Loading...
HomeMy WebLinkAboutSFRA2019-2969- FA STANDARD ECO 110 E. Houston St., CONTRACTOR SHALL CALL FOR San Antonio, TX 78205 INSPECTIONS: TX License #:32439 (817) 410-3010 VICINITY MAP 1� f2600 Pool Road SYSTEM INFORMATION CONTRACTOR REGISTRATIC N ARIEL MAP WILL BE REVOKED UPON PERMIT EXPIRATION. SCOPE OF WORK: INTALL (36) ROOF MOUNTED PV SOLAR MODULES, (36) P320 POWER OPTIMIZERS,(1) SOLAREDGE 1000OH-US INVERTER (240V), (1) 60A AC DISCONNECT, AND DERATE MAIN BREAKER TO 175A FROM 200A. IBrittain Residence 2600 Pool Road Grapevine, TX 76051 JUL 19 2019 f a400 ra6l�. ALL CHANGES REQUIRE APPROVAL OF REVISED PLANS APPROVED s, ` n�; w e L BE. KEPT ON JOBSITEATALL nMES MO.` N0 ~1 h 0, 72 MY AM9M P'LANI TO BE KEPI ON TM M SITE AT ALL TVAM DATE: t 1 x BY: BURDM INSPECTION . RELEASE OM NOT APPLY TO N IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED SHEET INDEX. -00- COVER SHEET AND PLOT MAP -1- SITE PLAN DRAWING -2- RACKING PLAN -3- ELECTRICAL NOTES -4- SINGLE LINE DIAGRAM -5 ARRAY MAP SEPARATE PLUMBING, MECHANICAL, -5.1- THREE LINE DIAGRAM EL.ECTRICAL.AND SIGN PERMITS -6- PLACARDS SHALL BE REQUIRED - - REFERENCE PAGE - ATTACHED SPEC. SHEETS / ETC. - -- INVERTER SPECIFICATIONS -- MODULE SPECIFICATIONS GENERAL NOTES 1. ALL CONSTRUCTION / INSTALLATION SHALL COMPLY WITH: 2017 NATIONAL ELECTRIC CODE (NEC) 2012 INTERNATIONAL FIRE CODE (IFC) 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL RESIDENTIAL CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL EXISTING BUILDING CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2. ALL DIMENSIONS WITHIN THESE PLANS ARE APPROXIMATE. 3. ALL CONDUITS ON ROOF SHALL BE A MINIMUM OF 1/2" OFF ROOF. 4. CONSTRUCTION LIMITS: ALL IMPROVEMENTS AND ACCESS SHALL OCCUR WITHIN PLANT PROPERTY LINES. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2O17 NEC 690 & POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER 2017 NEC ARTICLE 705-10, 690-17, 690-64, AND 2012 IFC SECTION 605.11. 6. ALL PV ARRAYS AND ASSOCIATED EQUIPMENT, CONDUIT AND CONDUCTORS SHALL COMPLY WITH SECTION 605.11 OF THE 2012 IFC FOR MARKING DC CONDUCTORS, LOCATION OF DC CONDUCTORS, ROOF ACCESS, PATHWAYS AND SPACING. PLAN SHOULD SHOW COMPLIANCE WITH THE IFC. SYSTEM EQUIPMENT (36x) MISSION SOLAR ENERGY MSE3IOSQ8T (36x) POWER OPTIMIZERS P320 (Ix) SOLAREDGE SE 10000IWNTRACTOR COPY. 11.16 kW DC ISSUE., DRAWN BY: 00 10.00 kW AC 1 06/28/2019 1 ND SITE PLAN TYP ROOF ACCESS POINT Y FIRE ACCESS PATHWAY PROPOSED FLUSH MOUNTED SOLAR MODULES AND POWER OPTIMIZERS UTILITY METER (OUTSIDE WALL) NEW VISIBLE LOCKABLE UTILITY AC DISCONNECT (CAPABLE OF BEING LOCKED IN "OFF" POSITION) IN SCALE: 1" = 50'-0" ELECTRICAL EQUIPMENT DETAIL EXISTING SERVICE PANEL _ (LOCATED INSIDE) D�Ewp,Y \\K ------ ------ - — - --------- EXISTING 200A PANEL WITH A NEW 175A MAIN BREAKER (INSIDE) INVERTER MOUNTED ON OUTSIDE WALL UTILITY METER CONSTRUCTION NOTES O 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. W O 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE 4 N M 00 WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC N WIND SPEED OF 110 MPH (3 SECOND GUST), WIND M EXPOSURE C. 3. THE HOUSE IS A ONE STORY STRUCTURE. O U 4. THE ROOF MEMBERS ARE 2x4 RAFTERS ON 24" W a b CENTERS. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 6" OF NAILING PLATES. O Q po _ 5. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT O OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING Q- ROOF VENTS. r^ 6. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 3 314" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). COMPOSITION SHINGLE 7. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE ROOF STRUCTURE FOLLOWING (CRC R324.7.1, CBC 3111.4.1): - LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. - LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREE LIMBS, WIRES, OR SIGNS VISIBLE LOCKABLE UTILITY AC DISCONNECT (CAPABLE i OF BEING LOCKED IN "OFF" POSITION) NEW Q � I1vV ��_SOLAREDGE INVERTER ° (OUTSIDE WALL) CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: _ 4'Z OF: ES N RELEASE .]DOT AUTHORIZE ANY WORK IN OONFLICT WITH i HE BUILDING CODE OR ZONING OPMNANCE. CITY APPF OVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: Z 2+ 20 BY: BU LDING INSPECTION OMSION: RELEASE DC IES NOT APPLY TO CONSTRUCTION EASEMENTS OR PUBLIC RIGHT -OF --WAY. ALL CHANGES MUST BE APPR[�v , * */ .... . ....... ...... J R. VI Cl i . .12ES i,� 8 7 ...:... t O l !��Oi ZONAL t6-28-2019 A IIRUCTURALONLY cslrucfural �in9ineers Vincise.com TSPC Finn Reg,.treL"n No F.206N o �l U U N ~ N O4 5 O V1 p _ W PLO CIO REVISIONS: DRAWN BY: ND DATE: 06/28/2019 SITE PLAN DRAWING SHEET: 1 ENLARGED P.A RTT 4L ROOF/RACKING PLAN 9 I i 6'-0" 33'-2" , X i • i MISSION SOLAR ENERGY MODULES TYPICAL ATTACHMENT POINT W/ 5/16" S.S. LAG TO BE CENTERED IN STRUCTURAL MEMBER. LAGS MUST HAVE A MINIMUM OF 2.5" THREAD DEPTH INTO STRUCTURAL BEAM N 1800 SCALE: 1/8" = V-0" RA CKING DETAIL IRONRIDGE GROUNDING MIDCLAMP SUPPORT RAIL SPLICE AS REQ. 11'-0" 9'-11" r } -----r I � PV MODULE IRONRIDGE XR100 RAILING L-FOOT TYP. ATTACHMENT POINT "QUICK MOUNT PV" SYST. W/ 5/16" x 6" S.S. LAG. WITH 2 1/2" THREAD EMBEDMENT INTO FRAME MEMBERS Y FIRE ACCESS PATHWAY 2" x 4" RAFTERS CENTERLINE 16'-6" INSTALLATION NOTES O 1. DISTANCE BETWEEN PENETRATIONS NOT TO u EXCEED 6-0" rT� tn w p a, 2. RAIL OVERHANG FROM PENETRATIONS NOT TO 0"o EXCEED 24" m 3. LAG SCREWS SHALL BE AT LEAST 6" FROM ANY o o NAILING PLATES. y n� 4. LAGS MUST HAVE A MINIMUM OF 2.5" THREAD p � DEPTH INTO STRUCTURAL BEAM. 5. ADJUSTMENTS MAY BE REQUIRED DUE TO r EXISTING ROOF CONDITIONS. v 1 6. THE COMBINATION OF MOUNTING SYSTEM AND PV MODULES SHALL MEET THE MINIMUM REQUIREMENTS TO ACHIEVE A CLASS "A" FIRE RATING PER UL 1703 FIRE CLASSIFICATION U o STANDARDS. W N U U 7. PV EQUIPMENT SHALL BE INSTALLED IN a 00 Q N r, ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE ARTICLE 690. CONSTRUCTION MUST ADHERE FOR BOTH Q O INSTALLATION OF ELECTRICAL WIRING AND EQUIPMENT ASSOCIATED WITH THE SOLAR C PHOTOVOLTAIC SYSTEMS. a CITY 9F GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: 5 PtE .r '' r RELEASE DOES N T AUTHORIZE ANY WORK I(* ,3 CONFLICT WITH THE BUILDING CODE ORZ NIN ES R. VI ci 4 CITY APPROVED PLANS TO BE KEPT 1427 THE JOB ITE AT ALL TIMES �� ��ONAI.rr 6-28-2019 DATE: 2I� BY: R CTURAL ONLY BUILDING INSPECTION DIVA ION: RELEASE DOES NOI APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED cSfrucfural �inyineers vincise.com TBPE Firm Regmi,alion No, F-20604 REVISIONS: DRAWN BY: ND DATE: 06/28/2019 RACKING PLAN SHEET: 2 r0 PHOTOVOLTAIC TABLE MAXIMUM SYSTEM VOLTAGE V BRITTAIN RESIDENCE OPERATING VOLTAGE FOR DC PV SOURCE CIRCUITS W o Q, MISSION SOLAR ENERGY MODULE hfSE310SQ8T Zip Cade &05t (PER NEC 690.7 110.3(f3) WITH SUPPLIED MANUFACTURER'S TEMP COEFFICIENTS) 0 N PEAK POWER IP aJc ETC] 310 �gverage High! 96-F f 36-C j RATED VOLTAGEri Irt�p) �3,j7 tZecard LowI -S'F I -22°C 40.12 V MODULE V(iC RATED CURRENT mp ids Exposed Conduit Yes 12 MODULES IN DC LARGEST SERIES p o m OPEN CIRCUIT VOLTAGE (yoc) 40.12 -0 2800 MODULE TEMP COEFFICIENT (V) x o v SHORT CIRCUIT CURRENT i1scl 9J16 Grapevine TX NUMBER OF SOLAR CELLS EO 12 x lap.12(VOC I.11+(-23' - 25-F (sTC1) x -02s r1 OO I = 545.10 VDC {MAXIMUM SYSTEM VOLTAGE)MODULE TEMPERATURE COEFFICIENT iVOQ -0.29W a p PHYSICAL SIZE 65.51h x 39.33W x 1.57d & 40.116s 12 x 33.17(VMP)= 398.04 VDC (OPERATING VOLTAGE) 1�-1 BRITTAIN RESIDENCE DEAD LOAD Module MSE310SQBT CONDUCTORYAMPACITY W PV SOURCE CIRCUITS (DC) N U U 'Weight 40.1 lbs [� o 9.76 MODULE ISC (A). i"i Q N Area (Module) 17.9 sq_ ft. a r/1 15.23 MINIMUM DC AMPACITY (A) 126 OF DESIGN TEMP (INCLUDES ROOF TOP ADJ. FACTOR) Q Quantity Lbs. t Unit Lbs. 1 Qty. 1.12 DESIGN TEMP ADJUSTMENT FACTOR 0 Module 36 40.1 1444 0.80 CONDUIT FILL FACTOR � Power Optimizer 36 1.0 36 Q >0 Midclamp 60 0.1 3 12.20 STRING#SC fA) = 13.62 A x Endclamp 24 0.1 1.4 1 12 (DESIGN TEMP FACTOR) x 0.8 (FILL FACTOR) CIO L-Foot 54 0.2 12 CONDUCTOR AMPACITY Rail 240 0.8 195 AC CIRCUITS Tilt Leg 0 1.5 0 r Splice bars 1 17 1 0.5 9 42 MAX INVERTER OUTPUT (Al (EACH) Footings 54 2.2 121 52.5 MINIMUM AC AMPACITY (A) � 96 OF DESIGN TEMP Total 'WeightIArray 1820 Lbs 1.12 DESIGN TEMP ADJUSTMENT FACTOR v � Total Area ) Array 644 Sq.ft- 0.80 CONDUIT FILL FACTOR Lbs. per SQFT 2.8 Lbsisq.ft. Lbs. per Standoff 33.7 Lbs 42.0 MAX AC OUTPUT (A) (TOTAL) = 46.88 A � U 1.12 DESIGN TEMP FACTOR) x 0.8 (FILL FACTOR) y as CITY OF GRAPEVINE p�G, RELEASED FOR CONSTRUCTION o SHEET: OF: P� .. • �..•'r o RELEASE DOES NOT AUTHORIZE ANY WORK IN *JJ CONRICT WITH THE BUILDING CODE OR ZONING OR ... f..../ N J ES VI CI CITY APPROVED PLANS TO BE KEPT OIL 1 2 ,Sso .: REVISIONS: THE JOB SITE AT ALL TIMES t�ss►ONALG`��~ MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL DATE: -Ai;2 l � BY: �' 06-28-2019 TR CTUR, ONLY BUIL ING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED DRAWN BY: ND DATE: 06/29/2019 WIRING CALCULATIONS SHEET: 3 cSfrucfurai �in9in eers vincise.com TOPE Frtn Rego ho, No F 20604 SINGLE LINE DIAGRAM (6x) #10 AWG & (lx) #8 AWG GROUND (THWN-2/PV WIRE) (SEE NOTE #4) (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) I (12x) MISSION SOLAR ENERGY MSE3IOSQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL INVERTER A SOLAREDGE SE10000H-US (W/ DC DISCONNECT INTEGRATED INTO INVERTER & DC AFCI COMPLIANT TO UL 1699B) 3/4" EMT (3x) #6 AWG & (Ix) #8 AWG GROUN D(THWN-2 WIRE) 60A VISIBLE LOCKABLE UTILITY AC DISCONNECT SWITCH EATON CUTLER HAMMER DG221 URB 240V - NON FUSED - SERVICE ENTRANCE RATED INTEGRATED RGM #8 CU BARE GROUNDING ELECTRODE (RAPID CONDUCTOR (GEC). TO RUN SHUTDOWN) INDEPENDENTLY OF OTHER CONDUCTORS AND TIE DIRECTLY INTO AC GROUNDING ELECTRODE v EXISTING 200A PANEL & METER (PANEL INSIDE AND METER ON OUTSIDE WALL) BI-DIRECTIONAL SINGLE PHASE M UTILITY METER NEW 175A MAIN L BREAKER (DERATED FROM 200A) 60A PV BREAKER (SEE NOTE #1 FOR [� LOCATION) LL GROUNDING ELECTRODE (SEE ELECTRICAL NOTES 98) ELECTRICAL NOTES 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER CURRENT DEVICE. 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1 /2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON REQUEST. 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL). 7. ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 DEGREE CELCIUS PER NEC 110.14(C) & TABLE 310.15 (13)(16) 75 DEGREE COLUMN COPPER. 8. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT 22kAIC OR HIGHER 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. CITY OF GRAPEVINE RiLEASED FOR CONSTRUCTION SHEET: S OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: 5 94ac BY: a' BUILDING INSPECTION DIVISION: RELE ESE DOES NOT APPLY TO CONSTRUCTION IN ASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED U o W � N aIN�raN 00 O " 0 p ,-� W —.4 N O t` w V G� a� V 0 Poo C� *P.4 � o � o a O 0 N REVISIONS: DRAWN BY: ND DATE: 06/28/2019 SINGLE LINE DIAGRAM SHEET: 4 ARRAY DIAGRAM ---+ _ 1+• - -+ - • • +---------- ARRAY 1 (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) + _ — 4- - - + L - — ARRAY 2 (12x) MISSION SOLAR ENERGY MSE3I OSQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) rr ■ •-------------� + = 1 + -+ _ — - ARRAY 3 (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) rr (( • - -■ ----------- MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL ------------�--- - -9- v 19 ---------- 4-------------•-------------- n + (6x) #10 AWG & (lx) #8 AWG GROUND (THHN-2/THWN-2/PV WIRE) (SEE NOTE #4) ELECTRIC AL NOTES 0 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD ' SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM v THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING O d1 N ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER OO CURRENT DEVICE. N O M 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE p O SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. O CCj a 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR -� ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND CI SIZED PER 250.166 REGARDLESS OF VOLTAGE. 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1/2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / > COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL V N HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON W U U REQUEST. 1-I 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, !04 W LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY �y x (NRTL). 7. ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 O O W DEGREE CELCIUS PER NEC It 0. 14(C) & TABLE 310.15 (B)(16) 75 ~ ~ DEGREE COLUMN COPPER. �y a � 8. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT '--i LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. O 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT 22kAIC OR HIGHER 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEF7: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN OONRICT'NffH THE BUILDING CODE OR ZONING ORDINANCE. CITY PPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: XI t ao BY: BUILDING INSPECTION DIVISION: RELEA 5E DOES NOT APPLY TO CONSTRUCTION IN EkSEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED .� •F" .F" 'd cl a$ 0 .F � o � o a 0 0 N REVISIONS: DRAWN BY: ND DATE: 06/28/2019 ARRAY DIAGRAM SHEET: 5 THREE LINE DIAGRAM INVERTER SOLAREDGE SE10000H-US WITH INTEGRATED DC DISCONNECT AND DC COMBINER AFCI COMPLIANT TO UL1699B (INTEGRATED RGM (RAPID SHUTDOWN)) + �� + + DC L2 + + AC N J 3/4" EMT (6x) #10 AWG & (Ix) #8 AWG GROUND (THHN-2/THWN-2/PV WIRE) (SEE NOTE #4) GFPD G a 3/4" EMT (3x) #6 AWG & (Ix) #8 AWG GROUND (THHN-2/THWN-2 WIRE) ---------- G• - - + 60A VISIBLE LOCKABLE UTILITY AC DISCONNECT SWITCH EATON CUTLER HAMMER DG22IURB 240V - NON FUSED - SERVICE ENTRANCE RATED #8 CU BARE GROUNDING ELECTRODE CONDUCTOR (GEC). TO RUN INDEPENDENTLY OF OTHER CONDUCTORS AND TIE DIRECTLY INTO AC GROUNDING ELECTRODE MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL ELECTRICAL NOTES O 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD ' SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM v THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION r T l PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING w Q1 ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER ONO CURRENT DEVICE. N O M 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC v' CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE p O rA SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. N 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF � O a PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC I �� 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND �I �1 SIZED PER 250.166 REGARDLESS OF VOLTAGE. r 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1/2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / r 1 > C) COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL W EXISTING 200A HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON U N METER &PANEL REQUEST Q+ Q N DIRECTIONAL a r SINGLE PHASE 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, Q W UTILITY METER M LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY o 44 � I� ul < (NRTL). P- NEW 175A MAIN - BREAKER 7, ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 O O a - - _ _ , DEGREE CELCIUS PER NEC 110.14(C) & TABLE 310.15 (B)(l6) 75 - - - - - - - �. (DEBATED FROM DEGREE COLUMN COPPER. �y W -, 200A) a 18. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING NEW 60A PV BREAKER ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY 1 - ' (SEE NOTE #1 FOR METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER LOCATION) THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT N _ LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT GROUNDING ELECTRODE 22kAIC OR HIGHER (SEE NOTE 48) V [� 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. 4 �I CITY OF GRAPEVINE 0 FEELEASED FOR CONSTRUCTION r 7 �, o a S ET: OF: �s R SE DOES NOT AUTHORIZE ANY WORK IN o CONRXT WITH THE BUILDING CODE OR ZONING ORDINANCE. N CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES REVISIONS: DATE:. 2 .2f 2-0 BY: BUILDING INSPECTION DIVISION: RELI EASE DOES NOT APPLY TO CONSTRUCTION IN DRAWN BY: ND I EASEMENTS OR PUBLIC RIGHT-OF-WAY. DATE: 06/28/2019 ALI. CHANGES MUST BE APPROVED THREE LINE - DIAGRAM SHEET5.1 THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MAIN SERVICE PANEL, PV SOLAR COMBINER PANELBOARD, AC DISCONNECT) (NEC 690.53, & 690.54) MAX RATED AC OUTPUT OPERATING CURRENT: 42 A OPERATING AC VOLTAGE: 240VAC THIS LABEL TO BE INSTALLED INVERTER (PV POWER SOURCE INFORMATION (NEC 690.53, & 690.54) THIS LABEL TO BE INSTALLED AT PHOTOVOLTAIC INVERTER OR GROUND FAULT INDICATOR (PER NEC 690.5(C)) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED THIS LABEL TO BE INSTALLED AT PV COMBINER PANELBOARD RATED MAX POWER POINT CURRENT: 29.4 ADC WARNING RATED MAX POWER POINT VOLTAGE: 380 VDC PHOTOVOLTAIC SOLAR ONLY. MAX SYSTEM VOLTAGE: 480 VDC NO ADDITIONAL LOADS ALLOWED SHORT CIRCUIT CURRENT: 15 ADC THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MAIN SERVICE PANEL, PV SOLAR COMBINER PANELBOARD) WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MSP, PV SOLAR COMBINER PANELBOARD) ADJACENT TO THE INVERTER BACK -FED BREAKER WARNING INVERTER OUTPUT CONNECTION THIS LABEL TO BE INSTALLED AT THE ENERGIZED DISCONNECTING MEANS. (PER NEC 690.13(B), NEC 690.15, NEC CAUTION: PHOTOVOLTAIC ELECTRIC SYSTEM CONNECTED THIS LABEL TO BE INSTALLED AT THE PV DISCONNECTING MEANS. (PER NEC 690.15, IFC 605.11.1, & IFC 605.11.1.4. PHOTOVOLTAIC AC DISCONNECT THIS LABEL TO BE INSTALLED WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION (PER NEC 690.17(E)) WARNING - ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. THIS LABEL TO BE INSTALLED AT EACH AND EVERY JUNCTION BOX, COMBINER BOX, AC/DC DISCONNECT, AND EVERY DEVICE WHERE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE (PER NEC 690.35(F)) WARNING - ELECTRIC SHOCK HAZARD THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE ENERGIZED WITH RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS THIS LABEL SHALL APPEAR AT EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPERATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS OR FLOORS. SPACING BETWEEN LABELS NOT TO EXCEED 10 FEET (NEC 690.3 1 (G)(3), IFC 605.11.1.2) ►,/:�:i.l ►[e3ii:[�yC�Pl�7N��[�lZ�]� I�:��ili:t� THIS LABEL TO BE INSTALLED AT THE ENERGIZED DISCONNECTING MEANS. (PER NEC 690.15 & NEC 690.53, IFC 605.11.1, & IFC 605.11.1.4) MAIN PV SYSTEM DISCONNECT THIS LABEL TO BE AT THE MAIN ELECTRICAL SERVICE PANEL. (PER NEC 690.56(C)(L)A PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PERMANENT SIGNAGE NOTES 1. ALL LABELS / PLAQUES AND SIGNAGE IS REQUIRED BY THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE AS REQUIRED. PROVIDE ALL WARNING, LABELS AND MARKINGS AS REQUIRED IN THE 2017 NEC. 2. PROVIDE ALL LABELS, CODE REFERENCES AND SPECIFICATIONS IN COMPLIANCE WITH 2O17 NEC ARTICLE 690 NEC SOLAR PHOTOVOLTAIC AND ARTICLE 705 INTERCONNECTED ELECTRIC POWER PRODUCTION SYSTEM. 3. PROVIDE WARNINGS, LABELS, MARKINGS AND THE LOCATION WHERE THEY SHALL BE INSTALLED, AS SPECIFIED IN ARTICLE 690 NEC, 705 FOR SOLAR PHOTOVOLTAIC SYSTEMS. 4. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 2017 NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION 5. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE" PER NEC 705.10 AND 'BREAKERS ARE BACKFED" PER 690-64(B)(5). LABEL MAXIMUM A/C OUTPUT OPERATING CURRENT AND OPERATING VOLTAGE PER NEC 690.54 6. LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH", SWITCH COVER TO BE LOCKED AT ALL TIMES, SWITCH TO BE ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22 7. LABEL "PHOTOVOLTAIC POWER SYSTEM DEDICATED KWH METER" 8. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD -DO NOT TOUCH TERMINALS- TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. 9. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(B) 10. METALLIC CONDUIT SHALL BE USED WITHIN MWOw &E) RE�,�'� $ED JCTMOMBINER PA (IF USED , AD DO NOT AD S TO THIS PANEL SHEE f : F: RELE, kSE DOESFINMAUlt4DRFICATION, OONRJCT V IITH THE "MWGSWDffopVoNWWoRDNVMEG. 'PROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: -2/911= BY: 5;1-?• BUIL61NG INSPECTION DIVISION: RELEA: iE DOES NOT APPLY TO CONSTRUCTION IN E►SEMENTS OR PUBLIC RIGHT-OF-WAY. ALL 01HANGES MUST BE APPROVED V W 7 •--{ �--� hey w � REVISIONS: DRAWN BY: ND DATE: 06/28/2019 PLACARDS SHEET: 6 N_ 00 0 '4 PHOTOVOLTAIC SYSTEM SIE:STANDARD ECO 9 Brittain Residence 10.00 kW AC 110 E. Houston St., 2600 Pool Road Grapevine, TX 76051 11.16 kW DC San Antonio, TX 78205 SINGLE PHASE 120V/240V TX License #:32439 solar=ee SolarEdge Power Optimizer Module Add -On For North America P300 / P320 / P370 / P400 / P405 PV power optimization at the module -level — Up to 25% more energy - Superior efficiency (99.5%) - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization - Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA dge.us solar=@@ SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P370 / P400 / P405 P370 P300 P320 P400 P405 for 60-cell mad- for high -power ( (for (for higher -power 72 & 96-cell {for thin film ules) 60-cell modules) 60 and cell modules) modules) — -_,— le modules) _ — INPUT Rated Input DC Powerl'! ............................ 300 320 _ W Absolute Maximum Input Voltage ..................370..................400........ ........405..... ......... (Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 ...................................... 12.5 - 105 .................. Vdc Maximum Short Circuit Current...I. .............................n't(Is..................-..........I..,.......... 10 11 10:1 ... ........................... Adc..... Maximum DC Input Current ..............I................1................................... 12.5 E 13:75 12:63 Adc Maximum Efficiency 99.5 % Wei hted Eff cienc ......g....--..I ............................ 98.8 % ... Overvoltage Category_ _ _ _ _ _ _ _ _ II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximu.m Output Current 15 A dc . ....... Maximum Output Voltage ........................... .._oltage _ 60 , Vdc_ _85 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) _ Safety Output Voltage per Power _Optimizer �- -- - - - -- -- -- - 1 - - Vdc STANDARD COMPLIANCE EMC -..-.1............................. FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ..-.-.-..-.--.. .............. Safety ...... ....... .......... ............... .................................... ............... ......... IEC62109-1 (class ll safety), UL1741 _RoHS _ _ _ Yes -INSTALLATION SPECIFICATIONS - — — �— — Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128x152x35/ 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128x152'x50/ mm / in Sx5.97x1.37 5x5.97x1.96 Weight (including cables) 630 / 1;4 750 / 1.7 .. .................................................................... 845 / 1.9 gr / Ib MC4 / Input Connector MC4 Compatible Amphenol AH4MC4 Compatible ..... ... .................. I . Double Insulated; Output Wire Type / Connector Double Insulated; MC4 Compatible MC4 / Double Insulated; MC4 Compatible Amphenol AH4 Output Wire Length ......... 0 95 j 3 0 1.2 / 3 9 m/ ft Operatin�TemperatureRanpe _......... -40-+85/ 40-+185 "C/'F Protection .Rating ............. ......... . IP68 / NEMA6P Relative Humidity 0 - 100 % ("Rated STC power of the module. Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING _ SINGLE PHASE A SOLAREDGE INVERTER(21(3) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V HD -WAVE Minimum String Length (Power Optimizers) g 10 18 Maximum String Length (Power Optimizers) 25 25 50 5700 (6000 with Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations ............................................................................................. Yes . 4'1 For detailed string sizing information refer to: http://www.sulareclge.com/sites/default/files/string_sizing_na.pdf ''it is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string solar =@" Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-L SE6000H-US / SE760OH-US / SE10000H- solar m. "wart#'- r� e� WattanW g , 44 ! Optimized installation with HD -Wave technology Specifically designed to work with power optimizers Record -breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small — High reliability without any electrolytic capacitors �,� — Built-in module -level monitoring — Outdoor and indoor installation wave — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) www.solaredge.us solar=@@Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US _ SE3DOOH-US I 0H SE380-US SESOOOH-US --- SE6000H_US SE760OH-US ! SE10000H-US SE1140OH-US OUTPUT - - --- - - - - --- --- Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ...... ._. ,3..... . 08V 5000 �,208V, Max. AC Power Output 3000 3800 @ 240V 5000 6000 @ 2401! 7600 10000 11400 VA 3300. 208y................. . 5000 @, 208V, ............. . ................ AC Output Voltage Min.-Nom: Max. � (183-208 Z29) _ Vac .......................... AC Output Voltage Min.-Nom: Max. . Vac (211.; 240 - 264)........................... 1................�............ . ... AC Frequency (Nominal) ............... 59.3.:60.:60:51'..,........ Hz Maximum Continuous Output Current ..................... 208V..................................... 16 24 A Maximum Continuous Output Current 240V...... 12.5 16 21 ............... 25 ............................ 32 42 ...... 47.5 ........... A GFDI Threshold 1 A Utility�Nloriitoring, Islencl�ing�Proti=ction, .................. CountEyCon K!!rableThresholds-_L____ ___- —_ Yes INPUT Maximum DC Power @240V ........................................................................................... 1 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 ....,.,,..............,.. ............................... 7750 - ........ Transformer -less, Un rounded �.................... Maximum In ut Volta a !?........�................ ....,Yes ................... 480 Vdc Nominal DC Input Voltage ... 380 400 Vdc Maximum Input Current 208V 9 ( 13 5 Maximum Input Current @240V...... ............................ 8:5...........105......1..... .......... ..... 135...... �......165......1...... ZO.. ?? Max. Input Short Circuit Current ............. .............30:5..... 45 Adc Reverse -Polarity Protection .. .. .. .................. Yes Ground -Fault Isolation Detection ..................2.......................................... 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Wei hted Efficiency ....................................................,............. 99 .... .,., 30 Nighttime Power Consumption— W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (o tional), Cellular o tional ......... ............................. P.................. I . P....... ).. Revenue Grade Data, AN51 C12,20 OptionaliZl .......................... Rapid Shutdown - NEC 2014 and 2017 690 12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE - - Safety UL1741, UL1741 SA, UL16998, CSA C22:2: Canadian AFCI according to T.I. L; M .07_ Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) ...................14(H.................................. Emissions _ _ FCC Part_15 Class B ... ......... INSTALLATION SPECIFICATIONS _ _ AC Output Conduit Size / AWG Range 3/4" minimum / 14-6 AWG minimum /14-4 AWG DC Input Conduit Size / # of Strings / 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / AWG,Rang? ............................... AVVG............ Dimensions with Safety Switch (HxWxD) ........ ............14:6 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 % 540 x 370 . . in / mm x 185 .............................. Weight with Safety Switch ............. ................ 22 / 10 25.1 / 11.4 i 26.2 / 11.9 38.8 / 17.61. Ib k Noise .................................. <25 ............................................... <50 dBA Cooling Natural Convection ................................................ Natural convection Operating Temperature Range ..• 13 to +140 / 25 to +60i31 (40`F % :40'C option)I"i,. . F / .. Protection Rating NEMA 3R (Inverter with Safety Switch) Itl For other regional setngs please contact SolarEdge support 1�1 Revenue grade inverter P/N: SExxxxH-US000NK2 iat For power de -rating information refer to: https://www,solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf i4i -40 version P/N: SE—H-US000NN1.14 FM U a:i�.11 CERTIFIED RELIABILITY > Tested to UL1703 & IEC standards > PID Resistant SUPERIOR AESTHETICS > All -black design coupled with outstanding power output > Ideal for residential & commercial applications 13 EXTREME WEATHER RESILIENCE > 5631 Pa snow load (117 psf) tested load to UL1703 > 185 mph wind rating* BAA COMPLIANT FOR GOVERNMENT PROJECTS > Buy American Act )American Recovery & Reinvestment Act I AP LINEAR WARRANTY PRODUCT WARRANTY 300-qlOW 100% 97% Mission Solar Energy Warranty j 90.7% CLASS LEADING POWER OUTPUT 90% o 80.2%! 80% I 18.6 / 70% MAXIMUM EFFICIENCY 1 5 10 15 20 25 YEARS _0,il + 3 940 POSITIVE POWER TOLERANCE High -Power, American Quality Mission Solar Energy is headquartered in San Antonio, TX with module facilities onsite. We produce American quality poducts ensuring the highest power output and reliability to our customers. Our product line is well suited for residential, commercial and utility applications. Every Mission Solar Energy product is certified and surpasses industry standard regulations, proving excellent performance over the long-term. www.missionsolar.com I info@missionsolar.com CERTIFICATIONS IEC 61215/ IEC 61730/ IEC 61701 UL 1703 -�', I:l us PQw�r�uard CEC \_:- LISTED 'As there are different certification requirements in different markets, please contact your local Mission Solar Energy sales representative for the specific certificates applicable to the products in the region in which the products are to be used. `185 mph wind rating based upon installation at 30* or less fixed tilt mount TM MISSION SOLAR 0i ENERGY ■0 11 PERC 60 SPECIFICATIONS .ELECTRICAL Electrical Parameters at Standard Test Conditions (STC) Module Type MSE300SQST MSE305SQBT MSE310SQ8T Power Output Pmax Wp 300 305 310 Module Efficiency % 18.05 18.35 18.65 Tolerance 0-+3% 0-+3% 0-+3% Short -Circuit Current Isc A 9.571 9.664 9.760 Open Circuit Voltage Vac V 40.08 40.10 40.12 Rated Current Imp A 9.058 9.202 9.345 Rated Voltage Vmp V 33.12 33.14 33.17 Fuse Rating 15 20 20 Normal Operating Cell Temperature (NOCT) 46.09*C (±2°C) Temperature Coefficient of Pmax -0.377%/°C Temperature Coefficient of Voc -0.280%/*C Temperature Coefficient of Isc 0.039%/°C Log i.g a11►+ tl� Maximum System Voltage 1,000VDC Operating Temperature Range -40°C (-400F) to +85°C (185*F) Maximum Series Fuse Rating 20A Fire Safety Classification Class C Front &Back Load (UL standard) 5631Pa (117 psf) Tested toUL1703 standard Hail Safety Impact Velocity 25mm at 23 m/s Solar Cells P-type Mono -crystalline Silicon (156.75mm) Cell orientation 60 cells (6x10), 5 busbar Module dimension 1664mm x 999mm x 40mm (65.53 in. x 39.33 in. x 1.58 in.) Weight 18.2 kg (40.1 lb) Front Glass 3.2mm (0.126 in.) tempered, Low -iron, Anti -reflective coating Frame Anodized aluminum alloy Encapsulant Ethylene vinyl acetate (EVA) J-Box Protection class IP67 with 3 bypass -diodes Cables PV wire, 1m (39.37 in.), 4mm2 / 12 AWG Connector MC4 SHIPPING INFORMAT19U. Container FT Pallets Panels 305 W 53' Double stack 36 936 285.48 kW 40' Double stack 28 728 222.04 kW Panels Weight Height Width Length Pallet 26 1,105lbs 45.50" 45.50" 67.00" Mission Solar Energy reserves the right to make specification changes without notice CLASS LEADING 300-31OW IEC 61215/61730/61701 UL UL 1703 listed Snus PoWe.,Guord CEC UmIll MSE305SQ8T: 305WP, 60CELL SOLAR MODULE CURRENT -VOLTAGE CURVE 12 Cells Temp. 10 a N 6 c 0 U a 2 - 0 Incident Irrd•=1,000 2 W/m 305.1 W Incident Irrd.=800 2W/m 2• A W Incident Irrd.=600 2W/m !. 1. W Incident Irrd.=400 zW/m 123 L Incident Irrd.=200 'W/m 5' VY t 0 20 30 20 Voltage [V] Current -voltage characteristics with dependence on irradiance and module temperature BASIC DESIGN (UNITS: mm) - 3�:A z� - irlili )J 11I 1111 1 Front View �e 50 _ I 35.00 I 'F ' --Drain -� Hole �I 297.00 , ! I . 1-� 77.00 832.00 ' f ! Mo- unting Hole I, I ii -)---Y, Grounding Hole eaz oo II' 4- I�, 1 ,000 _�- I Back View 1 MISSION SOLAR ENERGY sue' < Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235 info@missionsolar.com I www.missionsolar.com "A& IRONRIDGE Integrated Grounding System Installation Overview Simplified Grounding Fnr (',rPatPr RnfPty R I rnn/ar (r),zt Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. londing Strap onding Straps are used to )nd rail -to -rail connections. hey are only required on the til with the grounding lug. #' Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type • Attach L-Feet to flashing or standoff. Prepare Rail Connections • Insert splice into first rail, then secure with Bonding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. 0 Mount & Ground Rails • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm A B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Mid Clamp has proven robust in grounding solar modules with a box frame construction, a range of anodization thicknesses and nominal lengths of 78.5' or less. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.com/ig Jilt ngattr. rvwrr.ironrtd WCJA t-aw:227-W3 for more tnfor 1pnwai.... - /-,! � f is, Manual .,'.lt I RON RI DGE Installation Once the end module is set into position, place second module into position, leaving a 1/2" gap between it and the previous module. While holding module in place, drop Grounding Mid Clamps into rail slots and rotate nuts to engage T-bolts. Slide second module flush against clamp tabs. Once clamp teeth are in contact with both module frames and the bolts are properly aligned in slots, torque to 84 in-Ibs (55 in-Ibs for SunPower modules). Repeat procedure for each following module. ► Make sure indent at top of T bolt is perpendicular to rail slot to ensure T bolts are properly seated. ► If grounding mid clamps need to be reinstalled, slightly move the modules so that clamp teeth are in contact with a new section of the module frame. Markings Markings are located on the top surface of the Grounding Mid Clamp and being with the manufacturing and model number followed by the revision and manufacturing date. Manufacturer and model number: IR Revision and manufacturing date: First digit (revision code): A = Rev A, B = Rev B, etc. Second digit (month produced): A = Jan, B = Feb, etc. Third & fourth digits (year produced): 15 = 2015, etc. Ratings Max Overcurrent Protective Device (OCPD) Rating: 25A Installer is responsible for and shall provide an appropriate method of direct -to -earth grounding according to the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. If loose components, loose fasteners or corrosion are found during periodic inspection, replace affected components immediately. Grounding Mid Clamp Leave � 1. Drop in Clamps ap Between Parallel to Rail Modules - „r. 2. Rotate Nuts to Engage Bolts Place Second Module into Position in Rail Slot Torque to 84 in-Ibs (55 in-n-Ibsbs for SunPower modules) - --------_-- T-Bolt Indent Perpendicular to Rail i IR AA01 0 7OPS = ErLtx Module Compatibility The Grounding Mid Clamp may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. AstroEnergy Solar Modules with 35, 40, and 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" can be CH or A; "yy' can be either 10 or "zz" 12; can be blank or (BL). Modules with 40mm frames and model identififer CS6Y-xxxZ; where "Y" can be K, P, V, or X; and ""Z"" can be M, P, PX, or P-SD. Modules with 35, 40, and 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" can be P, L, or M; "ZZ" can be 60 or 72; and Canadian Solar ET Solar "AA" can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" can be either PB or MB. Modules with 40, 45, and 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" can be either 60 or 72; "YY" can be Hanwha Solar PA or PB; and "Z" can be blank or B. Hanwha O CELLS Modules with 32, 35, 40, and 42mm frames and model identifier O.YY-ZZ-xxx; where "YY" can be PLUS, PRO, or PEAK; and "ZZ" can be G3, G4, L-G2, L-G3y, L-G4y, BFR-G3, BLK-G3, BFR-G4, BFR-G4.1, or G4.1/SC. Hyundai Modules with 35 and 50mm frames and model identifier HiS-YxxxZZ; where "Y" can be M or S; and "ZZ" can be MI, MF, MG, SG, Rl, RG, TI, or TG. Modules with 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy' can be M6 or P6; "zz" can be blank, (K), (L), JA Solar (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; and "aa" can be MP, SI, PR, 386, 4BB, 4BB/RE. Jinko Modules with 35 and 40mm frames and model identifier JKMYxxxZZ; where Y' can either be blank or S; and "ZZ" can be M, P, PP, P-B, or P-V. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" can be D or U; "ZZ" can be blank, GX, or SX; and "AA" Kyocera can be LPU, LFU, UPU, LIPS, LPB, ,LFB, LFBS, LF132, LP62, 3AC, 313C, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 5131C, 5FC, 5UC, 6BC, 6FC, or 813C. LG Modules with 35, 40, and 46mm frames and model identifier LGxxxyl z-bb; where "y" can be A, N, or S; "z" can be C or K; and "bb" can be A3, 133, G3, C4 or K4. Mistubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, and 50mm frames. Panasonic Modules with 35mm frames and model identifier VBHNxxxSAyy; where "yy" can be either 06, 068, 11, 11 B, 15, 156, 16 or 1613. Phono Solar REC Solar Renesola SolarWorld Stion SunEdison Suniva Sunpower RECOGNIZED COMPONENT Suntech Trina �i�)Us Winaico Intertek 4008083 Yingli Modules with 35, 40, and 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" can be M or P; "ZZ" can be 20 or 24; and "A" can beF,TorU. Modules with 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" can be M, PE or TP; and "ZZ" can be blank, BLK, SLV, or 72. Modules with 35, 40 and 50mm frames and model identifier JCxxxY-ZZ; where "Y" can be F, M or S; and "ZZ" can be Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Sunmodule Plus, Protect or XL mono or poly modules with 31, 33 or 46mm frames and model identifier SW-xxx. Thin film modules with 35mm frames and model identifier STO-xxx. Modules with 35, 40, and 50mm frames and model identifier SE-YxxxZABCDE; where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be B, C, D, E, H, I, J, K, L, M, or N; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2. Modules with 35, 38, 40, 46, and 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1BO, or 161; and "Z" is blank or B. SPR-A-xx series with standard (G3) or InvisiMount (G5) 46mm frames; where "A" is either E or X; and "xx" is the series number Vd, Vem, Wdb, Woe, and Wd series modules with 35, 40, and 50mm frames. Modules with 35, 40 and 46mm frames and model identifier TSM-xxxYYZZ; where "YY" can be PA05, PC05, PD05, PA14, P014, or PD14; and "ZZ" can be blank or A or A.05 or A.08. Modules with 35 and 40mm frames and model identifier Wsy-xxxz6; where "y" can be either P or T; and ""z"" can be either M or P. Panda, YGE, and YGE-U series modules with 35, 40, and 50 mm frames. �= 0 2015 IronFtidge, Inc- All nghls t**&v@'d. ► on wwwurwwidge.com or call 1-40W 7-9 z I- rnara fMorpn+filon. Vee�Qn t.�7 AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc Address: 1495 Zephyr Ave Hayward, CA 94544 Country: USA Contact: Yann Schwarz Phone: (800) 227-9523 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008083 Authorized by: Manufacturer: Precision Die & Stamping, Inc Address: 1704 W. 10th Street Tempe, AZ 85281 Country: USA Contact: Andy Frola Phone: (480) 967-2038 FAX: (480) 829-0838 Email: andy@precisiondie.com z�l kAVI for Thomas J. Patterson, Certification Manager Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any parry, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: IR XR followed by 4 Alphanumeric Characters ATM for Report 101541132LAX-002 Page 2 of 2 ATM Issued: 28-Jan-2016 ED 16.3.15 (1-Jan-13) Mandatory IRONRIDGE olar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. J11i XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. to XR Rail Family Compatible with Flat & Pitched Roofs Corrosion -Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine -grade A compatible with 52Va range of tilt leg aluminum alloy, then protected with an FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof roof mounting and structural corrosion, while also providing sh-10- attachments. applications. a more attractive appearance. CLASSIFICATION Constructional Data Report (CDR) 11.0 Reference and Address Report Number 101541132LAX-002 Original 22-May-2014 Revised: 15-Jan-2016 Standard(s) UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Applicant IronRidge, Inc Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Contact Yann Schwarz Phone (800) 227-9523 (510)225-0973 FAX (707) 459-1833 Email vschwarzedi iron rid ile.com Manufacturer 2 Precision Die & Stamping, Inc. 1704 W. 10th Street Address Tempe, AZ 85281 Country USA Contact Andy Frola Phone (480) 967-2038 FAX (480) 829-0838 Email andW,:'( recisiondie.com Manufacturer 1 IronRidge, Inc. Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Contact Jim Norsworthy Or Dave Taggart Phone (707) 363-3025 (800) 227-9523 FAX (510) 225-0975 Email inorsworthv( ironridce.com dtaaaart&..ironridae.com Page 1 of 86 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. intertek's responsibility aril liability are limited to the terms and conditions of the agreement. Intertek assures no liability to any party, otter than to the Client in accordance with the agreement. for any loss, expense or damage occasioned by the use of this report. Only the Client is aulhofized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek_ The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Report No. 101541132LAX-002 Page 2 of 86 Issued: 22-May-2014 IronRidge, Inc. Revised: 15-Jan-2016 2.0 Product Description Product XR Rails with Integrated Grounding. Brand name IronRidge Roof Mount The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to extend their length. A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic modules to the system. The End Clamps are not used as a grounding means. The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel serrated T-Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a Description specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection from module to module and module to rail. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T-Bolt, flat washer, split lock washer, and nut, tightened to manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel T-bolt, k-lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models IR XR followed by 4 Alphanumeric Characters Model Similarity N/A Fuse Rating: 20 A Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. Ratings - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. - Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. - Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. ED 16.3 15 (1-Jan-13) Mandatory Report No. 101541132LAX-002 IronRidge, Inc. 2.0 Product Descri Page 3 of 86 Issued: 22-May-2014 Revised: 15-Jan-2016 These systems were evaluated or tested for bonding ana grounamg wain the toliowing PV- Module frames: Motech - Black or Silver Frames Models: IM and XS series, 60 and 72 cell modules with 40 mm frame height. IM and XS series, 60 and 72 cell modules with 45 mm frame height. IM and XS series, 60 and 72 cell modules with 50 mm frame height. Suntech - Black or Silver Frames Models: Wdb, Wde, and Wd series, 60 and 72 cell modules with 35 mm frame height. Vd series, 60 and 72 cell modules with 50 mm frame height. ET Solar - Black or Silver Frames Models: ET Solar 60 cell modules with 35 and 40 mm frames ET-Y660xxxZZ Where "Y" can be P, L, or M; "xxx" refers to the module power rating; "ZZ" can be WB, WW, BB, WBAC, or BBAC ET Solar 72 cell modules with 40 and 50 mm frames ET-Y672xxxZZ Where "Y" can be P, L, or M; "xxx" refers to the module power rating; "ZZ" can be WB, WW, BB, or WBG Hyundai - Black or Silver Frames Models: SG, MG, RG and TG Series, 60 cell modules with 35 mm frame height. MI, RI and TI Series, 72 cell modules with 50 mm frame height. Yingli - Black or Silver Frames Models: Panda and YGE models, 60 cell modules with 40 mm or 35 mm frame height. YGE models, 72 cell modules with 50 mm or 40 mm frame height. Kyocera - Models: KD(xxx)GX-LPU, KD(xxx)GX-LFU, KD135SX-UPU, KD(xxx)GX-LFBS, KD(xxx)GX-LPB KD(xxx)GX-LFB, KD(xxx)GX-LFB2, KD(xxx)GX-LPB2 KD135GX-LPS, KD140GX-LPS, KD140SX-UPU KU(xxx)-3AC, KU(xxx)-4AC, KU(xxx)-5AC, KU(xxx)-3BC, KU(xxx)-4BC KU(xxx)-5BC, KU(xxx)-6BC, KU(xxx)-8BC, KU(xxx)-3FC, KU(xxx)-4FC KU(xxx)-5FC, KU(xxx)-6FC, KU(xxx)-4UC, KU(xxx)-5UC. Where xxx refers to the module power rating Canadian Solar - Black or Silver Frames Models: CS6P-M 60 Cell Modules with a 40mm frame height. CS6P-P 60 Cell Modules with a 40mm frame height. CS6X-M 72 cell modules with a 40mm frame height. CS6X-P 72 cell modules with a 40mm frame height. Report No. 101541132LAX-002 IronRidge, Inc. 2.0 Product Other Ratings Page 4 of 86 Issued: 22-May-2014 Revised: 15-Jan-2016 LG Modules - Black or Silver Frames Models: LG 60 cell modules with 35 mm frames: LGxxxy1z-b3 Where xxx is the module power rating, "y" can be A,N or S, 'Y' can be C or K, and "b" can be A, B, or G. LG 60 cell Modules with 40mm frames: LGxxxy1 z-G4 Where "xxx" is the module power rating, "y' can be N or S, and 'Y' can be C or K LG 72 Cell Modules with 46mm frames: LGxxxy2z-b3 Where "xxx" is the module power rating, "y" can be N or S, 'Y' can be C or K, and "b" can be A, B, or G Suniva Modules - Black or Silver Frames Models: 60 Cell Modules with 35 and 40mm frames: O PTxxx-60-A-YYY-Z M VXxxx-60-A-YYY-Z Where "xxx" is the module power rating, "A" is either 4 or 5, "YYY" is either 100,101,700,1 B0, or 1131, and 'Y' is blank or B. 72 Cell Modules with 38, 46, and 50mm frames: OPTxxx-72-A-YYY-Z MVXxxx-72-A-YYY-Z Where "xxx" is the module power rating, "A" is either 4 or 5, "YYY' is either 100,101,700,1 BO, or 1131, and "Z" is either blank or B Hanwha Modules - Black or Silver Frames Models: HSL72P6-PA-1-xxx(50mm frame) HSL72P6-PB-1-xxx(45mm frame) HSL60P6-PB-1-xxx(40mm frame) HSL60P6-PA-1-xxx(45mm frame) The model number can be followed with a "B" Where xxx is the module power rating Trina Solar Modules - Black or Silver Frames Models: TSM-xxxPA05 (35mm frame height) TSM-xxxPC05 (35mm frame height) TSM-xxx-PD05 (35mm frame height) TSM-xxxPA05 (40mm frame height) TSM-xxxPA14 (46mm frame height) TSM-xxxPD14 (40mm frame height) TSM-xxxPC14 (40mm frame height) The model number can be followed by A and .05 or .08 Where xxx refers to module power rating ED 16.3.15 (I-Jan-13) Mandatory ED 16.3.15 (1-Jan-13) Mandatory Report No. 101541132LAX-002 Page 5 of 86 Issued: 22-May-2014 Report No. 101541132LAX-002 Page 6 of 86 Issued: 22-May-2014 IronRidge, Inc. Revised: 15-Jan-2016 IronRidge, Inc. Revised: 15-Jan-2016 2.0 Product Description 2.0 Product Description SolarWorld Modules - Black or Silver Frames Models: Sunmodule Plus SW-xxx, Sunmodule Protect SW-xxx, Sunmodule XL SW-xxx Mono or Poly with 31, 33, or 46 mm frame height. Where xxx refers to the module power rating Phono Solar Modules - Black or Silver Frames Models: PSxxxP-20/U, PSxxxM-20/U, PSxxxP-24/T, PSxxxM-24/T with 40mm frame height Where xxx refers to module power rating SunEdison modules - Black or Silver Frames Models: SE-QxxxBCC-3Y, SE-MxxxBCC-3Y, SE-FxxxBCC-3Y, SE-PxxxBCC-3Y, SE-QxxxBMC-3Y SE-MxxxBMC-3Y, SE-FxxxBMC-3Y, SE-DxxxBMC-3Y, SE-PxxxBMC-3Y with 50mm frame height. Where xxx refers to module power rating Hanwha Q CELLS modules - Black or Silver Frames Models: Hanwha QCells 60 cell modules with 32 mm frames Q. PL U S-G4-xxx Q.PRO BFR-G4-xxx where xxx refers to module power rating Hanwha QCells 60 cell modules with 35 mm frames: Q.PRO-G3-xxx Q. PRO-BFR-G3-xxx Q.PEAK BLK G3-xxx Q.PLUS G3-xxx where xxx refers to module power rating Hanwha QCells 72 cell modules with 35 mm frames: Q.PRO L-G4y-xxx Q.PLUS L-G4y-xxx where "y" can be blank, 1 or 2 and "xxx" refers to module power rating Hanwha QCell 72 cell modules with 40 mm frames: Q.PRO L-G2xxx Q.PRO L-G3y-xxx where "y" can be blank or 1 and "xxx" refers to module power rating Hanwha QCell 72 cell modules with 42 mm frames: Q.PRO L-G2-xxx where "xxx" refers to module power rating Renesola Modules - Black or Silver Frames Models: Mono and Virtus II Modules: JCxxxM-24/Abh, JCxxxS-24/Abh, JCxxxF-24/Abh, JCxxxM-24/Abh-b, JCxxxS-24/Abh-b JCxxxF-24/Abh-b, JCxxxM-24/Ab, JCxxxM-24/Abv, JCxxxS-24/Ab, JCxxxF-24/Ab JCxxxM-24/Ab-b, JCxxxM-24/Abv-b, JCxxxS-24/Ab-b, JCxxxF-24/Ab-b with 50mm frame height. JCxxxM-24/Bb, JCxxxM-24/Bbv, JCxxxS-24/Bb, JCxxxF-24/Bb, JCxxxM-24/Bb-b JCxxxM-24/Bbv-b, JCxxxS-24/Bb-b, JCxxxF-24/Bb-b, JCxxxM-24/Bbh, JCxxxS-24/Bbh JCxxxF-24/Bbh, JCxxxM-24/Bbh-b, JCxxxS-24/Bbh-b, JCxxxF-24/Bbh-b with 40mm frame height. JCxxxS-24/Db, JCxxxF-24/Db, JCxxxS-24/Db-b, JCxxxF-24/Db-b with 35mm frame height. Where xxx refers to the module power rating. Sunpower Modules- Black or Silver Frames Models: SPR-E-xx series with standard (G3) or InvisiMount (G5) 46 mm frame SPR-X-xx series with standard (G3) or InvisiMount (G5) 46 mm frame. where xx is the series number Panasonic Modules - Black or Sliver Frames Models: VBHNxxxSA06, VBHNxxxSA06B, VBHNxxxSA11, VBHNxxxSA11 B with 35 mm frame height. Where xxx refers to the module power rating Winaico Modules - Black or Silver Frames Models: Winaico 60 Cell modules with 35 and 40 mm frames W sy-xxxz6 Where "y" can be either P or T, "xxx" is the module power rating, and 'Y' can be either M or P Mitsubishi Modules - Black or Silver Frames Models: PV-MYYxxxzz Where YY can be LE or JE, xxx is the module power rating, and ZZ can be either HD, HD2, or FB Jinko Solar Modules - Silver Frames Models: JKMxxxP-60: Where xxx is the module power rating between 250-270 in increments of 5. JKMSxxxP: Where xxx is the module power rating between 255-270 in increments of 5. JKMxxxPP-60: Where xxx is the module power rating between 255-270 in increments of 5. ED 16.3,15 (1-Jan-13) Mandatory ED 16.3.15 (1-Jan-13) Mandatory 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279tek www.inter-com Test Verification of Conformity sm_ Starling Madison Lafquist, Inc, r r. 5224 South 3r Street, Phoenix, Anixona 85040 tel: (602) 438-2500 fox: (602) 438-2505 ROC#E291316 www.smleng.cam IronRidge February 15, 2019 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of 28357 Industrial Boulevard Page 1 of 21 the referenced specifications at the time the tests were carried out. Hayward, CA 94545 iApplicant Name & Address: IronRidge, Inc. 1, Attu: Mr, Carey Geiger, Vice President New Markets 1495 Zephyr Ave. Hayward, CA 94544 Subject: IronRidge XRt(lili Rail, Roof Flush Mounting System — Structural Analysis USA Product Description: XR Rails with Integrated Grounding. Dear Sir: Ratings & Principle Fire Class Resistance Rating: We have analyzed the IronRidge XRHHI Rail for the subject solar module support system and Characteristics: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 determined (bat, for the configurations and criteria dcseribed below, it is in compliance with the and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, applicable sections of the following Reference Documents_ 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. Codes: ASCUSEI 7-10 Min. Design Loads for Buildings &Other Structures International F3ttild.illtg Code 2012 Edition Models: 51-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Brand Name: IronRidge Roof Mount Modules, dated Effective November 1, 2012 by ]CC -ES Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Aluminum Design I%IanuaL 2010 Edition Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, The IronRidge XRl00 Rail is an extruded aluminum section with an overall depth of 2.438 in, and a 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. net area of il.583 sq.in. The rails are used to support solar modules, typically, on the roof of a Verification Issuing Office: Intertek Testing Services NA, Inc. building. See Exhibit 0011— attached_ The modules are clamped to the rails by the IronRidge 8431 Murphy Drive Module 'Mounting Clamps, as shown in the attached Exhibit, The rails are attached to aluminum Middleton, WI 53562 angle brackets that are either attached directly to the roof framing or attached to a stand that is Date of Tests: 08/27/2014 to 03/17/2015 screwed to the roof framing- The rails are mounded across the slope with a small clearance (flush Test Report Number(s): 101769343MID-OOlr1, 101769343MID-001a,101915978MID-001 & 101999492MID-001arl-crl. mounting) to the tuiderlying roof Structure. The installed solar modules are at the Same Slope as the This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically underlying roof structure. imply product certification. Completed by: Chad Naggs Reviewed by: GregoryAllen All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of Title: Technician II, Fire Resistance Title: Engineering Team Lead, Fire Resistance the rails. The maximum span of the rails is governed by either the mid -span flexural strmes or the deflection requirement that the rail not come into contact with the roof. Signature: Signature:] Date: 03/30/2015 Date: 03/30/2015 The effect of seismic loads (for all design categories A-F) have been determined to be less than the efTect due to wind leads in all load conditions and combinations, Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables 1 A-9A are for modules with a 'cables maximum lung distension of 67.5 inches and I B-9B are for modules with a maximum tang — _ - dimension of 78.5 inches. This Verification is for the exclusive use of lntertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client m accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its Starling Nladison Lofquist, Inc. Consulting Structural and Forensic Engineers marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results Texas Firm Registration #F-16420 referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under on Intertek certification program. GFT-OP-13a (24-MAR-2014) ' r IronRidge Mr, Carey Geiger IronRidge YR100 Rail, Roof 1=htsh Mounting System — Stnlctural Analysis Modulo Glass fCe'lls Frorne Coirnpsiitiiity, X - I.2. 2.2 myrt 'f=15.40mm i' -x February 15, 200 Page 21 of 21 Figure 8: CAN-10 [`.lamp Module Frame f)imcnsional Requirements Our analysis assumes that the rail;, including the connections and associated hardware., am installed in a workmanlike manner in accordance v6th the IrorlRidge Flush Mount Trt.Stallation Manual" by lronRldge and gcncrally accepted standarrls of construction practice. Additional information is a vailable It the IronRidge web site:, IronRidge,conl. 4ferjlication of PV Module capacity to support the loads associated with the given array shall be lihe responsibility of the Contractor of Owner and not lronitiJgc or Starling Madison Lofquist. The adequacy of the supporting, roof framing is to be determined by others. Please feel line to Contact tile at your convenience if you have any questions,, Respectfully yours, Tres Warner, P,tr, • '•.*� Design Division Manager h................. TREE J. WARNER Digitally signicd tsyTrt;3 I Warner Trey DN: c-US omStarling Madison Lofqulst Inc, 0 u=A014z73w00153 B F918), Cn rrn -Tres JNarner Date. 2w 9.02.- 9 1429:07-47'O6' Starling Madison Lofquisy Inc, Cc►r,sulting SuUCLUtal and Forensic Engitrcers Texas Firm Registrsttion 4117-16420 AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc 1495 Zephyr Ave Address: Hayward, CA 94544 Country: USA Contact: Yann Schwarz Phone: (800)227-9523 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008377 Authorized by: Manufacturer: IronRidge, Inc Address: 1495 Zephyr Ave Hayward, CA 94544 Country: USA Contact: Jim Norsworthy Or Phone: (707)363-3025 FAX: (510)225-0975 Email: jorsworthy@ironridge.com IT for Thomas J. Patterson, Certification Manager Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number This Authorization to Mark is for the exclusive use of Intertek's Client and Is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement. for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Fallow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: IR XR followed by 4 Alphanumeric Characters ATM for Report 101541132LAX-002 Page 1 of 2 ATM Issued: 28-Jan-2016 ED 16.3.15 (1-Jan-13) Mandatory June 20, 2014 Mr. Meir Adest SolarEdge Technologies Ltd 6 Ha'Harash St. HOD HASHARON, ISRAEL 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G 10 1703554 Ph: +972.9.957.6620 email: meir.a@solaredge.com Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: 0 Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 • 1-ph Inverters: o SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Pagel of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. FJ f Wi Appiwed Intertek Intertek intertek Irztei tek Intertek Intertek Intertek Testing Services NA, Inc. SD 12.12 (11/11110) Informative SolarEdge Technologies Ltd • 3-ph Inverters: Letter Report 101703554CRT-001 June 201h, 2014 o SE9KUS / SEIOKUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Signature: Engineering Team Lead -�----- 7^ Title: Signature StaffEngineer Date June 20m, 2014 Date: June 20` , 2014 Intertek Testing Services NA, Inc. Page 2 of 2 So 12.1.2 (11/11/10) Informative - FA STANDARD ECO 110 E. Houston St., CONTRACTOR SHALL CALL FOR San Antonio, TX 78205 INSPECTIONS: TX License #:32439 (817) 410-3010 VICINITY MAP 1� f2600 Pool Road SYSTEM INFORMATION CONTRACTOR REGISTRATIC N ARIEL MAP WILL BE REVOKED UPON PERMIT EXPIRATION. SCOPE OF WORK: INTALL (36) ROOF MOUNTED PV SOLAR MODULES, (36) P320 POWER OPTIMIZERS,(1) SOLAREDGE 1000OH-US INVERTER (240V), (1) 60A AC DISCONNECT, AND DERATE MAIN BREAKER TO 175A FROM 200A. IBrittain Residence 2600 Pool Road Grapevine, TX 76051 JUL 19 2019 f a400 ra6l�. ALL CHANGES REQUIRE APPROVAL OF REVISED PLANS APPROVED s, ` n�; w e L BE. KEPT ON JOBSITEATALL nMES MO.` N0 ~1 h 0, 72 MY AM9M P'LANI TO BE KEPI ON TM M SITE AT ALL TVAM DATE: t 1 x BY: BURDM INSPECTION . RELEASE OM NOT APPLY TO N IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED SHEET INDEX. -00- COVER SHEET AND PLOT MAP -1- SITE PLAN DRAWING -2- RACKING PLAN -3- ELECTRICAL NOTES -4- SINGLE LINE DIAGRAM -5 ARRAY MAP SEPARATE PLUMBING, MECHANICAL, -5.1- THREE LINE DIAGRAM EL.ECTRICAL.AND SIGN PERMITS -6- PLACARDS SHALL BE REQUIRED - - REFERENCE PAGE - ATTACHED SPEC. SHEETS / ETC. - -- INVERTER SPECIFICATIONS -- MODULE SPECIFICATIONS GENERAL NOTES 1. ALL CONSTRUCTION / INSTALLATION SHALL COMPLY WITH: 2017 NATIONAL ELECTRIC CODE (NEC) 2012 INTERNATIONAL FIRE CODE (IFC) 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL RESIDENTIAL CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL EXISTING BUILDING CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2. ALL DIMENSIONS WITHIN THESE PLANS ARE APPROXIMATE. 3. ALL CONDUITS ON ROOF SHALL BE A MINIMUM OF 1/2" OFF ROOF. 4. CONSTRUCTION LIMITS: ALL IMPROVEMENTS AND ACCESS SHALL OCCUR WITHIN PLANT PROPERTY LINES. 5. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2O17 NEC 690 & POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER 2017 NEC ARTICLE 705-10, 690-17, 690-64, AND 2012 IFC SECTION 605.11. 6. ALL PV ARRAYS AND ASSOCIATED EQUIPMENT, CONDUIT AND CONDUCTORS SHALL COMPLY WITH SECTION 605.11 OF THE 2012 IFC FOR MARKING DC CONDUCTORS, LOCATION OF DC CONDUCTORS, ROOF ACCESS, PATHWAYS AND SPACING. PLAN SHOULD SHOW COMPLIANCE WITH THE IFC. SYSTEM EQUIPMENT (36x) MISSION SOLAR ENERGY MSE3IOSQ8T (36x) POWER OPTIMIZERS P320 (Ix) SOLAREDGE SE 10000IWNTRACTOR COPY. 11.16 kW DC ISSUE., DRAWN BY: 00 10.00 kW AC 1 06/28/2019 1 ND SITE PLAN TYP ROOF ACCESS POINT Y FIRE ACCESS PATHWAY PROPOSED FLUSH MOUNTED SOLAR MODULES AND POWER OPTIMIZERS UTILITY METER (OUTSIDE WALL) NEW VISIBLE LOCKABLE UTILITY AC DISCONNECT (CAPABLE OF BEING LOCKED IN "OFF" POSITION) IN SCALE: 1" = 50'-0" ELECTRICAL EQUIPMENT DETAIL EXISTING SERVICE PANEL _ (LOCATED INSIDE) D�Ewp,Y \\K ------ ------ - — - --------- EXISTING 200A PANEL WITH A NEW 175A MAIN BREAKER (INSIDE) INVERTER MOUNTED ON OUTSIDE WALL UTILITY METER CONSTRUCTION NOTES O 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. W O 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE 4 N M 00 WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC N WIND SPEED OF 110 MPH (3 SECOND GUST), WIND M EXPOSURE C. 3. THE HOUSE IS A ONE STORY STRUCTURE. O U 4. THE ROOF MEMBERS ARE 2x4 RAFTERS ON 24" W a b CENTERS. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 6" OF NAILING PLATES. O Q po _ 5. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT O OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING Q- ROOF VENTS. r^ 6. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 3 314" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). COMPOSITION SHINGLE 7. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE ROOF STRUCTURE FOLLOWING (CRC R324.7.1, CBC 3111.4.1): - LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. - LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREE LIMBS, WIRES, OR SIGNS VISIBLE LOCKABLE UTILITY AC DISCONNECT (CAPABLE i OF BEING LOCKED IN "OFF" POSITION) NEW Q � I1vV ��_SOLAREDGE INVERTER ° (OUTSIDE WALL) CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: _ 4'Z OF: ES N RELEASE .]DOT AUTHORIZE ANY WORK IN OONFLICT WITH i HE BUILDING CODE OR ZONING OPMNANCE. CITY APPF OVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: Z 2+ 20 BY: BU LDING INSPECTION OMSION: RELEASE DC IES NOT APPLY TO CONSTRUCTION EASEMENTS OR PUBLIC RIGHT -OF --WAY. ALL CHANGES MUST BE APPR[�v , * */ .... . ....... ...... J R. VI Cl i . .12ES i,� 8 7 ...:... t O l !��Oi ZONAL t6-28-2019 A IIRUCTURALONLY cslrucfural �in9ineers Vincise.com TSPC Finn Reg,.treL"n No F.206N o �l U U N ~ N O4 5 O V1 p _ W PLO CIO REVISIONS: DRAWN BY: ND DATE: 06/28/2019 SITE PLAN DRAWING SHEET: 1 ENLARGED P.A RTT 4L ROOF/RACKING PLAN 9 I i 6'-0" 33'-2" , X i • i MISSION SOLAR ENERGY MODULES TYPICAL ATTACHMENT POINT W/ 5/16" S.S. LAG TO BE CENTERED IN STRUCTURAL MEMBER. LAGS MUST HAVE A MINIMUM OF 2.5" THREAD DEPTH INTO STRUCTURAL BEAM N 1800 SCALE: 1/8" = V-0" RA CKING DETAIL IRONRIDGE GROUNDING MIDCLAMP SUPPORT RAIL SPLICE AS REQ. 11'-0" 9'-11" r } -----r I � PV MODULE IRONRIDGE XR100 RAILING L-FOOT TYP. ATTACHMENT POINT "QUICK MOUNT PV" SYST. W/ 5/16" x 6" S.S. LAG. WITH 2 1/2" THREAD EMBEDMENT INTO FRAME MEMBERS Y FIRE ACCESS PATHWAY 2" x 4" RAFTERS CENTERLINE 16'-6" INSTALLATION NOTES O 1. DISTANCE BETWEEN PENETRATIONS NOT TO u EXCEED 6-0" rT� tn w p a, 2. RAIL OVERHANG FROM PENETRATIONS NOT TO 0"o EXCEED 24" m 3. LAG SCREWS SHALL BE AT LEAST 6" FROM ANY o o NAILING PLATES. y n� 4. LAGS MUST HAVE A MINIMUM OF 2.5" THREAD p � DEPTH INTO STRUCTURAL BEAM. 5. ADJUSTMENTS MAY BE REQUIRED DUE TO r EXISTING ROOF CONDITIONS. v 1 6. THE COMBINATION OF MOUNTING SYSTEM AND PV MODULES SHALL MEET THE MINIMUM REQUIREMENTS TO ACHIEVE A CLASS "A" FIRE RATING PER UL 1703 FIRE CLASSIFICATION U o STANDARDS. W N U U 7. PV EQUIPMENT SHALL BE INSTALLED IN a 00 Q N r, ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE ARTICLE 690. CONSTRUCTION MUST ADHERE FOR BOTH Q O INSTALLATION OF ELECTRICAL WIRING AND EQUIPMENT ASSOCIATED WITH THE SOLAR C PHOTOVOLTAIC SYSTEMS. a CITY 9F GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: 5 PtE .r '' r RELEASE DOES N T AUTHORIZE ANY WORK I(* ,3 CONFLICT WITH THE BUILDING CODE ORZ NIN ES R. VI ci 4 CITY APPROVED PLANS TO BE KEPT 1427 THE JOB ITE AT ALL TIMES �� ��ONAI.rr 6-28-2019 DATE: 2I� BY: R CTURAL ONLY BUILDING INSPECTION DIVA ION: RELEASE DOES NOI APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED cSfrucfural �inyineers vincise.com TBPE Firm Regmi,alion No, F-20604 REVISIONS: DRAWN BY: ND DATE: 06/28/2019 RACKING PLAN SHEET: 2 r0 PHOTOVOLTAIC TABLE MAXIMUM SYSTEM VOLTAGE V BRITTAIN RESIDENCE OPERATING VOLTAGE FOR DC PV SOURCE CIRCUITS W o Q, MISSION SOLAR ENERGY MODULE hfSE310SQ8T Zip Cade &05t (PER NEC 690.7 110.3(f3) WITH SUPPLIED MANUFACTURER'S TEMP COEFFICIENTS) 0 N PEAK POWER IP aJc ETC] 310 �gverage High! 96-F f 36-C j RATED VOLTAGEri Irt�p) �3,j7 tZecard LowI -S'F I -22°C 40.12 V MODULE V(iC RATED CURRENT mp ids Exposed Conduit Yes 12 MODULES IN DC LARGEST SERIES p o m OPEN CIRCUIT VOLTAGE (yoc) 40.12 -0 2800 MODULE TEMP COEFFICIENT (V) x o v SHORT CIRCUIT CURRENT i1scl 9J16 Grapevine TX NUMBER OF SOLAR CELLS EO 12 x lap.12(VOC I.11+(-23' - 25-F (sTC1) x -02s r1 OO I = 545.10 VDC {MAXIMUM SYSTEM VOLTAGE)MODULE TEMPERATURE COEFFICIENT iVOQ -0.29W a p PHYSICAL SIZE 65.51h x 39.33W x 1.57d & 40.116s 12 x 33.17(VMP)= 398.04 VDC (OPERATING VOLTAGE) 1�-1 BRITTAIN RESIDENCE DEAD LOAD Module MSE310SQBT CONDUCTORYAMPACITY W PV SOURCE CIRCUITS (DC) N U U 'Weight 40.1 lbs [� o 9.76 MODULE ISC (A). i"i Q N Area (Module) 17.9 sq_ ft. a r/1 15.23 MINIMUM DC AMPACITY (A) 126 OF DESIGN TEMP (INCLUDES ROOF TOP ADJ. FACTOR) Q Quantity Lbs. t Unit Lbs. 1 Qty. 1.12 DESIGN TEMP ADJUSTMENT FACTOR 0 Module 36 40.1 1444 0.80 CONDUIT FILL FACTOR � Power Optimizer 36 1.0 36 Q >0 Midclamp 60 0.1 3 12.20 STRING#SC fA) = 13.62 A x Endclamp 24 0.1 1.4 1 12 (DESIGN TEMP FACTOR) x 0.8 (FILL FACTOR) CIO L-Foot 54 0.2 12 CONDUCTOR AMPACITY Rail 240 0.8 195 AC CIRCUITS Tilt Leg 0 1.5 0 r Splice bars 1 17 1 0.5 9 42 MAX INVERTER OUTPUT (Al (EACH) Footings 54 2.2 121 52.5 MINIMUM AC AMPACITY (A) � 96 OF DESIGN TEMP Total 'WeightIArray 1820 Lbs 1.12 DESIGN TEMP ADJUSTMENT FACTOR v � Total Area ) Array 644 Sq.ft- 0.80 CONDUIT FILL FACTOR Lbs. per SQFT 2.8 Lbsisq.ft. Lbs. per Standoff 33.7 Lbs 42.0 MAX AC OUTPUT (A) (TOTAL) = 46.88 A � U 1.12 DESIGN TEMP FACTOR) x 0.8 (FILL FACTOR) y as CITY OF GRAPEVINE p�G, RELEASED FOR CONSTRUCTION o SHEET: OF: P� .. • �..•'r o RELEASE DOES NOT AUTHORIZE ANY WORK IN *JJ CONRICT WITH THE BUILDING CODE OR ZONING OR ... f..../ N J ES VI CI CITY APPROVED PLANS TO BE KEPT OIL 1 2 ,Sso .: REVISIONS: THE JOB SITE AT ALL TIMES t�ss►ONALG`��~ MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL DATE: -Ai;2 l � BY: �' 06-28-2019 TR CTUR, ONLY BUIL ING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED DRAWN BY: ND DATE: 06/29/2019 WIRING CALCULATIONS SHEET: 3 cSfrucfurai �in9in eers vincise.com TOPE Frtn Rego ho, No F 20604 SINGLE LINE DIAGRAM (6x) #10 AWG & (lx) #8 AWG GROUND (THWN-2/PV WIRE) (SEE NOTE #4) (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) I (12x) MISSION SOLAR ENERGY MSE3IOSQ8T WITH (12x) P320 POWER OPTIMIERS (FOR GROUNDING SEE NOTE #5) MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL INVERTER A SOLAREDGE SE10000H-US (W/ DC DISCONNECT INTEGRATED INTO INVERTER & DC AFCI COMPLIANT TO UL 1699B) 3/4" EMT (3x) #6 AWG & (Ix) #8 AWG GROUN D(THWN-2 WIRE) 60A VISIBLE LOCKABLE UTILITY AC DISCONNECT SWITCH EATON CUTLER HAMMER DG221 URB 240V - NON FUSED - SERVICE ENTRANCE RATED INTEGRATED RGM #8 CU BARE GROUNDING ELECTRODE (RAPID CONDUCTOR (GEC). TO RUN SHUTDOWN) INDEPENDENTLY OF OTHER CONDUCTORS AND TIE DIRECTLY INTO AC GROUNDING ELECTRODE v EXISTING 200A PANEL & METER (PANEL INSIDE AND METER ON OUTSIDE WALL) BI-DIRECTIONAL SINGLE PHASE M UTILITY METER NEW 175A MAIN L BREAKER (DERATED FROM 200A) 60A PV BREAKER (SEE NOTE #1 FOR [� LOCATION) LL GROUNDING ELECTRODE (SEE ELECTRICAL NOTES 98) ELECTRICAL NOTES 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER CURRENT DEVICE. 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1 /2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON REQUEST. 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL). 7. ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 DEGREE CELCIUS PER NEC 110.14(C) & TABLE 310.15 (13)(16) 75 DEGREE COLUMN COPPER. 8. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT 22kAIC OR HIGHER 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. CITY OF GRAPEVINE RiLEASED FOR CONSTRUCTION SHEET: S OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: 5 94ac BY: a' BUILDING INSPECTION DIVISION: RELE ESE DOES NOT APPLY TO CONSTRUCTION IN ASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED U o W � N aIN�raN 00 O " 0 p ,-� W —.4 N O t` w V G� a� V 0 Poo C� *P.4 � o � o a O 0 N REVISIONS: DRAWN BY: ND DATE: 06/28/2019 SINGLE LINE DIAGRAM SHEET: 4 ARRAY DIAGRAM ---+ _ 1+• - -+ - • • +---------- ARRAY 1 (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) + _ — 4- - - + L - — ARRAY 2 (12x) MISSION SOLAR ENERGY MSE3I OSQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) rr ■ •-------------� + = 1 + -+ _ — - ARRAY 3 (12x) MISSION SOLAR ENERGY MSE310SQ8T WITH (12x) P320 POWER OPTIMIZERS (FOR GROUNDING SEE NOTE #5) rr (( • - -■ ----------- MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL ------------�--- - -9- v 19 ---------- 4-------------•-------------- n + (6x) #10 AWG & (lx) #8 AWG GROUND (THHN-2/THWN-2/PV WIRE) (SEE NOTE #4) ELECTRIC AL NOTES 0 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD ' SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM v THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING O d1 N ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER OO CURRENT DEVICE. N O M 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE p O SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. O CCj a 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR -� ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND CI SIZED PER 250.166 REGARDLESS OF VOLTAGE. 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1/2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / > COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL V N HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON W U U REQUEST. 1-I 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, !04 W LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY �y x (NRTL). 7. ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 O O W DEGREE CELCIUS PER NEC It 0. 14(C) & TABLE 310.15 (B)(16) 75 ~ ~ DEGREE COLUMN COPPER. �y a � 8. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT '--i LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. O 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT 22kAIC OR HIGHER 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEF7: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN OONRICT'NffH THE BUILDING CODE OR ZONING ORDINANCE. CITY PPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: XI t ao BY: BUILDING INSPECTION DIVISION: RELEA 5E DOES NOT APPLY TO CONSTRUCTION IN EkSEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED .� •F" .F" 'd cl a$ 0 .F � o � o a 0 0 N REVISIONS: DRAWN BY: ND DATE: 06/28/2019 ARRAY DIAGRAM SHEET: 5 THREE LINE DIAGRAM INVERTER SOLAREDGE SE10000H-US WITH INTEGRATED DC DISCONNECT AND DC COMBINER AFCI COMPLIANT TO UL1699B (INTEGRATED RGM (RAPID SHUTDOWN)) + �� + + DC L2 + + AC N J 3/4" EMT (6x) #10 AWG & (Ix) #8 AWG GROUND (THHN-2/THWN-2/PV WIRE) (SEE NOTE #4) GFPD G a 3/4" EMT (3x) #6 AWG & (Ix) #8 AWG GROUND (THHN-2/THWN-2 WIRE) ---------- G• - - + 60A VISIBLE LOCKABLE UTILITY AC DISCONNECT SWITCH EATON CUTLER HAMMER DG22IURB 240V - NON FUSED - SERVICE ENTRANCE RATED #8 CU BARE GROUNDING ELECTRODE CONDUCTOR (GEC). TO RUN INDEPENDENTLY OF OTHER CONDUCTORS AND TIE DIRECTLY INTO AC GROUNDING ELECTRODE MAX AVAILABLE BACKFEED FOR SES BUS SIZE: 200A BUS x 1.2 = 240A - 175A BREAKER = 65A BACKFEED AVAILABLE MAX BACKFED CURRENT FOR OCPD: 42A x 1.25 = 52.5A TOTAL ELECTRICAL NOTES O 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD ' SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM v THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION r T l PER NEC ART. 705.12(D)(7) WHEN USING THE 120% OF RATING w Q1 ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER ONO CURRENT DEVICE. N O M 2. IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC v' CIRCUITS SHALL COMPLY WITH NEC 690.4(B) AND SHALL BE p O rA SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. N 3. EXPOSED NON -CURRENT CARRYING METAL PARTS OF � O a PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC I �� 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A) AND �I �1 SIZED PER 250.166 REGARDLESS OF VOLTAGE. r 4. ALL CONDUIT ON ROOF NEEDS TO BE PLACED 1/2"-3 1/2" OFF THE ROOF'S SURFACE. 5. EACH MODULE (AND MICRO -INVERTER, IF APPLICABLE) SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE BONDING MIDCLAMP / r 1 > C) COMPONENTS, AND AT EACH ROW UTILIZING AMPHENOL W EXISTING 200A HELIO LUGS (UL 2703). SPEC SHEETS CAN BE PROVIDED UPON U N METER &PANEL REQUEST Q+ Q N DIRECTIONAL a r SINGLE PHASE 6. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, Q W UTILITY METER M LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY o 44 � I� ul < (NRTL). P- NEW 175A MAIN - BREAKER 7, ALL TERMINATIONS OF EQUIPMENT TO BE A MINIMUM 75 O O a - - _ _ , DEGREE CELCIUS PER NEC 110.14(C) & TABLE 310.15 (B)(l6) 75 - - - - - - - �. (DEBATED FROM DEGREE COLUMN COPPER. �y W -, 200A) a 18. FOR SERVICE UPGRADES, IF THE EXISTING GROUNDING NEW 60A PV BREAKER ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY 1 - ' (SEE NOTE #1 FOR METALLIC WATER PIPING, OR IT HAS A RESISTANCE GREATER LOCATION) THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT N _ LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. 9. ALL BREAKERS AND SERVICE EQUIPMENT ARE RATED AT GROUNDING ELECTRODE 22kAIC OR HIGHER (SEE NOTE 48) V [� 10. GROUND BUSHINGS TO BE USED ON ALL METALLIC RACEWAYS. 4 �I CITY OF GRAPEVINE 0 FEELEASED FOR CONSTRUCTION r 7 �, o a S ET: OF: �s R SE DOES NOT AUTHORIZE ANY WORK IN o CONRXT WITH THE BUILDING CODE OR ZONING ORDINANCE. N CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES REVISIONS: DATE:. 2 .2f 2-0 BY: BUILDING INSPECTION DIVISION: RELI EASE DOES NOT APPLY TO CONSTRUCTION IN DRAWN BY: ND I EASEMENTS OR PUBLIC RIGHT-OF-WAY. DATE: 06/28/2019 ALI. CHANGES MUST BE APPROVED THREE LINE - DIAGRAM SHEET5.1 THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MAIN SERVICE PANEL, PV SOLAR COMBINER PANELBOARD, AC DISCONNECT) (NEC 690.53, & 690.54) MAX RATED AC OUTPUT OPERATING CURRENT: 42 A OPERATING AC VOLTAGE: 240VAC THIS LABEL TO BE INSTALLED INVERTER (PV POWER SOURCE INFORMATION (NEC 690.53, & 690.54) THIS LABEL TO BE INSTALLED AT PHOTOVOLTAIC INVERTER OR GROUND FAULT INDICATOR (PER NEC 690.5(C)) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED THIS LABEL TO BE INSTALLED AT PV COMBINER PANELBOARD RATED MAX POWER POINT CURRENT: 29.4 ADC WARNING RATED MAX POWER POINT VOLTAGE: 380 VDC PHOTOVOLTAIC SOLAR ONLY. MAX SYSTEM VOLTAGE: 480 VDC NO ADDITIONAL LOADS ALLOWED SHORT CIRCUIT CURRENT: 15 ADC THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MAIN SERVICE PANEL, PV SOLAR COMBINER PANELBOARD) WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR THIS LABEL TO BE INSTALLED AT DISTRIBUTION EQUIPMENT (MSP, PV SOLAR COMBINER PANELBOARD) ADJACENT TO THE INVERTER BACK -FED BREAKER WARNING INVERTER OUTPUT CONNECTION THIS LABEL TO BE INSTALLED AT THE ENERGIZED DISCONNECTING MEANS. (PER NEC 690.13(B), NEC 690.15, NEC CAUTION: PHOTOVOLTAIC ELECTRIC SYSTEM CONNECTED THIS LABEL TO BE INSTALLED AT THE PV DISCONNECTING MEANS. (PER NEC 690.15, IFC 605.11.1, & IFC 605.11.1.4. PHOTOVOLTAIC AC DISCONNECT THIS LABEL TO BE INSTALLED WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION (PER NEC 690.17(E)) WARNING - ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. THIS LABEL TO BE INSTALLED AT EACH AND EVERY JUNCTION BOX, COMBINER BOX, AC/DC DISCONNECT, AND EVERY DEVICE WHERE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE (PER NEC 690.35(F)) WARNING - ELECTRIC SHOCK HAZARD THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE ENERGIZED WITH RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS THIS LABEL SHALL APPEAR AT EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPERATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS OR FLOORS. SPACING BETWEEN LABELS NOT TO EXCEED 10 FEET (NEC 690.3 1 (G)(3), IFC 605.11.1.2) ►,/:�:i.l ►[e3ii:[�yC�Pl�7N��[�lZ�]� I�:��ili:t� THIS LABEL TO BE INSTALLED AT THE ENERGIZED DISCONNECTING MEANS. (PER NEC 690.15 & NEC 690.53, IFC 605.11.1, & IFC 605.11.1.4) MAIN PV SYSTEM DISCONNECT THIS LABEL TO BE AT THE MAIN ELECTRICAL SERVICE PANEL. (PER NEC 690.56(C)(L)A PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PERMANENT SIGNAGE NOTES 1. ALL LABELS / PLAQUES AND SIGNAGE IS REQUIRED BY THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE AS REQUIRED. PROVIDE ALL WARNING, LABELS AND MARKINGS AS REQUIRED IN THE 2017 NEC. 2. PROVIDE ALL LABELS, CODE REFERENCES AND SPECIFICATIONS IN COMPLIANCE WITH 2O17 NEC ARTICLE 690 NEC SOLAR PHOTOVOLTAIC AND ARTICLE 705 INTERCONNECTED ELECTRIC POWER PRODUCTION SYSTEM. 3. PROVIDE WARNINGS, LABELS, MARKINGS AND THE LOCATION WHERE THEY SHALL BE INSTALLED, AS SPECIFIED IN ARTICLE 690 NEC, 705 FOR SOLAR PHOTOVOLTAIC SYSTEMS. 4. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 2017 NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION 5. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE" PER NEC 705.10 AND 'BREAKERS ARE BACKFED" PER 690-64(B)(5). LABEL MAXIMUM A/C OUTPUT OPERATING CURRENT AND OPERATING VOLTAGE PER NEC 690.54 6. LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH", SWITCH COVER TO BE LOCKED AT ALL TIMES, SWITCH TO BE ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22 7. LABEL "PHOTOVOLTAIC POWER SYSTEM DEDICATED KWH METER" 8. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD -DO NOT TOUCH TERMINALS- TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. 9. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(B) 10. METALLIC CONDUIT SHALL BE USED WITHIN MWOw &E) RE�,�'� $ED JCTMOMBINER PA (IF USED , AD DO NOT AD S TO THIS PANEL SHEE f : F: RELE, kSE DOESFINMAUlt4DRFICATION, OONRJCT V IITH THE "MWGSWDffopVoNWWoRDNVMEG. 'PROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: -2/911= BY: 5;1-?• BUIL61NG INSPECTION DIVISION: RELEA: iE DOES NOT APPLY TO CONSTRUCTION IN E►SEMENTS OR PUBLIC RIGHT-OF-WAY. ALL 01HANGES MUST BE APPROVED V W 7 •--{ �--� hey w � REVISIONS: DRAWN BY: ND DATE: 06/28/2019 PLACARDS SHEET: 6 N_ 00 0 '4 PHOTOVOLTAIC SYSTEM SIE:STANDARD ECO 9 Brittain Residence 10.00 kW AC 110 E. Houston St., 2600 Pool Road Grapevine, TX 76051 11.16 kW DC San Antonio, TX 78205 SINGLE PHASE 120V/240V TX License #:32439 solar=ee SolarEdge Power Optimizer Module Add -On For North America P300 / P320 / P370 / P400 / P405 PV power optimization at the module -level — Up to 25% more energy - Superior efficiency (99.5%) - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization - Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA dge.us solar=@@ SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P370 / P400 / P405 P370 P300 P320 P400 P405 for 60-cell mad- for high -power ( (for (for higher -power 72 & 96-cell {for thin film ules) 60-cell modules) 60 and cell modules) modules) — -_,— le modules) _ — INPUT Rated Input DC Powerl'! ............................ 300 320 _ W Absolute Maximum Input Voltage ..................370..................400........ ........405..... ......... (Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 ...................................... 12.5 - 105 .................. Vdc Maximum Short Circuit Current...I. .............................n't(Is..................-..........I..,.......... 10 11 10:1 ... ........................... Adc..... Maximum DC Input Current ..............I................1................................... 12.5 E 13:75 12:63 Adc Maximum Efficiency 99.5 % Wei hted Eff cienc ......g....--..I ............................ 98.8 % ... Overvoltage Category_ _ _ _ _ _ _ _ _ II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximu.m Output Current 15 A dc . ....... Maximum Output Voltage ........................... .._oltage _ 60 , Vdc_ _85 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) _ Safety Output Voltage per Power _Optimizer �- -- - - - -- -- -- - 1 - - Vdc STANDARD COMPLIANCE EMC -..-.1............................. FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ..-.-.-..-.--.. .............. Safety ...... ....... .......... ............... .................................... ............... ......... IEC62109-1 (class ll safety), UL1741 _RoHS _ _ _ Yes -INSTALLATION SPECIFICATIONS - — — �— — Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128x152x35/ 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128x152'x50/ mm / in Sx5.97x1.37 5x5.97x1.96 Weight (including cables) 630 / 1;4 750 / 1.7 .. .................................................................... 845 / 1.9 gr / Ib MC4 / Input Connector MC4 Compatible Amphenol AH4MC4 Compatible ..... ... .................. I . Double Insulated; Output Wire Type / Connector Double Insulated; MC4 Compatible MC4 / Double Insulated; MC4 Compatible Amphenol AH4 Output Wire Length ......... 0 95 j 3 0 1.2 / 3 9 m/ ft Operatin�TemperatureRanpe _......... -40-+85/ 40-+185 "C/'F Protection .Rating ............. ......... . IP68 / NEMA6P Relative Humidity 0 - 100 % ("Rated STC power of the module. Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING _ SINGLE PHASE A SOLAREDGE INVERTER(21(3) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V HD -WAVE Minimum String Length (Power Optimizers) g 10 18 Maximum String Length (Power Optimizers) 25 25 50 5700 (6000 with Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations ............................................................................................. Yes . 4'1 For detailed string sizing information refer to: http://www.sulareclge.com/sites/default/files/string_sizing_na.pdf ''it is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string solar =@" Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-L SE6000H-US / SE760OH-US / SE10000H- solar m. "wart#'- r� e� WattanW g , 44 ! Optimized installation with HD -Wave technology Specifically designed to work with power optimizers Record -breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small — High reliability without any electrolytic capacitors �,� — Built-in module -level monitoring — Outdoor and indoor installation wave — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) www.solaredge.us solar=@@Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US _ SE3DOOH-US I 0H SE380-US SESOOOH-US --- SE6000H_US SE760OH-US ! SE10000H-US SE1140OH-US OUTPUT - - --- - - - - --- --- Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ...... ._. ,3..... . 08V 5000 �,208V, Max. AC Power Output 3000 3800 @ 240V 5000 6000 @ 2401! 7600 10000 11400 VA 3300. 208y................. . 5000 @, 208V, ............. . ................ AC Output Voltage Min.-Nom: Max. � (183-208 Z29) _ Vac .......................... AC Output Voltage Min.-Nom: Max. . Vac (211.; 240 - 264)........................... 1................�............ . ... AC Frequency (Nominal) ............... 59.3.:60.:60:51'..,........ Hz Maximum Continuous Output Current ..................... 208V..................................... 16 24 A Maximum Continuous Output Current 240V...... 12.5 16 21 ............... 25 ............................ 32 42 ...... 47.5 ........... A GFDI Threshold 1 A Utility�Nloriitoring, Islencl�ing�Proti=ction, .................. CountEyCon K!!rableThresholds-_L____ ___- —_ Yes INPUT Maximum DC Power @240V ........................................................................................... 1 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 ....,.,,..............,.. ............................... 7750 - ........ Transformer -less, Un rounded �.................... Maximum In ut Volta a !?........�................ ....,Yes ................... 480 Vdc Nominal DC Input Voltage ... 380 400 Vdc Maximum Input Current 208V 9 ( 13 5 Maximum Input Current @240V...... ............................ 8:5...........105......1..... .......... ..... 135...... �......165......1...... ZO.. ?? Max. Input Short Circuit Current ............. .............30:5..... 45 Adc Reverse -Polarity Protection .. .. .. .................. Yes Ground -Fault Isolation Detection ..................2.......................................... 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Wei hted Efficiency ....................................................,............. 99 .... .,., 30 Nighttime Power Consumption— W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (o tional), Cellular o tional ......... ............................. P.................. I . P....... ).. Revenue Grade Data, AN51 C12,20 OptionaliZl .......................... Rapid Shutdown - NEC 2014 and 2017 690 12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE - - Safety UL1741, UL1741 SA, UL16998, CSA C22:2: Canadian AFCI according to T.I. L; M .07_ Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) ...................14(H.................................. Emissions _ _ FCC Part_15 Class B ... ......... INSTALLATION SPECIFICATIONS _ _ AC Output Conduit Size / AWG Range 3/4" minimum / 14-6 AWG minimum /14-4 AWG DC Input Conduit Size / # of Strings / 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / AWG,Rang? ............................... AVVG............ Dimensions with Safety Switch (HxWxD) ........ ............14:6 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 % 540 x 370 . . in / mm x 185 .............................. Weight with Safety Switch ............. ................ 22 / 10 25.1 / 11.4 i 26.2 / 11.9 38.8 / 17.61. Ib k Noise .................................. <25 ............................................... <50 dBA Cooling Natural Convection ................................................ Natural convection Operating Temperature Range ..• 13 to +140 / 25 to +60i31 (40`F % :40'C option)I"i,. . F / .. Protection Rating NEMA 3R (Inverter with Safety Switch) Itl For other regional setngs please contact SolarEdge support 1�1 Revenue grade inverter P/N: SExxxxH-US000NK2 iat For power de -rating information refer to: https://www,solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf i4i -40 version P/N: SE—H-US000NN1.14 FM U a:i�.11 CERTIFIED RELIABILITY > Tested to UL1703 & IEC standards > PID Resistant SUPERIOR AESTHETICS > All -black design coupled with outstanding power output > Ideal for residential & commercial applications 13 EXTREME WEATHER RESILIENCE > 5631 Pa snow load (117 psf) tested load to UL1703 > 185 mph wind rating* BAA COMPLIANT FOR GOVERNMENT PROJECTS > Buy American Act )American Recovery & Reinvestment Act I AP LINEAR WARRANTY PRODUCT WARRANTY 300-qlOW 100% 97% Mission Solar Energy Warranty j 90.7% CLASS LEADING POWER OUTPUT 90% o 80.2%! 80% I 18.6 / 70% MAXIMUM EFFICIENCY 1 5 10 15 20 25 YEARS _0,il + 3 940 POSITIVE POWER TOLERANCE High -Power, American Quality Mission Solar Energy is headquartered in San Antonio, TX with module facilities onsite. We produce American quality poducts ensuring the highest power output and reliability to our customers. Our product line is well suited for residential, commercial and utility applications. Every Mission Solar Energy product is certified and surpasses industry standard regulations, proving excellent performance over the long-term. www.missionsolar.com I info@missionsolar.com CERTIFICATIONS IEC 61215/ IEC 61730/ IEC 61701 UL 1703 -�', I:l us PQw�r�uard CEC \_:- LISTED 'As there are different certification requirements in different markets, please contact your local Mission Solar Energy sales representative for the specific certificates applicable to the products in the region in which the products are to be used. `185 mph wind rating based upon installation at 30* or less fixed tilt mount TM MISSION SOLAR 0i ENERGY ■0 11 PERC 60 SPECIFICATIONS .ELECTRICAL Electrical Parameters at Standard Test Conditions (STC) Module Type MSE300SQST MSE305SQBT MSE310SQ8T Power Output Pmax Wp 300 305 310 Module Efficiency % 18.05 18.35 18.65 Tolerance 0-+3% 0-+3% 0-+3% Short -Circuit Current Isc A 9.571 9.664 9.760 Open Circuit Voltage Vac V 40.08 40.10 40.12 Rated Current Imp A 9.058 9.202 9.345 Rated Voltage Vmp V 33.12 33.14 33.17 Fuse Rating 15 20 20 Normal Operating Cell Temperature (NOCT) 46.09*C (±2°C) Temperature Coefficient of Pmax -0.377%/°C Temperature Coefficient of Voc -0.280%/*C Temperature Coefficient of Isc 0.039%/°C Log i.g a11►+ tl� Maximum System Voltage 1,000VDC Operating Temperature Range -40°C (-400F) to +85°C (185*F) Maximum Series Fuse Rating 20A Fire Safety Classification Class C Front &Back Load (UL standard) 5631Pa (117 psf) Tested toUL1703 standard Hail Safety Impact Velocity 25mm at 23 m/s Solar Cells P-type Mono -crystalline Silicon (156.75mm) Cell orientation 60 cells (6x10), 5 busbar Module dimension 1664mm x 999mm x 40mm (65.53 in. x 39.33 in. x 1.58 in.) Weight 18.2 kg (40.1 lb) Front Glass 3.2mm (0.126 in.) tempered, Low -iron, Anti -reflective coating Frame Anodized aluminum alloy Encapsulant Ethylene vinyl acetate (EVA) J-Box Protection class IP67 with 3 bypass -diodes Cables PV wire, 1m (39.37 in.), 4mm2 / 12 AWG Connector MC4 SHIPPING INFORMAT19U. Container FT Pallets Panels 305 W 53' Double stack 36 936 285.48 kW 40' Double stack 28 728 222.04 kW Panels Weight Height Width Length Pallet 26 1,105lbs 45.50" 45.50" 67.00" Mission Solar Energy reserves the right to make specification changes without notice CLASS LEADING 300-31OW IEC 61215/61730/61701 UL UL 1703 listed Snus PoWe.,Guord CEC UmIll MSE305SQ8T: 305WP, 60CELL SOLAR MODULE CURRENT -VOLTAGE CURVE 12 Cells Temp. 10 a N 6 c 0 U a 2 - 0 Incident Irrd•=1,000 2 W/m 305.1 W Incident Irrd.=800 2W/m 2• A W Incident Irrd.=600 2W/m !. 1. W Incident Irrd.=400 zW/m 123 L Incident Irrd.=200 'W/m 5' VY t 0 20 30 20 Voltage [V] Current -voltage characteristics with dependence on irradiance and module temperature BASIC DESIGN (UNITS: mm) - 3�:A z� - irlili )J 11I 1111 1 Front View �e 50 _ I 35.00 I 'F ' --Drain -� Hole �I 297.00 , ! I . 1-� 77.00 832.00 ' f ! Mo- unting Hole I, I ii -)---Y, Grounding Hole eaz oo II' 4- I�, 1 ,000 _�- I Back View 1 MISSION SOLAR ENERGY sue' < Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235 info@missionsolar.com I www.missionsolar.com "A& IRONRIDGE Integrated Grounding System Installation Overview Simplified Grounding Fnr (',rPatPr RnfPty R I rnn/ar (r),zt Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. londing Strap onding Straps are used to )nd rail -to -rail connections. hey are only required on the til with the grounding lug. #' Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Install Roof Attachments • Install appropriate roof flashing and/or standoff for roof type • Attach L-Feet to flashing or standoff. Prepare Rail Connections • Insert splice into first rail, then secure with Bonding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. 0 Mount & Ground Rails • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm A B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Mid Clamp has proven robust in grounding solar modules with a box frame construction, a range of anodization thicknesses and nominal lengths of 78.5' or less. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ironridge.com/ig Jilt ngattr. rvwrr.ironrtd WCJA t-aw:227-W3 for more tnfor 1pnwai.... - /-,! � f is, Manual .,'.lt I RON RI DGE Installation Once the end module is set into position, place second module into position, leaving a 1/2" gap between it and the previous module. While holding module in place, drop Grounding Mid Clamps into rail slots and rotate nuts to engage T-bolts. Slide second module flush against clamp tabs. Once clamp teeth are in contact with both module frames and the bolts are properly aligned in slots, torque to 84 in-Ibs (55 in-Ibs for SunPower modules). Repeat procedure for each following module. ► Make sure indent at top of T bolt is perpendicular to rail slot to ensure T bolts are properly seated. ► If grounding mid clamps need to be reinstalled, slightly move the modules so that clamp teeth are in contact with a new section of the module frame. Markings Markings are located on the top surface of the Grounding Mid Clamp and being with the manufacturing and model number followed by the revision and manufacturing date. Manufacturer and model number: IR Revision and manufacturing date: First digit (revision code): A = Rev A, B = Rev B, etc. Second digit (month produced): A = Jan, B = Feb, etc. Third & fourth digits (year produced): 15 = 2015, etc. Ratings Max Overcurrent Protective Device (OCPD) Rating: 25A Installer is responsible for and shall provide an appropriate method of direct -to -earth grounding according to the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. If loose components, loose fasteners or corrosion are found during periodic inspection, replace affected components immediately. Grounding Mid Clamp Leave � 1. Drop in Clamps ap Between Parallel to Rail Modules - „r. 2. Rotate Nuts to Engage Bolts Place Second Module into Position in Rail Slot Torque to 84 in-Ibs (55 in-n-Ibsbs for SunPower modules) - --------_-- T-Bolt Indent Perpendicular to Rail i IR AA01 0 7OPS = ErLtx Module Compatibility The Grounding Mid Clamp may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. AstroEnergy Solar Modules with 35, 40, and 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" can be CH or A; "yy' can be either 10 or "zz" 12; can be blank or (BL). Modules with 40mm frames and model identififer CS6Y-xxxZ; where "Y" can be K, P, V, or X; and ""Z"" can be M, P, PX, or P-SD. Modules with 35, 40, and 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" can be P, L, or M; "ZZ" can be 60 or 72; and Canadian Solar ET Solar "AA" can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" can be either PB or MB. Modules with 40, 45, and 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" can be either 60 or 72; "YY" can be Hanwha Solar PA or PB; and "Z" can be blank or B. Hanwha O CELLS Modules with 32, 35, 40, and 42mm frames and model identifier O.YY-ZZ-xxx; where "YY" can be PLUS, PRO, or PEAK; and "ZZ" can be G3, G4, L-G2, L-G3y, L-G4y, BFR-G3, BLK-G3, BFR-G4, BFR-G4.1, or G4.1/SC. Hyundai Modules with 35 and 50mm frames and model identifier HiS-YxxxZZ; where "Y" can be M or S; and "ZZ" can be MI, MF, MG, SG, Rl, RG, TI, or TG. Modules with 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy' can be M6 or P6; "zz" can be blank, (K), (L), JA Solar (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; and "aa" can be MP, SI, PR, 386, 4BB, 4BB/RE. Jinko Modules with 35 and 40mm frames and model identifier JKMYxxxZZ; where Y' can either be blank or S; and "ZZ" can be M, P, PP, P-B, or P-V. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" can be D or U; "ZZ" can be blank, GX, or SX; and "AA" Kyocera can be LPU, LFU, UPU, LIPS, LPB, ,LFB, LFBS, LF132, LP62, 3AC, 313C, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 5131C, 5FC, 5UC, 6BC, 6FC, or 813C. LG Modules with 35, 40, and 46mm frames and model identifier LGxxxyl z-bb; where "y" can be A, N, or S; "z" can be C or K; and "bb" can be A3, 133, G3, C4 or K4. Mistubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, and 50mm frames. Panasonic Modules with 35mm frames and model identifier VBHNxxxSAyy; where "yy" can be either 06, 068, 11, 11 B, 15, 156, 16 or 1613. Phono Solar REC Solar Renesola SolarWorld Stion SunEdison Suniva Sunpower RECOGNIZED COMPONENT Suntech Trina �i�)Us Winaico Intertek 4008083 Yingli Modules with 35, 40, and 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" can be M or P; "ZZ" can be 20 or 24; and "A" can beF,TorU. Modules with 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" can be M, PE or TP; and "ZZ" can be blank, BLK, SLV, or 72. Modules with 35, 40 and 50mm frames and model identifier JCxxxY-ZZ; where "Y" can be F, M or S; and "ZZ" can be Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Sunmodule Plus, Protect or XL mono or poly modules with 31, 33 or 46mm frames and model identifier SW-xxx. Thin film modules with 35mm frames and model identifier STO-xxx. Modules with 35, 40, and 50mm frames and model identifier SE-YxxxZABCDE; where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be B, C, D, E, H, I, J, K, L, M, or N; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2. Modules with 35, 38, 40, 46, and 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1BO, or 161; and "Z" is blank or B. SPR-A-xx series with standard (G3) or InvisiMount (G5) 46mm frames; where "A" is either E or X; and "xx" is the series number Vd, Vem, Wdb, Woe, and Wd series modules with 35, 40, and 50mm frames. Modules with 35, 40 and 46mm frames and model identifier TSM-xxxYYZZ; where "YY" can be PA05, PC05, PD05, PA14, P014, or PD14; and "ZZ" can be blank or A or A.05 or A.08. Modules with 35 and 40mm frames and model identifier Wsy-xxxz6; where "y" can be either P or T; and ""z"" can be either M or P. Panda, YGE, and YGE-U series modules with 35, 40, and 50 mm frames. �= 0 2015 IronFtidge, Inc- All nghls t**&v@'d. ► on wwwurwwidge.com or call 1-40W 7-9 z I- rnara fMorpn+filon. Vee�Qn t.�7 AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc Address: 1495 Zephyr Ave Hayward, CA 94544 Country: USA Contact: Yann Schwarz Phone: (800) 227-9523 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008083 Authorized by: Manufacturer: Precision Die & Stamping, Inc Address: 1704 W. 10th Street Tempe, AZ 85281 Country: USA Contact: Andy Frola Phone: (480) 967-2038 FAX: (480) 829-0838 Email: andy@precisiondie.com z�l kAVI for Thomas J. Patterson, Certification Manager Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any parry, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: IR XR followed by 4 Alphanumeric Characters ATM for Report 101541132LAX-002 Page 2 of 2 ATM Issued: 28-Jan-2016 ED 16.3.15 (1-Jan-13) Mandatory IRONRIDGE olar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. J11i XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. to XR Rail Family Compatible with Flat & Pitched Roofs Corrosion -Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine -grade A compatible with 52Va range of tilt leg aluminum alloy, then protected with an FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof roof mounting and structural corrosion, while also providing sh-10- attachments. applications. a more attractive appearance. CLASSIFICATION Constructional Data Report (CDR) 11.0 Reference and Address Report Number 101541132LAX-002 Original 22-May-2014 Revised: 15-Jan-2016 Standard(s) UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Applicant IronRidge, Inc Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Contact Yann Schwarz Phone (800) 227-9523 (510)225-0973 FAX (707) 459-1833 Email vschwarzedi iron rid ile.com Manufacturer 2 Precision Die & Stamping, Inc. 1704 W. 10th Street Address Tempe, AZ 85281 Country USA Contact Andy Frola Phone (480) 967-2038 FAX (480) 829-0838 Email andW,:'( recisiondie.com Manufacturer 1 IronRidge, Inc. Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Contact Jim Norsworthy Or Dave Taggart Phone (707) 363-3025 (800) 227-9523 FAX (510) 225-0975 Email inorsworthv( ironridce.com dtaaaart&..ironridae.com Page 1 of 86 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. intertek's responsibility aril liability are limited to the terms and conditions of the agreement. Intertek assures no liability to any party, otter than to the Client in accordance with the agreement. for any loss, expense or damage occasioned by the use of this report. Only the Client is aulhofized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek_ The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Report No. 101541132LAX-002 Page 2 of 86 Issued: 22-May-2014 IronRidge, Inc. Revised: 15-Jan-2016 2.0 Product Description Product XR Rails with Integrated Grounding. Brand name IronRidge Roof Mount The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to extend their length. A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic modules to the system. The End Clamps are not used as a grounding means. The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel serrated T-Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a Description specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection from module to module and module to rail. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T-Bolt, flat washer, split lock washer, and nut, tightened to manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel T-bolt, k-lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models IR XR followed by 4 Alphanumeric Characters Model Similarity N/A Fuse Rating: 20 A Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. Ratings - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. - Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. - Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. ED 16.3 15 (1-Jan-13) Mandatory Report No. 101541132LAX-002 IronRidge, Inc. 2.0 Product Descri Page 3 of 86 Issued: 22-May-2014 Revised: 15-Jan-2016 These systems were evaluated or tested for bonding ana grounamg wain the toliowing PV- Module frames: Motech - Black or Silver Frames Models: IM and XS series, 60 and 72 cell modules with 40 mm frame height. IM and XS series, 60 and 72 cell modules with 45 mm frame height. IM and XS series, 60 and 72 cell modules with 50 mm frame height. Suntech - Black or Silver Frames Models: Wdb, Wde, and Wd series, 60 and 72 cell modules with 35 mm frame height. Vd series, 60 and 72 cell modules with 50 mm frame height. ET Solar - Black or Silver Frames Models: ET Solar 60 cell modules with 35 and 40 mm frames ET-Y660xxxZZ Where "Y" can be P, L, or M; "xxx" refers to the module power rating; "ZZ" can be WB, WW, BB, WBAC, or BBAC ET Solar 72 cell modules with 40 and 50 mm frames ET-Y672xxxZZ Where "Y" can be P, L, or M; "xxx" refers to the module power rating; "ZZ" can be WB, WW, BB, or WBG Hyundai - Black or Silver Frames Models: SG, MG, RG and TG Series, 60 cell modules with 35 mm frame height. MI, RI and TI Series, 72 cell modules with 50 mm frame height. Yingli - Black or Silver Frames Models: Panda and YGE models, 60 cell modules with 40 mm or 35 mm frame height. YGE models, 72 cell modules with 50 mm or 40 mm frame height. Kyocera - Models: KD(xxx)GX-LPU, KD(xxx)GX-LFU, KD135SX-UPU, KD(xxx)GX-LFBS, KD(xxx)GX-LPB KD(xxx)GX-LFB, KD(xxx)GX-LFB2, KD(xxx)GX-LPB2 KD135GX-LPS, KD140GX-LPS, KD140SX-UPU KU(xxx)-3AC, KU(xxx)-4AC, KU(xxx)-5AC, KU(xxx)-3BC, KU(xxx)-4BC KU(xxx)-5BC, KU(xxx)-6BC, KU(xxx)-8BC, KU(xxx)-3FC, KU(xxx)-4FC KU(xxx)-5FC, KU(xxx)-6FC, KU(xxx)-4UC, KU(xxx)-5UC. Where xxx refers to the module power rating Canadian Solar - Black or Silver Frames Models: CS6P-M 60 Cell Modules with a 40mm frame height. CS6P-P 60 Cell Modules with a 40mm frame height. CS6X-M 72 cell modules with a 40mm frame height. CS6X-P 72 cell modules with a 40mm frame height. Report No. 101541132LAX-002 IronRidge, Inc. 2.0 Product Other Ratings Page 4 of 86 Issued: 22-May-2014 Revised: 15-Jan-2016 LG Modules - Black or Silver Frames Models: LG 60 cell modules with 35 mm frames: LGxxxy1z-b3 Where xxx is the module power rating, "y" can be A,N or S, 'Y' can be C or K, and "b" can be A, B, or G. LG 60 cell Modules with 40mm frames: LGxxxy1 z-G4 Where "xxx" is the module power rating, "y' can be N or S, and 'Y' can be C or K LG 72 Cell Modules with 46mm frames: LGxxxy2z-b3 Where "xxx" is the module power rating, "y" can be N or S, 'Y' can be C or K, and "b" can be A, B, or G Suniva Modules - Black or Silver Frames Models: 60 Cell Modules with 35 and 40mm frames: O PTxxx-60-A-YYY-Z M VXxxx-60-A-YYY-Z Where "xxx" is the module power rating, "A" is either 4 or 5, "YYY" is either 100,101,700,1 B0, or 1131, and 'Y' is blank or B. 72 Cell Modules with 38, 46, and 50mm frames: OPTxxx-72-A-YYY-Z MVXxxx-72-A-YYY-Z Where "xxx" is the module power rating, "A" is either 4 or 5, "YYY' is either 100,101,700,1 BO, or 1131, and "Z" is either blank or B Hanwha Modules - Black or Silver Frames Models: HSL72P6-PA-1-xxx(50mm frame) HSL72P6-PB-1-xxx(45mm frame) HSL60P6-PB-1-xxx(40mm frame) HSL60P6-PA-1-xxx(45mm frame) The model number can be followed with a "B" Where xxx is the module power rating Trina Solar Modules - Black or Silver Frames Models: TSM-xxxPA05 (35mm frame height) TSM-xxxPC05 (35mm frame height) TSM-xxx-PD05 (35mm frame height) TSM-xxxPA05 (40mm frame height) TSM-xxxPA14 (46mm frame height) TSM-xxxPD14 (40mm frame height) TSM-xxxPC14 (40mm frame height) The model number can be followed by A and .05 or .08 Where xxx refers to module power rating ED 16.3.15 (I-Jan-13) Mandatory ED 16.3.15 (1-Jan-13) Mandatory Report No. 101541132LAX-002 Page 5 of 86 Issued: 22-May-2014 Report No. 101541132LAX-002 Page 6 of 86 Issued: 22-May-2014 IronRidge, Inc. Revised: 15-Jan-2016 IronRidge, Inc. Revised: 15-Jan-2016 2.0 Product Description 2.0 Product Description SolarWorld Modules - Black or Silver Frames Models: Sunmodule Plus SW-xxx, Sunmodule Protect SW-xxx, Sunmodule XL SW-xxx Mono or Poly with 31, 33, or 46 mm frame height. Where xxx refers to the module power rating Phono Solar Modules - Black or Silver Frames Models: PSxxxP-20/U, PSxxxM-20/U, PSxxxP-24/T, PSxxxM-24/T with 40mm frame height Where xxx refers to module power rating SunEdison modules - Black or Silver Frames Models: SE-QxxxBCC-3Y, SE-MxxxBCC-3Y, SE-FxxxBCC-3Y, SE-PxxxBCC-3Y, SE-QxxxBMC-3Y SE-MxxxBMC-3Y, SE-FxxxBMC-3Y, SE-DxxxBMC-3Y, SE-PxxxBMC-3Y with 50mm frame height. Where xxx refers to module power rating Hanwha Q CELLS modules - Black or Silver Frames Models: Hanwha QCells 60 cell modules with 32 mm frames Q. PL U S-G4-xxx Q.PRO BFR-G4-xxx where xxx refers to module power rating Hanwha QCells 60 cell modules with 35 mm frames: Q.PRO-G3-xxx Q. PRO-BFR-G3-xxx Q.PEAK BLK G3-xxx Q.PLUS G3-xxx where xxx refers to module power rating Hanwha QCells 72 cell modules with 35 mm frames: Q.PRO L-G4y-xxx Q.PLUS L-G4y-xxx where "y" can be blank, 1 or 2 and "xxx" refers to module power rating Hanwha QCell 72 cell modules with 40 mm frames: Q.PRO L-G2xxx Q.PRO L-G3y-xxx where "y" can be blank or 1 and "xxx" refers to module power rating Hanwha QCell 72 cell modules with 42 mm frames: Q.PRO L-G2-xxx where "xxx" refers to module power rating Renesola Modules - Black or Silver Frames Models: Mono and Virtus II Modules: JCxxxM-24/Abh, JCxxxS-24/Abh, JCxxxF-24/Abh, JCxxxM-24/Abh-b, JCxxxS-24/Abh-b JCxxxF-24/Abh-b, JCxxxM-24/Ab, JCxxxM-24/Abv, JCxxxS-24/Ab, JCxxxF-24/Ab JCxxxM-24/Ab-b, JCxxxM-24/Abv-b, JCxxxS-24/Ab-b, JCxxxF-24/Ab-b with 50mm frame height. JCxxxM-24/Bb, JCxxxM-24/Bbv, JCxxxS-24/Bb, JCxxxF-24/Bb, JCxxxM-24/Bb-b JCxxxM-24/Bbv-b, JCxxxS-24/Bb-b, JCxxxF-24/Bb-b, JCxxxM-24/Bbh, JCxxxS-24/Bbh JCxxxF-24/Bbh, JCxxxM-24/Bbh-b, JCxxxS-24/Bbh-b, JCxxxF-24/Bbh-b with 40mm frame height. JCxxxS-24/Db, JCxxxF-24/Db, JCxxxS-24/Db-b, JCxxxF-24/Db-b with 35mm frame height. Where xxx refers to the module power rating. Sunpower Modules- Black or Silver Frames Models: SPR-E-xx series with standard (G3) or InvisiMount (G5) 46 mm frame SPR-X-xx series with standard (G3) or InvisiMount (G5) 46 mm frame. where xx is the series number Panasonic Modules - Black or Sliver Frames Models: VBHNxxxSA06, VBHNxxxSA06B, VBHNxxxSA11, VBHNxxxSA11 B with 35 mm frame height. Where xxx refers to the module power rating Winaico Modules - Black or Silver Frames Models: Winaico 60 Cell modules with 35 and 40 mm frames W sy-xxxz6 Where "y" can be either P or T, "xxx" is the module power rating, and 'Y' can be either M or P Mitsubishi Modules - Black or Silver Frames Models: PV-MYYxxxzz Where YY can be LE or JE, xxx is the module power rating, and ZZ can be either HD, HD2, or FB Jinko Solar Modules - Silver Frames Models: JKMxxxP-60: Where xxx is the module power rating between 250-270 in increments of 5. JKMSxxxP: Where xxx is the module power rating between 255-270 in increments of 5. JKMxxxPP-60: Where xxx is the module power rating between 255-270 in increments of 5. ED 16.3,15 (1-Jan-13) Mandatory ED 16.3.15 (1-Jan-13) Mandatory 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279tek www.inter-com Test Verification of Conformity sm_ Starling Madison Lafquist, Inc, r r. 5224 South 3r Street, Phoenix, Anixona 85040 tel: (602) 438-2500 fox: (602) 438-2505 ROC#E291316 www.smleng.cam IronRidge February 15, 2019 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of 28357 Industrial Boulevard Page 1 of 21 the referenced specifications at the time the tests were carried out. Hayward, CA 94545 iApplicant Name & Address: IronRidge, Inc. 1, Attu: Mr, Carey Geiger, Vice President New Markets 1495 Zephyr Ave. Hayward, CA 94544 Subject: IronRidge XRt(lili Rail, Roof Flush Mounting System — Structural Analysis USA Product Description: XR Rails with Integrated Grounding. Dear Sir: Ratings & Principle Fire Class Resistance Rating: We have analyzed the IronRidge XRHHI Rail for the subject solar module support system and Characteristics: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 determined (bat, for the configurations and criteria dcseribed below, it is in compliance with the and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, applicable sections of the following Reference Documents_ 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. Codes: ASCUSEI 7-10 Min. Design Loads for Buildings &Other Structures International F3ttild.illtg Code 2012 Edition Models: 51-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Brand Name: IronRidge Roof Mount Modules, dated Effective November 1, 2012 by ]CC -ES Relevant Standards: UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Aluminum Design I%IanuaL 2010 Edition Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, The IronRidge XRl00 Rail is an extruded aluminum section with an overall depth of 2.438 in, and a 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. net area of il.583 sq.in. The rails are used to support solar modules, typically, on the roof of a Verification Issuing Office: Intertek Testing Services NA, Inc. building. See Exhibit 0011— attached_ The modules are clamped to the rails by the IronRidge 8431 Murphy Drive Module 'Mounting Clamps, as shown in the attached Exhibit, The rails are attached to aluminum Middleton, WI 53562 angle brackets that are either attached directly to the roof framing or attached to a stand that is Date of Tests: 08/27/2014 to 03/17/2015 screwed to the roof framing- The rails are mounded across the slope with a small clearance (flush Test Report Number(s): 101769343MID-OOlr1, 101769343MID-001a,101915978MID-001 & 101999492MID-001arl-crl. mounting) to the tuiderlying roof Structure. The installed solar modules are at the Same Slope as the This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically underlying roof structure. imply product certification. Completed by: Chad Naggs Reviewed by: GregoryAllen All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of Title: Technician II, Fire Resistance Title: Engineering Team Lead, Fire Resistance the rails. The maximum span of the rails is governed by either the mid -span flexural strmes or the deflection requirement that the rail not come into contact with the roof. Signature: Signature:] Date: 03/30/2015 Date: 03/30/2015 The effect of seismic loads (for all design categories A-F) have been determined to be less than the efTect due to wind leads in all load conditions and combinations, Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables 1 A-9A are for modules with a 'cables maximum lung distension of 67.5 inches and I B-9B are for modules with a maximum tang — _ - dimension of 78.5 inches. This Verification is for the exclusive use of lntertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client m accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its Starling Nladison Lofquist, Inc. Consulting Structural and Forensic Engineers marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results Texas Firm Registration #F-16420 referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under on Intertek certification program. GFT-OP-13a (24-MAR-2014) ' r IronRidge Mr, Carey Geiger IronRidge YR100 Rail, Roof 1=htsh Mounting System — Stnlctural Analysis Modulo Glass fCe'lls Frorne Coirnpsiitiiity, X - I.2. 2.2 myrt 'f=15.40mm i' -x February 15, 200 Page 21 of 21 Figure 8: CAN-10 [`.lamp Module Frame f)imcnsional Requirements Our analysis assumes that the rail;, including the connections and associated hardware., am installed in a workmanlike manner in accordance v6th the IrorlRidge Flush Mount Trt.Stallation Manual" by lronRldge and gcncrally accepted standarrls of construction practice. Additional information is a vailable It the IronRidge web site:, IronRidge,conl. 4ferjlication of PV Module capacity to support the loads associated with the given array shall be lihe responsibility of the Contractor of Owner and not lronitiJgc or Starling Madison Lofquist. The adequacy of the supporting, roof framing is to be determined by others. Please feel line to Contact tile at your convenience if you have any questions,, Respectfully yours, Tres Warner, P,tr, • '•.*� Design Division Manager h................. TREE J. WARNER Digitally signicd tsyTrt;3 I Warner Trey DN: c-US omStarling Madison Lofqulst Inc, 0 u=A014z73w00153 B F918), Cn rrn -Tres JNarner Date. 2w 9.02.- 9 1429:07-47'O6' Starling Madison Lofquisy Inc, Cc►r,sulting SuUCLUtal and Forensic Engitrcers Texas Firm Registrsttion 4117-16420 AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc 1495 Zephyr Ave Address: Hayward, CA 94544 Country: USA Contact: Yann Schwarz Phone: (800)227-9523 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008377 Authorized by: Manufacturer: IronRidge, Inc Address: 1495 Zephyr Ave Hayward, CA 94544 Country: USA Contact: Jim Norsworthy Or Phone: (707)363-3025 FAX: (510)225-0975 Email: jorsworthy@ironridge.com IT for Thomas J. Patterson, Certification Manager Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number This Authorization to Mark is for the exclusive use of Intertek's Client and Is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement. for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Fallow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: IronRidge Roof Mount Models: IR XR followed by 4 Alphanumeric Characters ATM for Report 101541132LAX-002 Page 1 of 2 ATM Issued: 28-Jan-2016 ED 16.3.15 (1-Jan-13) Mandatory June 20, 2014 Mr. Meir Adest SolarEdge Technologies Ltd 6 Ha'Harash St. HOD HASHARON, ISRAEL 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G 10 1703554 Ph: +972.9.957.6620 email: meir.a@solaredge.com Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: 0 Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 • 1-ph Inverters: o SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Pagel of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. FJ f Wi Appiwed Intertek Intertek intertek Irztei tek Intertek Intertek Intertek Testing Services NA, Inc. SD 12.12 (11/11110) Informative SolarEdge Technologies Ltd • 3-ph Inverters: Letter Report 101703554CRT-001 June 201h, 2014 o SE9KUS / SEIOKUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Signature: Engineering Team Lead -�----- 7^ Title: Signature StaffEngineer Date June 20m, 2014 Date: June 20` , 2014 Intertek Testing Services NA, Inc. Page 2 of 2 So 12.1.2 (11/11/10) Informative