future With A Past 2 December 2020 Donny Mahan Grapevine Masonic Lodge 403 South Main Street Grapevine, Texas 76051 817 821-7159 RE: HISTORIC PRESERVATION COMMISSION CERTIFICATE OF APPROPRIATENESS #CA20-111 MAIN STREET COMMERCIAL HISTORIC DISTRICT ORDINANCE #92-39, #HL92-01 HISTORIC GRAPEVINE MASONIC LODGE BUILDING 403 SOUTH MAIN STREET GRAPEVINE, TEXAS 76051 GRAPEVINE MASONIC LODGE, OWNER This letter confirms on December 2, 2020 the Historic Preservation Commission staff approved with conditions #CA20-111 for the property addressed 403 South Main Street, legally described as Block 18, Lot 9 & 10, City of Grapevine Texas. The following was approved on this Certificate of Appropriateness: 1. Remove existing roofing material from building as necessary-, 2. Install two layers of 2/2" insulation, mechanically attached to roof structure; 3. Install a new 50 mil Duro-Last PVC deck membrane on the roof of building; as per the attached specifications and photos with the condition a permit is obtained from the Building Department. An approved Certificate of Appropriateness is not an approved building permit; a building permit is- / is not required. Contact the City of Grapevine's Building Department at 817.410.3165 for fees and information regarding permits. Thank you, n C David Klempin Historic Preservation Officer cc. Property Owner CA File THE CITY OF GRAPEVINE HISTORIC PRESERVATION • 636 South Main Street • Grapevine, Texas 76051 Phone 817/410-3556 - Fax 817/410-3038 CERTIFICATE OF APPROPRIATENESS APPLICATION & Rhone Number licant blame, Address & Phone Plumber Phone: r - --- Phone: i Obile; Mobile Email1�462Email: Pro ert Address inc/hudne an suite number L al Description G �P� I -. l + ► d l--I I C. �.o�Z __ Block �S Lot 14' % 4� I✓ ¢Iz or+ �i1y,{,{ 4A-!Yl 7 " RSubdivis}or. -!®l�' I Q� i,J, _ Tena flame/OccupAr cy/Use Request/Description of Work to Be Done Drawings/Sketches Attached Photo ra hs Attached Yes o No ot- Current o Historic Material Sample(s) Attached lease list 1 /P---tA1.- �L�..��_-�1I'►a..L��d fCClYl-oS- 1 Hereby certify that this information is correct to the best of my knowledge and that the said work will be done in conformance with all submissions herein set forth. and in compliance with the City of Grapevine's Historic Overlay District Ordinances and Building Codes. APPROVAL OFA CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF OTHER REQUIRED BUILDING PERMITS. Si ned x Print Name 7(CApproved Aror�on�fracto�r � r% Office Use PC Approved- with Conditions: Staff ---------------- -m c Pr'sB_rvali/o�n Q7ft r x _ gate-R--G-�. o� THIS IS NOT A BUILDING PERMIT, A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY THE BUILDING DEPARTMENT BEFORE STARTING WORK. DELIV�TO: HISTORIC PRESERVATION DEPARTMENT OFFICE 817-410-3556 636 SOUTH MAIM STREET, GRAPEVINE: TEXAS This form must be completed by the applicant for CASE N0. # A 010" NEW CONSTRUCTION, ADDITIONS AND RENOVATIONS DATE � 2 ;2- � SITE & BUILDING PLAN REQUIREMENTS Reference: Ordinance No. 2013-23 xA sjp,civ.jiml;niceo er vicw188i The following information is required for properties with Historic Landmark Subdistrict Overlays and/or properties located within the boundary of the Historic Grapevine Township District to make application for new construction, additions and renovations. Historic Preservation officer Consultation pate: 2 124 Time: Contact: (817.410.3197 817.410.3185) 1. Survey Plan 2. Site Plan 0 3. door Plans ❑ 4. Elevations ❑/ S. hoof Plan P� 6. Street Facing Elevations El of proposed structure with building elevations of structures on adjacent properties. 7. Photographs ❑ of any elevation for any building or structure to be altered or demolished Property lot Size `I 4 760 Square Feet Building Size (not less than 1,200 sq. ft. or greater than 3,400 sq. ft.) Building Coverage (40% max) Building Height (35 ft. max) Garage (Detached 50D sq. ft. max) NOT included in 3,400 sq. ft. - , __ _ (Attached is included within the 3,400 sq. ft. max) Storage Shed (200 sq. ft. max) For Commercial Uses: Impervious Area % of Lot Open/Green Space Area % of Lot Parking Spates ADA Parking Spaces Easements s PLEASE NOTE this page is for ALL NEW CONSTRUCTION & ADDITION APPLICATIONS for PUBLIC HEARING: 1, THE ABOVE INFORMATION MUST BE COMPLETE; WITH 2. ALL REQUIRED ATTACHMENTS COMPLETED; AND 3. A SCHEDULED CONSULTATION WITH THE HISTORIC PRESERVATION OFFICER IS RECOMMENDED SIX WEEKS PRIOR TO REVIEW BEFORE THE HISTORIC PRESERVATION COMMISSION. FORM: 0:HPC/CA"5/APPLICATI0N/CHECKLIST/2017 12/2/2020 Tarrant Appraisal District '5* <!1A 2a , f Account #: 01090798 � Location Property Address: 401 S MAIN ST Interactive Map City: GRAPEVINE LANDAIAT), Zipcode: 76051,.: Georeference: 16060-18-9 Neighborhood Code: RET-Northeast Tarrant County GeneralF-v•- Latitude: 32.9375735296 Longitude:-97.0781183721FRO"1117�' LY TAD Map: 2126-460 MAPSCO: TAR-028J Q Property Data Legal Description: GRAPEVINE, CITY OF Block 18 Lot 9 & 10 PORTION WITH EXEMPTION LAND & 2ND FL Jurisdictions: 011 CITY OF GRAPEVINE 220 TARRANT COUNTY 906 GRAPEVINE-COLLEYVILLE ISD 224 TARRANT COUNTY HOSPITAL 225 TARRANT COUNTY COLLEGE State Code: F1 Commercial Personal Property Account: 14283803 Agent: ACCORDING TO VALUE LTD (00550) Notice Sent: 05-01-2020 Notice Value: $508,974 Protest Deadline: 06-01-2020 Site Number: 80092462 Site Name: GRAPEVINE MASONIC LODGE #288 Site Class: ExCommOther - Exempt - Commercial Other # of Parcels: 1 Primary Building: Building Name: GRAPEVINE MASONIC LODGE#288 (LAND AND 2ND FL ONLY)/ Williams and Building Type: Commercial Year Built: 1950 Gross Building Area ttt: 9,000 Net Leasable Area ttt: 9,000 Land Sqft ♦: 4,700 Land Acres ♦: 0.1078 Pool: N ttt Rounded ♦ This represents one of a hierarchy of possible values ranked in the following order: Recorded, Computed, System, Calculated A Owner Information Current Owner: GRAPEVINE MASONIC LODGE #288 401 S MAIN ST GRAPEVINE, TX 76051-5328 Deed Date: 12-31-1900 Deed Page: 0000000 Deed Volume: 0000000 Instrument: 00000000000000 _�l C2,AZC)__)II 16t"2 David Klempin kC1 F ; --6 f j-I � �-/ l TAIL. i -DO�J. -C PO U P From: Donny Mahan <rdmahan@outlook.com> Sent: Thursday, January 14, 2021 9:57 AM To: David Klempin; Jeremiah Obert; dave.custable@trivanroofing.com Subject: Roof Lighting *** EXTERNAL EMAIL COMMUNICATION - PLEASE USE CAUTION BEFORE CLICKING LINKS AND/OR OPENING ATTACHMENTS *** David, As noted in a previous email, the roof lights have been removed from the Grapevine Masonic Lodge building in preparation for the new roof install. We are committed to continue to work with the parks department for replacing the lights upon completion of the new roof and will notify them at that time. Thanks, Donny Mahan Grapevine Masonic Lodge Sent from my iPhone O 1L CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE RELEASED _ PURSUAN T A DATE , BY.J9-1)_LL PA TMENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION A �� ��J-I ' 2 �1l 2®FZ David Klempin RO6F` n r m I H7 5 From: Jeremiah Obert Sent: Tuesday, January 12, 2021 9:41 AM To: David Klempin Cc: rdmahan@outlook.com; Mary Bush Subject: RE: Rooftop lights I'm still waiting on a response from the lighting contractor. I gave him another message today to remind him that I still need a quote. I'll let you know when I hear from them. -----Original Message ----- From: David Klempin Sent: Friday, January 8, 2021 1:58 PM To: Jeremiah Obert <jobert@grapevinetexas.gov> Cc: rdmahan@outlook.com; Mary Bush <mbush @grapevinetexasusa.com> Subject: RE: Rooftop lights Jeremiah, We do need to know the plan with time -frame for reinstalling lights. This needs to be part of the Building Owners written plan for light removal and replacement, so we can approve the Certificate of Appropriateness and the Building Permit can be released. David Klempin -----Original Message ----- From: Jeremiah Obert <jobert@grapevinetexas.gov> Sent: Friday, January 8, 2021 1:10 PM To: David Klempin<dklempin @grapevinetexasusa.com> Cc: To: dave.custable@trivanroofing.com <dave.custable@trivanroofing.com>; Cc: Tony Steele <tsteele@grapevinetexas.gov>; Donny Mahan <rdmahan@outlook.com>; buck.padilla@trivanroofing.com <buck.pad iIla@trivanroofing.com> Subject: Rooftop lights The lights have been removed from the building. The contractor will get me a bid on reinstalling new track and putting up the old lights once he gets prices and availability. The track that is still attached to the building can be trashed. So on our side we are all clear. Let me know if there are any further questions or concerns with Rooftop lighting. Thank you. Sent from my iPad 1 t —red A�`('�Y�r 3•""s�r:.t'�h =mom r �',� r ►�`3<,y'� �-Ca �+?-' �� .r �"rt�{ t� ° r r '�" r W �.+ ♦ �j .ST ��ew, {v�4- ��s` y� � y �`Jj,!� � i•' - g � 4r .;'fir .�e� ra�� � ~ i �., .�'q a R+sr�� .� r k� rti •... '�` f;^ ?. �j.. �K �. "�1 -' , rj ;y .J" �� ��� � ��� � ..�_ �13 _. -. � `� � rr •�,�-�w.`:.y;,,.� yr jay r, � d i. w_ ^ • .i.„ rJ ti ,.�',°'�c�. '� ^""._. s F d- "� C-4 Sent from my Whone CERTIFICA7F: OF APPROPRIATENESS 011`4 .)f GRAPEVINE RELEA 19- PUP630NTITO CA DATE By OF TOF DC-11ELOPMENT SERVIC68 CON"I'ACT BUILDING 1148PECTIONS FOR PERMIT INFORMATION j EXCE AV�� �.,-_ PRoaucr DATA SHEET AII®ierm "m Description: The All -Term- system may be used as a perimeter flashing for single -ply roofing systems. The system consists of a base and a snap -on metal cover. ® Base and cover are fabricated in 10' lengths; 4" — 13" widths. Ready -to -assemble inside and outside corners. ® Not sensitive to mil thickness. Energy Efficiency: LEED® and ENERGY STAR® compliant. Installation: 1. A wood nailer is required if 1" or greater of insulation is used. 2. This nailer should be attached to the wall in accordance with ANSI/SPRI ES-1 3.9. 3. Install in accordance with EXCEPTIONAL' Metals Detail #3580. 4. Any deviation from the requirements set forth in detail drawings must be pre -approved, in writing, by the EXCEPTIONAL Metals Technical Department. Codes and Standards: o ANSI/SPRI ES-1 Compliant with 4" —13" base and cover Warranty: EXCEPTIONAL Metals offers a finish and substrate warranty. Contact the membrane manufacturer for any additional warranty that may be offered. Technical Services: Product samples, detail sheets, color chips, and color chart are available for your submittal package. For assistance with questions or submittals, contact your local representative or call EXCEPTIONAL Metals. CERTIFIGAl E OF APPROPRIATENESS CITY OF GRAPEVINE RELEAS D PURSUANT T,0 A � — 1 DATE12 BY D PA TMENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION Baste Material Gauge Finish Aluminum .050 N/A Galvalume Plus 22 gauge N/A Cover* Material Garage Finish Aluminum .040 Mill or Kynar Stainless Steel 24 gauge NIA Bonderized Steel 24 gauge NIA Galvalume 24 gauge Mill or Kynar 9" — 13" widths available in .040 aluminum only "EXCEPTIONAL" is a registered trademark owned by Duro•Last , inc. "Galvalume" is a registered trademark owned by BIEC International Inc. "LEED" Is a registered traee.nark owned by the U.S. Green Building Council® and is used with permission. "ENERGY STAR" is a registered trademark owned by the U.S. Government. ENERGY STAR is only valid in the United States. Kynar is a registered trademark owned by Ark®ma, Inc. Created 0112812017 Revised: 02/0312017, 06104t2018 A2-o-ill Roof System Proposal For 403 S. Main Street Grapevine, Texas 76051 TriVAN Roofing Duro-Last' Elite Contractor 753 Port America Place, Suite 105 Grapevine, Texas 76051 www.trivanroofina.com 877-487-4826 License #03-0449 — RCAT Texas Endorsed #3146 — CIO Oklahoma CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE RELEA PURSU T 0 A DATE � 2 By � L D A ENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION Tri Z R z;Lm*-L4,sr `Fi 6 a F' "' G °° i Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 ® Table of Contents — Roof System Components Page 3 — Pricing and Proposal Inclusions/Exclusions Page 4 — Roof System Design Page 5 — Duro-Last® Warranty Inclusions/TriVAN Warranty Page 6-8 — Project Timeline Page 9 — The Duro-Last® Value Proposition Page 10 — Coping versus 2 Piece Compression — Next Practice Page 11-12 — Duro-Last® Prefabrication Process Page 13 — 50 Mil versus 60 Mil — Thicker is not Better Page 14-15 — Duro-Last® Green Roof Page 16 — Project Team Page 17 — Customer References Page 18 — Contractor Qualifications Page 19 — Duro-Last® Elite Certification Letter Page 20 — Licensed Roofing Contractor Page 21 — HAAG Certified Inspector Page 22 R o o F N G V Elite Contractor Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 ROOTS Stem Proposal November 20, 2020 1 Decking 2A Install 3 new Duro-Last® Roof System onto existing wood substrate 2 2 Insulation 7 Thickness Lavers Product Attachment 2 2" 2 Duro-Guard® II Polyisocya n u rate Insulation Board, Tapered Insulation and Tapered Q Panels Mech. Fastened 2A 1/4" 1 Duro-Guard® Hail Impact Rated Cover Board Mech. Fastened 3 Membrane Thickness Sq. Ft. Product Fastening Type 50 Mil 4,500 Duro-Last® DL50 Prefabricated PVC deck membrane Mech. Fastened 71 40 Mil 1,400 Duro-Last® DLP40 Prefabricated PVC parapet membrane Mech. Fastened 4 Flashing uantit Duro-Last® Prefabricated PVC Flashing Flashing Type 3 RTU Curb Flashing and roof hatch flashing Closed 3 Vent Through Roof Stack Flashing �\ .`�-� Closed 0 Exhaust Fan Curb Flashing Closed 5 Metals CLuanfity Size Exceptional Metals® Prefinished Prefabricated 24 Ga. 280 LF 6" 2-Piece Edge Compression Edge Detail 2 EA. Scuppers 3 EA Pitch Pans 6 Accessories/Additional Services uantit Products/Services 5 EA. Duro-Last® Two -Way Air Vents 1 EA. Duro-Trak® III Walkwav Pads vf�:ry 7 Warranties • Duro-Last® 15-Year Consequential Damage Warranty Plus Five No Dollar Limit for a total of 20 years • TriVAN Roofing Five Year workmanship warranty Elite Contractor Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 Proposal Inclusions • Preparation • Existing roof system is to remain in place, gravel is to remain in place • Scuppers are to be removed and replaced, downspouts are to remain in place • Wood blocking is included at the top of parapet walls to allow for proper metal fascia attachment. UP hting at the top of the parapet walls will need to he remnved and • Membrane • Deck— Mechanically attached 50 mil (28 mil over scrim) Duro-Last® PVC deck membrane • Parapet— Mechanically attached 40 mil Duro-Last® PVC parapet membrane • Insulation/Cover Board • Insulation — 2 layers of 2.2" insulation with an R Value of 25.2 • Tapered Insulation Crickets —As shown on attached roof drawing • Cover Board —1 layer of %" cover board for Hail Impact Class 4 Rating • Fascia • Metals 2-Piece Compression Flashing — Where shown on attached roof drawing in lieu of sheet metal coping. Grapevine Historical Society approval needed. Edge Detail — Included Pitch Pans — Included Brake Metal, Special Flashings — Included • Accessories • 2-Way Air Vents —One per 1,000 square feet as required by Duro-Last® • Walk Pads— 5 linear feet of walk pads are included in this proposal price • Other • Expiration - This Bid and pricing contained shall expire after 30 days due to material and labor pricing changes out of the control of TriVAN Roofing. • Terms - 50% mobilization, 40% at project completion and remaining 10% with issue of warranty • Equipment/Debris - This includes all lifts, trash removal, etc. • City Permit - Included Exclusions • Curbs - Price does not include any curbs or roof stacks that need to be extended to meet minimum height requirements for Duro-Last® roof system • Mechanical, Electrical or Plumbing—TriVAN Roofing is not responsible for the HVAC system, condensers, nor damage to any roof lines during course of our installation and recommend that your HVAC tech, at the owners cost be available if any service is required Trt 4 �i Q�� R 6 F ' ni G ` .�`' Elite �/� .ontracto Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 ROOTS stem Proposal November 20, 2020 Roof System Design The color coded drawing below represents our takeaway of the requirements based on our assessment of your roof. If it is not represented in this drawing or the Roof System Components on Page 3, they are most likely not included in our scope. We recommend a scope review to insure we meet your requirements and include all the elements you require in our scope prior to executing an agreement. Street access will require shut down. Roof Membrane Tapered Insulation Roof Top A/C Units ` Roof Drain 2-Piece Edge Details Walk Pad Awnings (Not Included) _- R 0 0 F i ^"' G ` Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof S stern Proposal November 20, 2020 The Duro-Last' No Dollar Limit Warranty INDl kVarranty The 20-year NDL with 15-year Consequential Damage No Dollar Limit Warranty provides the best coverage in the industry: • The Duro-Last®15-year no dollar limit consequential damage standard warranty provides the best coverage in the industry: ✓ This warranty covers damage to the building and its contents should the roof system fail during the term of this warranty ✓ Includes exposure to kitchen grease from kitchen exhaust fans and exposure to other chemicals ✓ There is no charge during the term of this warranty, no material, no repair labor charges, no monthly or annual maintenance charges, it comes standard with a Duro- Last® roof system ✓ includes deck and parapet membrane including edge metals and change of plane "Edge -To -Edge Deck -To -Sky" and all component parts for the life of the warranty including: ✓ Edge termination metals/fascia and termination bars ✓ Skylights ✓ Curb, stack, corner and parapet flashings and ATR hubs ✓ Drains, scuppers, downspouts and conductor heads ✓ Fasteners, adhesives and caulks ✓ Duro-GuardO ISO II- insulation panels, tapered systems, cover boards and crickets ✓ Walk pads and any other Duro-Last' accessories Includes all sealants and adhesives for the life of the warranty ✓ Includes poncling does not void the warranty unlike TPO which voids the warranty ✓ Chemicals and cooking grease do not void the warranty unlike TPO which begins to degrade when it comes in contact with these elements ✓ Transferrable to the next building owner TriVAN Five Year Duro-Last® Elite Contractor Warranty As a Duro-Last® Elite Contractor, we understand the most critical time for a new building is the first six months of operation. During this period it is critical that operations are not interrupted by issues such as compromised roof systems. Our inspections will be looking for any changes to the roof system, damage caused any weather or human intervention, any environmental conditions that may be affecting the integrity of the roof system, and any other systems residing on the roof that may impact operations, for example covers left off of mechanical units. This will allow you to provide your owners with the continuity of support and confidence that the roof system will be secure and will mitigate interruption of operations during that critical window of new building operations. Tr i 6 s ea -LAST - -' " F i N_.G `rc Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine., Texas 76051 Roof System Proposal November 20, 2020 20-YEAR —LAwitty No- DIUROS-T] SUPRIEW ND L Warranty 1.9 Years Come-quential Damages And 5 Years Material 1. TRIUM and CONDrr#ONS Dum-Lase I. ( -Duro-wo grants this No -Dollar Limit (-NDL-) Waywity to the owner of a building ("owner") containing a Dam -lam Roofing System (IDuro.-LastSystesn") instaftilby a Duro-Last widiorized the conditions and limitations contained herein. Duro-Last'sobit gationduri the 1-through IP yew shal be wrepair any leak in DomlAsiSyscin caused anydefect in a Duro-Last by the repo ip of the Conutictor, but only as the workmanship rtelirts to the installation 1, com of the itselfas st=r work performed, if any. Dum-Last's obligation includes, K Duro-LaWs of d= discretion, either the repair or replacement of part or all of the Duirti-Last System and also includes the furnishing or cost of labor to re;:i.rthe System provided the following conditions are met: and Contraaar have been ppaasrtd to full for the limo -Last System, its installation and any outstanding invokes issued by Duro L ass that arise after the 6srallation -Last System boo been d by Doro-Last fbVow**'m= by orized Amu Las QualityAmmance H. The Dorn 0 1: authorized Technical Cvuro-=wQA Tech Rep-), this No_ Har Wy'h:. h�. . by a Duto Last Quality Assurance bunager. !ad due Ca�wtor confirms that the Duro4.as System was inualied Czificamins and written installation mquivermerns; Owner has rictified Dum-Last within 7 days of the discovery of any leak. Duto-LastSystem defect. Owner must notify Dum4.astbycalling die alto-LAUQuahtyAmAraimeDepaMneWatt-86&284-9424.bye-maiting wa6du m-liaLcom. at by certified mail return receiptr gum ATec to the maincluding,if necessary, the = p removal and replacement by=at Owma s expense any and A] obstructions, including but not limitied to: rooftop gardens. earth, soil. pavers, ballast, docks, patio and other overburden, and 3 E.Duro-Last authorizes the repair and, at makes the repair. During the 1-throtigh 151 year of this No -Dollar LimitWarranty, 0wria and DurolAst agree (hat this No -Dollar Limit Warranty oov- an incidental and con. qrenti.1 damages derived from leaks caused by defects warranted against above. During the 161through 2D* year of this No -Dollar Limit Warranty term, Owner and Duro-Last Wee that Dum4A%t shall am warranty the worlanar"hip of the Contractor, and that Dwo-Last shall only warranty that the Duero -Last Symern inwrebrane, material and accessories) will not become J defective. Furthermore, during the 161 through 2DI year of the No -Dollar Limit Warranty, Owner and Du m-Isat agree that Duet -Lau shall not be responsible for any incidental or consequential damages, including but not limited to any loss of profits, loss of use of the 4buit my din to the bwkh c mariner set forth above, - prior to ft first of claim tar 0=c==&==�ro=aos!(hdmmJs waived. th717 year, any building It. OWNER'S RESPONSIBILITIES The Owner is not entitled to recover under this No -Dollar Limit VAuranty oaten Owner exercises reasonable and diligent care in the maintenance ofthe Duro-LutSy3wra. including but am ImLited to inspecting and maintaining the Dum-Last System regularly mid as needed, including after storms or mutual disasters, and for debris from ft Dino -Last Sysusn, rooftop, and adjacent areas, and maintaining and keeping all "as in i�� T14'."d '��= debris and other obstructions. III. LIN TIONS and EXCLUSIONS A:This No -Dollar UmitWdoes not apply to a Duro,­Last System instialledoo a single-family zesidemce. B. Dino -Last shall not be liable ttr damages arising from defects in the design or conmuction of the building or the rod nor shall Duro-Last be Kahle for any other products wide from the including itrAdequate or insufficient drainage, System. C. Dario -Last is not liable for imy Duet -Last System defect or failure not for subsequent damages arising from Acts of God or causes outside Duro-LoVs control iockiding, bit not limited to. it Damage cursed by fire, tighinang. hurricane, p)e!, hail, mmado, flood. earduluake. 2nimah, insects; or, 2) Damage caused by accident. vandalism intentional act. negligence or failure to use reasonable cue, whether on the part of thud or another, or, 3) arty n unauthorized moddicsfion to the Duro-Last Systesn including, but not limited to: damage =by==.Yd components used in installation or repair, by additional equipment or structures added to or made apart of the toot, by mffic, or by chemicals not normally found in more or the bw or 4) Interior condensation andAor moisture entering the Ludo-lAst System h walls, copings, structural defects, HVAC sysitems, cc any pan of the bu Mug strict re, mckuhn from at1j&=t =bu' D.Duro-Lastdoes am warrant the watLnightnewofinend products that we located outside of (ere termination of the DAm-Las membrane. E.DumlLw does not warrant against color charW and/or pattern change and/or print change in the Duro-LastSysteem. F. Duro-Last shall have no liability under any theory of few for my claims, repairs, or other damages reJadng to the presence of adiestas or ts, finties, molds. funtbacteris, spores, myoDtDxins, or the like on cc in the Duro-tint System or in the building or r= or water serving the. lifing. G.ThisNo-Dollar Limit Warranty istransfes-able to subsequent Owners only upon the express written consent of Dum-Las and at Duro-Last's sole discretiom Duro-Last reserves the right to mquire an inspection of the Duo -Last Sr traw, . =nor to er _-j of this No -Dollar Limit Warranty. The Owner (undemWoed below) rant pay a $500 warranty transfer , most pay for any non -warranted repairs identified by Dum-Last during any pretrilrdfir inspection. A transfer ofthis No -Dollar limit Wzmruy shall rat be effective unless all outstanding Duro-Last invoices ban been satisfied. H.Thia No -Dollar Limit Warranty most be =d by a Duro-Last QiulityAssunmce h4anager, Covenige ter the terms of this No -Dollar Limit Warranty begins on the ve Doe. The Effective Date is determined by Duro-Last Failure of the Owner or Contractor to sign this No -Dollar Limit %tranty does not aker the Effacti ire Date. OVER: CONTINUED ON BACK Q?", Tee EVAIN, 7 ST Elite Contractor 0 1 r4- 6 Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 t . - Y , 1. Ibis No -Dollar Limit Wermnty shell be governed by the laws of the State of Michigan wiftut regard to principles of corAkts of law. Dum_Lau and Owner hereby zsee that the Circuit Cowt for the County of Saginaw, Use of Mkitigan, or the Unhad States Federal District Cams for the Fasters District of Michig m in Bay Cdy, shall have the euitativa puisdictioa to deternalm any and all disputes, or chins relating to this No-13DIW Lknit Wwramy and do hereby submit themselves to the sole personal jurisdiction of down Coum J. Noclsim, sot, or other graceeding arising out of or related to the Demo -Last products or these terms, including widwvt Imitation this No -Dollar DSnra Warranty, may be brought by the Owner or amine else stw one (1) year from the elate it awmes. K. Dumo-Last does not waive any rights user this No -Dollar Unit Warranty by refraitring m exerdse its rights in full in one or ram ostances. THIS NO -DOLLAR LANIT WARRANTY AND THE IIESSPONSIDtL(TIES ANSI REMEDIES STATED H ERM ARE EXPRESSLY AGREED TO BY OWNER AND DUR04 AST AND CONSTITUTE THE SOLE WARRANTY AND BEMED]RS OF THE OWNER FOR ANY ALLEGED DEFECT OR FAILURE OF THE DUROd.AST SYSTEM, WHETIM MEMBRANE, ACCESSORIES, OR CONTRACTOR WORKMANSHIP. THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (EITHER EXPRESS OR IMPLIED IN FACT, LAW OR CtNMM )THAT EXTEND BEYONDTHE EXPRESS TERMSSTATED IN THIS NO-DOII AR LIMIT WAR. RANfY TO THE FULL EXTENT DISCLAIMER IS PERMITTED BY LAW. OWNER AND DMO-LAST TOGETHER JOINTLY DIS- CLAIM ANY OTHER OR FURTHER WARRANTIES EXCEPT THOSE INCLUDED IN I= DOCUMENT. IN ANY EVENT, ANY IMPLIED WARRANTYTHATMAYARISERYLAW IS LAHTEDI ND1RtATIONTOTFETERM HEREIN. THEREPAULOR REPLACE. MENPT PROVIDED HEREIN IS EXCLUSIVE AND IN LIEU OF ALL OTHER REMEbIFS ALL CLAIMS FOR NEGLIGENCE AND FOR FAILURE OF ESSENTIAL PURPOSE ARE EXPRESSLY WANED, RELEASED AND EXCLUDED. OWNER AND DURCM.AST BOTH AC KM% LEDGE AND AGREE THAT DURING THE r TIIROUCHD 191 YEAR ONLY, THIS NO. DOLLAR LIMIT WARRANTY COVERS INCIDENTAL AND CONSEQUENTIAL DAMAGES DERIVED FROM LEAKS CAUSED BY DEFECTS WARRANTED AGAM ST ABOVE. OWNER AND DURO,I.AST BOTH ACKNOWLEDGE AND AGREE THAT DURING THE 16s THROUGH 20- YEAR OF THIS NO - DOLLAR LIMIT WARRANTY, DURO-LAST SHALL NOT WARRANTY THE WORKMANSHIP OF THE CONTRACTOR, AND THAT DURO-LAST SHALL ONLY WARRANTY THAT ITS PRODUCT MEMBRANE, MATERIAL AND ACCESSORIES WILL NOT BECOME DEFECTIVE. OWNER AND DUROd.AST BOTH ACKNOWLEDGEAND AGREE THATDURING THE M-THROUGH a- YEAR OF THIS NO DOI. LA t LIMIT WARRANTY, DUR ►LAST WILL HAVE NO LIABILITY TO ANYONE FOR CONSEQUENTIAL. SPECIAL, INCIDENTAL, WDIREC'T, EXEMI-LARY.OR PUNITIVE DAMAGES OFANY KIND WHATSOEVER, INCLUDING WMIOUT LMITATION PROPM- TV DAMAGE, LOW PROFITS, LOST USE, LABOR C(WM OR ANY OTHER PFE'UNIARV DAMAGE, WHETHER DUE TO ANY DEMCT IN THE PRODUCTS, BREACH OF THIS AGRB$MENT, DELAY, NON -DELIVERY, NON-PERFORMANCE, RECALL OR ANY OTHER REASON. THERE ARE NO THIRD PARTY BENEFICIARIES TO THESE TERMS. OWNER ACKNOWLEDGES THESE LIMITATIONS AND WAIVERS, DECLARES THAT THEY HAVE BEEN READ ANDUNDUSTOOD,ANDAGREES TOHESOBtiJ ANYPAYMENfFOR THEDURO-LAST SYSTEM OR REGISMATION OF THE WARRANTY WITH DURO-LAST SIGNIFIES THAT THE OWNER HAS VOLUNTAN LYAND IINOWINGLY CON'tENTPD TO AEI. TEI M-4. The Contractor is not an agent of Duro-Lost and does ant Eavt wulsarky to bind Duro-Law. if any Contractor or asks native made any statements aboua DuroLau, ks Products, services, obligations, or warnmaies,:base starts cannot be relied upoo by Owner or other puny sod canna be attributed to Duro-Last. Furdaermose, to person may change errd moty any term or condition of ads M-Dbn" Limit Warranty unless in writing and signed by the adbotind tepesentat)me dthe Owner and by a Dora -Lam dfioex or by the Duco-Las Quality Assurance Manager - SOW STATES DO NOr ALLOW LIMITATIONS ON HOW LONG AN DMILIED WARRANTY LASTS,SOSUCH A LEMTTA- TION MAY NOT APPLY 7O YOU. THIS WARRANTY GIVES YOU SPECWIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHT'S THAT VARY FROM STATE TO STATE. If any prmisiou or individual tears herein is invalid or etaenforocabk under any applicable law, the p *visice or tam will be ineffective to that extent and far dr duration of the ilkplky, but rise reamaidvS provisions and terms will be unalreeted. *,r Name of Bdltfmg AddreBs of Building { { g CRY, Stale & Zip d Bdlfffng 4, ` Building Designation EffecDve Date Swill No. DURO-LAS O, INC. •'µr 525 Morley Thrive Saginaw. MI 48611E Slonsamre of Doro•Laa QA Manage Signamm of Owner Own f T%+^'a¢".'.r..._.:%wY,f'":"---..�.""�:..:.. f (,' 1 ignsture of t.`Antrwtor �* or Sgn€mre Footage P, Warranty No. .. , '`,� +� z��xes �-� �� •• 'sue'g�yz.an 7A...15. 0 F I N G Id : Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 Project Timeline 1 Scope Review, accept proposal 2 Execute Agreement, provide submittals 3Field measure deck, parapet membrane and s flashings to confirm accuracy against plans Order prefabricated materials — prefab sections, 4 inspection #1 in the factory before shipping 5 Trades Meeting - Roofing, HVAC, Plumbing, Streets 6 Begin implementation (estimated 15 working days) 7 Inspection #2 — Post installation inspection 8 Inspection #3 — Duro-Last° final inspection and 1�'-'J issuance of the Duro-Last® warranty Please Note - All material, labor, tools, equipment and installation will be provided by TriVAN Roofing to deliver, install roof systems in accordance with OSHA requirements and remove any roof deployment waste material from the project. Noise will be limited to generators and use of hand tools. Hammering or drilling may cause vibrations causing items on walls to shift or fall. Safety cones and/or caution tape will be provided by TriVAN to block off restricted work areas. Property owner will provide exterior access to regular water faucet for water and electrical sources. Tr i VAN s � DU90#,L, #. ►' ' jwr a 0 0 F I N G L,"'Z, Elite Contractor Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 Warranty - Duro-Last® is the only roofing manufacturer that offers a 15- Year Consequential Damage (standard with DL50 Membrane) No Dollar Limit No Deductible Warranty. If their roof leaks and damages the building or its contents, Duro-Last® pays. The warranty also includes exposure to kitchen grease and water ponding which no other manufacturer supports. Vertical Product Integration —The Duro-Last® warranty extends to every system component and doesn't stop at the vertical plane because they make them or OEM them from the manufacturer. It 4R includes fasteners, vent and curb flashing, insulation, edge metal, scuppers, standing seam, even gutters and downspouts! No other roofing manufacturer offers such coverage. N!3L Warranty 10 Membrane Fasteners m Insulation Oil/Grease t F c" "o 0 Longevity — All manufacturers make claims about the quality of their product. Only Duro-Last® has the distinction of having the same proven formula in their membrane for 41 years. The longest a TPO formula has been in the market is 9 years. Consumer Protection — Quality is deeply integrated into the Duro-Last® process. — Prefabrication -Duro-Last® is the only roofing manufacturer that prefabricates its membrane, flashing and metal edge details in their manufacturing facilities throughout the country. Robotic technology is used to weld 85% of the seams and 100% of flashings under environmentally controlled conditions significantly eliminating the margin for error of field installation almost entirely, especially relevant in Texas. What remains is controlled by their best -in -class installation and inspection process. — Installation —Duro-Last® maintains strict oversight of every step of the Duro-Last® Roof System installation process. TriVAN's installation and practices are graded to insure the highest standards for deployment are maintained in accordance with Duro-Last® design specifications. /Edge Metals Scuppers Gutters Downspou' Ponding — The Duro-Last®Inspection —Every Duro-Last"installation goes through a rigorous inspection that can last days not hours. Ever seam, weld, flashing, curb, fastening pattern, edge metal detail, termination bar is checked to insure the installation meets their best practice specifications to make sure the installer "makes the grade"! Safety — One of the most underappreciated elements of roofing is its flame- spread rating. This is the propensity of a product to catch and spread fire. The Duro-Last° roof membrane is the only roof system that is naturally fire retardant Class A because PVC is derived from salt not petroleum like other membranes such as TPO Class C. When lives are at stake, Duro-Last® is the safe choice. Green —The Duro-Last® Roof System "cools" the roof temperatures and this can reduced energy expenses by 30%. This in turn reduces heat load extending the useful life of your HVAC systems. Duro-Last® �� Cac.�r~7_'ic�n;�� is also the only product that is 100% Recyclable! ''.. R 0 0 F t N- G f� t.C4 Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof Systern Proposal November 20, 2020 Coping Versus 2-Piece Compression — Next Practice We recommend the Duro-Last® 2-Piece compression system be used to terminate the membrane at the top of the parapet rather than coping cap. The membrane is fastened only on the outside of the parapet wall and meets or exceeds ES-1/ASCE-7 "Current" Standards to 90 MPH. Systems using coping caps require termination of the membrane through the top and inside of the parapet as shown below and this introduces points of failure into the roof system design. This is exacerbated by the fact that the coping itself requires a seam every ten feet and at corners. Each seam requires caulk to seal these seams that shrinks and fails within just a few years. The Duro-Last® Roof System eliminates both these issues completely. Duro-Last° 2-Piece Edge Terminated on Outside Wall 2-Piece edge detail = Parapet wall warranty Membrane Penetrations Traditional Coping Cap Inherent Maintenance and Upkeep Coping Cap = No parapet wall warranty lllll!!� TriVAN 13U)WIAST POOR Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal• •- EX EI� 1�] AU PRODUCT DATA SHEET ,'T� VersaTerm r, Edge Description: The VersaTerm " Edge system may be used as a perimeter flashing for single -ply roofing systems. The system consists of a base and a snap -on metal cover. • Base and cover is fabricated in 10' lengths: 4' —13' widths. • Base 22 gauge Galvalume Plus and .050 aluminum. • Cover: 24 gauge Gatvalume Plus and 040 aluminum_ • Ready -to -assemble inside and outside comers. • Not sensitive to mil thickness. Energy Efficiency: LEEDP and ENERGY STAR" compliant. Codes and Standards; • ANSnPRt ES-1 Compliant with 3" 8' base and cover. Installation: I A wood nailer is required if V or greater of insulation is used. 2 This nailer should be attached to the wall in accordance with ANSYSPRI ES-1 3.9 3 1rastall in accordance with EXCEPTIONAL'' Metals Detail #3:580. 4 Any deviation from the requirements set forth in detail drawings must be pre -approved, In writing, by the EXCEPTIONAL Metals Technical Department Warranty: EXCEPTIONAL Metals offers a finish and substrate warranty. Contact the membrane manufacturer for any additional warranty that may be offered. Technical Services: Product samples. detail sheets, color chips, and color dart are available for your submittal package For assistance with questions or submtttais, contact your local representative or call EXCEPTIONAL Metals, Madar9al Gau a Pintsh Aluminum .040 Mill or K nar' Stainless Steel 24 Gayaa NdA Bonderied 5fee1 S'f —gouge I NIA ° Galvalume 24 due l Mill ortC r ar covper 16 oz. Mill "4'++Iratas!-aM "S%GEP110NAL'—1.9f"—d t d.—rko —md by ikerW.abi . r sc "Gr"wltm.r- i. o n9i.ton i tadt t% w tmd by a4K klWmk/iortwi N -4EE8" +• a registered "d m6rk --d by Ow U.S. Gcow Bun pM Catarlc4l ad 1. as•d wtih parmiss:an.--SNEngy STAR" to a mgt Wa d Iradtanark awned by M. U.S. Govrranxrt ENERGY STAR is ctt y v*A4 in M* U1Yt•d Stab". Nyriaris a reglsumd traa--* awrmd by dw Arka Gralap.. C-aiad of f1A'207 0 Elite Contractor Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof S stem Proposal November 20, 2020 Prefabricated Roof Membrane Layout Versus TPO Below is an example of the engineering design for prefabrication of the Duro-Last® Roof System that will be completed for your Roof System. The blue lines represent seams fabricated in their Carrollton, Texas fabrication plant (one of four in the US) using automation under strict environmentally controlled conditions (see photos below or come visit the plant!). The dotted red lines represent prefabricated sections, welded together in the field by TriVAN's Duro-Last® Elite Contractor team. By comparison,100% of the blue lines would be welded in the field with TPO, significantly increasing the margin for error in the implementation process. Each roof system goes through a three stage inspection/quality audit (see Page 8) as an integral part of the deployment process before a warranty is issued. Duro-Last® Elite Contractors are graded on each installation and must maintain a high grade (92 or better) to keep their status with Duro-Last®. By comparison TPO contractors are not held to this standard. It ;I Itf� l F 5 A f 1{p-A..J-� +k� 46 I (� 1 i 7{jt ! _��_ Tit ikj 9 l i j{j9q tt 1 i � � A -- t 1(! Fit qi I F 7_ 4 t, a — I i ;tsg t1 �•f FT— T t _ I 'q �1� T 3 .14 I fk i {`a t s� p;` fit !�. jj(2 '+ r4 L A!{ 1 t! i AI { ; a 3' I i}i ii ii � t �.� Y i 4 t ?3 E i 1 i apt tct �1" A�} � Z1 t3i i 4is= i2 i 14-a}t# L I A I I f I rEV/, R O 0 F 1 N 6 13 ctor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof Svstern Proposal 50 Versus 60 Mil Membranes While it's commonly believed that thicker membranes offer superior protection, it's important to note where that thickness comes from. The top layer of a membrane - also known as the "performance" layer - is the most vulnerable. With daily exposure to harsh natural elements like UV rays and unpredictable precipitation, to regular foot traffic from mechanical and building maintenance, membranes with inadequate performance layers are susceptible to accelerated deterioration and damage. Duro-tast®s 50 mil flagship membrane is manufactured with 28 mil of thickness on the top performance layer, far exceeding industry standards as well as competitor systems with equal and even greater mil values. In fact. ASTM 4434 industry standards require only 16 mil of thickness above the scrim reinforcement, allowing for extra filler material to be added to the bottom layer to increase overall membrane thickness. This means that while competitor membranes will be the same thickness, or even thicker, than Duro- Last's overall, they don't offer protection where n counts. 14 U- rn O T r i V 14 jR ` r -- r3 6 0 F ' N 6 ' Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 TriVAN Roof System — Membrane Composition R o o F I "' G Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 NZIMMEMEMORDuro-Last° Green Roof The rath to a n R o f b: fer, U Duro-Lash' an NSF/ANS 47 The roof is a huge part o uilding r -- project, and as the imperative for g "greener" buildings grows, there is greater � pressure to find an environmentally sustainable roof. But sustainabitity ` for membrane roofs had never e previously been quantified. rk9..Y`(fRn9ard PS@U-C2 [44(=.i ftV 8i1v@r9 M', t3s�1 I[fn CtHCi';, r m.; s#eut 111.11 arpertizallons 347 anaamifwsaad documem WlSr. AnSII mwN rvofiun gaailzie W eecb mdustr, Wake mmors- ..5raae roofing material. o Architects ?rYlgvitnd Lhicride IFVC) - - '° Boring consultants . Thermopiwnt pol' Wr-Xm YTP0, • Eng,nearz ® Mylane prap,.,:te'?* drone z 7 e Non-W.emment oraa.ILat4,ns - terpolt„nter volnw _ - s i':nanufacturers ® xrtos "i —ne eater WE£' . Poly rsait5^�estF7S� orxructs , e x f �lfi}C d13i%7ZL'CYSS f&1'rESjbRLr$i@ ii 24lsmtu.fggntg9s: ' .cr � 1#ilA3rY drtdnAGeAi`A TM ft6tiAMrb = . ,J1(i Vtskye' �. • Y, t„TYt_ h''iiiWfCff3la4$��*3 e#lY.31:57gy+-' II E' 1 • Want to Learn More? For more information about NSF/ANSI 347 and g�+ Duro-Last's Platinum certification, visit 19 duro-fastcom/sustainabililyor contact us at 866-735-R824. THE WORLD'S REST ROOF "Duro-Last and the-Wwld"s6 st Hoar— registered trade—Ax O—W tryDLas, frc. N4F367 tri Cgraphc Flyer 17 71 t6 - DL740025 Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 TriVAN Team Sherry Custable - Owner 817-891-7313 x1007 sherry.custable@trivanroofing.com Dave Custable — Vice-Presdient 817-891-7313 x1001 dave.custable@trivanroofing.com Ricardo "Buck" Padilla — Superintendent US Marine Corp, Veteran 817-891-7313 x1009 buck.padilla@trivanroofing.com Rob Perdue — Lead Estimator 817-891-7313 x1010 Rob.perdue@trivanroofing.com 753 Port America Place Suite 105 Grapevine, Texas 76051 ww%&#.TriVANroofing.com License #03-0449 — RCAT Texas Endorsed #3146 — CIB Oklahoma 17 ' ` ,` Elite Contractor Masonic lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof S stern Proposal November 20, 2020 Customer References Please visit our website @ www.trivanroofing.com/commerciai to view photos and expanded details of current projects completed or in progress. Movie Tavern Duro-Last® 50 Mil Single -Ply mechanically fastened Bedford, Texas Duro-Guard® ISO If 6" R-35 Insulation mechanically fastened Contact: Jerry Dinsmore Duro-Guard® ISO Tapered System to drains Tel: 817 768-6414 Exceptional Metals 2-Piece Edge Metal Details Tie new building into existing buildings Mustang Properties Duro-Last® 40 Mil Single -Ply membrane (Behind Main Event —Grapevine) Duro-Guard® %" fanfold underlayment over existing modified Grapevine, Texas 75061 bitumen roof Contact: Troy Davis Exceptional Metals 2-Piece Edge Metal Details Tel: 940-241-2419 Main Event Duro-last® 50 Mil Single -Ply mechanically fastened tear off Grapevine, Texas 76051 Duro-Guard® ISO II 4" Rigid Insulation mechanically fastened Mike Winter Duro-Guard® ISO Tapered System to scuppers Tel: 469-661-2695 Exceptional Metals 2-Piece Edge Metal Details First Baptist Church Duro-Last® 50 Mil Single -Ply mechanically fastened tear off Grapevine, Texas 76051 Duro-Guard® ISO II 4.2" R-25 Insulation mechanically fastened Brad Haile Duro-Guard' Cover Board mechanically fastened Tel: 817-488-8573 Duro-Guard' ISO Tapered System to scuppers Exceptional Metals 2-Piece Edge Metal Details Wright Group Architects Duro-Last® 50 Mil Single -Ply White membrane over existing 1110 S. Elm Street spray foam roof Carrollton, Texas 75006 5.8" Densdeck® Protection Board for Class 4 Hail Rating Contact: Terry Wright Exceptional Metals' 2-Piece Compression Edge Detail Tel: 972-242-1015 Exceptional Metals® Gutters and Downspouts f Cambria Hotel Duro-Last® 50 Mil Single -Ply membrane Adhered Southlake, Texas 76092 Duro-Guard® ISO 114" Rigid Insulation Adhered Links General Contractors Duro-Guard® ISO Tapered System to middle drains Adhered Tel: 940 566-5465 Exceptional Metals Columns, soffit, 2-Piece Edge Metal Details MBCI Soffit metal and MBCI Standing Seam metal F -N _Y R_ 0 0 F k G ' Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof S stem Proposal November 20, 2020 Reasons To Choose TriVAN TriVAN Roofing - Founded 2001- by Dave and Sherry Custable Certifications Duro-Last® — Duro-Last® Elite Contractor (only 12% of Duro-Last® contractors receive this designation) — 2014, 2015 Presidents Award Winner ` — www.Duro-LastO.com • Exceptional Metals® /MBCI® Metals Metal Roof and R'all Systems — Weathertight Certified Installer • GAF o�HYWcan� — Certified, License ME21251 i framWAAme wWffgm — Green Roofer Certificate °&M- • Shingle Green Roof Recycling Certified • Maintains Code Compliance Insurance including general liability, auto liability, and workers ft--r6:.w At compensation • Approved to install roofs for historical buildings (Picker's Universe)' • Texas Interlocal Purchasing System (TIPS) approved Vendor THE $17MCM PURCHASING SYSTEM Affiliations NORTH TEXAS • North Texas Roofing Contractors Association (NTRCA) ROOFING — Dave Custable, Past President, current board member CONTRACTORS — Accredited ASSOCIATION — www.NTRCA.com who's on your roof; • Roofing Contractors Association of Texas (RCAT) Cahill�• — Dave Custable, Board of Directors/Elder — License No. 03-0333 for flat and steep slope roofing t — Accredited — (www.rooftex.com) • Oklahoma Construction Industries Board (CIB) • — License No. 80003146 • Better Business Bureau — Accredited A+ • Texas Real Estate Commission — Licensed Instructor#987 Training Credentials Razing Licensed Trainer by Texas Real Estate Commission = — Roof System Components 11 Certified Trainer for the Texas Department of Insurance Fraud Investigative Unit and National —r—> Insurance Crime Bureau — How to Identify and mitigate scrupulous roofing practices • HAAG Engineering Certified Commercial Roof Inspectors t INSPECID Amumb RIB.CMAR OF. STAY• AND Ili AT Tr VA N �' DUJW>L.4S` "' R0 0 F ' N G19 elite Contractor M01I�LIROA,-LAST ,10 January 14, 2020 TriVAN Roofing & Waterproofing 753 Port America Place Ste. #105 Grapevine, TX 76051 Dear Valued Customer: I am pleased to inform you that you have earned the highest quality distinction given to our contractors, the "Elite Contractor Award". This achievement has placed you in the top 12% of our contractors, consistently installing the highest quality roofing systems in 2019. To achieve this award, you have installed and Duro-Last has inspected over 150,000 sq. ft., scored in the `outstanding' category on all commercial installations, and warranted five or more commercial jobs in 2019. In other words, you have worked your way to be the "best of the best" through your commitment to quality, dedication to detail, and hard work. Congratulations! Duro-Last may produce the ' World's Best Roof®", but we rely on your expert workmanship to ensure a high -performing, long lasting roofing system. Again, congratulations on a job well done. We are truly honored to work with contractors like you, who value quality as much as we do. Sincerely, Mitch D. Guettler Director of Quality Assurance & Warranty Services kit 525 M orley Drive, Saginaw, MI 48601 Phone: 800-248-02f•0 - Fax: 800-432-9331- www.duro-lastcom Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System -Proposal November 20, 2020 COMMER(L-11AL & RESIDENTIAL 1,10ENISED ROOFING CONTRACTOR Sherry Cus-table. CRRL has swmusfutly Inet all Ove retU4, rt*lfte Utle lulld conditionr, w becom-P liomnant by thy, Roofing Cautrwtam Asnodation of Texux W (E N S F NUNI B E H: LICENSE VALIDTHWOU�CAP 3131120211 &KWA IN$ k,I I r I #Vt A � rAp `'i TriVAN 21 �Dupa'' Twl ij- -W--a a Elite Contractor Masonic Lodge Grapevine 403 S. Main Street Grapevine, Texas 76051 Roof System Proposal November 20, 2020 w TriVAN ` o _o ' " G 22 Elite Contractor