Loading...
HomeMy WebLinkAboutESGN2021-1234 8 2 DATE OF ISSUANCE: PERMIT # q0 a r SIGN PERMIT APPLICATION JOB ADDRESS: ,"p t"e, %1I f€ 5 KU / SUITE # ' 1 LOT: BLOCK: SUBDIVISION: NAME OF BUSINESS: ( Ra,,4 PHONE NUMBER: , � j SIGN CONTRACTOR (company name): `�! �J (OR ELECTRICAL SIGN CONTRACTOR) STATELICNSEREQUi�RED FOR Fr.FCruIrer, ciGN CONTRACTOR CURRENT MAILING ADDRESS: _f7Z - 2-s CITY/STATE/ZIP: _ % f E./ y PHONE NUMBER: 1 - 141X- �153 TYPE OF SIGN: FREESTANDING QWALL M UUNT..E4-• ANNER GRAND OPENING thru OTHER DESCRIPTION OF SIGN: tvlai SIGN DIMENSIONS: 5 N X b ` WALL DIME SIONS: ILLUMINATED? YES NO REFACE? YES NO ELEVATION: - `® **In accordance with STATE LAW & CITY ORDINANCE, illuminated signs must be constructed, installed and wired by a State Licensed Electrical Sign Contractor or a State Licensed Master Electrician. Signs may also be constructed by a fabricator approved by a Nationally Recognized Testing Agency and labeled accordingly** VALUATION OF SIGN: REQUIRED ATTACHMENTS: 1. A separate permit and 2 sets of drawings are required for each sign. For wall signs a separate permit application and plans may be submitted for each elevation. A minimum of 11 x 17 drawings must be submitted. All drawings must be legible. 2. Pole or ground signs require a site plan drawn to scale showing location of the sign. Pole sign structural drawings must be sealed by a State of Texas Registered Professional Engineer. Monument and Ground sign applications must include footing detail. 3. Show dimensions and distances to property lines. (Place asterisk on property line with line to sign location). 4. Detailed, dimensioned plans of sign showing graphics. Dimensioned full length building elevation showing sign or signs on building. Show dimensions of height & width of tenant space and or building. 5. Plan Review Fee, 65% of the permit fee is required when permit application is submitted. Balance due upon approval. If any other signs are on the property, give the number and the types 1 HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT THE SAID WORK WILL BE DONE IN CONFORMANCE WITH THE INFORMATION HEREIN SET FORTH AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODE REGULATING SIGN EMENTS. PRINT NAME: IL'V & DIAMAJ SIGNATURE: PH #: FAX#: EMAIL:_ bd CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL FOR OFFICE USE ONLY FUNCTIONAL TYPE: tad) pu A, o, STRUCTURAL TYPE: i APPROVED BY: DATE: ZIVI PERMIT FEE: PLAN REVIEW FEE: REMAINING FEE: O: FORMS\DSAPPLICATIONS\SIGNAPP.doc 6/412004-Rev:3105,5/06,2107,11109,111S GRAPEVINE March 16, 2022 Signs Assign 702 Shepherd Dr. #156 Garland, TX 75042 Expired Permit Application: 21-1233 and 21-1234, 3000 Grapevine Mills Pkwy (Acai Bowlz) Dear Applicant: Our records indicate that your company has expired permit applications that have not been issued. Failure to begin work within 180 days after permit issuance or allowing 180 days to pass between inspections will result in an expired permit. Once a permit has expired, the permit must be renewed and new fees paid. Permits which have expired for more than 30 days are subject to the issuance of citations. No future permits will be issued until the contractor resolves all expired permits. In order to reinstate your registration, vour expired permits must be re -applied for and obtain final inspection. Sincerely, Connie Cook Development Services Assistant Development Services Department The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3165 Fax (817)410-3012�Gv.aLEr ML rvz KG FRONT ELEVATION - 4 GRAPEV SCOPE OF WORK: MANUFACTURE AND INSTALL (1) ONE SET OF FRONT ILLUMINATED LED CHANNEL LETTER I" JEWELITE TRIM CAP BLACK ShikLL LE I-L- t-UH CLASS 2 LEDS & P YOS WHITE 3M VtNY LL COLOR 4*C� REMOTE TIVIPnN * SPELLING * CONTENT * MEASUREMENTS *COLORS * PLACEMENT 4" FABRICATED ALUMINUM LETTER RETURNS PAINTED BLACK PROVIDEE AT DISCONNECTO 4'f r TRIM CAP BLACK NON -CORROSIVE INSTALLATION HARDWARE: SEE DETAIL 3/16"THICK 07328 FACE LED DIODE MODULE WHITE (MIN. IS' LEADS) 3mm ALUPANEL BACKS PRIMARY POWER CONNECTS TO A TIMER 1 GROUNDED WALL PASS-THRU SEALED WATER 7I6 (SHOWN AS TYPICAL/ FRONT ELEVATION TO § E PM HAVE PASS THROUGH AT TOP OF LETTER) LOW VOLTAGE ELECTRONIC TRANSFORMER iFJ LOCATED IN INTERIOR WALL AREA INSIDE A SHE . S PROTECTIVE CASE BOX �-• L WATERPROOF FLEXIBLE CONDUIT FOR ffi`€..iT W,Y -HE fE UL LISTED AND APPROVED 20AMP IL ` �bRIZE ANY IN WOr 'WW DISCONNECT SWITCH T [ _-_ > � AL=`-:'fE �� ONE (1) SET - LANDLORD APPROVAL SCALE--3/8"=1' TE ALL TIMES REQUIRED BEFORE PRODUCTION DATE: r p 4325 WOOdbluff Dr. NAME Acai Bovirl� ' �.iYa 3E'VIC}e M�I�S DR4yV1t4G REV: 03 DATE: - DE IGN: a i IC t4 t� 4 ;iJV ` Mesquite, TX. 75150 Acai Bowls Relocate 030421 I'Iv APPLY� , L f y. I ADDRESS Grapevine, TX R1 03-11-21, y (903) 456-9638 ALESMAN: R2 Q3-ib-2i 0E `S O PUBLIC RIGHT-0=-'VAS` hgr Signs $ Wraps PHONE/EMAILIANGES MUST BE AFEM)"ED The sign and its system of components shall be securely fastened to tenant's sign band/fagade. Exposed and remainder of sign band must be free of holes and scratch marks. Patch and paint to match existing background. Installation must comply with building and fire codes. Must comply with it of Grapevine requirements. Includes permits & inspections, if applicable. Sign installation must be completed before or after mail hours. Sign contractor must sign in and out with security located at loading dock #6 adjacent to LEGOLAND by calling (972) 538-5921 for mail access. Contractor must have an updated certificate of insurance prior to install. Obtain certificate of insurance requirements from management office. CITY OF GRAPEVINE RELEASED FOR CONSTRUCTION SH FET OF: Cj";�7,',4,,-)T AUTHOROE ANYVVORK IN CONRU'- t �Vtl TH -1 CODE- OR ZONING OROINANCE. Y PLAA� .' - 'i- NS TO BE KEPT ON X- - --- - --- - - THE J10 B-- SITE AT ALL TIMES DATE: 4 It Z/;L I BUILDMNG �NSFECI-,ION 15kw- �,,4 RELEASE DOES NOT APPLY TO CONSTRUCT0N IN EASEMENITS OR PUBLIC RIGHT-OF-WAY, ALL CHANGES MUST BE APPROVED