Loading...
HomeMy WebLinkAboutSFRA2021-0889JOB ADDRESS: LOT: 13A DATE OF ISSUANCE: c G t PERMIT #: BUILDING PERMIT APPLICATION 1064 Lavon Dr Grapevine TX76051 BLOCK: 1 SUBDIVISION: Lake Pointe M BUILDING CONTRACTOR (company name): Titan Solar Power TX i CURRENT MAILING ADDRESS: 525 W. Baseline Rd. CITY/STATE/ZIP: Mesa, AZ 85210 PROPERTY OWNER: Randall Jackson CURRENT MAILING ADDRESS: 1064 Lavon Dr CITY/STATE/ZIP: Grapevine/TX/76051 PROJECT VALUE: $ 41514 SUITE # PH:# 480-226-6769 Fax # PHONE NUMBER: (214) 668-3759 FIRESPRINKLERED? YES WHAT TRADES WILL BE NEEDED? rrn ELECTRIC X PLUMBING DESCRIPTION OF WORK TO BE DONE: Installation of12.58kW rooftop solar USE OF BUILDING OR STRUCTURE: Single Family Residence NAME OF BUSINESS: Titan Solar Power TX NO MECHANICAL Total Square Footage under roof- Square Footage of alteration/addition: 661 sq Ft ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for I & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). Erica Ford Digitally signed by Erica Ford PRINT NAME: Erica Ford SIGNATURE Date'2021021912'4214-05`00' PHONE #: 480-226-6769 EMAIL: efordC&titansolarpower.com ❑ PREFERRED TO BE CONTACTED BY E-MAIL Construction Type: t/B Permit Valuation: $ Occupancy Group: 9-'j Fire Sprinkler: YES_ NO Lk - Division: Building Depth: Zoning: Building Width: Occupancy Load: Plan Review Approval Date: 3/16'�:,1 Site Plan Approval: L� tt// Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P 0 BOX 95104, ORAPeVINS, TX 760M (817) 4103165 Setbacks I Approval to Issue Front: Electrical ✓ Left: Plumbing Rear: Mechanical Right: Building Permit Fee: iQ GtiJ Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: j 00 Total Amount Due: ? D et? 0 FORM SPEBMITAPPLICATIO" Issue Date: HAR 15 2021 CITY OF GRAPEVINE c °-r MECHANICAL - ELECTRICAL PLUMBING - IRRIGATION - FUEL GAS PERMIT APPLICATION _ (PLEASE PRINT LEGIBLY - COMPLETE ENTIRE FORT: PERMIT # BLDG. PERMIT # ( DATE: 1211912021 JOB ADDRESS: 1064 Lavon Dr Grapevine, TX 76051 SUITE # DESCRIPTION OF WORK: Installation of 12.58kW rooftop solar, LINE SIDE TAP PROPERTY OWNER: Randall Jackson CONTRACTING COMPANY: Titan Solar Power TX V'r ADDRESS: 1064 Lavon Dr ADDRESS: 525 W. Baseline Rd. CITY/STATE/ZIP: Grapevine, TX 76051 CITY/STATEPLIP. Mesa, AZ 85210 PHONE NUMBER: (214) 668-3759 PHONE NUMBER: 480-226-6769 TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES EACHTRADE I. R-3 1 - 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION & 1,501 - 1,750 $ 76.48 ADDITIONS (PER UNIT) 1,751 - 2,000 $ 83.13 2,001 - 2,250 $ 89.78 TOTAL SQ. FOOT UNDER 2,251 - 3,000 $ 96.43 ROOF 3,001 - 3,500 $ 103.08 3,501 - 4,000 $ 109.73 $ 4,001 + $ 120.37 EACH TRADE II. A, E, I, R-1 1 - 500 $ 37.00 HOTELS, APARTMENTS, 501-100,000 $ 17.50+.035 PER DRINKING/DINING, 100,001-500,000 $ 3,500.00+.03 SQUARE EDUCATIONAL, ASSEMBLY, 500,001 + $15,000.00+.02 FOOT $ INSTITUTIONAL EACH TRADE III. B, F, H, M, S, U OFFICE, RETAIL, WHOLESALE, 1 - 500 $ 37.00 GARAGES, FACTORIES, 501 - 50,000 $ 32.00+.01 PER WORKSHOPS, SERVICE 50,001- 100,000 $ 182.00+.007 SQUARE STATIONS, 100,901+ $ 582.00+.003 FOOT $ _WAREHOUSE CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH -OUTS, SHELL COMPLETIONS, 0- 500 $ 37,00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+.009 50,001- 100,000 $ 127.00+.0( PER $ 100,001-50QOW $ 327.00+A05 DOLLAR 500,001+ $ 1,327A0+.003 VALUATION � EACH TRADE MISCELLANEOUS IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37,00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 C 1Users\sbatle\AppData\LocalWicrosott\W IndoWs\Temporary Internet Flles\Contenl.Oullook\G86E6GQF\MEP APPLICATION 4-11,doc a AMOUNT DUE PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM) ............................... ............... $42.00/HOUR* • REINSPECTION FEES............................................................................................................. $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED .................................................... . $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO APPROVEDPLANS ............. ............... ................. .... ....... ............ ............................................ $42.00/HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25 % OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS — I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. Erica Ford Dateally 2021902d1by Erica Frd 912:45,24o06'00' SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT (OR HOMEOWNER FOR HOMEOWNERS PERMITS) Erica Ford PRINTED NAME PHONE #: 480-226-6769 EMAIL: `OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. —ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. Development Services Department, Building Inspections The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 ale (817) 410.3165 Fax (817) 410-3012 * www.grapevinetexas.gov C \Users\sbatteWppData\Local\Microsoft\Windows\Temporary Internet Files\Content Outiook\GBOE6GOF\MEP APPLICATION 4-11 doc received from Erica Ford Titan Solar Power TX (ELEC) 525 W Baseline Rd :Mesa, AZ 85210 Transactions Fee type Electrical Miscellaneous Fee received by Receipt No.: Receipt Date: Receipt Time: Payment Method: Project ID #: Project Type: Address: Amount Paid $ Permit Receipt Receipt No.: 21.00868 21-00868 03/15/2021 4:45 PM Credit Card EMISC-21-0890 Electrical Permit - MISC 1064 Lavon Dr. Amount $ 37.00 37.00 Account Summary David Williamson 100-32625-417.000 $ 37.00 Connie Cook From: Texas Permitting < Sent: Tuesday, March 30, 2021 8:54 AM To: Connie Cook Subject: Project Cancelled *** EXTERNAL EMAIL COMMUNICATION - PLEASE USE CAUTION BEFORE CLICKING LINKS AND/OR OPENING ATTACHMENTS *** Good morning, I just wanted to reach out and let you know the customer has cancelled this project. Your permit is ready for 1064 Lavon Drive $150.00 Elec.$37.00 Titan Solar Power TX Permitting Coordinator @TITAN S 0 L A R P 0 W E R AZ # 284331 1 NM # 393719 1 TX # 32912 1 NV # 84903 1 FL # EC13009924 CA # 1062072 1 CO # EC.0101592 1 NC # U.33714 I SC # 115504 UT # 11674728-5501 1 GA # EN217911 1 MO # 2020006346 P V PLAINVIEW ENGINEERING February t9, 2021 Re: Rooftop Solar PV System 1064 Lavon Drive Grapevine, TX 76051 To Whom It May Concern: I have reviewed the array layout and structural drawing (sheets PV-3 & PV-5, prepared for Titan Solar Power by Plainview Engineering LLC, dated 2/9/2021) for the roof -mounted solar PV (photovoltaic) system at the above -referenced address. The proposed solar array comprises (37) flush -mounted PV panels. The structure to which the PV system will be attached is a wood -framed, single-family residence with a composition shingle, hip -style roof. The roof framing system generally consists of 2x6 SYP rafters spaced at 24" OC. This residence is categorized as a Risk Category II structure under the definitions provided in ASCE 7-10. Wind and snow design parameters for this project are as follows: • Basic Wind Speed (MPH, 3 second gust): 115 VultQ� • Exposure Category: C`, • Ground Snow Load: 5 PSF `�GGG `�•J' The proposed solar panels will be affixed to the roof using c >jits�manufactured by Everest Solar Systems. Specifically, the roof attachments shall be Everest "EverFlash XP Com rs and shall utilize a 5/16" lag bolt with sufficient length to provide a minimum 2.5" embedment into the rafters. SpaT g between the attachments shall be Everest "CrossRail 48". Span limit shall be 48" and attachment points shall be staggered such that the attachments are evenly distributed among the rafters. Maximum Tail cantilever shall be 16". All structural racking components shall be installed and torqued according to Everest Solar Systems' installation instructions using manufacturer -supplied hardware. Modules shall be top -clamped within the clamping range specified by the module manufacturer. The total distributed load of the PV array (including panels, racking, attachments, and wiring) shall not exceed 3 lb/SF. Solar PV arrays, since they consist of tightly spaced glass panels, effectively prevent coincident application of live loads. I have analyzed the roof under all code -prescribed load cases while superimposing the dead loads from the solar PV system. My conclusion is that the roof is capable of resisting the additional loads that will be imparted by the proposed PV system. The structural design of this proposed solar PV system, as described above, conforms to the 2006 IRC, as adopted by the city of Grapevine, TX. Please do not hesitate to contact me should you have any questions about the design of this roof -mounted PV array. Respectfully, BennettA Ford, P.E. (TX 9109875) PLAINVIEW ENGINEERING LLC TX FIRM# 2MO Plaimicn 1.ngineeliog 1 I t 2/19/2021 I'avn Itrgi�lered Pngincering firm 1 -'nnFn Phone: 512.785.4179 i �i 2021