Loading...
HomeMy WebLinkAboutDEMO2011-1392LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR (company name): Champan Construction CURRENT MAILING ADDRESS: 1415 Skyline Dr. CITY /STATE /ZIP: Hutchins, TX 75151 PH: # 972.225.4600 Fax # (972) 547 -4763 PROPERTY OWNER: Verizon Wireless leasee CURRENT MAILING ADDRESS: 800 Dove Lane CITY /STATE /ZIP: Southlake, TX 76092 PHONE NUMBER: Larry- 214- 475 -1475 PROJECT VALUE: $ 20,000.- - FIRE SPRINKLERED? YES NO No DESCRIPTION OF WORK TO BE DONE: Derno existing cell site at above address and return to original state USE OF BUILDING OR STRUCTURE: NAME OF BUSINESS: Verizon Wireless cell site Grapevine South (Original site * *Total Square Footage under roof: all open air Square Footage of atteration/addition: +/- 120 s.f.lease area ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1 & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). 4 PRINT NAME: Bill Bauman agent SIGNATURE—] U PH A 817 -271 -0022 Construction Division: Zoning: FAX #: 817-860 -0077 ❑ CHECK BOX IF PREFERRED TO BE LOWING IS TO BE COMPLETED BY THE BI Permit Valuation: $ Building Width: .L Building Depth: EMAIL: WTED BY E -MAIL 1G INSPECTION DEPA Setbacks Front: Left: Electrical to Issue http: / /mygov.us /pi /projects /newperm it /printperm it.php ?perm iti... wV� BUILDING DEMO GRA zT 11 ti Issue Date: May 6, 2011 UlfDemo existing cell site "Verizon" PROJECT # (817) 410 -3010 www.mygov.us City of Grapevine, TX DEMO -11 -1392 inspections permits P.O. Box 95104 Grapevine, TX 76099 LOCATION LEGAL (817) 410 -3165 Voice 3230 State 360 Hwy. Bear Creek Park Addition Blk 1 Lot 1 (817) 410 -3012 Fax Grapevine, TX 76051 CONTRACTOR INFORMATION Chapman Construction Company LP *APPLICATION STATUS In Review P.O. Box 2880 *CONDITIONAL USE REQUIRED? NO McKinney, TX 75071 *CONSTRUCTION TYPE IIB (972) 547 -4720 Phone * OCCUPANCY GROUP U OWNER *ZONING DISTRICT GU City Of Grapevine * *APPLICANT / TENANT'S NAME Bill PO Box 95104 —APPLICANT/ TENANT'S PHONE NUMBER 8172710022 Grapevine, TX 76099 -9704 County Tarrant Fire Sprinkler System? NO AVAILABLE INSPECTIONS Square Footage 120 MISC. Building Inspection VALUATION 20000 (required) Lot Drainage Inspection (required) FEES TOTAL = $ 473.96 * Final Fire Dept Inspection (required) Building Permit Fee $ 287.25 Building Final (required) Building Plan Review $ 186.71 PAYMENTS TOTAL = $ 473.96 Chapman Construction Company LP (Calvin Hargrave) Check on 0411812011 ($186.71) Note: Check #6324 Chapman Construction Company LP (Calvin Hargrave) Check on 0510912011 ($287.25) Note: Check #1297 NOTICES 1) ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL / OWNER IS RESPONSIBLE FOR OBTAI G SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGEN (S). P Appli ant's Signature Date I of 2 5!0/1011 1 1 •A1) A T%/1 http://mygov.us/pi/projects/newpenn it /printperm it.php ?perm iti... City of Grapevine, TX BUILDING DEMO PROJECT # DEMO -11 -1392 Issue Date: 2011 -05 -06 24 HOUR INSPECTION NUMBER METRO (817) 410 -3010, CUT OFF TIME FOR AM. INSPECTION IS 7:30 A.M. - -- CUT OFF TIME FOR P.M. INSPECTION IS 12:30 P.M. PERMIT ISSUED IN ACCORDANCE WITH APPLICATION ON FILE IN THIS OFFICE. THIS PERMIT SHALL EXPIRE IF WORK IS NOT COMMENCED WITHIN (180 DAYS) OF ISSUANCE OR IF WORK IS SUSPENDED OR ABANDONED FOR APERIOD OF (180 DAYS). THE ISSUANCE OR GRANTING OF THIS PERMIT AND / OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF THE CODES AND ORDINANCES OF THE CITY OF GRAPEVINE. THE ISSUANCE OF A PERMIT BASED ON PLANS, SPECIFICATIONS, AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS, AND OTHER OR REQUIRING CORRECTIONS OF THE CONSTRUCTION ITSELF. 2 of 2 5/9/ ?01 1 11 •40 AM e t emoval Pa e 1 k' From: Scott Dyer To: Allen Hunt Date: 4/28/2011 3:53 PM Subject: Re: Cell tower equipmewnt removal we are interested only if it involves one of our elevated /cell towers and /or has demo of lines /equipment in rights -of -way, etc. Scott >>> On 4/28/2011 at 8:13 AM, <Ahunt(a)_grapevinetexas.gov> wrote: Albert, I do not remember what you had told me about the removal of the Verizon cell equipment from the power line pole at 3230 St Hwy 360. Do you have any issues with this ... Scott do you have any interest in this project, Verizon is removing their cell equipment from a electric power pole at this location. Thank's Allen CC: John Robertson; Mitzi Parks Allen Hunt 3230 St Hwy 360 Cell Tower Pale 1 From: Allen Hunt To: Subject: 3230 St Hwy 360 Cell Tower M Would you give me a summary of the project for this cell site? The demo and any new work this will lead to. Also I will need 3 more copy's of the plans for distribution to Public Works and Fire Dept. Thank You, Allen Hunt Plans Examiner, City of Grapevine (817) 410 -3129 aft ru 04 a 611 11 lill liq 11 11 PROJECT D&TA, A& ENGINEERS: P4 )PASS LN E GLADE RD "CINM AAAP 3., TARRWCOMM 60 1 tD I N'tt�41spMM"M s 11 C-"j LEASE DCE-Z EASEMENTS OR ON PWDLt;Ca '7 "' �' "', � " �j " -1 ALL CIIANC'k�-'� ;-o w$4 m4y 'o a LA 9 OF A 14 .................... JOSEPH S. ABBOUD ........................ 69894 lip THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHOR17FD BY 'JOSEPH S. ABBOUD, RE 69894 ON 02,119,107 I rPRINTED DAM 02/19/07 DRAM BY- V.N. go 1-- 1 PROJECT # 06-040-0647 GENERAL NOTES: THE FOLLOWING GENERAL NOTES CONSTITUTE A MAJOR PART OF THESE CONTRACT DOCUMENTS STRICT COMPLIANCE WITH THESE NOTES IS ESSENTIAL TO THE PROCESS OF WORK AT SITE 1. CARE SHALL BE TAKEN TO LOCATE ALL EXISTING UNDERGROUND OBSTRUCTIONS, UTILITIES AND /OR EASEMENTS BEFORE DIGGNG OR DRILLING ON THE SITE \ 2. CARE SHALL BE TAKEN TO PROTECT THE SITE AND THE SURROUNDING AREA FROM \ FIRE HAZARD DURING "HOT" OPERATIONS ADEQUATE EQUIPMENT, PERSONNEL AND EMERGENCY COMMUNICATIONS SHALL BE PROVIDED TO PROTECT LIFE IN AND + SURROUNDING THE CONSTRUCTION SITE \ 3. ALL EXCAVATIONS SHALL BE BARRICADED FOR PERSONAL PROTECTION. 4. VERIFY REQUIREMENTS OF OTHER TRADES PRIOR TO PROCDING WITH FABRICATION OR INSTALLATION OF MATERIALS 5. COMPLETE SHOP DRAWING SHALL BE PROVIDED FOR ALL FABRICATED 17M FOR REVIEW PRIOR TO FABRICATION. STRUCTURAL DRAWINGS SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS 6. ALL WORK SHALL BE ACCOMPLISHED WITH ALL APPLICABLE STATE, LOCAL AND NATIONAL CODES OF THE CURRENT ACCEPIM EDITIONS THESE CODES INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: UNIFORM BUILDING CODE (OR LOCAL ACCEPTED CODE) THE AMERICAN ASSOCIATION OF STEEL. CONSTRUCTION — SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS THE AMERICAN CONCRETE INSTITUTE — BUILDING CODE REQUIREMMENTS OF REINFORCED CONCRETE AMERICAN WELDING SOCIETY — STRUCTURAL WELDING CODE — STEEL. TOWER DESIGN — STANDARD PER SA/71A — 222 — F SPECIFICATIONS 7. VERIFY ALL EXSTING SITE CONDITIONS, QUANTITIES AND DIMENSIONS BEFORE STARTING WORK. NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES OR INCONSISTENCIES BEFORE PROCEEDING WITH THE WORK. 8, ALL BIDDERS SHALL MST THE STE BEFORE BIDDING TO FAMILIARIZE THEMSELVES WITH EASIING CONDITIONS 9. THE BUILDER/SUBCONTRACIOR SHALL BE RESPONSIBLE WITH NO ADDITIONAL COSTS TO THE OWNER/LESSOR/ PROJECTOR MANAGEMENT TEAM FOR ALL FEES, PERMITS, INSPECTION FEES RELATED TO THIS PROJECT, OR SEE THAT ANY AND ALL SUCH CHARGES ARE PAID BY THE RESPECTIVE SUBCONTRACTORS ASSOCIATED WITH THIS PROJECT. 10. THIS BULDER/SUBCONIRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO E )STING FACILITIES AND SHALL REPLACE OR REPAIR TO THE ORIGINAL CONDITION AS DETERMINED BY THE PROJECT MANAGER, 11. CUT AND PATCH ANY AREAS WHERE REQUIRED BY THE SCOPE OF THIS PROJECT. MATCH EXISTING WORK AND MATERIALS EVEN IF SUCH WORK FALLS OUTSIDE OF THE LIMITS OF THIS CONTRACT. 12. THE OWNER OF THE SITE RETAINS TO SALVAGE RIGHTS TO ALL MATERIALS AND EQUIPMENT REMOVED FROM THE EXISTING WORK. MATERIALS AND EQUIPMENT NOT CLAIMED BY THE OWNER SHALL BECOME THE PROPERTY OF THE BUILDER/SUBCONTRACTOR WHO SHALL ASSUME COMPLETE RESPONSIBILITY FOR THE REMOVAL AND APPROPRIATE DISPOSAL THEREOF. 13, DIMENSIONS NOTED AS " + / —` OR "VERIFY ARE BASED ON MATCHING EXISITNG CONDITIONS AND MAY VARY SLIGHTLY FROM THE DIMENSIONS AS SHOWN. NOTIFY THE PROJECT MANAGER IF SIGNIFICANT VARIATIONS ARE ENCOUNTERED AT THE SITE 14. DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE ACCOMPLISHED IN SUCH A MANNER THAT NO DISRUPTION OF EXISTING FACILITY OPERATIONS WILL OCCUR. 15. THE NATURE BE THE SITE RELATED ACTIVITIES REQUIRES THAT ACCESS TO THE STE MUST BE MANAGED AT ALL TIMES DURING HOURS OF OPERATION AND WHEN THE SITE IS UNATTENDED. WORK WITH THE OWNERS REPRESENTATIVE FOR SAFETY AND SECURITY AT ALL TIMES PAVING NOTES: I. SITE PREPARATKIN SHALL CONSIST OF STRIPPING THE GROUND OF ALL VEGETATION AND DEBRIS. THE EXPOSED SUBW" SHALL BE PROOF —ROLLED TO DETECT LOCAL WEAK AREAS WHICH SHOULD BE EXCAVATED, PROCESSED, AND RECDMPACTED IN LOUSE LIFTS O APPROXIMATELY DM —INCH THICKNES& IN THE CONC. SLAB AREA, S EIGRADE . SILLS AND ANY STRUCTURAL FYI. SHALL BE COMPXIIED TO A M"m OF 95% OF THE MA)IMUM STANDARD DENSITY (ASIM D- 698 -78) AT A MOISTURE CONTENT WTIHIN 2% OF OPT". 2. LOCATON OF UNITES IS BASED UPON BEST AVAILABLE INFORMATON, AIM PNDR TO CONSTRUCTION THE CONTRACTOR SHALL VEM THE ACTUAL LOCATIONS IN THE FED. THE LEAST OF WHICH SOUL BE BY TELOHNNG THE MERWOIt4 UIRMES COORDINATING COMMITTEE 48 HDQRS PRIOR TO DOVATION ON SITE 1800- 245 -4545. \ '+ x A' NEW METER, DISC W/ GEN PLUG. REF. 1/Et j— NEW HOFFMAN BOX REF. 1/E.1 UNDERGROUND POWER do TELCO, REF. 3/0 (pL1END EXISTING POWER & TELCO SERVICES TO NEW BUILDING LOCATION, COORDINATE WITH VERIZON'S PROJECT MANAGER & LOCAL UTILITY COMPANY) ir i NOTE: TMs PUN IS SHOWN TO CLARIFY THE RELATIONSHIP OF PROPOSED VERIZON WIRELESS WORK TO OVERALL SITE ONLY. �s.., � !�T•':RI1 iti: 1. � %��., �,k�.h :a�l.h,. lug ' 0 i' r r 06STING 9 HT. CHAIN —LINK FENCE EOOSTING TXU LATTICE TRANSMISSION TONER s�. DSO Vii`® e in Ashford Crossing 11 1880 S. Dairy Ashford, Suite 425 Houston, Texas 77077 Tel (832) 327 -0701 Fax : (832) 327 -0708 4 1' ` s ,a O F.T��s* t . . JOSEPH S. ABBOUD ........................ �. 69894 +to,-. 47�ENSE�) '2ri THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY JOSEPH S. ABBOUD, RE 69894 ON Q2111 Q1107 Qrffli ED DATE: 02/19/07 DRAWN BY: V.M. CHECKED BY: J.S.A. SITE PLAN 161500 GRAPEVINE SOUTH 3230 HIGHWAY 360 GRAPEVINE, TX 76051 A.1 VERIZON WIRELESS �z 1 PROJECT INFORMATION: JURISDICTION: CITY OF GRAPEVINE CODE: OCCUPANCY: ZONING: - CONSTRUCTION TYPE: CO- LOCATION LATITUDE AND LONGITUDE: N32'53'52.48 ", W97'05'27.30" (NAD 27) SITE DIRECTIONS: FROM SOUTHLAKE OFFICE, TAKE TX -114 EAST. TAKE THE TX -26 EXIT ONTO W. TX -114 TOWARD FT. WORTH /COLLEYALLE. TURN RIGHT ON WILLIAM D. TATE AVE, TAKE LEFT RAMP ONTO TX -121 SOUTH TOWARD FT. WORTH, TAKE THE HALL. - JOHNSON RD. EXIT TOWARD WILLIAM D. TATE AVE. CONTINUE ON WILLIAM D. TATE AVE,/ HWY -360 FEEDER RD. SITE IS LOCATED ON THE RIGHT SIDE OF FEEDER BY BEAR CREEK PARK. APPLICANT: OWNER: VERIZON WIRELESS 500 W. DOVE RD. SOUTHLAKE, TX 76092 CONTACT: TIM PELTON TEL: (681) 831 -3241 CELL: (214) 629 -5179 TXU ELECTRIC COMPANY 500 N. ACKARD, SUITE 10140 DALLAS, TX 75201 CONTACT: DAVID RUSE TEL: (817) 215 -6658 PROPRIETARY INFORMATION: NOT FOR USE OR DISCLOSURE OUTSIDE VERIZON WIRELESS PERSONAL COMMUNICATIONS EXCEPT UNDER WRITTEN AGREEMENT CONSULTANTS ENGINEERS: OAK u W 7 PAR,B. LM PROJECT DESCRIPTION THIS PROJECT CONSIST OF DEMOLISH AND REMOVE CONCRETE PAD W/ CABINETS, COAXIAL. CABLES, DIRECTIONAL ANTENNAS, POWER AND TELCO EQUIPMENT FROM EXISTING TXU TRANSMISSION TOWER LOCATION. TEXAS ONE CALL SYSTEM DIG CALL BEFORE Fn6z UN E GROUNDY�LITIES OR POWER ENGINEERING SER+ACES - INDEPENDENT LOCATOR (210) 590-4936 u V4 7m S' S Mm d VICINITY MAP TARRAN COUIM ATE Y zk. BUILDING I S EC l0 DOES NOT APPLY TO Cr °Ir RELEASE �,.. APPLY FDA, 3TS 0R ()�41 t€qq �I PRELIMINARY NOT FOR I CONSTRUC11ON PROJECT # 06- 040 -0647 RINTED DATE: 05/04/11 g DRAWN BY: V.M. I; CHECKED BY : J.S.A. is TITLESHEET 161500 GRAPEVINE SOUTH ADDRESS: 3230 HIGHWAY 360 GRAPEVINE, U 76051 o T. 1 PROJECT # 06- 040 -0647 TOWER EQUIPMENT REMOVAL NOTES: 1. ALL COAXIAL CABLES, ANTENNAS, ANTENNA PLATFORM, GROUND BARS AND RELATED EQUIPMENT SHALL BE REMOVE FROM TOWER BY TXU OR THEIR SELECTED CONTRACTOR TO THE SATISFACTION OF TXU. 1 SITE ELEVATION e North Looking South \L2j SCALE: N.T.S. YI p Xf4 n n !� = = Hi EXISTING ANTENNAS U u U TO BE REMOVE EXISTING TXU LATTICE TRANSMISSION TOWER TO REMAIN Ll- DlreS an Mason Creek Industrial Park 21732 Provincial Blvd. Suite 130 Katy, Texas 77450 Tel : (281) 398 -7888 Fax : (281) 398 -7886 TX PE FIRM REGISTRATION No. F -11281 PREUMINARY NOT FOR CONSTRUCTION IDATE: 05/04/11 I UTILITY RACK AND EXISTING EQUIPMENT TO BE REMOVE i ■ ��� DOSTING CHAIN—UNK FENCE ..� TO BE REMOVE immi•. 4• . -.mac �!� �' °. °i- :''�_� TOWER ELEVATION 161500 GRAPEVINE SOUTH ADDRESS: 3230 HIGHWAY 360 GRAPEVINE, TX 76051 A.2 VERIZON WIRELESS