Loading...
HomeMy WebLinkAboutSFRA2020-0078 (2)DATE OF ISSUANCE: 'AN 0 F�� PERMIT #: d—v- 00-1 Is IW—' BUILDING PERMIT APPLICATION (PI EAS : PRINT LE IBLY — COMPLETE ENTIRE FORM) JOB ADDRESS: I ' VV�,1 1 1 LOT: 14 BLOCK: F SUBDIVISION: College Creek SUITE # BUILDING CONTRACTOR (company name): Structured Foundation Repairs Inc. CURRENT MAILING ADDRESS: 13301 Trinity Blvd. #133 CITY/STATE/ZIP: Euless, TX 76040 PH: # 972-484-1200 Fax # 972-484-1215 PROPERTY OWNER: Jay Powell CURRENT MAILING ADDRESS: 1255 W Hudgins St CITY/STATE/ZIP: Grapevine, TX 76051 PHONE NUMBER: 4176296885 PROJECT VALUE: $ 7340.00 FIRE SPRINKLERED? YES NO X WHAT TRADES WILL BE NEEDED? (check ones that apply) ELECTRIC PLUMBING MECHANICAL DESCRIPTION OF WORK TO BE DONE: install 15 concrete pilings to stabilize foundation USE OF BUILDING OR STRUCTURE: Residence NAME OF BUSINESS: Total Square Footage under roof: 2964 Square Footage of alteration/addition: ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Patricia Palos SIGNATURE nn,��r ,- PHONE #: 972-484-1200 EMAIL: CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ Setbacks Approval to Issue Occupancy Group: Fire Sprinkler: YES NO t Front: Electrical Division: Building Depth: Left: Plumbing Zoning: Building Width: Rear: Mechanical' --- I Occupancy Load: Plan Review Approval: Date: Site Plan Approval: �� Date: Fire Department: Date: Public Works Department: Date: Health Department: Date: Approved for Permit: Date: Lot Drainage Submitted: Approved: P.O. BOX 95104, GRAPEVINE, TX 76099 (817) 410-3165 Right: Building Permit Fee: Plan Review Fee: —ol Lot Drainage Fee: Sewer AvailabilitN Rate: Water Availability Rate: Total Fees: j <- , flU f Total Amount Due: r �L O:FORMSIDSPERMITAPPLICATIONS 1/02-Rev.1110 210 ,1 /11 . BUILDING --- RESIDENTIAL ALTERATION ,GRAPEVINE. INE. Issue Date: January 7, 2020 PROJECT DESCRIPTION: Foundation Repair PROJECT # (817) 410-3010 WWW.mygov.us SFRA-20-0078 Inspections Permits City of Grapevine LOCATION LEGAL P.O. Box 95104 1255 W Hudgins St. College Creek Blk F Lot 14 Grapevine, TX 76099 Grapevine, TX 76051 Less Portion With Exemption, 50% Of Value (817) 410-3165 Voice (817) 410-3012 Fax CONTRACTOR INFORMATION Structured Foundation Repairs, Inc. —APPLICANT NAME Patricia Palos 13301 Trinity Blvd. #133 —APPLICANT PHONE NUMBER 972-484-1200 Euless, TX 76040 County Tarrant (972) 484-1200 Phone Fire Sprinkler System? NO (972) 484-1215 Fax Square Footage 1996 VALUATION 12950 OWNER FEES TOTAL = $ 150.00 Brandon Eric Jones 155 E Russell Building Permit Fee, ($f 50.00 Flat Fee) Simple Aurora, TX 76078-4488 Alteration $ 150.00 AVAILABLE INSPECTIONS PAYMENTS TOTAL = $ 150.00 ► Building Final (required) Structured Foundation Repairs, Inc. (Thomas Kidd) ($150.00) Check on 0110712020 Note: CK315594 NOTICES 1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2) A copy of the signed permit and approved plans must be on site at all times. 3) The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). ignatwe Date MYGOV.US City of Grapevine I BUILDING --- RESIDENTIAL ALTERATION I SFRA-20-0078 I Printed 01/07/20 at 3:59 p.m. Page 1 of 2 ALL CHANGES REQUIRE APPROVAL Adam A. (oF, 1 &� QhPLANS CROSSTOWN Tampa: (813) 702 -3398 1 Dallas/Ft. Worth (469 751-7694 HALL BE � � KEPT ON JOBSITE ATALL TIMES Date: December 21, 2019 CONTRACTOR SHALL CALL. FOR Attention: Structured Foundation Repairs, Inc. (via e-mail) INSPECTIONS: (817) 410-3010 Subject: Structural Foundation Initial Inspection Report ******************************* 1255-1253 W Hudgins St., Grapevine, TX. 76051 CONTRACTOR REGISTRATION ' WILL BE REVOKED UPON PERMIT EXPIRATION. To Whom It May Concern: Crosstown Engineering (CE) was retained to conduct a review of the provided pier plan prepared by Struc- tured Foundation Repairs, Inc. (SFR) to determine if it is a reasonable limited plan of repair. CE visited the subject site to interview the property owner, observe the structure and terrain, and to verify the floor elevation data. We observed brick cracks, drywall cracks, floor cracks, frieze board separations and trim separations. that indicated settlement was occurring on the back -left side of the structure. These observations are confirmed by floor elevation data. SFR has proposed to perform the following in the approximate locations of the structure as indicated on the limited repair plan to support the foundation: • Install 15 total pilings (9 exterior, 4 exterior with concrete breakouts, 2 interior). Based on our observations, it is our opinion that the proposed plan of repair is reasonable. Because the structure has endured pre -repair foundation differential movement, residual differential elevation and per- ceptible floor slope may remain following the limited foundation repairs. This limited repair plan is in- tended to provide a reasonable repair to improve the performance of the foundation and is not intended to level the foundation. The contractor shall determine the amount of elevation correction needed based on the reaction of the structure during the lift in order to minimize damages and additional stress. Please see the Disclosure & Disclaimer, pier detail (if provided), and limited repair plan for more infor- mation and do not hesitate to call us if you have any questions. CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION Sincerely, Crosstown Land Development Services Per Id�g8k,#v6dniAa(ed letter from Registered Ervktanafirmingsite � Of InSP'�Gfr .pier installation when fork is complete. SHE-E-r: OF: REL1'ACif Doi=S_ gAUTH ~- ORIZE ANY woRIt IN DNFLICY,1,VITH &Q'1PODE OR Z.O,u'NG ORDINANCE. If YT ------- S TO BE KEPT ON 12/21/19TH T ALL TIMES DATE: 1-G 20 _^ BY: BUILDING INSPECTION DIVI A N RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF�WAY. ALL CHANGES MUST BE APPROVED Foundation Report ----- _ Page 1 of 4 lAN 03 20211 l a -SS W. I"-aww Adam A. Green, P.E. (FL & TX), MBA CROSSTOWN Tampa: (813) 702 -3398 1 Dallas/Ft. Worth (469) 751-7694 DISCLOSURE & DISCLAIMER It is known to knowledgeable professional engineers that the soils in this area are subject to movement due to expan- sion, contraction or densification of the soils etc. This soil movement could possibly cause the foundation to move after the remediation plan within the attached report has been implemented and may impact the stability of the foun- dation and cause damage. NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THIS FOUNDATION OR THE REPAIRS THERETO. Diligent foundation maintenance to maintain consistent soil condi- tions along the perimeter should reduce further problems after the recommendations within this report have been implemented. However, seasonal moisture variations, water leaks, erosion and other factors may affect the stability of the foundation and put it in danger of further damage. REPORT LIMITATIONS This report is written for informational purposes only and is not intended to be a detailed technical evaluation of the property or an inventory of defects. The opinions expressed in this report are based on a visual evaluation of current conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CON- CERNING THIS ENGINEERING REPORT. The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land De- velopment Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be responsible for: 1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and testing of the recovered samples, 2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and 3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions. Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically excluded. The provided Floor Elevation Map and resulting recommendations are based on conditions as they now exist and DOES NOT IMPLY OR WARRANT THAT OTHER PROBLEMS AND OR AREAS MAY NOT MANIFEST IN THE FUTURE. This report was prepared expressly for the client and expressly for the purposes t fission for use by any other person for any purpose, or by the client for different pu os stated in writing by CE. RELEASED FOR CONSTRUCTION CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSICI"LbLyTHE CONTRACTOR Q S SUBCON- TRACTORS PERFORMING WORK ON THIS PROJECT, OR T LFFiK IN FORM THE WORK IN ACCORDANCE WITH THE 1stMIA K+%'6 CONSTRUCTION MEANS, METHODS, TECHNIQUES, TIONS INCIDENTAL THERETO. CITY APPROVED PLANS TO BE KEPT ON CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FORA 9G"ffcATaAsMI.e ijIj Ce�' pressly disclaims that it has contracted for or received any warranty of t es ror a particular purpose with respect to this report. THE REPORT UNDER THIS AGREEMENT IS ��NION OF CE AND THE NO WAR- RANTIES THAT EXTEND BEYOND THE DESCRIPTION ' I z V1SION: Foundation Repo P1 ReCG DOES NO-T APPLY TO CONSTRUCTION IN Page 2 of EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANCES MUST BE APPROVED PRESSED PILING SPECIFICATIONS SIDE VIEW FRONT VIEW ! EXISTING i I f I STRUCTURE i I FOUNDATION - STEEL SHIMS % CONCRETE CYLINDERS SOIL - CONCRETE > CAP 12" LENGTH 6" DIAMETER AND/OR 8" LENGTH 4" DIAMETER PILE SECTIONS e ' r '• z TENSILE STRENGTH j PROVIDED BYTWO o fi COLUMNS OF #3 OR w #4 SCHEDULE 60 m REBAR EPDXY OR a Co GROUT IN PLACE. _ LL Ir Z Z T a w REBAR SHALL w PREVENT LATERAL a DISCONNECT BETWEEN CYLINDERS. 12", 18" OR 24" SECTIONS " ° MAY BE USED. 1 _ CTom`` RELEASE :' -CO ~ t i loy f� 'ADAI A- GREEN SHEET: ti- "i 1 — ............. .................. —� RELEASE FOES NOT AUT 5� IN V CONFLICT WITH THE BUILDING COQE4l7�'`�iDINANCE. 1255-1253 W Hudgins St., Grapevine, TX. 76051 _- ``` — GffY AP'P'RUVLU MANS I U t3h KENi ON CROSSTOWN CROSSG TBPE FI 15944 - VWWV.CROSSTOI�j(�V�NGINEERING.COM DATWz ..,, ;aa - na�_I nc nn iCPl Cv BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION INI EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED CONSTRUCTION NOTE: IF INTERIOR PILING LOCATIONS ARE SHOWN PLEASE NOTE: THIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING ON THIS MAP THEY ARE APPROXIMATED AND ARE LOCATED WITHOUT AND CONSTRUCTION PURPOSES ONLY. IF EXISTING PILINGS ARE SHOWN -KNOWLEDGE OF THE'LOC-AT-IONS-OF THE -INTERIOR -GRADE --BEAMS— ON -THIS -MAP-, THEIR,LOCATION-WAS-P-ROVIDED-B-Y-THE-CLIENT-AND-IS THE CONTRACTOR SHALL MAKE FIELD JUDGEMENTS BASED OFF OF APPROXIMATE. CE DOES NOT CERTIFY THEIR PERFORMANCE OR j THEIR GRADE BEAM;NVESTIGATIONS AND OBSERVED SLAB QUALITIES EXISTENCE. IF THE READER WOULD LIKE TO DETERMINE IF THEY ARE' TO - FIELD LOCATE -T-HE-FINAL-INTERIOR-PIER-LOCAT-IO-NS.-FINALSCOPE ACTUALLY_PRESENT,iTHE1LMUSTCONTACTTHE_OWNERQRCONTRACT-OR- CHANGES SHALL BE APPROVED BY THE ENGINEER OF RECORIJ. TO OBTAIN AN ENGINEERING CERTIFICATE FOR THEM. ' 12 1 3 4 5 6 - � - � 0.7 I -09 ! -0.6 04 0.1 0.9 .. 1 1 1 -- s - i----I- 10-----1--- ! ® -0.3 � 0.3 0.9 i 1 -0.2 _ A A 0.3 T! SI -- - i-- T - -- - 1 0.0 1 1 0.5 0.9 1.5 FP 0.5 R R �I � 1 I 0.71 0.3 -1.8 -- - MONO 0.5 72 �- 13 0.0 -0.5 0.5 MONO I I i i L.0.0_:J 0 i II ISAN --'--GARAGE -GARAGE I- 15� 1 I I 1 I i I I I 1 j 0.2 -0.1 -0.21 0.71i 1 EXISTING PILINGS L_I I p� I I DM/ I fF-'_J 1--- -- II-_THI_S AREA - -i - -'! 1253- - -i -i — -1255 -- - -� — -I--- -- FRONT - - - -- INSTALL 15 TOTAL PILINGS (9 EXTERIOR, 4 EXTERIOR WITH BREAKOUTS, 2 INTERIOR). LIMITED REPAIR PLAN "NOT TO SCALE - ALL LOCATIONS APPROX T�L _MINE -0.6 10.0 -01 0.3 0.4 PRE -LIFT ELEVATIONS BY CE (12.20.19) 0.0 POST -LIFT ELEVATIONS BY LEGEND-C.Fi��'.::...............-.......................... ...... SHEET ApAMA.GREEN ELEVATION BASEPOINT PROPOSED PAD/BLOCK X EXI PROPOSED BEAM EXISTING PAD/BLOCK � 'DES NT A O E A tq-lkWnFWNTL DING CODE OR zOA EXISTING BEAM PROPOSED PIER EXISTING BREAKOUT T wN ENGINEERING I FOUNDATION REPAIR 1255-1253 W. HUDGIN CR Y OV S N TBPE FIRM F-15944 - Djjf4) 'cBUILDING INSPECTION DIVISION: OLMAWEMS RtLkA�E UUt� NO APPLYLTNIMMED TI.} C;UNSTRUCTION IN S ST'' I , I11 iislisIJII; II I I --- - ROSSTOWN Date: August 12, 2020 Adam A. Grccii, P.E. (FI, & 'I'X), MBA Tampa: (813) 702 -3398 1 Dallas/R. Worth ('169) 751-7694 " \ Attention: Structured Foundation Repairs, Inc. (SFR) (via e-mail) Subject: Final Report & Inspection 1253-1255 W. Hudgins St., Grapevine, TX Dear Structured Foundation Repairs, Inc. and Property Owner: Structured Foundation Repairs, Inc. (the contractor) retained Crosstown Engineering (CE) to visually in- spect foundation repairs completed by Structured Foundation Repairs, Inc. Crosstown Engineering visited the property, conducted a visual inspection, and determined that all work, including any approved changes, has been completed per our original report dated 12/21/19. Based on information provided by Structured Foundation Repairs, Inc. and visual observations, it appears that the following was performed: 0 Installed 15 total pilings (9 exterior, 4 exterior with concrete breakouts, 2 interior). The elevation data obtained during the inspection indicates the foundation is supported by pilings to pre- vent further downward movement and may have been lifted. In some cases, the pilings are meant to sup- port the foundation and minimal to zero lift was intentional. We recommend post -lift plumbing tests be performed on the sewer and potable plumbing lines and that any leaks be immediately repaired. This limited repair plan is intended to provide reasonable repair to improve the performance of the foundation and is not intended to level the foundation. The contractor determined the amount of elevation correction needed based on the reaction of the structure during the lift in order to minimize damages and additional stress. If you have any questions or need additional information, please call our office. Sincerely, Crosstown Land Development Services Texas Engineering Firm (F-15944) Adam Green, P.E., MBA Professional Engineer (TX #116597) EENS•.! 116597 8/12/20 ciceNac.. AV 8%ONA4 23+_ �r Foundation Report Page 1 of 3 CROSSTOWN DISCLOSURE & DISCLAIMER clam A. Green, Y.L. (FLA TX), \113.1 Tampa: (813) 702 -3398 1 Da➢av-Ft. Worth (169) 7551,7691 nr� is known to knowledgeable professional engineers that the soils in this area are subject to movement due to expan- sion, contraction or densification of the soils etc. This soil movement could possibly cause the foundation to move after the remediation plan within the attached report has been implemented and may impact the stability of the foun- dation and cause damage. NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THIS FOUNDATION OR THE REPAIRS THERETO. Diligent foundation maintenance to maintain consistent soil condi- tions along the perimeter should reduce further problems after the recommendations°within this report have been implemented. However, seasonal moisture variations, water leaks, erosion and other factors may affect the stability of the foundation and put it in danger of further damage. REPORT LIMITATIONS This report is written for informational purposes only and is not intended to be a detailed technical evaluation of the property or an inventory of defects. The opinions expressed in this report are based on a visual evaluation of current conditions observed at the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CON- CERNING THIS ENGINEERING REPORT. The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land De- velopment Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be responsible for: 1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and testing of the recovered samples, 2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and 3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily available to CE for viewing, and releases CE from any liability attributable to such knowledge or conditions. Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance of the facility at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically excluded. The provided Floor Elevation Map and resulting recommendations are based on conditions as they now exist and DOES NOT IMPLY OR WARRANT THAT OTHER PROBLEMS AND OR AREAS MAY NOT MANIFEST IN THE FUTURE. This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission for use by any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in writing by CE. CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSIONS BY THE CONTRACTOR OR HIS SUBCON- TRACTORS PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PER- FORM THE WORK IN ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAU- TIONS INCIDENTAL THERETO. CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client ex- pressly disclaims that it has contracted for or received any warranty of fitness for a particular purpose with respect to this report. THE REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WAR- RANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT. Foundation Report Page 2 of 3 CONSTRUCTION NOTE: IF INTERIOR PILING LOCATIONS ARE SHOWN PLEASE NOTE: THIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING ON THIS MAP THEY ARE APPROXIMATED AND ARE LOCATED WITHOUT AND CONSTRUCTION PURPOSES ONLY. IF EXISTING PILINGS ARE SHOWN KNOWLEDGE OF THE LOCATIONS OF THE INTERIOR GRADE BEAMS. ON THIS MAP, THEIR LOCATION WAS PROVIDED BY THE CLIENT AND IS THE CONTRACTOR SHALL MAKE FIELD JUDGEMENTS BASED OFF OF APPROXIMATE. CE DOES NOT CERTIFYTHEIR PERFORMANCE OR THEIR GRADE BEAM INVESTIGATIONS AND OBSERVED SLAB QUALITIES EXISTENCE. IF THE READER WOULD LIKE TO DETERMINE IF THEY ARE TO FIELD LOCATE THE FINAL INTERIOR PIER LOCATIONS. FINAL SCOPE ACTUALLY PRESENT, THEY MUST CONTACT THE OWNER OR CONTRACTOR CHANGES SHALL BE APPROVED BY THE ENGINEER OF RECORD. TO OBTAIN AN ENGINEERING CERTIFICATE FOR THEM. 1 2 3 4 5 6 -0.7 -0.9 (-0.9) -0.6 (-0.7)-0.4 (-0.4) 0.1 0.9 (-0.2) (-0.8) (-1.0) (0.1) (0.5) s 40 (.0.2)10 (-0.3) (0.8) O (11 -0.3 0.3 0.9 -0 6 (0.0) (0.4) (0.7) 6 0.0) (.0.6) (-0.4) -0.2 (0.0) (0.2) (0.5) (1.1) A ■ 1.0 (0.0) (-0.4) -0.1 -0.4 (0.0) (0.0) (0.4) 0.3 (0.7) (1.3) S S (-0.1) (0.0) �FP (0.0) A A (0.5) (0.8) (1.5) 0.3 0.5 (-0.1) 0.0 1 1 0.5 0.9 1.5 FP R R S S I(0.0) (0.0) (1.4) 0.4 0.7 0.3 (0.3) -1 8 I jw__j (0.0) 12 (-0.5) 13 15 (-0.1) I MONO 0.5 0.0 -0.5 0.5 MONO 0.6 (-0.5) (-0.5) 0.6 (0.3) 0.0 -0.5 (-0.2) 1 ?4 I I I I Ism GARAGE GARAGE SDI I I I I 3 (NIA) (-0.) 1 I (-0.2) I 0.2 -0.1 -0.2 0.7 EXISTING PILINGS L_ DAN I I DNV __J THIS AREA 1253 1255 FRONT • INSTALLED 15 TOTAL PILINGS (9 EXTERIOR, 4 EXTERIOR WITH BREAKOUTS, 2 INTERIOR). LIMITED REPAIR PLAN 'NOT TO SCALE - ALL LOCATIONS APPROXIMATE" of Teti PRE -LIFT ELEVATIONS BY CE (12.20.19) O.O POST -LIFT ELEVATIONS BY CE (08.12.20) (X.X) LEGEND : t__• -_ ._"'r" ADAM A. GREEN ELEVATION BASEPOINT INSTALLED PAD/BLOCK X EXISTING PIER 116597 �0 0 8 / 12 / 2 0 "- 4 INSTALLED BEAM EXISTING PAD/BLOCK INSTALLED BREAKOUT EN?��'s� -EXISTING BEAM INSTALLED PIER9 EXISTING BREAKOUT CROSSTOWN ENGINEERING ROSSTOWN TBPE FIRM F-15944 - (469)-751-7694 - DALLAS METROPLEX ENGINEERING I FOUNDA10N REPAIR 1255-1253 W. HUDGINS ST., GRAPEVINE, TX. 76051 AUG 0 7 2020 ?-D —a o 2 S Vicki Hecko From: Patricia Palos< Sent: Friday, August 7, 2020 10:44 AM To: Vicki Hecko Subject: Request for Extension *** EXTERNAL EMAIL COMMUNICATION - PLEASE USE CAUTION BEFORE CLICKING LINKS AND/OR OPENING ATTACHMENTS *** Good morning, I would like to request a onetime 180 day extension for permit number SFRA-20-0078 for property address 1255 W Hudgins St. The customer was not wanting to do the work with all the rain and interiors as well as tenant issues and is now able to do the work. Thank you so much for your assistance. Patricia Palos Production Manager Structured Foundation Repairs, Inc. D: 817-553-0202 O: 972-484-1200 F: 972-484-1215 Follow us on Social Media: https://www.faccbook.com/StructuredFound/ ikngies list i SUPER SFRYgCE AWA R d This email and its attachments, if any, are intended for the personal use of the named recipient(s) and may contain confidential, privileged, or proprietary information. If you are not a named recipient, or an agent responsible for delivering it to a named recipient, you have received this email in error. In that event, please (a) immediately notify me by reply email, (b) do not review, copy, save, forward, or print this email or any of its attachments, and (c) immediately delete and/or destroy this email and its attachments and all electronic and physical copies thereof. Thank you.