HomeMy WebLinkAboutSFRA2020-3125City of Grapevine
P.O. Box 95104
Grapevine, TX 76099
(817) 410-3165 Voice
(817) 410-3012 Fax
BUILDING --- RESIDENTIAL ALTERATION
Issue Date: September 3, 2020
PROJECT DESCRIPTION: Foundation Repair - Install (8) Pilings
PROJECT #
SFRA-20-3125
(817) 410-3010
Inspections
www.mygov.us
Permits
LOCATION LEGAL
1834 Meadow Crest Dr.
Grapevine, TX 76051
Parkwood Addition Blk 7 Lot 3
CONTRACTOR
Structured Foundation Repairs, Inc.
13301 Trinity Blvd. #133
Euless, TX 76040
(972) 484-1200 Phone
(972) 484-1215 Fax
OWNER
Jonathan D White
340 E 64th St #2a
New York, NY 10065-7060
AVAILABLE INSPECTIONS
Building Final (required)
INFORMATION
**APPLICANT NAME Kevin Karlin
**APPLICANT PHONE NUMBER 972-484-1200
County Tarrant
Fire Sprinkler System?N/A
Square Footage 1678
VALUATION 4190
FEES TOTAL =$ 150.00
Building Permit Fee, ($150.00 Flat Fee) Simple
Alteration $ 150.00
PAYMENTS TOTAL = $ 150.00
Structured Foundation Repairs, Inc. (Thomas
Kidd)
Other on 09/03/2020
Note: CC2789
($150.00)
NOTICES
1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING
CODE.
2) A copy of the signed permit and approved plans must be on site at all times.
3) The project address must be clearly posted at the job site.
READ AND SIGN
I hereby certify that the foregoing is correct to the best of my knowledge and all
work will be performed according to the documents approved by the Building
Department and in compliance with the City of Grapevine Ordinance regulating
construction. It is understood that the issuance of this permit does not grant or
authorize any violation of any code or ordinance of the City of Grapevine. I
FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE
NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND
THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR
OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR
FEDERAL AGENCY(S).
Signature Date
MYGOV.US City of Grapevine | BUILDING --- RESIDENTIAL ALTERATION | SFRA-20-3125 | Printed 07/27/21 at 12:49 p.m. Page 1 of 2
1902 Forest Glen LN
Weatherford, Texas 76087
817-948-4004
Final Evaluation Report for Foundation Repair
Date: September 15, 2020
Attention: Structured Foundation Repair (The Client)
Subject: Foundation Review
1834 Meadow Crest Dr., Grapevine, Texas
Authorization and Scope:
Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform an evaluation of
the slab on grade foundation for a 1 story residential home located at the subject address in conjunction
with foundation repairs performed by the foundation repair Contractor. This report serves as confirmation
that repairs have been done, provides information on the post-lift condition of the foundation, and
provides our reasonable professional opinion on the repair measures taken to improve the foundation
performance.
This report does not take into consideration any changes to the condition of the foundation or the
surrounding soils after the date the evaluation was performed.
Foundation Repair Details:
The Contractor installed concrete piers to which the purpose of the installed piers is to improve the
performance of the foundation by providing support at the piered locations in an effort to achieve relative
levelness of the slab. The repairs performed conform to the 2015 version of the International
Residential Code. It is understood that absolute levelness may not be achievable after repairs.
Data and Observations:
NEC performed a visual examination of the foundation for the subject property on 9/15/2020. NEC also
performed a floor survey using a Zip-level Pro-2000 series, collecting relative floor elevations, to aid in
surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring
encountered to reflect a consistent measuring plane. The map of the post-lift floor elevations can be seen
in the figure attached to this report.
Based on the data gathered and our professional engineering opinion, the repairs performed by the
Contractor have improved the foundation to be within slope tolerances generally accepted as industry
standards.
1902 Forest Glen LN
Weatherford, Texas 76087
817-948-4004
General Recommendations:
It is recommended that a guttering system be installed if the house does not have gutters. Installing a
guttering system will direct water way from the foundation and reduce the potential for ground erosion
near the foundation footing.
It is also recommended that the grading around the perimeter of the building be maintained as sloping
away from the foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such
grading configuration should prevent localized water from accumulating around areas of the foundation.
Saturated soils decline in bearing capacity and can result in differential settlement of the foundation.
Additionally, It is also recommended that the soil be graded such that the bottom portion of the foundation
is below grade, as per the governing code, and a watering system be utilized around the perimeter of the
house. Fluctuations in moisture content of the soils near the foundation of the house can cause differential
settlement. If the moisture content is kept consistent, the potential for differential movement is mitigated.
It is also recommended that the plumbing systems be checked if any repairs are performed on the
foundation system. Vertical movement of the foundation system can impose stresses on the plumbing
infrastructure and cause leaks.
Limitations:
This report is intended for information purposes only, and the sole use of the client and/or homeowner.
The scope of this report is limited to the items related to the foundation system only, and it is understood
that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of
the work provided does not include judgment on any of the superstructure, detached buildings, retaining
or privacy walls, concrete reinforcement, and/or site drainage. In addition, material and soil sampling/
testing, procedures were not performed. The report is not to be used by others for any purpose without
our written consent. Compliance with any code or specification other than as expressly noted in this
report is specifically excluded. It is the responsibility of the Contractor to adhere to any other applicable
codes or specifications.
No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject
property are offered by this report, nor does this report imply any liability to NEC, nor Daneel Nortier, PE
for any work to be performed as a result of this report. It is understood that soils in this area experience
movement due to moisture fluctuations. Such soil movement could cause the foundation to move after the
recommended repairs have been made. Any provided floor elevation data and recommended actions (if
any) are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or
imply that other problems may not occur in the future. No warranty, expressed or implied, is made or
intended and the limit of liability shall be limited to the fee paid for this report at the time of evaluation.
Report Prepared by,
Nortier Engineering Consultants LLC
Texas Engineering Firm (F-16800)
9/15/2020
Daneel Nortier, P.E.
Professional Engineer
(TX #113157)
1
1
1902 Forest Glen LN
Weatherford, Texas 76087
817-948-4004
info@nortierllc.com
Final Evaluation Report for Foundation Repair
Date: September 15, 2020
Attention: Structured Foundation Repair (The Client)
Subject: Foundation Review
1834 Meadow Crest Dr., Grapevine, Texas
Authorization and Scope:
Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform an evaluation of
the slab on grade foundation for a 1 story residential home located at the subject address in conjunction
with foundation repairs performed by the foundation repair Contractor. This report serves as confirmation
that repairs have been done, provides information on the post-lift condition of the foundation, and
provides our reasonable professional opinion on the repair measures taken to improve the foundation
performance.
This report does not take into consideration any changes to the condition of the foundation or the
surrounding soils after the date the evaluation was performed.
Foundation Repair Details:
The Contractor installed concrete piers to which the purpose of the installed piers is to improve the
performance of the foundation by providing support at the piered locations in an effort to achieve relative
levelness of the slab. The repairs performed conform to the 2015 version of the International
Residential Code. It is understood that absolute levelness may not be achievable after repairs.
Data and Observations:
NEC performed a visual examination of the foundation for the subject property on 9/15/2020. NEC also
performed a floor survey using a Zip-level Pro-2000 series, collecting relative floor elevations, to aid in
surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring
encountered to reflect a consistent measuring plane. The map of the post-lift floor elevations can be seen
in the figure attached to this report.
Based on the data gathered and our professional engineering opinion, the repairs performed by the
Contractor have improved the foundation to be within slope tolerances generally accepted as industry
standards.
1902 Forest Glen LN
Weatherford, Texas 76087
817-948-4004
info@nortierllc.com
General Recommendations:
It is recommended that a guttering system be installed if the house does not have gutters. Installing a
guttering system will direct water way from the foundation and reduce the potential for ground erosion
near the foundation footing.
It is also recommended that the grading around the perimeter of the building be maintained as sloping
away from the foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such
grading configuration should prevent localized water from accumulating around areas of the foundation.
Saturated soils decline in bearing capacity and can result in differential settlement of the foundation.
Additionally, It is also recommended that the soil be graded such that the bottom portion of the foundation
is below grade, as per the governing code, and a watering system be utilized around the perimeter of the
house. Fluctuations in moisture content of the soils near the foundation of the house can cause differential
settlement. If the moisture content is kept consistent, the potential for differential movement is mitigated.
It is also recommended that the plumbing systems be checked if any repairs are performed on the
foundation system. Vertical movement of the foundation system can impose stresses on the plumbing
infrastructure and cause leaks.
Limitations:
This report is intended for information purposes only, and the sole use of the client and/or homeowner.
The scope of this report is limited to the items related to the foundation system only, and it is understood
that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of
the work provided does not include judgment on any of the superstructure, detached buildings, retaining
or privacy walls, concrete reinforcement, and/or site drainage. In addition, material and soil sampling/
testing, procedures were not performed. The report is not to be used by others for any purpose without
our written consent. Compliance with any code or specification other than as expressly noted in this
report is specifically excluded. It is the responsibility of the Contractor to adhere to any other applicable
codes or specifications.
No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject
property are offered by this report, nor does this report imply any liability to NEC, nor Daneel Nortier, PE
for any work to be performed as a result of this report. It is understood that soils in this area experience
movement due to moisture fluctuations. Such soil movement could cause the foundation to move after the
recommended repairs have been made. Any provided floor elevation data and recommended actions (if
any) are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or
imply that other problems may not occur in the future. No warranty, expressed or implied, is made or
intended and the limit of liability shall be limited to the fee paid for this report at the time of evaluation.
Report Prepared by,
Nortier Engineering Consultants LLC
Texas Engineering Firm (F-16800)
9/15/2020
Daneel Nortier, P.E.
Professional Engineer
(TX #113157)
1
1