Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SFRA2019-4868 (2)
DEC 1 3 2019 eaoceleA mr, * DATE OF ISSUANCE: '�A r 0 8 2020 EE, (y "T E t .f s PERMIT #: �� gdco0e BUILDING PERMIT APPLICATION (PLEASE PRINT LEGIBLY— COMPLETE ENTIRE FORM) JOB ADDRESS: 1903 Lake Forest Rd, Grapevine, TX 76051 SUITE # 4 LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR (company name): Testa Energy CURRENT MAILING ADDRESS: 10430 Shady Trail #108 CITY/STATE/ZIP: Dallas, TX 75220 PH: # 518-407-9400 Fax # PROPERTY OWNER: Tom Geppert CURRENT MAILING ADDRESS: 1903 Lake Forest Rd CITY/STATE/ZIP: Grapevine, TX 76051 PHONE NUMBER: (972) 393-3893 PROJECT VALUE: $ 34981.20 FIRE SPRINKLERED? YES NO WHAT TRADES WILL BE NEEDED? (check ones that apply) ELECTRIC X PLUMBING MECHANICAL _ DESCRIPTION OF WORK TO BE DONE: Install Roof Mounted PV Solar System USE OF BUILDING OR STRUCTURE: Residential f NAME OF BUSINESS: Tesla Energy Total Square Footage under roof: Square Footage of alteration/addition: 540 ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROV L FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Alyssa Pedvin SIGNATURE PHONE #: 518-407-9400 EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ Setbacks Approval to Issue j Occupancy Group: Fire Sprinkler: YES NO Front: Electrical *;;-O"--1 C Division: Building Depth: Left: Plumbing Zoning: Building Width: Rear: Mechanical Occupancy Load: Plan Review Approval: Date: Site Plan Approval: Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P.O. BOX 95104, GRAPEVINE, TX 76099 (617) 410-3165 Right: IroZ�.2,c Building Permit Fee: $� Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: _ Total Amount Due: O:FORMSIDSPERMITAPPLICATIONS 1/02- ,2/07,11109.4111 L1 1 X) Project: Roof Mounted PV installation + ESS June 4, 2020 Mr. Tom Geppert 1903 Lake Forest Rd Grapevine, TX 76051 PERMIT#: Building: SFRA-19-4868 Electrical: EMISC-19-4869 NOTICE OF CANCELLATION City of Grapevine, This letter certifies our proposal to install a roof mounted PV solar system and energy storage system at 1903 Lake Forest Rd will move into a cancellation status. At this time, the homeowner and Tesla Energy will no longer move forward with the proposed installation due to customer cancellation. We would greatly appreciate reimbursement for the application fees paid. Please see below • Building / Electrical - $187 Please issue any applicable refund to: Tesla Energy - 10430 Shady Trail #108 Dallas, TX 75220 Please let me know if you have any questions or concerns. Regards, Im Alyssa Pedvin Permit Coordinator II 10430 Shady Trail #108 Dallas, TX 75220 T: (518) 407-9400 T = 5 L R Tesla, Inc. 10430 Shady Trail #108, Dallas, TX 75220 p +518.407.9400 f +214.352.8904 GRA UE `'T F:• A IV �' City of Grapevine P.O. Box 95104 Grapevine, TX 76099 (817) 410-3165 Voice (817)410-3012 Fax CONTRACTOR BUILDING --- RESIDENTIAL ALTERATION Issue Date: January 6, 2020 PROJECT DESCRIPTION: Install Residential Solar Panels With Electrical PROJECT # (817) 410-3010 WWW.mygov.us SFRA-19-4868 Inspections Permits LOCATION LEGAL 1903 Lake Forest Rd. Lake Forest Addition Lot 8 Grapevine, TX 76051 Lake Forest Addition Lot 8 Tesla Energy Operations, Inc. (BLDG) 10430 Shady Trail Dallas, TX 75220 (518)407-9400 Phone (214)352-8904 Fax (214) 724-6768 Mobile apedvin@tesla. Thomas D Geppert 1903 Lake Forest Rd Grapevine, TX 76051 AVAILABLE INSPECTIONS ► Building Final (required) INFORMATION —APPLICANT NAME Alyssa Pedvin —APPLICANT PHONE NUMBER 518-407-9400 County Tarrant Fire Sprinkler System? NO Square Footage 540 VALUATION 34982 FEES TOTAL = $ 150.00 Building Permit Fee, ($150.00 Flat Fee) Simple $ 150.00 Alteration PAYMENTS TOTAL = $ 150.00 Tesla Energy Operations, Inc. (BLDG) (Wesley Davis) Other on 0110612020 ($150.00) Note: CC4727 NOTICES 1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) A copy of the signed permit and approved plans must be on site at all times. 3) The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL APENCY(S). ,ignature Date MYGOV.US City of Grapevine I BUILDING --- RESIDENTIAL ALTERATION I SFRA-19-4868 I Printed 01/06/20 at 10:21 a.m. Page 1 of 2 DEC 13 2010 A WINE Ime Date: z ` rCITY OF GRAPEVINEile (CIRCLE ONE) - MECHANICAL ELECTRICAL - PLUMBING - IRRIGATION - FUEL GAS PERMIT APPLICATION .PLEASE PRINT LEGIBLY— COMPLETE ENTIRE FORM) PERMIT # BLDG. PERMIT # DATE: JOB ADDRESS: 1903 Lake Forest Rd, Grapevine, TX 76051 DESCRIPTION OF WORK: Install Roof Mounted PV Solar System PROPERTY OWNER: CONTRACTING COMPANY' I Tom Geppert Tesla Energy ADDRESS: ADDRESS: 1903 Lake Forest Rd 10430 Shady Trail #108 CITYISTATEIZIP: CITY/STATE/ZIP: Grapevine, TX 76051 Dallas, TX 75220 PHONE NUMBER: PHONE NUMBER: (972) 393-3893 518-407-9400 TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES (SO FT) EACH TRADE I. R-3 1 - 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200 - 1,500 $ 63.18 NEW CONSTRUCTION & 1,501 - 1,750 $ 76.48 ADDITIONS (PER UNIT) 1,751 - 2,000 $ 83.13 2,001 - 2,250 $ 89.78 TOTAL SQ. FOOT UNDER 2,251 - 3,000 $ 96.43 ROOF 3,001 - 3,500 $ 103.08 3,501 - 4,000 $ 109.73 4,001 + $ 120.37 EACH TRADE II. A, E, I, R-1 1 - 500 $ 37.00 HOTELS, APARTMENTS, 501 - 100,000 $ 17.50+.035 PER DRINKING/DINING, 100,001 - 500,000 $ 3,500.00+.03 SQUARE EDUCATIONAL, ASSEMBLY, 500,001 + $15,000.00+.02 1 FOOT INSTITUTIONAL EACH TRADE III. B, F, H, M, S, U OFFICE, RETAIL, WHOLESALE, 1 - 500 $ 37.00 GARAGES, FACTORIES, 501- 50,000 $ 32.00+ .01 PER WORKSHOPS, SERVICE 50,001- 100,000 $ 182.00+ .007 SQUARE STATIONS, WAREHOUSE 100,001+ $ 582.00+ .003 FOOT CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH -OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+ .009 50,001- 100,000 $ 127.00+ .007 PER $ 1,500 100,001- 500,000 $ 327.00+ .005 DOLLAR TVALUATI 500,001+ $ 1,327.00+ .003 ON EACH TRADE . ISCELLANEOUS iftR1,3A SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 SUITE # AMOUNT DUE C:1Userslsbatt"ppDatelLocel\Microsoft\Windows\Temporary Internet FileslContent.OuUook1G80E6GQFIMEP APPLICATION 4-11.doc PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM) ............................................... $42.00/HOUR* • REINSPECTION FEES.................................................................................................................. $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED........................................................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO APPROVEDPLANS.......................................................................................................................$42.00/HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS — I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND 1 OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. Alyssa Pedvin SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT PRINTED NAME (OR HOMEOWNER FOR HOMEOWNERS PERMITS) PHONE #: 518-407-9400 EMAIL: *OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. —ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. Development Services Department, Building Inspections The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3165 Fax (817) 410-3012 * www.grapevinctexas.gov C:1Userslsbake\AppDatalLocallMicrosoft\Windows\Temporary Internet Files\Content.Outlook1G80E6GQFIMEP APPLICATION 4-11.doc ELECTRICAL PERMIT - MISC ��.�r Yf l� Issue Date: January 6, 2020 ` 7 F • 1 4 5'd PROJECT DESCRIPTION: Electrical For Residential Solar Panel Install 7'.. 1'*T PROJECT # (817) 410-3010 WWW.mygov.us �y EMISC-19-4869 Inspections Permits City of Grapevine LOCATION LEGAL P.O. Box 95104 Grapevine, TX 76099 1903 Lake Forest Rd. Lake Forest Addition Lot 8 Grapevine, TX 76051 Lake Forest Addition Lot 8 (817) 410-3165 Voice (817) 410-3012 Fax CONTRACTOR INFORMATION Tesla Energy Operations, Inc. (ELEC) County Tarrant State ID # 276008 Square Footage 540 10430 Shady Trail VALUATION 1500 Dallas, TX 75020-0000 (518) 407-9400 Phone FEES TOTAL = $ 37.00 (214) 352-8904 Fax Electrical Miscellaneous Fee $ 37.00 (518) 407-9400 Mobile PAYMENTS TOTAL = $ 37.00 OWNER Tesla Energy Operations, Inc. (ELEC) (Wesley Thomas D Geppert Davis) ($37.00) Other on 0110612020 1903 Lake Forest Rd Note: CC4727 Grapevine, TX 76051 NOTICES AVAILABLE INSPECTIONS ALL work must be done in compliance with the 2005 NATIONAL ELECTRIC D. Electrical Final (required) CODE. PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND I OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. MYGOV.US City of Grapevine I E&CTRICAL PERMIT - MISC I EMISC-19-4869 I Printed 01/06120 at 10:23 a.m. Page 1 of 3 Lawrence Gray From: Lawrence Gray Sent: Monday, December 16, 2019 7:48 AM To: Cc: Don Dixson Subject: 19-4868; 1903 Lake Forest Rd., Grapevine, TX (PV Solar) Applicant: I have completed my review of the permit application referenced in the subject of this email. Please provide the following: Size all conductors per 2005 NEC on line diagram Label all conductor sizes. Provide signed and sealed site specific structural analysis for additional imposed loads. Feel free to contact me should you require any additional information. Thank you, Larry Gray Plans Examiner/Inspector City of Grapevine, TX (817)410-3163 TSBPE License # 1-3200 Version #80.5 -1 NAS December 18, 2019 RE: Project/Job # JB-7604154-00 Project Address: AHJ SC Office Design Criteria: CERTIFICATION LETTER Geppert Residence 1903 Lake Forest Rd Grapevine, TX 76051 Grapevine Dallas -Applicable Codes = Structure: 2015 IEBC; PV: 2015 IBC, ASCE 7-10, and 2015 NDS - Risk Category = II - Wind Speed = 115 mph, Exposure Category C, Partially/Fully Enclosed Method - Ground Snow Load = 5 psf - MP1: Roof DL = 9 psf, Roof LUSL = 19 psf (Non-PV), Roof LUSL = 2.8 psf (PV) - MP2: Roof DL = 9 psf, Roof LUSL = 12 psf (Non-PV), Roof LUSL = 1.5 psf (PV) - MP3: Roof DL = 9 psf, Roof LUSL = 12 psf (Non-PV), Roof LUSL = 1.5 psf (PV) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.097 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/does submitted for approval. Installer shall verify existing roof framing is in suitable condition and does not exhibit any signs of structural damage which may diminish the capacity of its members or connections prior to commencement of PV installation. This inspection is required because the home was not entered and the attic structure was not reviewed prior to the structural evaluation performed for this report. OFFICE COPY Digitally signed Ch HS by Chris H Kim Date: H Ki M 2019.12.20 23:12:29-05'00' T S 5Ln OF r4f NM. ti I F r 1 CHRIS H. KIM ..........................., oe 122720 JF CITY OF GRAPEVINE f OF: t C DOES NOT AUTHORIZE ANY WORK IN THE BUILDING CODE OR ZONING ORDINANCE. APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: c _ BY: '-w'Zl e- BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WTAV., Inc. ALL CHANGES MUST BE APPROVED Version #80.5 -1 NAS HARDWARE DESIGN AND STRUCTURAL EVALUATION RESULTS SUMMARY TABLES Landscape Hardware - Landscape Modules' Standoff Specifications Hardware X-X Spacing X-X Can?never Y-Y Spacing Y-Y Cantilever Conhquratlon Uplift DCR MP1 72" 24" 39" NA Not -Staggered 40.9% MP2 72" 24" 39" NA Not -Staggered 46.3% MP3 72" 24" 39" NA Not -Staggered 46.3% Portrait Hardware MP1 MP2 MP3 Mounting Plane MP1 MP2 MP3 T = 5 L n Hardware -Portrait Modules' Standoff Specifications X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR 48" 20" 66" NA Not -Staggered 46.0% 48" 20" 66" NA Not -Staggered 52.0% 48" 20" 66" NA Not -Staggered 52.0% Roof Pitch Qualification Results (Degrees) Member Evaluation Results 23° Member Impact Check OK 45° Member li;,;+,;.. Check OK 45' Member Imriact Check OK CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DUES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON, THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUQTION IN EASEMENTS OR PUBLIC RIGHT-OF-W*' Inc. ALL CHANGES MUST BE APPROVED ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET —BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPIIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE TYPE EC # 33536 MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Grapevine UTILITY: Oncor (MP2 Energy —Dallas) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. ELECTRICAL NOTES 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER —CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY —RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE 2015 IBC AND 2015 IRC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2005 NATIONAL ELECTRIC CODE. JOB NUMBER: JB-7604154 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (36) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 INVERTER: SOLAREDGE # SE1000OH—USOOOSNU2 JURISDICTION NOTES VICINITY C USTOWIC R DESCRIP-nih torn geppert 11.34 KW PV ARRAY 1903 Lake Forest Rd 40.5 KWH ENERGY STORAGE SYSTEM Grapevine, TX 76051 PAGE NAME: 9723933893 COVER SHEET ALL CHANGES REQUIRE APPROVAL OF REVISED PLANS APPROVED PLANS SHALL BE KEPT ON JOBSITE AT ALL TIMES CONTRACTOR SHALL CALL FOR INSPECTIONS: (317) 410-3010 CONTRACTOR REGISTRATION WILL BE REVOKED UPON PERMIT EXPIRATION. SEPARATE PLUMBING, MECHANICAL, ELECTRICAL AND SIGN PERMITS SHALL BE REQUIRED SITE PLAUv, STRUCTU VIEWS OF: IIZE ANY WORK N OR ZONING ORD NANCE. APPROVED PLANS TO BE KEP OIL THE JOB SITE AT ALL TIMES DATE: Irt., 2.o BY: - -a-9s� — _ 1ALU%_ _ INSPECTION DIVISION: REMEL1WSE)WES W TO CONSTRUCTIOI 1 IN REV NAOjA SWEP- awl bkeUbLlk_ HIL-A f I i.ir-WR i . * ML CB- AN DIES MUST tit AVVKUV =D DNGN: Jonathan Chavez SHEET: REV: DATE: 1 12/11/2019 T=SLn RESPONSE Tn r%01V _ DEC 2 7 2019/9_�G�aSl I/ 19 mrv.wrr I I I 2 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B- 7 6 0 415 4 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing —Insert PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (36) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE1000OH—USOOOSNU2 -,IISTOMFP. tom geppert 1903 Lake Forest Rd Grapevine, TX 76051 9723933893 DFSUjiP T10114: 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME PROPERTY PLAN • CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: _ BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBI:_iC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED PROPERTY PLAN Scale:l" = 30'-0' 0 30' 60' F DESIGN: Jonathan Chavez T E 5 Lin SHEET: REV: DATE 2 12/11/2019 METER IS WITHIN 10 FEET FROM THE AC DISCONNECT THE VISIBLE LOCKABLE LABE DISCONNECT IS LOCATED WI1 FT. OF ONCOR METER THE VISIBLE LOCKABLE LABE DISCONNECT IS LOCATED WI1 ONCOR METER. .......... T�-i� F GJ .•�� .1r i CHRIS H. KIM 122720 Digitally si Chri S byChris H Date: m2019.12.2( H Ki 23:24:51 -( SITE PLAN Scale:1/16" = 1' 01' 16' 32' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J B-7604154 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing -Insert MODULES: (36) Hanwho Q-Cells # Q.Peak DUO BLK-G5/SC315 INVERTER: SOLAREDGE 9 SE10000H-USOOOSNU2 CUSTOMER: tom geppert 1903 Lake Forest Rd 1 Grapevine, TX 76051 19723933893 Of House PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:65 ARRAY AZIMUTH:65 MATERIAL: Comp Shingle STORY: 2 Stories e a PITCH:45 ARRAY PITCH:45 MP2 AZIMUTH:65 ARRAY AZIMUTH:65 e MATERIAL: Comp Shingle STORY: 2 Stories e Fa PITCH: 45 ARRAY PITCH:45 E3 _ _ MP3 AZIMUTH: 155 ARRAY AZIMUTH: 155 MATERIAL: Comp Shingle STORY: 2 Stories DESCRIPnm: 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME: SITE PLAN LEGEND 0 (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO "v & WARNING LABELS sv R© AUTOMATIC RELAY FDC DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS ENERGY STORAGE SYSTEM FOR STAND Ess ALONE OPERATION DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER RSD RAPID SHUTDOWN STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE dW gf6jal gl PeRE RED > #S89EFORCOUNSTRINMON SHE=ET: OF: - RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANC, . CITY APPROVED PLANS TO BE KEPT ON TWF: IfIR SrrF4T A I I TINARO,, DESIGN: br)&? Chavez BUILDING INSP -CTION 5VISONT RELEASE DOES NOT AP ILY-T-O CO . ;TRUC T,GN4T- SHEET: EBWEMENTS OR PI, BUC RIGHT-OF-WAY. ALL CHANWOV aST BE APPROVED (N) PV MODULE S1 (E) MOUNTING PLANE (MP) 0SV TYPICAL PV SIDE VIEW MS PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK (4) ZEP FLASHING INSERT (3) (E) COMP. SHINGLE (E) ROOF DECKING (2) 5/16" DIA STAINLESS LOWEST MODULE STEEL LAG SCREW (2-1/2" EMBED, MIN) (E) RAFTER (js CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. SUBSEQUENT MODULES STANDOFF Scale: 1 1/2" = 1' JOB NUMBER: J B-7 6 0415 4 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES (36) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 INVERTER: SOLAREDGE r SE10000H—USOOOSNU2 INSTALLATION ORDER I LOCATE RAFTER, MARK HOLE �(1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. �IINSTALL LEVELING FOOT TOP (4)I OF MOUNTING BLOCKON & ---I SECURELY FASTEN WITH BOLT. CUSTOYER: tom geppert 1903 Lake Forest Rd Grapevine, TX 76051 9723933893 �CHRIS H. KIM�• 122720 4/��-����1: V E' ,' RIP s10N 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME: STRUCTURAL VIEWS CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED DLxK,N Jonathan Chavez SHEET: REV: DATE: 4 12/11/2019 T=SLn CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART To OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J B-7604154 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (36) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 INVERTER: SOLAREDGE 4 SE1000OH—USOOOSNU2 [.liSi:AAEF torn geppert 1903 Lake Forest Rd Grapevine, TX 76051 9723933893 Design Code ASCE-7 10 Importance Factor I 1 Ultimate Wind Speed V—Ult 0 Fig. 1609A Exposure Category C Section 26.7 Ground Snow Load pg 5 Table 7-1 Jobsite Specific Design Cdterio MP Specific Design Information MP Name MP3 MP2 Of Roofing Comp Shingle Comp Shingle Camp Shingle Standoff ZS Camp V4 w ZS Comp V4 w ZS Comp V4 w Flashing —Insert Flashing —Insert Flashing —insert Pitch 45 45 23 SL/RLL: PV 1.4 psi 1.4 psf 2.7 psf SL/RLL: Non—PV 12.0 psf 12.0 psf 19.0 psf Standoff Spacing and Layout MP Name Landscape X—Spacing Landscape X—Cantilever Landscape Y—Spccitg Landscape Y—Cantilever Portrait X—Spacing Portrait X—Cantilever Portrait Y—Spacing Portrait Y—Cantilever Layout MP3 MP2 MP1 727 72' 72' 24' 24' 24' 39' 39' 39' 46' 46' 4r 20' 20' 2Cr 66' 66' 66' Not Staggered Not Staggered Not Staggered X and Y are maximums that are always relative to the structure training that supports the PV. X is across rafters and Y Is along rafters. DESCRIPTION: 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME: UPLIFT CALCULATIONS CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANC_. CITY APPROVED PLANS TO BE KEPT OI\ THE JOB SITE AT ALL TIMES DESIM JEIAtjrL;N Chavez _ BUILDING INSF EC NWVl RELEASE DOES NOT AP 1)LTO CONSTRUCTION IN SHEET EASE NTS OR P IBLIC RIGHT-OF-WAY. ALL -CH F K UST BE APPROVED GROUND SPECS BOND (N) #8 GEC TO (N) GROUND ROD AT PANEL WITH IRREVERSIBLE CRIMP MAIN PANEL SPECS Panel Number: No label Meter Number:144 081 088 Underground Service Entrance E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER AC DISCONNECT (E) WIRING 7 200A N I I I I I I I I I J- TO 120/MOV SINGLE PHASE UTILITY SERVICE Utility meter GENERAL NOTES INVERTER SPECS Inv 1: DC 'Ungrounded INV 1 - (1) SOLAREDGE # SEI0DOOH-USODOSNU2 Inverter, 10DOOW,240V/208V,987;111) Wave w/Unifed Disco and ZB,AFCI INV 2 INV 3 (N) 200A LOAD CENTER AUTOMATIC RELAY AC DISCONNECT 8} I` W i6; X 1vU� 2r J 150A 60A 2P L1 s ■ __ �-J L2 ♦ N N � _ L"J r------- - - - - -- EGC!GEC L2 L1 I 30Al2P I 3 L1 �aq G L2 V 200A 2P e- (E) LOADS (E) 200A DISTRIBUTION PANEL MODULE SPECS LICENSE - (36) Hanwha 0-Cells # Q.Peak DUO BLK-G5/SC315 CA # 888104 PV Module; 315W,292.2PTC, 4OMM, Black Frame, MC4, ZEP, 1000V C-46, C-10 Voc: 40.29 Vpmax: 33.46 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER SolarCity Inverter 1 SOLAREDGE - DC+ SE1000OH-USOOOSNU2 _ DC. MP1,MP2:1x13 EGC r---- - - - - -- 3 ����]]---- - - - - -- --� ---♦ ---- - z-- --- zaov I 4 DC+ - rf DC+ I Dc- _ f Da MP3:1x11 , DC+ 1 f DC+ - MP2,MP3: 1x12 - - ---� 1 DC -- GND --- EGC--- - - - - -- - --�------ ----EGC ------------ ---J (1) Conduit Kit; 3/4" EMT _♦ c N ENERGY STORAGE SYSTEM 30A,2 L1 L2 N V ENERGY STORAGE SYSTEM lac 3vA1,2 L, - ` - LN ENERGY STORAGE SYSTEM I L------- EGC THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED WITHIN 10 FT. OF ONCOR METER 7 - (1)Eaton # DH224NRK Heavy Duty Disconnect, 200A, 24OVoc, Fusible, NEMA 3R, 2P, 3W, for Class J fw., o �(1)AWG 1; AWG #6, THNM-2, Black (1)AWG #6, THNM-2, Red w H� -(2)Bussmonn # LPJ-200SP Class J fuse, 200A, 60DVac, must be installed in Heavy Duty disconnect #10, THWN-2, White _ 1 AWG THWN-2, Green NEUTRAL Vmp =240 VAC Imp=42 AAC EGC GEC - 1 Conduit Kit; 3 4 EMT - (1)Tesla 1118431-00-L BACK-UP GATEWAY; for ACPW2.0, ASY, NA with 3G w/ Antenna, PW20, 1akA SCi 7 (1 AWG #10, THWN-2, Black (1)AWG #10, THWN-2, Red W - 1 Siemens N EQ8695/MBK2o0� - (1)CUTLER-HAMMEJ2 # BR260 ( ) B tt Breaker, 60A 2P, 2 Spaces Circuit reaker M K 200A 2P, 22kAIC (1)AWG #10, THWN-2, White -' - (1) EATON RP20L2OO LOAD CENTER;20OA120/24OV,NEMA1,20SPACE40CIRCUIT,ML0,1E - (1) AWG #1 o, Ttl"72, Green (1)AWG #1/0, �THWN-2, Black - (11 Conduit Kit; 2" PVC Sch.. 80 -(1)AWG AE1%0, TFIINN-2, WHITE Cu, iranded,Commercial -(3)CUTLER-HAMM�R # BR230 Breaker, 30A 2P, 2 Spaces ®�(1)AWG/O, THWN-2, RED cu. tranded,Commercial U - (1)Gutter BOZ Metal; 4 x4"x4' , Box w/ cover, Nema 3R (3)2SLAAC3POWIERWALL 2.0; Home Energy Storoge,13.5KWH. Stackable, 5.8kVA, 88F TESLA (1 AWG 12/0. THWN-2, Black (1)AWG 12/0, THWN-2, Black ( AWG #2/0, THWN-2, Black V X - (1) CUTLER -HAMMER # DG224NRK Disconnect; 200 24OVac, Fusible, NEMA 3R - (1)AN #6,, TH,WN72, Green - (1)CUTLER -�IAMMER DG20ONK Groun i eutral it; 2DOA General, Heavy Duty (DG, DH), NEMA 1, 3R -(2, FFuse; 150A,�25OV, Gass RK5 -(I )U RRHAMMEFuse Rt# DS46FK CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J B-7604154 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing -Insert MODULE& (36) Hanwha Q-Cells # Q.Peak DUO BLK-G5/SC315 INVERTER: SOLAREDGE SE1000OH-USOOOSNU2 (1). Conduit, Kit;, 2", M. Sch..80. ....... (1)Conduit. Kit;. 2 PVC, Sch., 80 CUSTOMER: tom geppert 1903 Lake Forest Rd Grapevine, TX 76051 9723933893 IT(1) 2 ] AWG #10, PV Wire, 6DDV, Black AWG #10, Solid Bare Copper EGC Voc* = 500 Vmp = 350 VDC VDC Isc = 15 Imp=11.55 ADC ADC 2 OL-J (2) AWG #10, PV wre, 6DDV, Black (1) AWG #10, Solid Bare Copper EGC Voc* = 500 Vmp = 350 VDC VDC .... Isc = 15 Imp= 9.77 ADC ADC O(1)AWG (2)AWG #10, PV Wire, 60OV, Black #10, Solid Bare Copper EGC Voc 500 Vmp = 350 VDC VDC Isc -15 Imp= 10.66 ADC ADC ® (1) AWG #8, THWN-2, Black (1)AWG #8, THWN-2, Red Voc 500 Vmp = 350 VDC VDC Isc - 30 Imp= 20.43 ADC ADC O (1)AWG #10, TtIHN/THM7- ,.Gr"n. EGC.7(1)Co9duit, Kit;.3/4' EMT (1) AWG 110, THWN-2, Black Voc* 500 VDC Isc = 15 (1) AWG #10, THWN-2, Red Vmp = 350 VDC Imp=11.55 ADC ADC (1) AWG #10, THHN/THWN72, . Green, EGC.- (1) Condut. Kit,. 3/47 .EMT.. , , , , , DESCRiFTION 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME THREE LINE DIAGRAM A`, (1) SUNFr SY GROUND DINBI ckNCnON BOX DC P V) SPowRerDBoxEpiPmeroW ZEP CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDf CITY APPROVED PLANS TO BE KEPT O THE JOB SITE AT ALL TIMES DESWA I r-_ Jonathan ChovWJILDING IN RELEASE DOES NOT . EASEMENTS OR MEET: AU CHANGES 6 12/11/2019 of. RIGHT-OF-WAY. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 1903 Lake Forest Rd INVERTER AND DC DISCONNECT AC DISCONNECT AC DISCONNECT UTILITY SERVICE ----------------------- - SOLAR PHOTOVOLTAIC ARRAYS) L--------------------- - J ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER J g-7604154 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing —Insert MODULES: (36) Hanwha Q—Cells # Q.Peak DUO BLK—G5/SC315 INVERTER: SOLAREDGE # SE10000H—USOOOSNU2 JB-7604154-00 CUSTOMER: tom geppert 1903 Lake Forest Rd Grapevine, TX 76051 9723933893 T E ,CR!f T1PN 11.34 KW PV ARRAY 40.5 KWH ENERGY STORAGE SYSTEM PAGE NAME: SITE PLAN PLACARD CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED DESIGN: Jonathan Chavez SHEET: REV: DATE 7 12/11/2019 T=SLn Label Location: (C)(CB)(JB) Per Code: NEC 690.31.G.3 Label Location: (DC) (INV) Per Code: NEC 690.14.C.2 Label Location: (DC) (INV) Per Code: NEC 690.53 Label Location: (DC) (INV) Per Code: NEC 690.5(C) Label Location: (DC) (CB) Per Code: NEC 690.17(4) Label Location: (AC) (POI) Per Code: NEC 690.14.C.2 Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI ) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 690.17.4; NEC 690.54 Label Location: (POI) Per Code: NEC 690.64.B.4 Label Location: (D) (POI) Per Code: NEC 690.64.B.4 Label Location: (POI) Per Code: NEC 690.64.13.7 Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: _ OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection Label Set Label Location: (BLC) Per Code: NEC 408.4 Label Location: (BLC) Per Code: NEC 220 Label Location: (MP) Per Code: NEC 312.8(3) Label Location: (MP) Per Code: NEC 705.12.D.3 Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: Label Location: (MP) Per Code: NEC 705.12.D.3 Label Location: (MP) Per Code: NEC 705.12.D.2.3.c CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. _CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED (AC): AC Disconnect (BLC): Backup Load Center (MP): Main Panel Label Set 13 '45olarCity Z pSolar ZS Comp for composition shingle roofs Next -Level PV Mounting Technology C,aMPgr� °5- Description PV mounting solution for composition shingle roofs Fp Works with all Zep Compatible Modules �ontPa�� Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" V� LISTED Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev 0 Date last exported: April 29, 2016 11:22 AM r'SolarCity Components zepsolar.com 13 ZepSolar Mounting Block Part No. 850-1633 Listed to UL 2703 Next -Level PV Mounting Technology r Array Skirt Part No. 850-1608 or 500-0113 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to U L 2703 Listed to UL 467 and UL 2703 Captured Washer Lag Part No. 850-1631-001 850-1631-002 850-1631-003 850-1631-004 Leveling Foot Part No. 850-1397 Listed to UL 2703 End Cap Part No. (L) 850-1586 or 850-1460 (R) 850-1588 or 850-1467 DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end -user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document# 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM solar SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P300-ZEP, P400-ZEP Compatible with Zep Groove framed modules - Certified Zep Compatible"" bracket Mitigates all types of module mismatch losses, from - Attaches to module frame without screws - reduces on -roof manufacturing tolerance to partial shading labor and mounting costs - Flexible system design for maximum space utilization Power optimizer equipment grounded through the bracket - Next generation maintenance with module -level monitoring Up to 25% more energy Module -level voltage shutdown for installer and firefighter Superior efficiency (99.5%) safety USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK-ISRAEL-TURKEY-HUNGARY-BELGIUM-ROMANIA-BULGARIA www.solaredge.us solar=e" SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P400-ZEP P300-ZEP (for 60-cell PV modules) [ P400-ZEP(for7Z&96-cellmodules= INPUT Rated Input DC power)1) ............................................................................................................. 300 400 ........................ W ...... Absolute Maximum Input Voltage (Voc at lowest 48 80 Vdc temperature) ........................................................................................................................................... ............ M PPT Operating Range . .......8 ..48 ................ g-80......................... Vd C ..... ......................................................... Maximum Short Circuit Current (ISC) 10.1 1.9 ........................................................... . Adc .................................................................................................. Maximum DC Input Current ............................. . ....................1.2:5 ..............12:63 Adc ........... Maximum Efficiency 99•5 .................................................................................................................................................... Weighted Efficiency ........................................ 98.8 ................. ................................................................................. . %....... Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) T Maximum Output Current .......................................................................................................................................... 15 Adc Maximum Output Voltage 60 —_ Vdc - __ _ _ OUTPUT DURING STANDBY (POWER OPTIMIZER DISCO INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer _N_NECTED_FROM L 1 Vdc _ STANDARD COMPLIANCE— EMC C aasB, C61000-6-2, IEC61000-6-3 ... ................... ..FCP ........ .....rt15 ......Cl......s.....IE......................................... ... ...... .... ................................................................. Safe IEC62109-1(class II safety), UL1741 RoHS - -- -- - Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions including mounting bracket (WXLxFQ 128 x 196 x 27.5 / 5 x 7.71 x 1.08 128 x 196 x 35 / 5 x 7.71 x 1.37 mm / in ................................................................. Dimensions excluding mounting bracket (WxLxH} .................. .I ........ I ... I.............. 128 x 152 x 27.5 / 5 x 5.97 x 1.08 ............................................................. 128x152x35/ 5 x 5.97 x 1.37 mm / in ....................................................... Weight includingcables and mounting bracket) ............................................................................................................ 720 / 1:6 .................. 840 / 1:9 kg / Ib .................................................................. Input Connector ...........I ............. MC4 Compatible...................................... Output Connector Double Insulated; MC4 Compatible _. Output Wire Length 1.... 0:95 / 3.0.................. .............. 1:2 / 3.9 ....... I ..... I.... . ............. ........................................................ Operating Temperature Range ...................................................I............. ,40 - +85 / -40 - +185 ......................... __........................ -C /'F.... Protection Rating IP68 / NEMA 6P ............................................................................................... .............. ................................................................. lative Humidity Re......................... ..................................................................................... 0: 1.00....... ........ ........... ................. .... . .%........ lu Rated STC power of the module. Module of up to+5% power tolerance allowed. PV SYSTEM DESIGN USING A SINGLE PHASE THREE PHASE THREE PHASE _SOLAREDGE INVERTER(") HD -WAVE SINGLE PHASE 208V 480V Minimum String Length (Power Optimizers) 8 10 18 ............................................................................................... Maximum . . String . . Le .th (Power Optimizers) 25 25 50 5700 (600o with Maximum Power per String SE75250 6000 12750 W 600H-US) I ..... ............................................................................ .................................. Parallel Strings of Different Lengths or Yes ........ .. Orientations al For detailed string sizing Information refer to! http!//www.solaredge.com/sites/default/files/string_slzing_na.pdt. POWERWALL POWERWALL [� Backup Gateway Tesla Powerwall is a fully -integrated AC battery system for ,.r ca residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption, time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. e1 PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage (Nominal) 120/240 V Feed -In Type Split Phase Grid Frequency 60 Hz Total Energy' 14 kWh Usable Energy' 13.5 kWh Real Power, max continuous' 5 kW (charge and discharge) Real Power, peak (10s, off-grid/backup)' 7 kW (charge and discharge) Apparent Power, max continuous 5.8 <VA (charge and discharge) Apparent Power, peak (10s, off-grid/backup) 72 <VA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split -Phase Loads 100% Power Factor Output Range +/- 1.0 adjustable Power Factor Range (full -rated power) +/- 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency'' 90% Warranty 10 years 'Values provided for 250C (770F), 3.3 kW charge/discharge power 'In Backup mode, grid charge power is limited to 3.3 kW 3AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Dimensions' 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight' 114 kg (251.3 Ibs) Mounting options Floor or wall mount 'Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. 753 mm 147 mm (29.6 in) (5.75 in) r e; T Lt. Pi r I r . ,i �7 1150 mm (45.3 in) a . 3 i ENVIRONMENTAL SPECIFICATIONS Operating Temperature Recommended Temperature Operating Humidity (RH) Storage Conditions Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Maximum Elevation Emissions FCC Part 15 Class B, ICES 003 Environment Environmental RoHS Directive 2011/65/EU Enclosure Type Seismic AC156, IEEE 693-2005 (high) Ingress Rating Wet Location Rating Noise Level @ 1m -200C to 500C (-4°F to 122°F) 0°C to 30oC (32°F to 86°F) Up to 100%, condensing -20°C to 300C (-4°F to 86°F) Up to 95% RH, non -condensing State of Energy (SoE): 25% initial 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Yes < 40 dBA at 300C (86°F) The Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a circuit breaker, the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 230 V, 120/240 V Feed -In Type Single & Split Phase Grid Frequency 50 and 60 Hz Disconnect Current 200 A Maximum Input Short Circuit Current 10 kA Overcurrent Protection Device' 100-200 A; Service Entrance Rated Overvoltage Category Category IV AC Meter Revenue grade (+/-1 %) Connectivity Ethernet, Cellular (3G)2, Wi-F1 User Interface Tesla App Operating Modes Support for solar self -consumption, time -based control, and backup Backup Operation Automatic disconnect for seamless backup transition Modularity Supports up to 10 AC -coupled Powerwalls Warranty 10 years ' Circuit breaker required for installation at service entrance. 'Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, IEC 62109-1, CSA C22.2.107.1 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003, IEC 61000-6-3, EN 55024, EN 301489-1, EN 301489-7, EN 301489-17 Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation Seismic AC156, IEEE 693-2005 (high) MECHANICAL SPECIFICATIONS Dimensions 740 mm x 378 mm x 129 mm (29.1 in x 14.9 in x 5.1 in) Weight 16.4 kg (36 Ibs) Mounting options Wall mount 378 mm 129 mm (14.9 in) -(5.1 in) _I 740 mm (29.1 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature -20°C to 50°C (-4"F to 122'F) Operating Humidity (RH) Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type N EMA 3R Ingress Rating IP44 TESLA.COM/ENERGY T = 5 L n- TESLA.COM/ENERGY solar=e" SolarEdge Single Phase for North America SE3000H-US / SE380OH-US / SE5000H-U SE760OH-US / SE10000H-US / SE11400H- g J'D-e ..... w . a W W optimized installation with HD -Wave technology - Specifically designed to work with power optimizers Record -breaking efficiency Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors - Built-in module -level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Simple configuration and commissioning with smartphone app and built in Wi-Fi (SE10000H-US, SE1140OH-US) wave USA-CANAOA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN- www.solaredge.us SOUTH AFRICA-POLAND-CZECH REPUBLIC solar=@@Single Phase Inverters for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US �SE3000H USA SE3800H-US SE5000H-US ^ SE6000H US �SE7600H USTSEl0000H-USS 9E1140OH-US OUTPUT - _ _ _ _ _ - - - _ --- - Rated AC Power Output 3000 3800 @240V 5000 6000 7600 10000 11400 VA .......................................... I........3300,0n,208V.................................. ................ .....I........... . Max. AC Power Output 3000 3800 @240V 5000 6000 7600 10000 11400 VA AC Output Voltage Min.-Nom.- Vac Max; (183,-208„ 229)............... ................ AC Output Voltage Min.-Nom. J ✓ ✓ / J J Vac Max. (211 - 240. - 264). , , AC Frequency (Nominal) S9.3 - 6.67.60..5 Hz Maximum Continuous Output 16 24 - - A Current 208V........................ ................ Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current 240V........................ . GFDI Threshold Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds -- -- -:�. - - - - -- --- - - - -- - INPUT ---------- - _ � 0 - - - - -- - - Maximum DC Power 4650 5900 7750 9300 11800 15500 17670 W .................................. 1- .............�.............. �. L................................................ Transformer -less, Ungrounded Yes Maximum Input Voltage Nominal DC Input Voltage MaximuminputCurrent 208V 9 MaximuminputCurrent 240V ............. „ 10.5 Max. Input Short Circuit Current Reverse -Polarity Protection Ground -Fault Isolation Detection ......... ....................... Maximum Inverter Efficiency ,99.. CEC Weighted Efficiency ....... Nighttime Power Consumption FEATURES -ADDITIONAL Supported Communication Interfaces Revenue Grade Data, ANSI C12.20 Rapid Shutdown - NEC 2014 and 2017 690.12 _ STANDARD COMPLIANCE RS485, Ethernet, ZigBee (optional), Cellular (optional) ............ .... ................................ I ... I.... ....................... Optiona.IM ...................... Automatic Rapid Shutdown upon AC Grid Disconnect Safety 94741, UL1741 SA, UL1699B, CSA C22:2, Canadian AFCI according to T.I, L, .-07 Grid Connection Standards „IEEE1547, Ryle 21,. Rule 14 (HI) ...... ........ ...... ........ ......... ......... Emissions FCC Part15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG 3/4" minimum / 20-4 AWG R ...?ng?....................I......... DC Input Conduit Size / # of Strings .......................................... minimum / 1-2 strings 14.. AWG 3/4" minimum / 1-3 strings / ......... AWG Ran a �.......... 8 .... . 14-6 4WG ......................... 21.3 x 14.6 21.3 x 14.6 Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 450 x 370 x 174 x 7.7 / 540 x x 7.3 / 540 x in / mm (HxWxD) 370 x 195 370 x 185 ............................ Weight with Safety Switch ............................... ....... 2? .... 25.1 / 11.4 .... / 11.9 l::.::::::::::::I::::.::::::::'.:.::............. . . 38.8 / 17.6 40.1 / 18, 2 Ib / kg Noise < 25 ............ <50 d BA .............I........................ .............................................................. Natural convection and internal fan (user Cooling Natural Convection replaceable), Operating Temperature Range ................13 to +140 / 25 to +6014)(-40'F / -40'C option)f51 „'F / 'C Protection Rating .............. ........ „ NEMA.3R(InverterwlthSafet Switch) (1) For other regional settings please wntact SolarEdge support Ri Revenue grade inverter P/N: SE-H-USOOONNC2 141 For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-d.mting-note-na.pdf Isl A0 version P/N: SExxxxH-1.15000NNU4 The new Q.PEAK DUO LK G5/SC solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface, and a black Zep CompatibleTM frame design for improved aesthetics, easy installation and increased safety. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions - both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY G Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.3%. A INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCF Long-term yield security with Anti LID and Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. Inclusive 12-year product warranty and 25-year linear performance guarantee2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. THE IDEAL SOLUTION FOR: 13 Rooftop arrays on commercial / industrial buildings CELLS .. I :vr s•r.n •:❑r�. .. 2018 . .y QGM gPAp, H / �a �;A- P:w APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) 2 See data sheet on rear for further information. Engineered in Germany OCELLS SPECIFICATIONMECHANICAL Format 66.3in x 39.4 in x 1.57 in (including frame) (1685 mm x 1000mm x 40mm) Weight 44.5 lbs (20.2 kg) ''° ""^~''•^-' I Front Cover 0.13 in (3.2mm) thermally pre -stressed glass with anti -reflection technology -p , ^^ 1 Back Cover Composite film Frame Black anodized aluminum ° •v„ dooms Cell 6 x 20 monocrystalline Q.ANTUM solar half -cells )unction box 2.76-3.35in x 1.97-2.76in x 0.51-0.83in o w (70-85mm x 50-70mm x 13-21mm), decentralized, IP67 ^-^• Cable 4ri Solar cable; (+)>43.3in (1100mm), H- 43.3in (1100mm) Connector Multi -Contact MC4, IP68 ELECTRICAL CHARACTERISTICS POWER CLASS 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W /-OW) Power at MPPZ PMPP [WI 310 315 320 Short Circuit Current' Ise [A] 9.83 9.89 9.94 E Open Circuit Voltage' Vac IV] 40.02 40.29 40.56 e Current at MPP' Imp? [A] 9.36 9.41 9.47 Voltage at MPP' V.11 IV] 33.12 33.46 33.80 Efficiencyz n [0/01 a 18.4 a 18.7 >_ 19.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC' Power at MPP' P.P [W] 229.7 233.5 237.2 E Short Circuit Current' Ise [A] 7.93 7.97 8.02 E Open Circuit Voltage' V, (19 37.43 37.69 37.94 Current at MPP' INPP [A] 7.36 7.41 7.45 Voltage at MPP' vMPP IV] 31.20 31.52 31.84 11000W/m�, 25'C, spectrum AM 1.5G z Measurement tolerances STC x3%; NOC t 5 % 3800W/m2, NOCT, spectrum AM 1.5G *typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE YEARS At least 98%or nominal power during first year. , r-----�- Thereafter max. 0.54% degradation per year. i At least 93.1 % of nominal power up to 10 years. ---- At least 85 % of nominal power up to 25 years. m - - Alldatawnhinmeasurementtolerances. � --i ---- -----*----- Full warranties in accordance with the warranty 5 terms of the Q CELLS sales organization of your respective country. Be IRRADIANCE [W/m'I Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000W/m2). TEMPERATURE COEFFICIENTS Temperature Coefficient of Ise Temperature Coefficient of PM a [%/Kl +0.04 Y [%/Kl -0.37 Temperature Coefficient of Vae (3 Normal Operating Cell Temperature NOCT [%/Kl -0.28 171 113 t 5.4 (45 3:3 *C) PROPERTIESt DESIGN Maximum System Voltage Van IV] 1000 (IEC) / 1000 (UL) Safety Class Maximum Series Fuse Rating [A DCI 20 Fire Rating C (IEC) / TYPE 1 (UL) Design load, push MY [Ibs/ft'] 50 (2400 Pa) Permitted module temperature -40 *F up to +1857 on continuous duty (-40*C up to +85'C) Design load, pull (UL)2 [Ibs/1N] 50 (2400Pa) z see installation manual QUALIFICATIONS f CERTIFICATES PACKAGING INFORMATION UL 1703; CE-compliant; Number of Modules per Pallet 26 IEC 61215 (Ed. 2); IEC 61730 (Ed. 1), application class A Number of Pallets per 53' Trailer 32 �vE (♦� C N coNR�r�L. e Number of Pallets per 40' High Cube Container Pallet Dimensions (L x W x H) 26 69.3 in x 45.3 in x 46.9 in ` c �, us ^ '- m (1760mm x 1150mm x 1190mm) :wn cnnrrc ,i Pallet Weight 12681bs (575kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha O CELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us