Loading...
HomeMy WebLinkAboutSFRA2020-1676 G��ppAPE �Y INE� Tg�p� . DATE OF ISSUANCE:_Jj PERMIT #: —0 \ (_0 —1 1W BUILDING PERMIT APPLICATION (PLEASE PRINT LEGIBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: 3409 Lookout Court SUITE # LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR (company name): Structured Foundation Repairs Inc. CURRENT MAILING ADDRESS: 13301 Trinity Blvd. #133 CITY/STATE/ZH': Euless, TX 76040 PH: # 972-484-1200 Fax # 972-484-1215 PROPERTY OWNER: James Reed CURRENT MAILING ADDRESS: 3409 Lookout Ct CITY/STATE/ZIP: Grapevine TX 76051 PHONE NUMBER: (817) 821-0666 PROJECT VALUE: $14,690.00 FIRE SPRINKLERED? YES NO X WHAT TRADES WILL BE NEEDED? (Check ones that apply) ELECTRIC PLUMBING MECHANICAL DESCRIPTION OF WORK TO BE DONE: Install 9 pilings USE OF BUILDING OR STRUCTURE: Residence NAME OF BUSINESS: Total Square Footage under roof: 3963 Square Footage of alteration/addition: ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PLBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Kevin Karlin SIGNATURE PHONE #: 972-484-1200 EMAIL: permits@structuredfoundation. FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ Setbacks Approval to Issue Occupancy Group: Fire Sprinkler: YES NO _ Front: Electrical Division: Building Depth: Left: Plumbing Zoning: Building Width: Rear: Mechanical 1 Occupancy Load: 1 Plan Review Approval: Date: Site Plan Approval: v Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 Right: Building Permit Fee: Plan Review Fee: Lot Drainage Fee: Sewer Availability Rate: Water Availability Rate: Total Fees: Total Amount Due: ` a O:FORMSIDSPERMITAPPLICATIONS 1/02-Rev.11104,5106,i >x BUILDING --- RESIDENTIAL ALTERATION Issue Date: May 18, 2020 t $, PROJECT DESCRIPTION: Foundation Repair �� PROJECT # (817) 410-3010 www.mygov.us SFRA-20-1676 Inspections Permits City of Grapevine LOCATION LEGAL P.O. Box 95104 3409 Lookout Ct. Stonewood (Gpv) Bilk 6 Lot 6 Grapevine, TX 76099 Grapevine, TX 76051 (817) 410-3165 Voice (817) 410-3012 Fax CONTRACTOR INFORMATION Structured Foundation Repairs, Inc. —APPLICANT NAME Kevin Karlin 13301 Trinity Blvd. #133 —APPLICANT PHONE NUMBER 972-484-1200 Euless, TX 76040 County Tarrant (972) 484-1200 Phone Fire Sprinkler System? NO (972) 484-1215 Fax Square Footage 3963 VALUATION 14690 OWNER FEES TOTAL = $ 150.00 James Reed 3409 Lookout Ct Building Permit Fee, ($150.00 Flat Fee) Simple Grapevine, TX 76051 Alteration $ 150.00 AVAILABLE INSPECTIONS PAYMENTS TOTAL =$ 150.00 ► Building Final (required) Structured Foundation Repairs, Inc. (Thomas Kidd) ($150.00) Other on 0511512020 Note: CC9291 NOTICES 1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) A copy of the signed permit and approved plans must be on site at all times. 3) The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). Signature Date MYGOV.US City of Grapevine I BUILDING --- RESIDENTIAL ALTERATION I SFRA-20-1676 I Printed 05/18/20 at 2:17 p.m. Page 1 of 2 ALL CHANGES REQUIRE 1902 Forest Glen LN APP L Weatherford, Texas 76087 LANS' 817-948-4004 NL!y H ENGINEERING ONSULiANiS LLC n� '�' SHALL BE Initial ReDort for Foundation Assessment KEPT ON JOBSITE ATALL TIMESCONTRACTOR SHALL CALL FOR Date: May 11, 2020 INSPECTIONS: Attention: Structured Foundation Repair (The Client) (81 7) 410-3010 Subject: Foundation Review CONTRACTOR REGISTRATION 3409 Lookout Ct., Grapevine, Texas WILL BE REVOKED UPON Authorization and Scone: PERMIT EXPIRATION. Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform a review of the slab on grade foundation system of the 2 story residential home with brick veneer located at the subject address referenced above. This report provides guidance as to whether or not the existing foundation system is in need of repair. The report also proposes a recommended plan if repairs are needed. Conclusions/Specific Recommendation: NEC performed a visual examination of the foundation for the subject property on 5/11/2020. NEC also performed a floor survey using a Zip -level Pro-2000 series, collecting relative floor elevations, to aid in surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring encountered to reflect a consistent measuring plane. The map of the existing floor elevations can be seen in the figure attached to this report. Based on review of the foundation, and reasonable professional engineering opinion, we've determined that settlement of the foundation has occurred and should be repaired. Although complete levelness cannot be guaranteed, or may not be attainable, the proposed plan should improve the performance of the foundation. It is recommended that nine (9) piers and drainage improvements be installed as indicated on the figure(s) attached to this report. Locations of internal piers [if needed] are intended to be approximate. The Contractor should locate the beams and place internal piers accordingly. Furthermore, the proposed foundation repairs shall meet or exceed the 2015 International Residential Code (IRC) and any local applicable amendments to the IRC. This report is solely based on information gathered during our site visit on 5/11/2020, and does not take into consideration any changes in condition of the foundation or soils after the date which the information was gathered. Provide- S19nod and' Seaf ea letter from Registered engineer ccnflrming site inspection and approval pier instelletlon whets work Is complete, AY 14 202(1 CRY OF [3R6MINE RELEASED FOR CONSTR ION SHEET: I OF: 41 RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDNANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: �������o BY: � _ 7 BUI DING INSPECTION DIVISIOr+>-,-- RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED OFFICE COPY 3�E' L00 ko vt- O_O u t't- mot. 1902 Forest Glen LN Weatherford, Texas 76087 817-948-4004 NORTIER ENGINEERING CONSULTANTS RC General Recommendations: It is recommended that the soil be graded such that the bottom portion of the foundation is below grade, as per the governing code and a watering system be utilized around the perimeter of the house. Fluctuations in moisture content of the soils near the foundation of the house can cause differential settlement. If the moisture content is kept consistent, the potential for differential movement is mitigated. It is also recommended that the plumbing systems be checked after any repairs are made to the foundation system. Vertical movement of the foundation system can impose stresses on the plumbing infrastructure and cause leaks. Furthermore, grading around the perimeter of the building should be maintained as sloping away from the foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such grading configuration should prevent localized water accumulating around areas of the foundation. Saturated soils decline in bearing capacity and can result in differential settlement of the foundation. Limitations: This report is intended for information purposes only, and the sole use of the client and/or homeowner. The scope of this report is limited to the items related to the foundation system only, and it is understood that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of this report does not include judgment on any of the superstructure, detached buildings, retaining or privacy walls, concrete reinforcement, and/or site drainage. In addition, the scope of this report excludes material and soil sampling/testing, procedures and as such were not performed. The report is not to be used by others for any purpose without our written consent. Compliance with any code or specification other than as expressly noted in this report is specifically excluded. It is the responsibility of any Contractor to abide by any other applicable codes or specifications. No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject property are offered by this report, nor does this report imply any liability to NEC, nor Daneel Nortier, PE for any work to be performed as a result of this report. It is understood that soils in this area experience movement due to moisture fluctuations. Such soil movement could cause the foundation to move after the recommended repairs have been made. Any provided floor elevation data and recommended actions are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or imply that other problems may not occur in the future. No warranty, expressed or implied, is made or intended and the limit of liability shall be limited to the fee paid for this report at the time of evaluation. Report Prepared by, Nortier Engineering Consultants LLC o F Texas Engineering Firm (F-16800) It A; EEL dRTIER , • i 5/11/2020 Daneel Nortier, P.E. Professional Engineer (TX #113157) SHEET: V F: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED Pool and Pool and decking decking SP - /.4 0.7 FP / Conc. 0•8 1.6 2.1 3.4 3.7 SP Conc. 0.1 0.3 0.7 1.0 1.4 2.5 2.9 -0.5 0.0 Carport Zero 2.0 Conc. 1.2 i (� -0.8 -0.5 2.0 2.8 Photo$+pph Labe:(') O 7p ,, Z w' m n m 2 0.8 3.0 r,-- rirese'erack y -+ m c� 1.2 2� Driveway 1.7 _.S mpMartion = = m -0.6 -0.2 •DLL-K gei¢c-i Drai ,'D -a 0 -0.3 ZZmp �" O m0 co Entry I ' m4Zz Q m CC 20 0 � SP { 0.6 0.6 1.1 2.6 CD cc 0-0 M� G)a �a al f/l� ryiees rE: shown ir' es n n �� Zm p \ram m Ora `co, / - 0 Z �Q • •t • ORl / a Q Z i 11 15-/11120 3409 Lookout Ct By: DIN Grapevine, Texas NORIIER ENGINEERING CONSULTANTS LLC a M k 8 c ZOO cnzz 00� CU.0 m 0-4 �� z:C a z� 645 :��z D :<5 z Z NOTES: 1) Piles shall be driven to refusal 2) Contractor shall install double piers for shallow foundations (6ft or less), or where indicated 3) Where double piers are used, concrete blocks and steel shims may be use in-leu of top cap tz f Im d X 2 Beam f III=1=1�1 111111111111111111111=�--------------Illlllllli��li� 111=1 i=F, I=� "- _ITi= 1 , Steel Shims Concrete Top Cap i T (Double Pier - See Note 3) 6" Diameter by 12" Long j Precast Concrete Cylinder W/ Reinforcing Steel i Precast Concrete Pier Detail Diagram�� Not to scale MUATIER ENGINEERING MNSUITANTS !iL 1902 Forest Glen LN Weatherford, Texas 76087 817-948-4004 CoiNDOYNERENSIM RING CONSULTANTS LLC Final Evaluation Renort for Foundation Repair Date: June 09, 2020 Attention: Structured Foundation Repair (The Client) Subject: Foundation Review 3409 Lookout Ct., Grapevine, Texas Authorization and Scone: Nortier Engineering Consultants, LLC (NEC) has been retained by the Client to perform an evaluation of the slab on grade foundation for a 2 story residential home located at the subject address in conjunction with foundation repairs performed by the foundation repair Contractor. This report serves as confirmation that repairs have been done, provides information on the post -lift condition of the foundation, and provides our reasonable professional opinion on the repair measures taken to improve the foundation performance. This report does not take into consideration any changes to the condition of the foundation or the surrounding soils after the date the evaluation was performed. Foundation Repair Details: The Contractor installed concrete piers to which the purpose of the installed piers is to improve the performance of the foundation by providing support at the piered locations in an effort to achieve relative levelness of the slab. Work also included the installation of the drainage improvement as shown on the attached figure. The repairs performed conform to the 2015 version of the International Residential Code. It is noted that the foundation generally slopes from back right to front left. Although not completely level, the foundation appears to perform as intended. It is understood that absolute levelness may not be achievable after repairs. Data and Observations: NEC performed a visual examination of the foundation for the subject property on 06/09/2020. NEC also performed a floor survey using a Zip -level Pro-2000 series, collecting relative floor elevations, to aid in surface topography mapping of the floor(s). Elevations shown are adjusted for the type of flooring encountered to reflect a consistent measuring plane. The map of the post -lift floor elevations can be seen in the figure attached to this report. Based on the data gathered and our professional engineering opinion, the repairs performed by the Contractor have improved the foundation to be within slope tolerances generally accepted as industry standards. Therefore, no further repairs are currently necessary and the foundation may be considered stable and fit for service and/or recommended for selling purposes. 1902 Forest Glen LN Weatherford, Texas 76087 817-948-4004 06JORYMENSINEIRING CONSULTANTS LLC General Recommendations: It is recommended that a guttering system be installed if the house does not have gutters. Installing a guttering system will direct water way from the foundation and reduce the potential for ground erosion near the foundation footing. It is also recommended that the grading around the perimeter of the building be maintained as sloping away from the foundation at a minimum of 6 inches fall within the first 10 feet from the foundation. Such grading configuration should prevent localized water from accumulating around areas of the foundation. Saturated soils decline in bearing capacity and can result in differential settlement of the foundation. Additionally, It is also recommended that the soil be graded such that the bottom portion of the foundation is below grade, as per the governing code, and a watering system be utilized around the perimeter of the house. Fluctuations in moisture content of the soils near the foundation of the house can cause differential settlement. If the moisture content is kept consistent, the potential for differential movement is mitigated. It is also recommended that the plumbing systems be checked if any repairs are performed on the foundation system. Vertical movement of the foundation system can impose stresses on the plumbing infrastructure and cause leaks. Limitations: This report is intended for information purposes only, and the sole use of the client and/or homeowner. The scope of this report is limited to the items related to the foundation system only, and it is understood that detection of all existing or potential defects is not feasible for this type of evaluation. The intent of the work provided does not include judgment on any of the superstructure, detached buildings, retaining or privacy walls, concrete reinforcement, and/or site drainage. In addition, material and soil sampling/ testing, procedures were not performed. The report is not to be used by others for any purpose without our written consent. Compliance with any code or specification other than as expressly noted in this report is specifically excluded. It is the responsibility of the Contractor to adhere to any other applicable codes or specifications. No warranty for any repairs, future foundation performance, structure, vegetation, or soils at the subject property are offered by this report, nor does this report imply any liability to NEC, nor Daneel Nortier, PE for any work to be performed as a result of this report. It is understood that soils in this area experience movement due to moisture fluctuations. Such soil movement could cause the foundation to move after the recommended repairs have been made. Any provided floor elevation data and recommended actions (if any) are based on soil conditions as they exist at the time of the evaluation. NEC does not warrant or imply that other problems may not occur in the future. No warranty, expressed or implied, is made or intended and the limit of liability shall be limited to the fee paid for this report at the time of evaluation. Report Prepared by, Nortier Engineering Consultants LLC Texas Engineering Firm (F-16800) 06/09/2020 Daneel Nortier, P.E. Professional Engineer (TX #113157) \\\ OF 1 %t Photograph Label New pier r Stress crack SP Separation --- French Drain 0 10 All measurements shown in decimal inches Cone. Cone. Carport Cone. Cone. Driveway 20 1 06/09/20 By: TJ Pool and Pool and decking decking SP A4 0.7 FP ---------- 0.8 1.6 2.1 3.4 3.7 SP /0.2 0.3 0.7 1.0 1.4 2.5 i 2.9 Zero 2.0 6 1.2 2.0 2.8 ; 0.8 1.2 3.0 1.7 -0.2 ; I l � 1 ' Entry 1.1 0.8 0.6 � 2.6 �4o 'c pQQ.�tA' 3409 Lookout Ct Grapevine, Texas NNam! suluxlsric