HomeMy WebLinkAboutESGN2019-2145* DATE OF ISSUANCE: ,(;RAP-EVINE._ r`my so 2019 1 PERMIT #: !` CO -�s• 00�3 SIGN PERMIT APPLICATION Sign A JOB ADDRESS: 301 Hwy 114 S. Access Rd. 1.�1 Ott SUITE # LOT: BLOCK: SUBDIVISION: NAME OF BUSINESS• Olive Garden Italian Kitchen PHONE NUMBER: SIGN CONTRACTOR (company name): Mister Sign Manz (OR ELECTRICAL SIGN CONTRACTOR) STATE LICENSE REQUIRED FOR ELECTRICAL SIGN CONTRACTOR CURRENT MAILING ADDRESS: 896 N. Mill St. #208 CITY/STATE/ZIP: Lewisville, TX 75057 PHONE NUMBER: 940-735-0951 TYPE OF SIGN: ❑ FREE STANDING ® WALL MOUNTED ❑ BANNER ❑ GRAND OPENING thru ❑ OTHER DESCRIPTION OF SIGN: Channel Letters. SIGN DIMENSIONS: T-2 1/8" x 10'-5" WALL DIMENSIONS: 23'-11" x 8T-5 3/8" ILLUMINATED? YES X NO REFACE? YES NO _)L_ ELEVATION: North elevation **In accordance with STATE LAW & CITY ORDINANCE, illuminated signs must be constructed, installed and wired by a State Licensed Electrical Sign Contractor or a State Licensed Master Electrician. Signs may also be constructed by a fabricator approved by a Nationally Recognized Testing Agency and labeled accordingly** VALUATION OF SIGN: S6.500 REQUIRED ATTACHMENTS: I. A separate permit and 2 sets of drawings are required for each sign. For wall signs a separate permit application and plans may be submitted for each elevation. 2. Pole or ground signs require a site plan drawn to scale showing location of the sign. Show dimensions and distances to property lines. Pole sign structural drawings must be sealed by a State of Texas Registered Professional Engineer. Monument and Ground sign applications must include footing detail. 3. Detailed, dimensioned plans of sign showing graphics. 4. Dimensioned building elevation showing sign or signs on building. Show dimensions of height & width of tenant space and or building. 5. Plan Review Fee, 65% of the permit fee is required when permit application is submitted. Balance due upon approval. If any other signs are on the property, give the number and the types I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE SAID WORK WILL BE DONE IN CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN REQUIREM NTS PRINT NAME. Landon White SIGNATURE: ilt PH #: 574-232-6933 FAX#: EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL FOR OFFICE USE ONLY FUNCTIONAL TYPE: CG W1 1 I ��Ye S B PERMIT FEE: STRUCTURAL TYPE: �t.S%im aa� c'y' PLAN REVIEW FEE:APPROVED BY: DATE: >�J:�3 �1 C REMAINING FEE: L,3� j O:F CVAPP may( 6l4/2004-Re004-Rev:3/05,5l06, 2/07,11/09 n- ��T&,X'VINE City of Grapevine P.O. Box 95104 Grapevine, TX 76099 (817)410-3165 Voice (817)410-3012 Fax CONTRACTOR Mister Sign Man State ID # 83665 896 North Mill St. # 208 Lewisville, TX 75057 (940)735-0951 Phone (940) 735-0951 Mobile OWNER Gmri Texas Lip PO Box 695019 Orlando, FL 32869-3330 AVAILABLE INSPECTIONS ► Building Pier (required) ► Sign Final (required) SIGN, ELECTRICAL Issue Date: August 28, 2019 PROJECT DESCRIPTION: Illuminated Wall Sign 7.17' X 10.41"'Olive Garden #1497" NORTH (CO 95-0063) PROJECT # (817) 410-3010 ESGN-19-2145 I Inspections LOCATION TENANT 301 W State 114 Hwy. Olive Garden #1497 Grapevine, TX 76051 INFORMATION " CONSTRUCTION TYPE • OCCUPANCY GROUP • ZONING DISTRICT "APPLICANT NAME —APPLICANT PHONE NUMBER CERT OF APPROPRIATNESS County Illuminated / Non -Illuminated ? Reface Sign Dimensions Type of Sign Being Installed VALUATION Wall Dimensions Wall Elevation Zoning FEES Sign Permit Fee (Plan Review) 65% Sign Permit Fee (Remaining Fee) 35% PAYMENTS Mister Sign Man (Josh & Mendi Tips) Check on 05/31/2019 Note: CK1812526 Mister Sign Man (Josh & Mendi Tips) Payment Voided Check on 0513112019 Note: WRONG AMOUNT Mister Sign Man (Josh & Mendi Tips) Check on 0513112019 Note: CK1812526 Mister Sign Man (Josh & Mendi Tips) Check on 0812812019 Note: CK3395 Www.mygov.us Permits LEGAL Metroplace Addition 2nd Instl Bilk 6 Lot 3 Olive Garden #1497 VB Sprinkler A-2/F-1 CC Landon White 574-232-6933 NO Tarrant Illuminated No 7.17' X 10.41' Wall 6500 23.91' X 87.44 North Elevation CC - Community Commercial TOTAL = $ 124.75 $ 81.09 $ 43.66 TOTAL = $ 124.75 ($124.75) $124.75 ($81.09) ($43.66) NOTICES ALL work must be done in compliance with the CITY OF GRAPEVINE SIGN ORDINANCE, SECTION 60. City of Grapevine CODE OF ORDINANCES. MYGOV.US City of Grapevine I SIGN, ELECTRICAL I ESGN-19-2145 I Printed 08/28/19 at 2:00 p.m. Page 1 of 3 And the 2005 NATIONAL ELECTRICAL CODE. In accordance with STATE LAW & CITY ORDINANCE, Illuminated signs must be constructed, installed and wired by a State Licensed Electrical Sign Contractor or State Licensed Master Electrician. Signs may also be constructed by a fabricator approved by a Nationally Recognized Testing Agency and labeled accordingly. READ AND SIGN I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT OT THE BEST OF MY KNOWLEDGE AND THAT THE SAID WORK WILL BE DONE IN CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN REQUIREMENTS. Signature Date MYGOV.US City of Grapevine I SIGN, ELECTRICAL I ESGN-19-2145 I Printed 08/28119 at 2:00 p.m. Page 2 of 3 ALL CHANGES REQUIRE ITALIAN KITCHEN S F S site enhancement services Ph:1.800.599.7696 Fax: 1 . 574. 237. 6166 www.siteenhancementservices.com PROVIDE DISCONNECTOR AT SIGN LOCATION APPROVAL r OF REVISED PLANS APPROVED PLANS SHALL BE KEPT ON JOBSITE ATALL TIMES CONTRACTOR SHALL CALL FOR INSPECTIONS: (817) 410-3010 CONTRACTOR REGISTRATION a WILL BE REVOKED UPON -' '� PERMIT EXPIRATION. FOR CONS] RUCTION SH'-:E-T: t OF: T Rf'-EASE DOES NOT AUTHORIZE ANY WORK IN NFLIt_T WITH THE BUILDING CODE OR ZONING ORDIIvAIvC.I >'— CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: `�� 23� tG BY: - BUILDING INSPECTION DIVISION ^1 q. RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED �- I� a � OFFICE COPY -� Q Q 7'-2 1/8" x 10'-5" Wall Sign: 74.76 SF 6'-7" x 15'-0" Wall Sign: 98.75 SF 3'-9" x 13'-5" W JI Cig': 50.31 SF n� G �� Y 111�_(1" 1A/�11 Cinn• 45. - w i u i "Wall' pn t'%.%1 Tv- is- 11'-8 7/8" x 17'-0 1/2" Pylon at 30'-0" GAH.. CITY OF GRAPEVINE RELEASED FOR- CONSTRUCTION. SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES. DATE: . BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED. Proposed Signage Existing Signage Site Plan Store #1497 SC S Ph: 1 . 800 . 599 7696 1 Fax: 1 , 574 . 237 6166 1 www.siteenhancementservices.com Page 2 of 5 87'-5 3/8" 14'-2 1 /4' EQ EQ n Proposed: 75 SF Wall Sign See pages 8 & 9 for sign details. Existing: Approx. 98.75 SF (provided by sign company) SE S Ph: 1 800 599 . 7696 1 Fax: 1 . 574 . 237. 6166 1 www.siteenhancementservices.com GpJ - 201, Scale: 1 /16"=1' Front Elevation Store #1497 CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION. SHEET: OF: RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE CITY APPROVED PLANS TO BE KEPT ON THE.JOB SITE AT ALL TIMES ATE: BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-0E-WAY. ALL CHANGES MUST BE APPROVED Page 3 of 5 CN N um % "THE S1CierI SHALL tool prW'jEc-1 M02E 'fYjArt %'.Z S F20 r4 'THE W ALt- 2" 2" LED Uplighting ®®®®®®®®®®®®®®®®®®®®®® Top View 10'-5" r ■ 9 B - W75 - Wall Sippn - 74.76 so ft SCALE: 1/2" = 1'-O' r 10'-5" r• 4'-10" O.C. 1.1 4'-10" O.C. CRY OF G - PEVINE RELEASED FOR INSTRUCTION SHEET: OF: RELEASE DOES NOT AVINORIZE ANY WORK IN OONR= WITH THE BUILDING DE OR ZONING ORDINANCE. CRY APPROVED PLA W S TO BE KEPT ON THE JOB SITE A.T ALL TIMES DATE: 3Y: BUILDING INSPEC'ION DIVISION: RELEASE DOES NOT APPL' I TO CONSTRUCTION IN EASEMENTS OR PUBIS C RIGHT-OF-WAY. ALL MUST BE APPROVEllngie Vertical Weld to Frame SCALE: 1/2" = 1'-0" PPROVIDE SEPARATE PLun MM cAi , D I S C O N N E CTO R ELECTRICAL AND SIGN PERMITS SHALL BE RlEQU01M AT SIGN LOCATION I OLIVE GARDEN NOTES .063 WRT/BLK ALUM BACKS .040 ALUM RETURNS STAPLED 5" K-LATH SCREWS 3/4' GEMINI WARM GREY TRIMCAP .177WHITESG10FACES jl5[ MFGD. BY P VSTILITE SURFACE APPLIED TRANSLUCE NT VINYL 3M 36304450 WARM GREY GEMX41 LED'S GEM TRIM, RETURNS, DETAIL SCREWS, AND BACKS TO BE PMS 1C WARM GREY VINE NOTES .063 WHT/BLK ALUM BACKS f %• i %" 112'.05DALUM STAPLED RETURNS K-LATH SCREWS T� 1 3W STANDOFFS PAINTED PMS 7533 BROWN RIM INI �{^^^--•'''' PLIED TP SURFACE APPLIED CENT SURFACE GREEN VINYL 3M 3730.GREEN GEMM71 LED'S .177 WHITE SG 10 FACES MFGD. BY PLASTILITE DETAIL B GEM TRIM. RETURNS, SCREWS, AND BACKS TO BE PMS 383C GREEN ITALIAN KITCHEN NOTES BE R ALUM POP RIV T0BENT8ENT.090 ALUM .090 ALUM REMOVEABLE LI`I—jrlllll`LI PANEL FOR SERVICING LED'S 3/4CLEAR ACRYLIC PUSH-THRU COPY WI 3730-5098 GREEN VINYL ON FACE AND PMS 3M GREEN PAINTED RETURNS GEMM71 LED'S .090 ALUM FACE OETAIL C LEDs SEE DETAIL B LED UPLIGHTINr CHANNEL TOGGLE SWITCH _ ACCESS DOOR AS REO'D PUT PRINTED LED SCHEMATIC ON BACK OF DOOR SPACERS FOR VINE 2 POWER SUPPLIES MOUNTED BEHIND SERVICE DOOR 125 ALUM. FACES W75 Wall Sign Tower 1._3" 1O.. I ALUMN. FILLER �r AND BACKS. J_L �qY 1 i;V I — V--- A -- T AV LEDs > v G II O SEE DETAIL A 1/2" CARFLEX AND CONNECTOR O- O 3/8" RIV-NUT 1 L Ly SEE DETAIL C LEDs L ■ L.E.D. TRANSFORMER (MOUNT ON SHELF OFF BOTTOM). - I DIGITALLY PRINTED —, VINYL TO MATCH PMS 7533C BROWN -- c 3M 373MO98 GREEN VINYL 1� + I VINE DETAIL 10" DP FABRICATED ALUMINUM CABINET WITH 2" DP CAP ON FACE, AKZO NOBLE PAINTED TEXTURED PMS 7533C BROWN TEXTURED MICRO POWDERS PROPYLTEX 50. POWER SUPPLIES TO BE ACCESSIBLE FROM REMOVABLE PANEL ON SIDE OF FABRICATED CABINET. MOUNTING: A) THRU-BOLT W/ %"O THREADED ROD WITH BLOCKING B) TOGGLES OR LAGS ARE ONLY TO BE USED IN EMERGENCY SITUATIONS GE Tetra EdgeStrip 1 3" 1 _ 3116" White Translucent _ GEWWBIP2 LEDs �� Polycarbonate face PMS me PM5 T533C W3730-sr�i° arawD PMS 1C Wa.Gray N 3M 3630-0450 `"■ .OBO"Aluminum break formed channel -34" CUSTOM COLOR TRIMCAP FROM GEMINI FOR GREEN & GRAY TO BE DEVELOPED (PART 4 NOTASSIGNED YET.) LED UDlq SCALE: 1-1 p1'-0' tirt� '•MULTI -TAP POWER SUPPLY CEPS 12-60U-NA 12CV/277V-.65/.29 AMPS EA THIS SIGN IS INTENDED TO BE INSTALLED IN ACC DRDANCE WITH THE REQUIREMENTS OF ARTICLE BOO OF THE NATIONAL ELECTRICAL COOS AND/DR OTHER APPLICABLE LOCAL CODES THI5 INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN @y Page 4 of 5 Tetra® LED Sstems CUSTOMER INFOR E ATION MATERIAL ESTIMATE — SPECIAL INSTRUCTIONS DRWG # I W75 I ESTIMATE FOR ONE SIDE OF SIGN ONLY 1) THE GRAPHICS BELOW ARE FOR REFERENt 115101flifild not be used far commercial quotation dnd without validation. The material estimates (detrae LED Systems are based upon our engineering standards amformation provided pertaining to font, letter hght can depth, face material. and any special imettions provided by the customer. Missing information will cause delays in ddry of estimate as well as affect product selectio quanlities, application, and illumination. 2) LED MODULE PLACEMENT AND OUANTITYABPROMMATION ONLThe sign manufacturemustverdy module placement and quantity to ensure endllumination. 3) Final material quantities for estimation purposolnd construction are the responsibility of thegn OEM. +) All signs should be lested as complete unitsclirding comect Tetra power supply) before installatiofor acceptable color, illumination, intensity.& fu:tionality. 5) For detailed information and instructions reflm the applicable Tetra® product found unde8ignage at; ±Lm w. elhtinasolutions_com Can De th Power Supply Location Illumination Total Amps Pri ary o I Watts (System) Total Area P1.5'I REMOTE I FACE / BACKLI1 2.0 Amps I 153.58 Watts 18.69 Sq Ft +aor+Stet �yA �f ij Drwg #: 0395438 01 Tetra® MAX I GEMX4181 TetraiI MAX GEMM7181 Tetra® miniMAX MS GEMS7181 MATERIAL LIST ST GEMX4181 115 Mod 58 Ft LED GEMM7181 31 Mod 12 Ft Module GEMS7181 160 Mod 64 Ft Power I GEPS1286OUBNA 3 Ea Su",Iy GEPS12821 0 Fa supply Wlre 9409 100 Ft Energy Linage Choose one wh 192160005 28 Ea connector 191600041 28 Ea 8.22 Watts/Sq F4 End Caps 191.0.041 16 Ea MATERIAL BREAKDOWN GEMX41AI Modules 1... O 15 W75 ` -„ I U 16 VE 18 I ' G 16 AR 20 ♦ I DEN 30 I . � I Lighting Solution TECH SUPPORT. 888A694A3533 / 216A266A2�9ihwnBy Tetra® LED Systems EMAIL:TETRADRAWINGS:tGE.COM Checked By: EAST CLEVELAND, OH 44112 EAFAX: 216 A 359 A 0075 Date: GEMM71A1 Modules PM IK 31 I GEMS71A1 Modules h:: LEAVES 160 .1 ` K� I Drwg #: 0395438 01 3/19114 PAGE 1 OF 1 Rev 8 W75 Wall Sign CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SHEET: OF: _ RELEASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH THE BUNG CODE OR ZONING ORDINANCE. CITY APPROVED PLANS TO BE KEPT ON THE JOB SITE AT ALL TIMES DATE: Y_ BY: BUILDING INSPECTION DIVISION: RELEASE DOES NOT APPLY TO CONSTRUCTION IN EASEMENTS OR PUBLIC RIGHT-OF-WAY. ALL CHANGES MUST BE APPROVED Page 5 of 5