Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CU2022-07
:\ZCU\2022\CU22-07\CU22-07.1a.doc 1 BOMBSHELLS RESTAURANT 1. Addressed. The replat application and fee for Lot 2R1, block 1, Crossroads of DFW Addn. must be submitted to Public Works no later than 9:00 a.m. Monday, December 27th. Email a PDF of the revised final plans by Monday, December 27 at noon to emarohnic@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. All sheets • Addressed. Seal sheets. • Addressed. Not Addressed. Add title block as shown below in lower right-hand corner of Sheet 1 of 15. The new lot number on the submitted amended plan is Lot 2R1. Add a Title Block in the lower right-hand side of all sheets provided. Include the following information on all sheets: plan type; project name (subdivision name, lot and block designations); gross acreage; city, county and state name; survey and abstract name; and date of preparation. • Addressed. Add a purpose statement near the Title Block: The purpose of this Conditional Use request is to amend the previously approved site plan, proposing one new restaurant with outdoor dining, outdoor speakers, a forty-foot pole sign and to allow for the onsite possession, storage, retail sales of on- and off-premise consumption (beer, wine, and mixed-beverages) of alcoholic. • Addressed. Within the provided signature block to all sheets, correct the case number (CU22-07), add the Case Name and the Case Address. Number sheets as labeled below. Update “Department of Development Services” to “Department of Planning Services.” Original Image Removed. Plat CU22-07 JANUARY 6, 2022 BOMBSHELLS RESTAURANT 1031 STATE HIGHWAY 114 WEST PROPOSED LOT 2R, BLOCK 1, CROSSROADS OF DFW ADDITION Site Plan for Bombshell’s Restaurant Lot 2R1, Block 1, The Crossroads of DFW Ab. No. 553 City of Grapevine, Tarrant County, Texas 3.185 acres or 138,720 sq. ft. Date of Preparation: December 28, 2021 (or subsequent date or revision) O:\ZCU\2022\CU22-07\CU22-07.1a.doc 2 • Addressed. Submit the replat application for plat of Lot 2R1, Block 1, Crossroads DFW (Bombshells) and fee to the Public Works Department. Contact Deborah Wood at dwood@grapevinetexas.gov or (817) 410.3136. Dimensional Control Site Plan - Sheet 1of 22 • Addressed. Partially Addressed but utilize a common plan sheet scale size, such as 1”-60’ or 1” =100’ or some other scale that is legible. Change architects scale to an engineering scale. • Addressed. Addressed but change direction of leader arrow. The leader arrow should be pointing from the label of the proposed restaurant name to the polygon indicating the boundaries of the property. Add vicinity map with north arrow per site plan checklist. • Addressed. Add primary contacts at Bombshells and Duncan & Miller to site plan sheets. • Addressed. Label the existing zoning on the site plan drawing and include the existing zoning in the site data table. • Addressed. Extraneous labels carried over from survey removed. Not Addressed. Provide legend with the following corresponding symbols and labels indicating what they – FH, Fire Hydrant; LP, Light Pole; WV, Water Valve; WM, Water Meter; ICV, Not Sure; TP, Telephone Pole? BO, Not Sure; EB, Not Sure; San MH, Sanitary Sewer Manhole; STM MH, Stormwater Manhole, etc. Provide a legend with the names and symbols for all typology shown on the drawing. • Addressed. Show, label, and dimension all firelanes, fire hydrants and clear access to the fire department connection (FDC). • Addressed. Label and dimension a typical parking stall. The minimum 90-degree parking stall dimensions are 9’ wide x 18’ long. • Addressed. Show, label and dimension the total right-of-way width for Crossroads Drive. Show and label this roadway’s centerline. • Addressed. Provide a curve and line table per the Site Plan Checklist to confirm consistency with the bearings and distances provided on the submitted replat for Lot 2R1, Block 1, Crossroads of DFW Addn. • Addressed. Add the following notes to the Dimensional Control Site Plan: • The purpose conditional use permit request CU22-07 is to revise the approved site plan by combining two lots into one, allow the possession, storage, retail sales of on and off premise consumption of alcoholic beverages (beer, wine and mixed beverages), outdoor speakers, outdoor dining, and a forty-foot pole sign in conjunction with a restaurant. Refuse disposal areas shall be landscaped and screened from view. O:\ZCU\2022\CU22-07\CU22-07.1a.doc 3 Mechanical and electrical equipment including air conditioning units, shall be designed, installed and operated to minimize noise impact on surrounding property. All such equipment shall be screened from public view. The masonry requirements of section 54 shall be met. • Addressed. In two columns, provide a site data table per the Site Plan Checklist to required and provided for the following: height in stories and feet, total building area, lot area, total impervious area (including percentage of lot), total open space (landscaping including percentage of lot), and parking required within the building and outdoor seating. Add in the site’s zoning district of “CC” Community Commercial District. Match the area of the subject site to the area of the plat. • Addressed. Not Addressed. Label existing pole sign locations and their height. • Addressed. Remove parking space as shown below as it does not meet minimum parking stall dimensions: Original Image Removed. • Addressed. Add landscape bump-out as shown. One landscape median is required every 12 parking spaces: Original Image Removed. • Addressed. Label and dimension the 25’ front yard setback. • Addressed. Label and dimension the width of existing driveways to remain along SH 114 and Crossroad Drive. • Addressed. Not Addressed. Existing sidewalk should be labeled “Existing X’ Concrete Sidewalk” adjacent to Cross Roads Drive. Label existing sidewalk’s width along all surrounding rights-of-way. • Addressed. Update all labels to improvements as either existing or proposed. • Addressed Label all culverts under existing driveways shown along SH 114. • Addressed Label on building drawing the existing zoning, total building area in square feet, building height in stories and feet. • Addressed. Dimension and label the existing width and depth of the dumpster enclosure. • Addressed. If outdoor speakers exist or are proposed, provide a separate outdoor speaker plan. Provide specifications for speakers. • Addressed. Label adjacent zoning on surrounding properties to the east, west and south. NEW Floorplan Plan Comments (? of 15): O:\ZCU\2022\CU22-07\CU22-07.1a.doc 4 • Addressed. Comment rescinded. Labeled Sheet 2 of 15: Construction Floor Plan. Interior floor plan sheet is missing with 2nd submittal. Floor plan must be added back in to show each alcohol point of sale. NEW Site Plan Comments (1 of 15): • Addressed. Correct text over text on site plan drawing. • Addressed. Where is the proposed 40’ pole sign on Sheet 15 of 15 to be located? Show location and label height on Sheet 1 of 15. • Addressed. Remove the use of grayscale for labels for: typical parking spaces, firelanes, curb radii and other labels. Use full black ink so that the labels are easily read. • New Master Site Plan Comments (13 of 15): • Addressed. Correct Lot 1, Block 1 to Lot 2R, Block 1 in the title block and in the Project Data table to be consistent with proposed amendment plat submitted t and site plan (Sheet 1 of 15). • Addressed. Revise Lot 2, Block 2 (Phase 3) drawing to show building as demolished. Reflect this in the Project Data table for the same lot. O:\ZCU\2022\CU22-07\CU22-07.1a.doc 5 • Addressed. Refer to the email attachment with the recently approved site plan for Lot 2, Block 2, Crossroads at DFW to show changes per the recently approved changes for consistency. Façade Plan – Sheets 3 of 22 and 4 of 22 • Addressed. Provide an abbreviated material schedule referenced on all elevations on Sheets 3 of 22 (A6.0) and 4 of 22 (A6.1). • Addressed. Provide the following table for each elevation: Original Image Removed. This table should add up to the Summary table provided on Sheet 3 of 22. Photometric Plan – Sheets 11 of 22 • Addressed. Utilize a heavier line weight to show the limits of the property boundaries so that staff can determine if illumination levels do not exceed 3.0 foot-candle at the property lines. • Addressed Add the following Photometric notes: o The monument sign was included in the determination of the illumination levels. o Foot-candles at the property line shall not exceed 3.0. o On-premise light fixtures including the base shall not exceed 19 feet in height. Landscape Plan – 14 of 8 • Addressed. Add additional landscape bump-out and tree per screenshot below. One landscape median is required every 12 parking spaces: • Original Image Removed. • Addressed. Not Addressed. Notes were not added. Add the following note: Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained so as to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. • Addressed. Not Addressed. Note was not revised but was removed. Revise the following note: All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction. NEW Landscape Plan (10, 11, and 12 of 15): • Addressed. Correct purpose statement, “… (beer, wine, and mixed-beverages) of alcoholic” to ““… (beer, wine, and mixed-beverages) of alcohol.” Remove the “ic.” O:\ZCU\2022\CU22-07\CU22-07.1a.doc 6 Civil plans Building Inspections Contact Larry Grey - Plans Examiner at 817.410.3165 to discuss the following: 1. Addressed. Add the occupant load (588) to the cover sheet and revise the parking analysis to reflect this number (1 space per 3 occupants). 2. Addressed. FDC is unreachable in its current location within the dumpster enclosure. Relocate. Public Works Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil Engineer at 817.410.3136 for the following comments: 1. Addressed. Not Addressed. Driveway access easement between their lot and lot 3R block 1 needs to be dedicated. Cross access with old California Pizza Kitchen property needs to be considered. 2. Addressed. Not Addressed. No hang over in fire lanes. There is one area where parking will hang over. Parking space near building doesn’t work. (See Plan) 3. Addressed. Water taps need to come off back of property due to depth of waterline in front and because the front waterline is a transmission line. 4. Addressed. The existing water and sewer taps will need to be abandoned. This will need to be discussed due to the depth of the waterline. 5. Addressed. Not Addressed. All fire lanes need an inside radius of 30’ minimum. Fire lanes need to be called out with width and radii. 6. Addressed. Water connections should not be placed inside of dumpster enclosure. 7. Addressed. Not Addressed. Driveways need to be 90 degrees to Right of way. Width of driveways on Crossroads could be wider. NEW Civil Plans: O:\ZCU\2022\CU22-07\CU22-07.1a.doc 7 8. Addressed. Consider leaving room for a recycle dumpster in the dumpster pad area. 9. Addressed. The flume shown on the utility plan will not work with the sidewalk. Storm drain will need to be added to take care of the drainage for that area 10. Addressed. Sidewalk is required along the frontage of this site. Fire Contact Bryan Parker - Fire Marshal at 817.410.4420 or bparker@grapevinetexas.gov for the following comments: 1. Addressed. Not Addressed. Firelanes are now depicted but require an inside radius of 30’ minimum. Firelanes are not provided on plans and FDC is not accessible as currently shown Parks and Recreation Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 to discuss the following: None. E mail a PDF of the revised final plans by Monday, January 10th at noon to Do not reproduce final copies requested below prior to Planning Staff approval. The above comments must be reflected in the revised final submittal, for the next public hearing. Submit revised final submittal to the Planning Services at 200 South Main Street. The revised final submittal shall include Do not reproduce final copies requested below prior to Planning Staff approval.: Three blackline copies of each sheet, (minimum size 24 ” x 36 ”) One colored rendering of the landscape plan without text, (minimum size 24” x 36”) Thirty (30) reduced sorted (collated sets) copies at 11" x 17" three hole punched, stapled and z-folded (fold the right edge to the left edge and then fold the right edge in half to form a z-fold). Please direct all questions to Erica Marohnic at (8l7) 410-3155. 1.326 @ 1.607 @ 1.39 4 @ .9 95 @ 1 2 2 STATE H W Y 121W STATE HWY 114 WILLIAM D TATE AVECROSSR O A D S DR 3R3 3R4 5RA 3R 1 5R 2A 1 1R1 2A1 1R2 2B 1 C R O S S R O A D S O F D F W 8 8 9 8 C R O S S R O A D S O F D F W 8 8 9 8 1.79 1 @2R 4R.7 42 @ 61.18 @ HC CCWilliamDTateSH 114 SH121SH121SBENTERTEXANTRLSH121N B E X IT M A IN SH114WBEXITSH26 Cr o s s r oadsCU22-07Bombshells 0 100 200 300 400Feet ² Date Prepared: 1/6/2022 This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources wereused to gather this information. Every effort was made to ensure the accuracy of this data, however, no guarantee isgiven or implied as to the accuracy of said data. Su bject Prope rtie s 1 CU22_07_010622_010853PM_8dd4ebcf OWNER_NAME OWNER_ADDRESS OWNER_CITY OWNER_ZIP5 SITUS_ADDRESS OWNER_STATE LEGAL_LINECOLE CP GRAPEVINE TX LLC 12151 BLUFF CREEK FL 5 DR PLAYA VISTA 90094 1051 W STATE HWY 114 CA CROSSROADS OF DFW ADDITION,THE Block 1 Lot 3RWD - CROSSROADS LP 25 HIGHLAND PARK VLG STE 100-3 DALLAS 75205 1041 W STATE HWY 114 TX CROSSROADS OF DFW ADDITION,THE Block 1 Lot 2RCROSSVINES 1031 PARTNERS LTD 25 HIGHLAND PARK VLG STE 100-3 DALLAS 75205 1031 W STATE HWY 114 TX CROSSROADS OF DFW ADDITION,THE Block 1 Lot 1CHANDANI HOLDINGS LLC 4310 MARTHA AVE SACHSE 75048 1501 WILLIAM D TATE AVE TX CROSSROADS OF DFW ADDITION,THE Block 1 Lot 4RSB HAYWARD LLC 433 N CAMDEN DR STE 1070 BEVERLY HILLS 90210 1505 WILLIAM D TATE AVE CA CROSSROADS OF DFW ADDITION,THE Block 1 Lot 5RB-WINGS GRAPEVINE LP 8333 DOUGLAS AVE STE 1500 DALLAS 75225 1525 WILLIAM D TATE AVE TX CROSSROADS OF DFW ADDITION,THE Block 1 Lot 6REGIONAL AIRPORT JV 7015 SNIDER PLAZA #203 DALLAS 75205 1709 CROSS ROADS DR TX CROSSROADS OF DFW ADDITION,THE Block 2 Lot 2A1WINGLORD LTD 1815 THE EXCHANGE SE ATLANTA 30339 1711 CROSS ROADS DR GA CROSSROADS OF DFW ADDITION,THE Block 2 Lot 2A IMP ONLYCARRABBA'S ITALIAN GRILL 7015 SNIDER PLAZA #203 DALLAS 75205 1709 CROSS ROADS DR TX CROSSROADS OF DFW ADDITION,THE Block 2 Lot 2A IMP ONLY B-WINGS GRAPEVINE LP 8333 DOUGLAS AVE STE 1500 DALLAS, TX 75225 CU22_07_010622_010853PM Labels - Count: 9 Page 1 CARRABBA'S ITALIAN GRILL 7015 SNIDER PLAZA #203 DALLAS, TX 75205 CU22_07_010622_010853PM Labels - Count: 9 Page 1 CHANDANI HOLDINGS LLC 4310 MARTHA AVE SACHSE, TX 75048 CU22_07_010622_010853PM Labels - Count: 9 Page 1 COLE CP GRAPEVINE TX LLC 12151 BLUFF CREEK FL 5 DR PLAYA VISTA, CA 90094 CU22_07_010622_010853PM Labels - Count: 9 Page 1 CROSSVINES 1031 PARTNERS LTD 25 HIGHLAND PARK VLG STE 100-3 DALLAS, TX 75205 CU22_07_010622_010853PM Labels - Count: 9 Page 1 REGIONAL AIRPORT JV 7015 SNIDER PLAZA #203 DALLAS, TX 75205 CU22_07_010622_010853PM Labels - Count: 9 Page 1 SB HAYWARD LLC 433 N CAMDEN DR STE 1070 BEVERLY HILLS, CA 90210 CU22_07_010622_010853PM Labels - Count: 9 Page 1 WD - CROSSROADS LP 25 HIGHLAND PARK VLG STE 100-3 DALLAS, TX 75205 CU22_07_010622_010853PM Labels - Count: 9 Page 1 WINGLORD LTD 1815 THE EXCHANGE SE ATLANTA, GA 30339 CU22_07_010622_010853PM Labels - Count: 9 Page 1 CU22_07_010622_010853PM Labels - Count: 9 Page 1 O:\ZCU\CU22-07.4 January 20, 2022 (9:36AM) 1 TO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE PLANNING AND ZONING COMMISSION FROM: BRUNO RUMBELOW , CITY MANAGER ERICA MARONIC, DIRECTOR OF PLANNING SERVICES MEETING DATE: JANUARY 18, 2022 SUBJECT: DEVELOPMENT SERVICES TECHNICAL REPORT OF CONDITIONAL USE APPLICATION CU22-07 BOMBSHELLS RESTAURANT APPLICANT: Ryan Hughes PROPERTY LOCATION AND SIZE: The subject property is located at 1031 State Highway 114 West and is proposed to be replatted as Lot 2R1, Block 1, The Crossroads of DFW . The property contains 3.18 acres and has approximately 433.72 linear feet of frontage along State Highway 114 West and 532.22 linear feet along Crossroads Drive. REQUESTED CONDITIONAL USE AND COMMENTS: The applicant is requesting a conditional use permit to amend the previously approved site plans of CU92-14 (Ord. 92-59), SPRC CU03-51 and CU03-12 (Ord. 03-31), SPRC CU03-17 for a planned commercial center for two restaurants, specifically to allow the possession, storage, retail sales of on- and off-premise consumption of alcoholic beverages (beer, wine and mixed beverages), outdoor speakers, outdoor dining, and a 40-foot pole sign in conjunction with a restaurant. The applicant intends to combine existing Lots 2R and Lot 1, Block 1 into Lot 2R1, demolish two existing restaurant buildings (former Outback Steakhouse/Tilted Kilt and TGI Friday’s restaurants) and construct a new 8,820 sq. ft. Bombshells restaurant in its place. This restaurant is a sports-themed restaurant serving American food, beer, wine, and mixed-beverages. It will feature a large number of televisions and speakers both inside the O:\ZCU\CU22-07.4 January 20, 2022 (9:36AM) 2 building and within the outdoor dining area. Overall, the proposed building can accommodate 588 occupants, is required to provide 196 parking spaces and is providing 215 parking spaces. The applicant intends to alter the look of the existing 40-foot pole sign along the front of the property along State Highway 114 West. PRESENT ZONING AND USE: The property is currently developed as two separate lots with two restaurant buildings, associated parking, vehicle maneuvering areas and ground signs and is zoned “CC” Community Commercial District with a planned commercial center designation. HISTORY OF TRACT AND SURROUNDING AREA: The subject and surrounding property was zoned “I-1” Light Industrial District prior to the 1984 City-wide Rezoning. The subject property was rezoned from “GU” Governmental Use District and “PID” Planned Industrial Development District to “CC” Community Commercial District with a master site plan for a Planned Commercial Center in conjunction with an Outback Steakhouse restaurant (Z92-04 and CU92-14). The following approvals and amendments occurred on Block 1: • On December 15, 1992, City Council approved CU92-20 for an amended site plan for TGI Friday’s restaurant with on-premise consumption of alcoholic beverages and a 40-foot pole sign. • On January 18, 1994, City Council approved CU93-14 for a California Pizza Kitchen restaurant with on-premise consumption of alcoholic beverages and a 40-foot pole sign. • On March 22, 1994, City Council approved CU94-03 for TGI Friday’s to amend their floor plan by combining two smoking areas. • On May 17, 1994, City Council approved CU94-10 to allow for a Don Pablo’s restaurant with on-premise consumption of alcoholic beverages and a 40-foot pole sign. • On May 17, 1994, City Council approved CU94-11 to allow for a Boston Chicken restaurant and a 40-foot pole sign. • On September 20, 1994, City Council approved CU94-25 to allow for a Red Robin restaurant with on-premise consumption of alcoholic beverages. • On September 20, 1994, City Council approved CU94-26 for an amendment to Don Pablo’s floor plan. • On December 20, 1994, City Council approved CU94-36 which allowed for additional signage for the California Pizza Kitchen restaurant. • On May 16, 1995, City Council approved CU95-07 to allow for a Denny’s restaurant and a 40-foot pole sign. • On August 15, 1995, City Council approved CU95-18 to allow for a 20-foot and 40-foot pole signs for the Red Robin restaurant. O:\ZCU\CU22-07.4 January 20, 2022 (9:36AM) 3 • On April 21, 1998, City Council approved CU98-08 to allow for a 781 sq. ft. expansion to the TGI Friday’s. • On July 21, 1998, City Council approved CU98-29 for TGI Friday’s to amend their floor plan. • On October 2001, the Site Plan Review Committee (SPRC) approved CU01-61 to allow interior and exterior renovations to TGI Friday’s. The work was not started and the conditional use permit expired. • On May 20, 2003, City Council approved CU03-12 to modify the floor plan and exterior elevations for TGI Friday’s. • On May 18, 2004, City Council approved CU04-18 to allow for on-premise alcoholic beverage sales in conjunction with a Buffalo Wild Wings restaurant at the northeast corner of Crossroads Drive and William D. Tate Avenue. • On October 19, 2004, City Council approved CU04-36 and Special Use, SU04-03, to allow for the on-premise alcohol beverage sales and consumption and one pool table in conjunction with a Boston’s The Pizza Gourmet restaurant. • On May 25, 2005, the SPRC approved CU05-34 to allow a 159 sq. ft., 40-foot pole sign for Buffalo Wild Wings. • On September 28, 2006, the SPRC approved CU06-43 to allow a 603 sq. ft. outdoor dining area for Buffalo Wild Wings. • On December 21, 2006, the SPRC approved CU06-57 to allow a patio cover for the Buffalo Wild Wings outdoor dining area. • On February 17, 2009, City Council denied CU09-01 and SU09-01 to allow outdoor dining, a new 40-foot pole sign, and one billiard table for The Tilted Kilt restaurant, formerly TGI Friday’s. • On March 15, 2011, City Council approved CU11-03 to allow changes to the approved floor plan and exterior elevations for Buffalo Wild Wings. • On April 19, 2011, City Council approved CU11-05 to amend the previously approved site plan to allow the possession, storage, retail sales and on-premise consumption of alcoholic beverages, outdoor dining and outdoor speakers in conjunction with a Free Birds restaurant. • On October 18, 2016; City Council approved CU16-28 to amend the previously approved site plan for a planned commercial center with the possession, storage, retail sale and on-premise consumption of alcoholic beverages (beer, wine and mixed beverages) in conjunction with a restaurant, specifically to modify exterior elevations, floor plan, and to allow outdoor dining and outdoor speakers for Daylight Golf, formerly The Tilted Kilt).The work was not started and the conditional use permit expired. • On September 4, 2019, the SPRC approved CU19-23 to amend the previously approved site plan for a planned commercial center with the possession, storage, retail sale and on-premise consumption of alcoholic beverages (beer, wine and mixed beverages) and a 40-foot pole sign in conjunction with a restaurant, specifically to revise the pole sign for California Pizza Kitchen. O:\ZCU\CU22-07.4 January 20, 2022 (9:36AM) 4 SURROUNDING ZONING AND EXISTING LAND USE: NORTH: “HC” Highway Commercial District – Across State Highway 114 West: Grimaldi’s Pizzeria, La Madeleine, Chili’s Grill and Bar, Starbucks, and Uncle Julio’s restaurants SOUTH: “CC” Community Commercial District – Plucker’s Wing Bar and Hooter’s restaurants and a vacant lot EAST: “CC” Community Commercial District - State Highway 114 West and State Highway 121 WEST: “CC” Community Commercial District – former California Pizza Kitchen restaurant, and across William D. Tate Avenue, Classic Chevrolet AIRPORT IMPACT: The subject tract is located within “Zone B” Middle Zone of Effect, as defined on the “Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs” map. Within Zone B, the following uses may be considered only if sound attenuation included in building design: multifamily apartments, motels, office buildings, movie theaters, restaurants, and personal and business services. Single family residential and sound sensitive uses such as schools and churches should avoid this zone. The proposed restaurant is an appropriate use in the Zone B. A portion of the planned commercial center at the southwest corner is located within “Zoned C” Zone of Greatest Effect as defined on the “Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs” map. Industrial and commercial uses that can tolerate high levels of sound exposure are appropriate in “Zone C.” The applicant’s proposal is an appropriate use in this noise zone. MASTER PLAN APPLICATION: The Master Plan designates the subject property as a Commercial land use. The applicant’s request is compliant with the Master Plan. /em AFFIDAVIT OF PUBLICATION Account #Order Number Identification Order PO Amount Cols Depth 36004 195382 Print Legal Ad - IPL0054805 $142.20 1 59 L Tara BrooksAttention: CITY OF GRAPEVINE SECRETARY PO BOX 95104 GRAPEVINE, TX 760999704 THE STATE OF TEXAS COUNTY OF TARRANT No. of Insertions:1 Beginning Issue of:01/02/2022 Ending Issue of:01/02/2022 Before me, a Notary Public in and for said County and State, this day personally appeared Amanda Grisham, Bid and Legal Coordinator for the Star- Telegram, published by the Star-Telegram, Inc. at Fort Worth, in Tarrant County, Texas; and who, after being duly sworn, did depose and say that the attached clipping of an advertisement was published in the above named paper on the listed dates: Sworn to and subscribed before me this 3rd day of January in the year of 2022 Notary Public in and for the state of Texas, residing in Dallas County Extra charge for lost or duplicate affidavits. Legal document please do not destroy! Page 1 of 1 MEMO INVOICE Order No.:195382 Memo Date:01/03/2022 Bill-To Account:36004 Sales Rep:Haley Martin CITY OF GRAPEVINE SECRETARY PO BOX 95104 GRAPEVINE TX 760999704 Dates Order No.Description Product Size Billed Units Times Run Net Amount 01/02/2022 - 01/02/2022 195382 Print Legal Ad IPL0054805 FTW-Star-Telegram Legal | Legals & Public Notices CLS 1 x 59 L 59 L 1 $142.20 Please Return This Portion With Your Payment (Thank You) MEMO INVOICE Order No.:195382 Account No.:36004 Account Name:CITY OF GRAPEVINE SECRETARY Order Amount:$142.20 McClatchy Company LLC PO Box 510150 Livonia MI 48151 *** MEMO INVOICE *** Email questions to ssccreditandcollections@mcclatchy.com CITY OF GRAPEVINE SECRETARY PO BOX 95104 GRAPEVINE TX 760999704 McClatchy Company LLC PO Box 510150 Livonia MI 48151 Small format, surface mount loudspeaker Restaurant ∙ Retail ∙ Audio Visual ∙ Education ∙ Concourses ∙ Casinos ∙ Transportation Terminals ∙ Worship Facilities ∙ Large System Ancillary Support AD-S10T AcousticDesign™ Series AD-S10T Features • DMT™ (Directivity Matched Transition) ensures smooth, uniform frequency response over the coverage area • X-Mount™ system enables the loudspeaker to be easily installed and deployed at a variety of angles with no slippage over time • Advanced voicing filter sets using QSC Intrinsic Correction™, available through either Q-Sys processing or CXD amplifier platforms • Low-saturation and low-loss 70/100V transformers with 8Ω bypass • Lightweight ABS enclosures offer long-term durability and lasting good looks • Sealed input panel cover and powder coated aluminum grilles for added weather resistance • Meets IEC60529 IP-54 for dust and splash resistance • M10 fittings for optional yoke mount or suspended installations • Available in black (RAL 9011) or white (RAL 9010) • Complete EASE, CAD & BIM information available online The QSC AcousticDesign™ AD-S10T is a surface mounted 70/100V, 10” two-way loudspeaker system, ideally suited for a wide variety of foreground and background sound reinforcement applications. AcousticDesign™ series offers integrators a premium quality installed sound solution where performance, coverage, and aesthetics are paramount. Combined with unprecedented ease-of-installation and high weather resistance, the AcousticDesign™ series provides integrators a versatile and confident install solution. The AD-S10T features a high quality 10” weather treated paper cone woofer on a 2.5” voice coil. A carefully selected 1” exit, 1.4” compression driver perfectly matches the sensitivity and performance of the woofer for outstanding full-range reproduction. Consistent and even 90° axisymmetric (conical) coverage is achieved through DMT™ (Directivity Matched Transition), a QSC innovation which matches the directivity patterns of the woofer and the high-frequency waveguide at the crossover point. The result is a coherent transition between transducers and improved off-axis response. The even, accurate frequency response of the AD-S10T is aided by a 100-watt low-loss, low-saturation transformer with selectable taps, including an 8Ω bypass. To enhance weather resistance, the rotary selector is located on the back of the enclosure, protected by a weather grommet. With rugged ABS enclosures, sealed input panel covers, and powder-coated aluminum grilles for weather resistance, the AcousticDesign™ surface mounted series exceed IEC60529 IP-54 ratings for dust and splash resistance. Installers will appreciate the award-winning X-Mount™ system included with each full- range AcousticDesign™ model. This ingenious mounting solution achieves unprecedented ease-of-installation in horizontal, vertical, wall, or ceiling deployments. Knurled surfaces at the pivot planes ensure the load will not drift or sag over time. Articulation marks allow preconfiguration of the X-Mount™ while on the ground with no special tools required. Once secure, the loudspeaker installs in seconds, allowing the installer to work safer, smarter, and faster with repeatable results. The AD-S10T also includes M10 fittings for optional yoke mount (YMS10T) or shoulder eybolt (M10 Kit-C) accessories for installation versatility. To further enhance performance and speed of install with optimum result, advanced voicing filter sets using QSC Intrinsic Correction™ techniques are obtainable using Q-Sys networked audio processing platforms, including CXD amplifiers for a complete QSC systems solution. The AcousticDesign™ series feature a stylish appearance free of obtrusive logo adornments for aesthetically sensitive installations. AcousticDesign™ surface loudspeakers are available in QSC standard black (RAL 9011) or white (RAL 9010) and may be painted to match any decor. To assist in successful systems integration, complete EASE, CAD, and BIM files are available for online download at QSC.com. X-Mount™ (included) AD-S10T Details 1 0 0 1 k 1 0 k 1 0 0 9 0 8 0 7 0 6 0 5 0 1 0 0 8 0 6 0 4 0 2 0 0 Freque nc y (H z)Sound pressure, Level (dB)Impedance, Amplitude (ohm)2 0 5 0 2 0 0 5 0 0 2 k 5 k 2 0 k 9 5 8 5 6 5 5 5 9 0 7 0 3 0 1 0 F requenc y R es pons e (R aw) F requenc y R es pons e (I ntrins ic C o rre c tion™) I mpeda nc e (8 Ohm Bypass) 0 -2 -4 -6 -8 -10 -12 1k 10k 90 60 30 0 -30 -60 -90 Sound press ure, Level (dB) Frequency (Hz) (deg)500 2k 5k 20k Impedance / Frequence Response:Horizontal Contour: System Details AD-S10T Effective frequency range1 50 – 19k Hz Rated noise power / voltage2 250 watts / 45 volts (rms) Broad-band sensitivity3 92 dB SPL Coverage angle (-6 dB)90° Directivity factor (Q)10 Directivity Index 10 dB Maximum continuous SPL4 116 dB Maximum peak SPL4 122 dB Rated impedance 8 ohms Recommended amplifier power 500 watts Transformer taps 70 V: 100, 50, 25, 12.5 watts and 8 ohm bypass 100V: 100, 50, 25 watts and 8 ohm bypass HF transducer 1” exit / 1.4” voice-coil compression driver LF transducer 10” weather resistant paper cone woofer, 2.5” / 64 mm voice-coil Input connector type Euroblock connector with parallel output Enclosure material Painted ABS polymer Grille material Powder coated aluminum X-Mount material Powder coated aluminum Enclosure Details Ingress protection IP-54 Operating environment Designed for indoor and outdoor use Testing The AD Series loudspeakers qualified for outdoor use using the following tests: Salt fog: MIL-STD-810G Method 509.5 for 100 hrs. Humidity: MIL-STD-810G Method 507.5, Natural cycle B2, cyclic high RH for 7 days High and low temperature: tested to QSC internal standards between -20° and 50° C Operating Temperature Range -20 to 50 °C / -4 to 122 °F Net weight 31 lb / 15 kg Product dimensions 20.3” x 12.5” x 11.7” (516 x 318 x 298 mm) Shipping weight 40.6 lb / 18.45 kg Shipping dimensions 31.7” x 16.1” X 16.1” (805 x 409 x 409 mm) Included accessories X-Mount mounting system, euroblock connector, input panel cover Optional accessories YMS10T yoke mount, M10 Kit-C 1 Free-field, -10 dB from on-axis sensitivity 2 IEC60268-1 noise signal for 2 hours 3 On-Axis, free-field sensitivity, 2.83V, 1 m 4 Calculated from rated noise voltage and sensitivity Dimensions:Specifications: 318 mm (12.5 in)298 mm (11.7 in)298 mm (11.7 in)516 mm (20.3 in)318 mm (12.5 in)516 mm (20.3 in)318 mm (12.5 in)298 mm (11.7 in)298 mm (11.7 in)516 mm (20.3 in)318 mm (12.5 in)516 mm (20.3 in)318 mm (12.5 in)298 mm (11.7 in)298 mm (11.7 in)516 mm (20.3 in)318 mm (12.5 in)516 mm (20.3 in)As part of QSC’s ongoing commitment to product development, specifications are subject to change without notice. 1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174 AD-S10T Spec Sheet 06/08/2014 please recycle © 2014 QSC Audio Products, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC Audio Products, LLC in the U.S. Patent and Trademark office and other countries. DMT, Intrinsic Correction, and X-Mount are trademarks of QSC.