Loading...
HomeMy WebLinkAboutNSFR2020-3830Texas Commission on Environmental Quality Customer Service Inspection Certificate Name of PWS: City of Grapevine PWS 0 #: 2200013 1 Location of Service: I i aak rERGALE OR. —/ Reason for Inspection: New construction.............................................................................. C'3 Existing service where contaminant hazards are suspected ............ ❑ Major renovation or expansion of distribution facilities ..................... ❑ I tMAkk AAE;K(-A S , upon inspection of the private water distribution facilities connected to the aforementioned public water supply do hereby certify that, to the best of my knowledge: Compliance Non -Compliance (1) No direct connection between the public drinking water supply ❑ and a potential source of contamination exists. Potential sources of contamination are isolated from the public water system by an air gap or an appropriate backflow prevention assembly in accordance with Commission regulations. / (2) No cross -connection between the public drinking water supply and d ❑ a private water system exists. Where an actual air gap is not maintained between the public water supply and a private water supply, an approved reduced pressure principle backflow, prevention assembly is properly installed and a service agreement exists for annual inspection and testing by a certified backflow prevention assembly tester. (3) No connection exists which would allow the return of water used —/ Lty ❑ for condensing, cooling or industrial processes back to the public water supply. (4) No pipe or pipe fitting which contains more than 8.0% lead exists ❑ in private water distribution facilities installed on or after July 1, 1988 and prior to January 4, 2014. (5) Plumbing installed after January 4, 2014 bears the expected ❑ labeling indicating :50.25% lead content. If not properly labeled, please provide written comment. (6) No solder or flux which contains more than 0.2% lead exists in ❑ private water distribution facilities installed on or after July 1, 1988. 1 further certify that the following materials were used 'n the installation r the private water distribution facilities: Nr Service lines; Lead ❑ Copper PVC Other ❑ �Kl Solder; Lead ❑ Lead Free Solvent Weld ❑ Other ❑ I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information I have provided. Remarks: I Existing plumbing may have been installed without permits J inspections and therefore cannot be verified. It is impossible to verify compliance of existing plumbing which is covered by building construction. Signature of Inspector: Title: Date: 1121 /A Inspector �) License Number: Type of License: i Z— 3el0 Plumbing Inspector 0 Foms\TCEQ-20699\00-17-17 ,J1 1'go 2021 ENERGY CODE INSPECTION CERTIFICATION FORM Date: 07-08-21 Permit / Project Number: 20-3830 Project Name: SFR Address of Inspection: 1222 Terrace Drive Name of Company Performing Inspection: Lee Roberts inspections Name of Certified Inspector Performing Inspection: Lee Roberts ICC Energy Code Inspector Certification Number: 0840259 In accordance with State Law (Senate Bill 5 enacted by the 7711, Legislature of the State of Texas), I hereby certify that I have inspected the above referenced structure and that it complies with all energy code provisions prescribed by State of Texas laws and any amendments adopted by the State of Texas and / or the City of Grapevine. Signa u e Anspector Development Services Department The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (617) 410-3165 Fax (817) 410-3012 * www.grapevinetexas.gov O EORM=ENEFGYfA MLATEO\ ENEFGY COWL TiON Ym RP' 1-M.617