HomeMy WebLinkAboutESGN2019-2148RRA VINE.ttllpY � 0 �Q1�
'I' E . 1 t S
DATE OF ISSUANCE:
PERMIT #: V �—C—H L+ 0
Co-q,5-oc0
SIGN PERMIT APPLICATION sign D
JOB ADDRESS: 301 Hwv 114 S. Access Rd. SUITE #
LOT: BLOCK: SUBDIVISION:
NAME OF BUSINESS• olive Garden Italian Kitchen
PHONE NUMBER:
SIGN CONTRACTOR (company name): Mister Sign Man
(OR ELECTRICAL SIGN CONTRACTOR) STATE LICENSE REQUIRED FOR ELECTRICAL SIGN CONTRACTOR
CURRENT MAILING ADDRESS: 896 N. Mill St. #208
CITY/STATE/ZIP: Lewisville, TX 75057 PHONE NUMBER: 940-735-0951
TYPE OF SIGN:
❑ FREESTANDING t'ZWALL MOUNTED ❑ BANNER ❑ GRAND OPENING thru
❑ OTHER R 004' 51 c4 Yi
DESCRIPTION OF SIGN: Channel Letters.
SIGN DIMENSIONS: T-9" x 13'-5" WALL DIMENSIONS: 19'-3" x 114'-4 5/8"
ILLUMINATED? YES x NO REFACE? YES NO ELEVATION: South Elevation
"In accordance with STATE LAW & CITY ORDINANCE, illuminated signs must be constructed, installed and wired by a State
Licensed Electrical Sign Contractor or a State Licensed Master Electrician. Signs may also be constructed by a fabricator
approved by a Nationally Recognized Testing Agency and labeled accordingly"
VALUATION OF SIGN: $4,000
REQUIRED ATTACHMENTS:
1. A separate permit and 2 sets of drawings are required for each sign. For wall signs a separate permit application and
plans may be submitted for each elevation.
2. Pole or ground signs require a site plan drawn to scale showing location of the sign. Show dimensions and distances to
property lines. Pole sign structural drawings must be sealed by a State of Texas Registered Professional Engineer.
Monument and Ground sign applications must include footing detail.
3. Detailed, dimensioned plans of sign showing graphics.
4. Dimensioned building elevation showing sign or signs on building. Show dimensions of height & width of tenant space
and or building.
5. Plan Review Fee, 65% of the permit fee is required when permit application is submitted. Balance due upon approval.
If any other signs are on the property, give the number and the types
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE
SAID WORK WILL BE DONE IN CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING Sl(N REQ NT
PRINT NAME: Landon White SIGNATURE: IJ �/L!
PH #: 574-232-6933 FAX#: EMAIL:
FOR OFFICE USE ONLY 81
FUNCTIONAL TYPE: PERMIT FEE: �C 1 A,rer,n I Se rJSi
STRUCTURAL TYPE: YR40f S1711 PLAN REVIEW FEE:
APPROVED BY: DATE: wtol J�4 REMAINING FEE:
O:F GAAPP
6/4R0D4-Re004-Rev:J/OS,SN6, 2/07,1 i/09 (/J(/L'�//•/(
.�.� VISE
}rT E% % i K't
City of Grapevine
P.O. Box 95104
Grapevine, TX 76099
(817) 410-3165 Voice
(817)410-3012 Fax
CONTRACTOR
Mister Sign Man
State ID # 83665
896 North Mill St. # 208
Lewisville, TX 75057
(940)735-0951 Phone
(940) 735-0951 Mobile
OWNER
Gmri Texas Lp
PO Box 695019
Orlando, FL 32869-3330
AVAILABLE INSPECTIONS
Building Pier (required)
► Sign Final (required)
SIGN, ELECTRICAL
Issue Date: August 28, 2019
PROJECT DESCRIPTION: Illuminated Roof Sign 3.75' X 13.41' "Olive Garden #1497" SOUTH (CO 95.0063)
PROJECT #
ESGN-19-2148
LOCATION
301 W State 114 Hwy.
Grapevine, TX 76051
(817) 410-3010
Inspections
TENANT
Olive Garden #1497
INFORMATION
* CONSTRUCTION TYPE
• OCCUPANCY GROUP
• ZONING DISTRICT
—APPLICANT NAME
—APPLICANT PHONE NUMBER
CERT OF APPROPRIATNESS
County
Illuminated / Non -Illuminated ?
Reface
Sign Dimensions
Type of Sign Being Installed
VALUATION
Wall Dimensions
Wall Elevation
Zoning
FEES
Sign Permit Fee (Plan Review) 65%
Sign Permit Fee (Remaining Fee) 35%
PAYMENTS
Www.mygov.us
Permits
LEGAL
Metroplace Addition 2nd Instl
Blk 6 Lot 3
Olive Garden #1497
VB Sprinkler
A-2/F-1
CC
Landon White
574-232-6933
NO
Tarrant
Illuminated
No
3.75' x 13.41'
Wall
4000
19.25' x 114.38'
South Elevation
CC - Community Commercial
TOTAL = $ 87.25
$ 56.71
$ 30.54
TOTAL = $ 87.25
Mister Sign Man (Josh & Mendi Tips)
Check on 05/31/2019 ($56.71)
Note: CK1812526
Mister Sign Man (Josh & Mendi Tips)
Check on 0812812019 ($30.54)
Note: CK3395
NOTICES
ALL work must be done in compliance with the CITY OF GRAPEVINE SIGN
ORDINANCE, SECTION 60.
City of Grapevine CODE OF ORDINANCES.
And the 2005 NATIONAL ELECTRICAL CODE.
In accordance with STATE LAW & CITY ORDINANCE, Illuminated signs must
be constructed, installed and wired by a State Licensed Electrical Sign
Contractor or State Licensed Master Electrician. Signs may also be constructed
MYGOVAS City of Grapevine I SIGN, ELECTRICAL I ESGN-19-2148 I Printed 08/28/19 at 1:58 p.m. Page 1 of 3
by a fabricator approved by a Nationally Recognized Testing Agency and
labeled accordingly.
READ AND SIGN
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT OT THE BEST
OF MY KNOWLEDGE AND THAT THE SAID WORK WILL BE DONE IN
CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN
COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN
REQUIREMENTS.
Signature
tgly?Its
Date
MYGOV.US City of Grapevine I SIGN, ELECTRICAL I ESGN-19-2148 I Printed 08/28/19 at 1:58 p.m. Page 2 of 3
ITALIAn mi i %-HEN
SITS
site enhancement services
Ph:1.800.599.7696
Fax: 1 . 574. 237. 6166
www.siteenhancementservices.com
PROVIDE
DISCONNECTOR
AT SIGN LOCATION
ALL CHANGES REQUIRE
APPROVAL
OF REVISED PLANS
APPROVED PLANS SHALL BE
KEPT ON JOBSITE ATALL TIMES
CONTRACTOR SHALL CALL FOR
INSPECTIONS:
(817) 410-3010
CONTRACTOR REGISTRATION
WILL BE REVOKED UPON
PERMIT EXPIRATION.
CITY APPROVED PLANS TO BE KEPT ON.
THE JOB SITE AT ALL TIMES
DATE: 161 ;L31 i5 BY: & ;;L .
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
ALL CHANGES MUST BE APPROVED
O
U
w
U
U.
U.
O
t-i
_
is'-5"all olgm. 30.01 OZ-
4N,G %4 x I U-G'
19--S'-9" x 13'-5" Wrll 01g1-.. 50.01 SF,
�2x 16'-0"
G
,74W
3'-9" x 13'-5" Wait Sign: 50.31 SF
CITY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
SHEET: OF:
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE.
CITY APPROVED PLANS TO BE KEPT ON
THE JOB SITE AT ALL TIMES
DATE: BY:
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
ALL CHANGES MUST BE APPROVED
0 Proposed Signage
0 Existing Signage
1
Site Plan
Store #1497
Sr S Ph: 1 . 800 . 599 .7696 1 Fax: 1 . 574 . 237 . 6166 1 www.siteenhancementservices.com Page 2 of 5
CITY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
SHEET: .OF:
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE.
EQ
CITY APPROVED PLANS TO BE KEPT ON j
THE JOB SITE AT ALL TI _
DATE: _ BY: n
BUILDING INSPECTION DIVISION: imwit
I
RELEASE DOES NOT APPLY TO CON�RUC,rinni �ni
:..
EASEMENTS OR PUBLIC RIGHT F-WA'v7�. '.
ALL CHANGES MUST BE AF'PRC IVED
Proposed: 50 SF Wall Sign
See pages 10 & 11 for sign details.
Existing: None
8T-5 3/8"
Rear Elevation
Store #1497
SE S Ph: 1 800 .599 .7696 1 Fax: 1 . 574 237 6166 1 www.siteenhancementservices.com Page 3 of 5
Y T
f�I
Y
Custom mansard roof mounting required.
OLIVE GARDEN NOTES
.063 WHT/BLKALUM BACKS
D40 ALUM RETURNS STAPLED 5"
K-LATH SCREWS II I
314'GEMINI WARM GREY TRIMCAP �
.177 WHITE SG10 FACES 4
MFGD. BY PLASTILITE rII1
SURFACEAPPLIED TRANSLUCENT
VINYL 3M 363"450 WARM GREY
OQivqap�.
GEMX41 LED'S
GEM TRIM, RETURNS, DETAILA
SCREWS, ANO BACKS
TO BE PMS 1C WARM GREY
eSAT
VINE NOTES
.063 WHTIBLK ALUM BACKS
_-
3n
11R'.050 ALUM STAPLED
RETURNS
K-LATH SCREWS
L50 -Wall Sian - 50.31
sa ft
1 3W STANDOFFS PAINTED
PMS 7533 BROWN
314' GEMINI TRIM CAP
SCALE: 1/2" = V-0"
PROVIDE
SURFACEAPPLIED TRANSLUCENT
VINYL 3M 3730.SD98 GREEN
GEMM71 LED'S
1
9
D I SC O N N ECTO R
-
.177 WHITE SG10FFACAAES
MFGD. BY PLASTILITE DETAIL B
AT SIGN LOCATION
GEM TRIM, RETURNS,
SCREWS, AND BACKS
TO 8E PMS 383C GREEN
ITALIAN KITCHEN NOTES
13'-5"
■
4'-3 3/8" O.C.
4'-3 3/8" O.C. 4'-3 3/8" O.C.
BENT.G63ALUM POP RNIT j
t
L � ■.( ■
TO BENT.090 ALUM
.090AWM REMOVEABLE
-
•
PANEL FOR SERVICING LEUS
3I4' CLEAR ACRYLIC
PUSH-THRU COPY W1 L
3730-5098 GREEN VINYL !
ON FACEAND PMS 383C '
GREEN PAINTED RETURNS
GEMM71 LED'S �
I
.090 ALUM FACE
DETAIL C
1 %" Aluminum Angle
Mountino Points
Vertical Weld to Frame
DIGITALLY PRINTED
VINYL TO MATCH
SCALE: 1/2" = V-0"
PMS 7533C BROWN
3M3730-5098
.
r GREEN VINYL
CITY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
TE<
VINE DETAIL
SHEET: OF:
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE.
3M 3730ur098
BRr(1
Warm Gray
3M 3fi30-0450
CITY APPROVED PLANS TO BE KEPT ON
THE JOB SITE AT ALL TIMES
OR TRIMCAP
FROM GEMINI FOR GREEN &
FROM EMI IF RGREEN&
GRAY TO BE DEVELOPED
(PART # NOTASSIGNED YET.)
DATE: BY:
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
ALL CHANGES MUST BEAPPROVED
L50 Wall Sign
1'-3"
1O"
-2 - --
. .090 ALUMN. FILLER
AND BACKS.-
SEE DETAIL B
TOGGLE SWITCH
ACCESS DOOR AS REO'D a �' • y '
PUT PRINTED LED SCHEMATIC r
ON BACK OF DOOR
SPACERS FOR VINE 2 -�
POWER SUPPLIES MOUNTED ' I,
BEHIND SERVICE DOOR
.125 ALUM. FACES
SEE DETAIL A - r
1/2" CARFLEX AND CONNECTOR - ;I
3/8" RIV-NUT
SEE DETAIL C _ r
A
10" DP FABRICATED ALUMINUM CABINET WITH 2" DP CAP ON FACE,
AKZO NOBLE PAINTED TEXTURED PMS 7533C BROWN TEXTURED
MICRO POWDERS PROPYLTEX 50. POWER SUPPLIES TO BE
ACCESSIBLE FROM REMOVABLE PANEL ON SIDE OF FABRICATED
CABINET
MOUNTING:
A) THRU-BOLT W/Ya"O THREADED ROD WITH
BLOCKING
B) TOGGLES OR LAGS ARE ONLY TO BE
USED IN EMERGENCY SfTVATbN5
r
"MULTI -TAP POWER SUPPLY
GEPS12-60U-NA
120V/277V-.65/.29 AMPS EA
THIS SIGN IS INTENDED TO 8E INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTS OF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER APPLICABLE LOCAL
CODES THIS INCLUDES PROPER GROUNDING
Page 4 of 5
Tetra® LED Systems
CUSTOMER INFORM• ATION
MATERIAL ESTIMATE
— SPECIAL INSTRUCTIONS
I I ESTIMATE FOR ONE SIDE OF SIGN ONLY
1) THE GRAPHICS BELOW ARE FOR REFERENIifONIM1d not be used for commercial quotation dnd without validation. The material estimates ddelras LED Systems
are based upon our engineering standards andormation provided pertaining to font. letter hght, can depth, face material, and any special iaettions provided by the customer.
Missing information will cause delays in deiy of estimate as well as affect product selectio quantities, application, and illumination.
2) LED MODULE PLACEMENT AND QUANnT-YABPaDXIMATION ONLThe sign manufacturemustverity module placement and quantity to ensure eadllumination.
3) Final material quantities for estimation purposetnd construction are the responsibility of thegri OEM.
A) All signs should be tested as complete unils(uding correct Tetrl power supply) before installatio(or acceptable color, illumination, intensity.& bctionality.
5) For detailed information and instructions refee the applicable Tetra® product found undeSignage at; •;.com
Can Depth Power Supply Location Illumination Total Amps (Priinary Total Watts (System) I Total Area
; :5 '' REMOTE I FACE / BACKLIT 1.3 Amps 106.92 Watts III 8.44 Sq Ft
Drwg #: 039583; 03
Tetra® MAX GEMX41;1
Tetra® miniMAX GEMM71;1
Tetra® miniMAX MS J GEMS71;1
MATERIAL LIST
GEMX41;1 81 Mod 41 Ft
LED
I
Module
GEMM71:1
18 Mod
7 Ft
GEMS71;1
114 Mod
46 Ft,
Power I
GEPS12.60j•NA
2 Ea
SLA
GEPS12;20
0 Ea
SUPPIY Ire
9409
80 Ft
Energy Useage
Choose one wir
192160005
24 Ea
12.67 Watts/Sq F
connector
191600041
24 Ea
End Caps
191600041
16 Ea
MATERIAL BREAKDL WN
GEMX41;1 Modules
-•I
O 10
LSO — — — + LI 11
VE 12
G 12 1
AR 14
DEN 22
W 1, ? fF"'
' _`1V'1 zZt, ,,=A ' U
I"
�4
IT-4-Se"
® Lighting S o I ut i o n TECH SUPPORT 888;694;3533 216;266;2891,Drawn By:
Tetra LED System:
EMAIL:TETRADRAWINGS-.GE.COM Checked By:
e
EAST CLEVELAND, OH 44112 1 E;FAX: 216 ; 359 ; 0075 Date:
M
GEMM71;1 Modules
IK 18
I
GEMS71:1 Modules
LEAVES 114
KO Drwg #: 039583; 03
3l20114 PAGE 1 OF 1
L50 Wall Sign
CITY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
SHEET: OF: _
RELEASE ODES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE Bl11 DM CODE OR ZONING ORDINANCE.
CITY APPROVED PLANS TO BE KEPT ON
THE JOB SITE AT ALL TIMES
DATE: BY:
BUS INSPECTION DIVISION:
PIS RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
ALL CHANGES MUST BE APPROVED
pis
Rev
Page 5 of 5