HomeMy WebLinkAboutSFRA2021-0889JOB ADDRESS:
LOT: 13A
DATE OF ISSUANCE: c G
t PERMIT #:
BUILDING PERMIT APPLICATION
1064 Lavon Dr Grapevine TX76051
BLOCK: 1 SUBDIVISION: Lake Pointe
M BUILDING CONTRACTOR (company name): Titan Solar Power TX
i CURRENT MAILING ADDRESS: 525 W. Baseline Rd.
CITY/STATE/ZIP: Mesa, AZ 85210
PROPERTY OWNER: Randall Jackson
CURRENT MAILING ADDRESS: 1064 Lavon Dr
CITY/STATE/ZIP: Grapevine/TX/76051
PROJECT VALUE: $ 41514
SUITE #
PH:# 480-226-6769 Fax #
PHONE NUMBER: (214) 668-3759
FIRESPRINKLERED? YES
WHAT TRADES WILL BE NEEDED? rrn ELECTRIC X PLUMBING
DESCRIPTION OF WORK TO BE DONE: Installation of12.58kW rooftop solar
USE OF BUILDING OR STRUCTURE: Single Family Residence
NAME OF BUSINESS: Titan Solar Power TX
NO
MECHANICAL
Total Square Footage under roof- Square Footage of alteration/addition: 661 sq Ft
❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings,
alterations and additions)
❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: (Not required for I & 2 family dwellings)
❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S). Erica Ford Digitally signed by Erica Ford
PRINT NAME: Erica Ford SIGNATURE Date'2021021912'4214-05`00'
PHONE #: 480-226-6769 EMAIL: efordC&titansolarpower.com
❑ PREFERRED TO BE CONTACTED BY E-MAIL
Construction Type: t/B Permit Valuation: $
Occupancy Group: 9-'j Fire Sprinkler: YES_ NO Lk -
Division:
Building Depth:
Zoning:
Building Width:
Occupancy Load:
Plan Review Approval
Date: 3/16'�:,1
Site Plan Approval: L� tt//
Date:
Fire Department:
Date:
Public Works Department:
Date:
Health Department:
Date:
Approved for Permit:
Date:
Lot Drainage Submitted:
Approved:
P 0 BOX 95104, ORAPeVINS, TX 760M (817) 4103165
Setbacks
I Approval to Issue
Front:
Electrical ✓
Left:
Plumbing
Rear:
Mechanical
Right:
Building Permit Fee:
iQ GtiJ
Plan Review Fee:
Lot Drainage Fee:
Sewer Availability Rate:
Water Availability Rate:
Total Fees:
j 00
Total Amount Due:
? D et?
0 FORM SPEBMITAPPLICATIO"
Issue Date:
HAR 15 2021 CITY OF GRAPEVINE
c °-r
MECHANICAL - ELECTRICAL PLUMBING - IRRIGATION - FUEL GAS
PERMIT APPLICATION
_ (PLEASE PRINT LEGIBLY - COMPLETE ENTIRE FORT:
PERMIT # BLDG. PERMIT # ( DATE: 1211912021
JOB ADDRESS: 1064 Lavon Dr Grapevine, TX 76051 SUITE #
DESCRIPTION OF WORK: Installation of 12.58kW rooftop solar, LINE SIDE TAP
PROPERTY OWNER: Randall Jackson CONTRACTING COMPANY: Titan Solar Power TX V'r
ADDRESS: 1064 Lavon Dr ADDRESS: 525 W. Baseline Rd.
CITY/STATE/ZIP: Grapevine, TX 76051 CITY/STATEPLIP. Mesa, AZ 85210
PHONE NUMBER: (214) 668-3759 PHONE NUMBER: 480-226-6769
TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES
EACHTRADE
I. R-3
1 - 749
$
33.25
SINGLE FAMILY, DUPLEX
750- 1,199
$
49.88
TOWNHOUSE,
1,200- 1,500
$
63.18
NEW CONSTRUCTION &
1,501 - 1,750
$
76.48
ADDITIONS (PER UNIT)
1,751 - 2,000
$
83.13
2,001 - 2,250
$
89.78
TOTAL SQ. FOOT UNDER
2,251 - 3,000
$
96.43
ROOF
3,001 - 3,500
$
103.08
3,501 - 4,000
$
109.73 $
4,001 +
$
120.37
EACH TRADE
II. A, E, I, R-1
1 - 500
$
37.00
HOTELS, APARTMENTS,
501-100,000
$
17.50+.035
PER
DRINKING/DINING,
100,001-500,000
$
3,500.00+.03 SQUARE
EDUCATIONAL, ASSEMBLY,
500,001 +
$15,000.00+.02
FOOT $
INSTITUTIONAL
EACH TRADE
III. B, F, H, M, S, U
OFFICE, RETAIL, WHOLESALE,
1 - 500
$
37.00
GARAGES, FACTORIES,
501 - 50,000
$
32.00+.01
PER
WORKSHOPS, SERVICE
50,001- 100,000
$
182.00+.007 SQUARE
STATIONS,
100,901+
$
582.00+.003 FOOT $
_WAREHOUSE
CONTRACT
EACH TRADE
IV. ANY OCCUPANCY GROUP
VALUATION OF
WORK
FINISH -OUTS,
SHELL COMPLETIONS,
0-
500
$
37,00
ALTERATIONS OR
501-
1,500
$
45.00
STAND ALONE PERMITS
1,501-
3,000
$
57.00
3,001-
5,000
$
72.00
CONTRACT VALUATION OF WORK:
5,001-
50,000
$
27.00+.009
50,001- 100,000
$
127.00+.0( PER
$
100,001-50QOW
$
327.00+A05 DOLLAR
500,001+
$ 1,327A0+.003
VALUATION
�
EACH TRADE
MISCELLANEOUS
IRRIGATION SYSTEMS
$
37.00
MOBILE HOME SERVICE
$
37.00
TEMPORARY POLE SERVICE
$
37,00
SWIMMING POOLS
$
37.00
SIGN ELECTRIC
$
37.00
C 1Users\sbatle\AppData\LocalWicrosott\W IndoWs\Temporary Internet Flles\Contenl.Oullook\G86E6GQF\MEP APPLICATION 4-11,doc
a
AMOUNT DUE
PLAN SUBMITTAL:
WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING
OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED
PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE
OTHERWISE REQUIRED BY STATE LAW.
OTHER INSPECTIONS AND FEES:
• INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM) ............................... ............... $42.00/HOUR*
• REINSPECTION FEES............................................................................................................. $42.00
• PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED .................................................... . $37.00
• INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR
• ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO
APPROVEDPLANS ............. ............... ................. .... ....... ............ ............................................ $42.00/HOUR
• BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT
SHALL BE 25 % OF THE FEES ESTABLISHED IN THIS TABLE
• FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS —
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE
PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE
WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF
THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF
GRAPEVINE.
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR
LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,
AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST.
Erica Ford Dateally 2021902d1by Erica Frd
912:45,24o06'00'
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT
(OR HOMEOWNER FOR HOMEOWNERS PERMITS)
Erica Ford
PRINTED NAME
PHONE #: 480-226-6769 EMAIL:
`OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER.
—ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS.
Development Services Department, Building Inspections
The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 ale (817) 410.3165
Fax (817) 410-3012 * www.grapevinetexas.gov
C \Users\sbatteWppData\Local\Microsoft\Windows\Temporary Internet Files\Content Outiook\GBOE6GOF\MEP APPLICATION 4-11 doc
received from
Erica Ford
Titan Solar Power TX (ELEC)
525 W Baseline Rd
:Mesa, AZ 85210
Transactions
Fee type
Electrical Miscellaneous Fee
received by
Receipt No.:
Receipt Date:
Receipt Time:
Payment Method:
Project ID #:
Project Type:
Address:
Amount Paid $
Permit Receipt
Receipt No.: 21.00868
21-00868
03/15/2021
4:45 PM
Credit Card
EMISC-21-0890
Electrical Permit - MISC
1064 Lavon Dr.
Amount
$ 37.00
37.00
Account Summary
David Williamson 100-32625-417.000 $ 37.00
Connie Cook
From: Texas Permitting <
Sent: Tuesday, March 30, 2021 8:54 AM
To: Connie Cook
Subject: Project Cancelled
*** EXTERNAL EMAIL COMMUNICATION - PLEASE USE CAUTION BEFORE CLICKING LINKS
AND/OR OPENING ATTACHMENTS ***
Good morning, I just wanted to reach out and let you know the customer has cancelled this project.
Your permit is ready for
1064 Lavon Drive
$150.00
Elec.$37.00
Titan Solar Power TX
Permitting Coordinator
@TITAN
S 0 L A R P 0 W E R
AZ # 284331 1 NM # 393719 1 TX # 32912 1 NV # 84903 1 FL # EC13009924
CA # 1062072 1 CO # EC.0101592 1 NC # U.33714 I SC # 115504
UT # 11674728-5501 1 GA # EN217911 1 MO # 2020006346
P V PLAINVIEW
ENGINEERING
February t9, 2021
Re: Rooftop Solar PV System
1064 Lavon Drive
Grapevine, TX 76051
To Whom It May Concern:
I have reviewed the array layout and structural drawing (sheets PV-3 & PV-5, prepared for Titan Solar Power by Plainview
Engineering LLC, dated 2/9/2021) for the roof -mounted solar PV (photovoltaic) system at the above -referenced address. The
proposed solar array comprises (37) flush -mounted PV panels. The structure to which the PV system will be attached is a
wood -framed, single-family residence with a composition shingle, hip -style roof. The roof framing system generally consists
of 2x6 SYP rafters spaced at 24" OC.
This residence is categorized as a Risk Category II structure under the definitions provided in ASCE 7-10. Wind and snow
design parameters for this project are as follows:
• Basic Wind Speed (MPH, 3 second gust): 115 VultQ�
• Exposure Category: C`,
• Ground Snow Load: 5 PSF `�GGG `�•J'
The proposed solar panels will be affixed to the roof using c >jits�manufactured by Everest Solar Systems. Specifically,
the roof attachments shall be Everest "EverFlash XP Com rs and shall utilize a 5/16" lag bolt with sufficient length to
provide a minimum 2.5" embedment into the rafters. SpaT g between the attachments shall be Everest "CrossRail 48".
Span limit shall be 48" and attachment points shall be staggered such that the attachments are evenly distributed among the
rafters. Maximum Tail cantilever shall be 16". All structural racking components shall be installed and torqued according to
Everest Solar Systems' installation instructions using manufacturer -supplied hardware. Modules shall be top -clamped within
the clamping range specified by the module manufacturer. The total distributed load of the PV array (including panels,
racking, attachments, and wiring) shall not exceed 3 lb/SF.
Solar PV arrays, since they consist of tightly spaced glass panels, effectively prevent coincident application of live loads. I
have analyzed the roof under all code -prescribed load cases while superimposing the dead loads from the solar PV system.
My conclusion is that the roof is capable of resisting the additional loads that will be imparted by the proposed PV system.
The structural design of this proposed solar PV system, as described above, conforms to the 2006 IRC, as adopted by the city
of Grapevine, TX.
Please do not hesitate to contact me should you have any questions about the design of this roof -mounted PV array.
Respectfully,
BennettA Ford, P.E. (TX 9109875)
PLAINVIEW ENGINEERING LLC
TX FIRM# 2MO
Plaimicn 1.ngineeliog 1 I t 2/19/2021
I'avn Itrgi�lered Pngincering firm 1 -'nnFn
Phone: 512.785.4179
i �i 2021