HomeMy WebLinkAboutSFRA2022-0804CHRISTIAN BRIENZA - 6.800kW DC, 5.000kW AC SCOPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 503 RIDGE ROAD, GRAPEVINE, TX 76051. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES EQUIPMENT SUMMARY (17)QCELLS Q.PEAK DUO ML-G10+ 40OW MODULES (1)SOLAREDGE TECHNOLOGIES SE5000H-US (240V) INVERTER (17)SOLAREDGE P401 POWER OPTIMIZER APPLICABLE CODES • ELECTRIC CODE: NEC 2017 • FIRE CODE LOCAL: IFC 2015 • BUILDING CODE: IBC 2018 • RESIDENTIAL CODE: IRC 2018 GENERAL NOTES: 1. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE CODES. 2. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 3. ARC FAULT PROTECTION (AFCI) AND PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS) IS INTEGRATED WITH THE POWER OPTIMIZER IN ACCORDANCE WITH NEC 210.12 & 690.12 RESPECTIVELY. 4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NEC 690.41(B) S. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY -INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741ACCESSORY 6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 7. ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.31. 8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. INSTALLATION NOTES ELECTRICAL NOTES 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXOPSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES PER NEC 240. 6.AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250.122. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 690.31(A). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX SYSTEM VOLTAGE CORRRECTION IS PER NEC 690.7. IO.CONDUCTORS ARE SIZED PER NEC TABLE 310.15(B)(16) SEPARATE PLUMM04 MECHANIOAL, ELECTRICAL AND SIGN PERMITS SHALL BE REQUIRED 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4.ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 1-1/2" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ROOF ACCESS PATHWAYS AND SETBACKS: IFC 605.11.1.2.1 SIZE OF SOLAR PHOTOVOLTAIC ARRAY. EACH PHOTOVOLTAIC ARRAY SHALL BE LIMITED TO 150 FEET (45 720 MM) BY 150 FEET (45 720 MM). MULTIPLE ARRAYS SHALL BE SEPARATED BY A 3-FOOT-WIDE (914 MM) CLEAR ACCESS PATHWAY. IFC 60S.11.1.2.2 HIP ROOF LAYOUTS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3-FOOT-WIDE (914 MM) CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS AND MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE AT A LOCATION ON THE BUILDING CAPABLE OF SUPPORTING THE FIRE FIGHTERS ACCESSING THE ROOF. IFC 605.11.1.2.3 SINGLE -RIDGE ROOFS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE (914 MM) ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS AND MODULES ARE LOCATED. IFC 605.11.1.2.4 ROOFS WITH HIPS AND VALLEYS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL NOT BE LOCATED CLOSER THAN 18 INCHES (457 MM) TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL LENGTH, THE PANELS SHALL BE PERMITTED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. IFC 605.11.1.2.5 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL BE LOCATED NOT LESS THAN 3 FEET (914 MM) FROM THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS. -MKH i 5 ZUZZ .2 A -U -�Oql .h-v 15 kd PARCEL MAP PROJECT SITE a 503 Ridge Rd, Grapevine. TX 76051 a x a m ALL CHANGES REQUIRE O�APPROVAL REVISED PLANS AW COVED PLANS SHALL BE KEF T ON JOB§@9 D*ES STRUCTURAL ONLY F-15844 CON E O F T6�-�sI,11i *. ... ..... ....................... I AUL K: ZACHER INS T� (817) 4 wA'Q_l 1714QlTon ncUcTnATION rifff lift KE Uffw4mN",rPON -MR PALMETTO SOLAR V�* t 1505 KING ST, r CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 SHEET CATALOG AHJ: TX -CITY OF GRAPEVINE INDEX NO. DESCRIPTION T��.Q� T-01 COVER PAGE CrY OF lj�T kkt'GY1N T-02 NOTES RELEASED FO ; GQNFETRLtG ON T-03 SITE PLAN �uCE7, f o S-01 MOUNTING DET+DOES AAR LEASE N111 OT FL e CON FIXT 1fr T?i a i,E ! IUIL Otl E-01 STRINGING LAYOUT ecausWin ers S-02 STRUCTURCA LAPPROVED FLANS iG 8E KEPT -ON E-02 THREE LINE DIAGRAM THE J0 3 SITE AT ALICONF&AGE E-03 SPECIFICATJ��. E-04 EQUIPMENT ELEVATION VIEBUmbm�4LY PAPER SIZE: 17"X11" PL-01 WARNING PLAc5ur, at uut7 40TO CONSTRU+ITION IN KUb FA5FMFNT; OR F LIBLIC RIGHT-OF-WAY. SS SPEC SHEET(SALL CHANGES I! ice` BE_C-N00F;{ Ev: A EEI py T-01 NOTES SITE NOTES: 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.THE PV MODULESARECONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITHOUT STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. PROPERACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PERSECTION NEC 110.26. 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS: 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (13)(3)(C). 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 4. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 5.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 6. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES: 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE -COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUSTALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF -PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 5. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS AREBASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING. 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 3. VOLTAGE DROP LIMITED TO 3.0%. 4. DC WIRING LIMITED TO INVERTER FOOTPRINT. OPTIMIZER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR Ll- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE", OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.151. GROUNDING NOTES: 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND INVERTER MANUFACTURERS INSTRUCTIONS. 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURER INSTALLATION REQUIREMENTS. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.1191 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AH]. 9. GROUND -FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS DISCONNECTION AND OVER -CURRENT PROTECTION NOTES: 1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS). 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 5.OPTIMIZER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC -FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. INTERCONNECTION NOTES: FOR EXISTING STRUCTURAL ONLY F-15844 OF TF��slot * .: j yAUL K. ZACHER j L..: .. `.........a..........; 112�22� .p'.EXV06 30 2& 42 , �1 L�'• �CENSE.•'��r Palmettd PALMETTO SOLAR 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR 1. LOAD -SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] CIS A f,-IRApFI/INF 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOTRELIMEC f0RmMN8T4 kCTION 120% OF BUSBAR RATING [NEC 705.12(B)(2)(3)(b)]. 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURFSQEEMP F: THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOTZpE: N 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEEDWRAIMMrWIME E UlL$ BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)]. CITY APPROV _u EYl.AN5 I V bh KtF'I_ 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL KA I limit cI„� .10: 3 SITE AT AdIC]T��ES ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, Tilt-� COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12-E. v (B)(2)(3)(C)• UILDisYwht 5. FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)AYWMENT �QdW P"Y R SIZE: 17"X11" 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH OES JOT APPLY TO COtISTRUCTION IN ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 �'U HI-0E--W7. BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT A"HANC- APPR VI�`] ADDITIONAL FASTENING [NEC 705.12 (13)(5)] DATE: 3/4/2022 T-02 I SITE PLAN -CHRISTIAN BRIENZA - 6.800kW DC, 5.000kW AC NOTE:ROUTE PV WIRE INTERIOR IN ATTIC NOTE: 1.THE VISIBLE LOCKABLE, LABELED AC DISCONNECT (VLLD) IS LOCATED WITHIN 10FT OF ONCOR METER 2.THE AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 10FT OF ONCOR METER. METER NO:160 956 647LG ENGINEERING SCOPE OF WORK 1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. 2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT DRAWINGS, HE/SHE: a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN c. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN MODULE MANUFACTURER MODULE NO MODULE WATTAGE (INVERTER (INVERTER MANUFACTURER INVERTER QUANTITY �T 1V — ' PANEL COUNT DC SYSTEM SIZE 1 AC SYSTEM SIZE i i �r1 DRIVE WAY C 0U U U z W LL N 1'-6" 20'-8" — - 1 HANWHA Q CELLS AMERICA INC. QCELLS Q.PEAK DUO ML-G10+ 40OW 400 W SOLAREDGE TECHNOLOGIES SE5000H-US (240V) SOLAREDGE 1 17 6.800 KW DC SYSTEM 5.000 kW AC SYSTEM 3' FIRE SETBACK PHOTOVOLTAIC ARRAY ON ROOF DETACHED STRUCTURE PROPERTY LINE FENCE GATE (N) JUNCTION BOX CONDUIT RUN (N) PV INVERTER(EXTERIOR) (N)60A NON -FUSIBLE VISIBLE LOCKABLE LABELED DISCONNECT LOCATED WITH IN LOFT OF ONCOR METER (EXTERIOR) (N) MAIN SERVICE PANEL(INTERIOR) (E) ONCOR METER (EXTERIOR) FOR EXISTING STRUCTURAL ONLY F-15844 Palmetto's PALMETTO SOLAR 1505 KING ST, J CHARLESTON, SC 29405 3/4/2022 FLUSH VENTS (TYP) (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ESID: 10443720002209125 ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: O C cm n� rRA IN—E RELEASED uBMIS.TRUCTI-ON SHEET: OF: RELEASE DOES +i07 OONRLICT WITH THE Bl I 'AhWaquaa* rs' CITY APPROVbur rLANS lit KtrrI ON THE JOE SITE AT /MAINS DATE: BUILDIN(;(T .S �c'I6l FR SIZE: 17"Xil" RELEASE DOES 1PT APPLY TO CON.?RUCTION IN EASEMENTS P 1B 4T- )F-WA . ALL CHANGI A. PR�d DATE:3/4/2022 T-03 SR. NO AZIMUTH PITCH NO. OF ARRAY AREA MODULES (SQ. FT.) MP-01 1770 150 2 MP-02 1770 180 9 MP-03 2670 150 2 MP-04 870 150 2 MP -OS 3570 150 2 NOTE: PENETRATIONS ARE STAGGERED ....... ., .— ARRAY MP-02 (N) MAIN SERVICE PANEL(INTERIOR, (E) ONCOR METER (EXTERIOR) (N)60A NON-FUSIE VISIBLE LOCKAE LABELED DISCONNE LOCAT WITH IN LOFT OF ONO METER (EXTERIC (N) PV INVERTER(EXTE (N) JUNCTION SCALE:1"=10'-0" 42.3 190.2 42.3 42.3 42.3 SITE INFORMATION MAX ROOF TYPE ATTACHMENT ROOF FRAME TYPE FRAME OVER ATTACHMENT EXPOSURE SPACING SPAN HANG COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0" SHINGLE COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0" SHINGLE COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0" SHINGLE COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0" SHINGLE COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0" SHINGLE (E)BACK OF RESIDENCE ARRAY MP-03 —, i PHOTOVOLTAIC ARRAY ON ROOF ��— 6'-10" ARRAY MP-05 1'-6"r (E)FRONT OF RESIDENCE V-6" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 6-1" 1'-6" //__ 2 X 4 RAFTERS @ 2'-0"SPACING 110 V 10" ALUMINIUM RAILS SOLAREDGE OPTIMIZER ARRAY MP-04 MODULES DATA MODULE QCELLS Q.PEAK DUO ML-G10+ 40OW NUMBER OF MODULES 17 MODULE DIMS 73.97"x41.14"x1.25" MODULE WEIGHT 48.5 FOR EXISTING MODULE AREA(SF) 21.13 STRUCTURAL ONLY UNIT WEIGHT OF AREA 2.30 F-15844 DESIGN SPECIFICATION OF rF RISK CATEGORY II •.• . kgs��bit CONSTRUCTION SFD * : *i� .. ... ZONING RESIDENTIAL i F AUL K.Z¢CHE.. �/..: ... SNOW LOAD(ASCE 7-16) 5 PSF 1'1222 • �, p • EXF. 06130 2�42.• �1G'•.�CENSE.• �. EXPOSURE CATEGORY B �T.......... �G�� WINDSPEED(ASCE 7-16) 105 MPH PANEL HEIGHT OFF ROOF 6" LEGEND "PZSE advises that best practice in snow load areas is to install staggered attachments" PaImAm"I MS -MAIN SERVICE PANEL INV -INVERTER �' + PALMETTO SOLAR dI AC -AC DISCONNECT 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 UTILITY METER (855)339-1831 0- NABCEP#: PV-080720-027672 (N) -NEW ELECTRICAL LIC#:477031 (E) -EXISTING CUSTOMER INFORMATION -ROOF ATTACHMENT NAME: CHRISTIAN BRIENZA -VENT,ATTIC FAN(ROOF OBSTRUCTION) — -CONDUIT ADDRESS: 503 RIDGE ROAD, QCELLS Q.PEAK DUO GRAPEVINE, TX 76051 ML-G10+ 40OW MODULES 32.936385,-97.090502 APN:007-02-234 7 AHJ: TX -CITY OF GRAPEVINE cn-PWORA iNE - 3 -5 RELEASED ' fE:I IUN MOUNTING PATTERN SASHF-ET: OF:. RELEASE DOES R { g3hF CT carry THE EJ 3 •---+Ir --IF►— -1-- -ii 6ecausea�aa�rtyn�atters CiTr APPf'IROV :D mo_ TO BE KrmPT nib THE LO-18 SIT AIL 61' : . - MAX 72 l3LO E: MAXIMUM MOUNT SPACIN 7'X11" FZ ASE DOESBUILDWE _ _ _ ' T KUjRg iN MOUNT PATTERN: STAGG 4 11rAE _■ - .scyrl �'T -) urt pilau .. RIG111-U-'r'r'ry i'. ALL HARDWARE, INCLUDINA%IuCHANC�°`M V' -5 i�PPR ED AND RACKING, TO BE INSTAL Ff FFFt-- MANUFACTURER SPECIFICATIONS. DATE: 3/4/2022 S-01 NOTE: ROUTE PV WIRE INTERIOR IN ATTIC STRING CONFIGURATION BRANCH DETAILS A 9 MODULES l B 8 MODULES (N) MAIN SERVICE PANEL(INTERIOR) (E) ONCOR METER (EXTERIOR) (N)60A NON -FUSIBLE VISIBLE LOCKABLE LABELED DISCONNECT LOCATED WITH IN 10FT OF ONCOR METER (EXTERIOR) (N) PV INVERTER(EXTERIOR) (N) JUNCTION BOX (N)JUNCTION BOX SCALE:1/8" = 1'-0" (E)BACK OF RESIDENCE PHOTOVOLTAIC ARRAY ON ROOF FLUSH VENTS (TYP) (E)FRONT OF RESIDENCE Palmety® PALMETTO SOLAR 1505 KING ST, Y CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ESID:10443720002209125 ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE CITY C ObRAONNE RELEASED F ON SHEET: _ OF: RELEASE DOES NCT CONFLICT WITH THE BUILT INI's secause Q�aliry natters CITY APPROVED F'f_►" N3 TO ❑E KEPT aft, THE JOB ATE POUT DATE: t3y: BUILDING li 1� , pgC�� UCTIONIIN : 17"Xi l" RELEASE DOES N01 EASEMENTS 0 t VUOLK ruu" l -6FVVi6i. ALL CHANGESy3'�TPPROVW A DATE: 3/4/2022 E-Q 1 DEAD LOAD CALCULATIONS ATTACHMENT DETAIL- L-MOUNT TOTAL WEIGHT BOM QUANTITY LBS/UNIT (LBS) MODULES 17 48.5 824.50 MID -CLAMP 22 0.050 1.10 END -CLAMP 24 0.050 1.20 RAIL LENGTH 116 0.680 78.88 SPLICE BAR 2 0.360 0.72 L-MOUNT 31 0.7565 23.45 TOTAL WEIGHT OF THE SYSTEM (LBS) 929.85 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 359.26 WEIGHT PER SQ. FT.(LBS) 2.59 WEIGHT PER PENETRATION (LBS) 30.00 MID -CLAMP AND END -CLAMP ANATOMY VIL -LAMP END CLAMP MODULE I MODULE TO MODULE & MODULE TO RAIL MID CLAMP ASSEMBLY L MODULE FRAME — RAIL GROUNDING MID -CLAMP SCALE: NTS GROUNDING DETAILS GROUNDING LUG I \I T-BOLT SCALE: NTS RAIL TO RAIL FOR EXISTING STRUCTURAL ONLY F-15844 Palmettd PALMETTO SOLAR (� I ! 1505 KING ST, ) CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#: PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE SELF-DRILLI,"1N OF: RSB vq� I NFL ICT WITH THE BI IL N �. Pcause �raN ma er:s T APPROVED m THE JOE SITSIMA WUMTAIL DATE: Y- BUILDIN- : L ;IONER SIZE: 17"Xll" ELEASE DOES � APPLY TO CONSTRUCTION IN SCALE: NTS IRONRIDGE INTERNAL SPLICE EASEMENTcoOR PUBLIC RIGHT-JF-WAY. ALL CHANGI AIPPRQVE 6 DATE:3/4/2022 S-02 THREE LINE DIAGRAM: DC SYSTEM SIZE - 6800W, AC SYSTEM SIZE - 5000W (17)QCELLS Q.PEAK DUO ML-G10+ 40OW MODULES MODULE MANUFACTURER HANWHA Q CELLS AMERICA INC. 1 MAIN PANEL UPGRADE:REPLACE EXISTING MAIN (1)STRING OF (9) MODULES CONNECTED IN SERIES QCELLS Q.PEAK DUO ML G10+ 400W SERVICE PANEL WITH NEW 200/200A MAIN PANEL (1)STRING OF (8) MODULES CONNECTED IN SERIES MODULE NO NOTE: 1.THE VISIBLE LOCKABLE, LABELED AC DISCONNECT (VLLD) IS LOCATED WITHIN 10FT OF ONCOR METER 27HE AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN LOFT OF ONCOR METER. EXISTING 120/240V 1PH 3W 60HZ METER#:ONCOR M 160 956 647LG LUTILI GRID Ill (N)200A END FED MAIN PANEL I z D� LU t\ 2:< N %\] n n n 30A 2P PV La BREAKER A PV BREAKER AT THE OPPOSITE END OF EXISTING GROUNDING BUSBAR ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) SERVICE INFO 10' MAX - AC DISCONNECT SQUARE D SN: D222URB VISIBLE, LOCKABLE, LABELED 60A NON -FUSED, 240V NEMA 3R, UL LISTED (N)60A AC r4 DISCONNECT 1-3 UTILITY ONCOR - -tr—Eo AH) NAME TX -CITY OF GRAPEVINE MAIN SERVICE PANEL VOLTAGE 240V MAIN SERVICE PANEL BRAND UNKNOWN MAIN SERVICE PANEL 200 MAIN CIRCUIT BREAKER RATING 200 MAIN SERVICE PANEL LOCATION SOUTH SERVICE FEED SOURCE OVERHEAD MODULE WATTAGE INVERTER INVERTER MANUFACTURER INVERTER QUANTITY PANEL COUNT DC SYSTEM SIZE AC SYSTEM SIZE 400 W 1 SOLAREDGE TECHNOLOGIES SE5000H-US (240V) SOLAREDGE 1 SOLAREDGE TECHNOLOGIES SE5000H-US (240V) OUTPUT: 240 VAC, 21A 99% CEC WEIGHT EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT INVERTER-1 17 6.800 KW DC SYSTEM 5.000 kW AC SYSTEM 2 AC -N DC DC DISCO f I I I LOAD RATED DC DISCONNECT & AFCI (WITH RAPID SHUTDOWN COMPLIANCE) OCPD CALCULATIONS JUNCTION BOX 600V, NEMA 3 UL LISTED (N)JUNCTION BOX PV BREAKER CONNECTION 705.12(B)(2) INVERTER OVERCURRENT INVERTER O/P I X 1.25 PROTECTION=21xl.25xl=26.25A =>PV BREAKER = 30A ALLOWABLE BACKFEED 40A EE13 (N)QCELLS Q.PEAK DUO ML-G10+ 400W, 40OW MODULES PV MODULES 9 MODULES WIRED IN (1) SERIES OF 9 MODULES MT __--SOLAREDGE POWER OPTIMIZER P401 DC INPUT POWER - 400 WATTS I MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 11.75 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 6000 WATTS STC PER STRING MAXIMUM (N)QCELLS Q.PEAK DUO ML-G10+ 400W, 40OW MODULES PV MODULES 8 MODULES WIRED IN (1) SERIES OF 8 MODULES T+l � SOLAREDGE POWER OPTIMIZER P401 DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 11.75 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 6000 WATTS STC PER STRING MAXIMUM P a I m 40 41641: 0" PALMETTO SOLAR t 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ESID:10443720002209125 ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR Cff). nF PAPFIIIAIF RELEASED AM4MI19TRUCTION SHEET: CONDUIT SCHEDULE RELEASE DOES 4O TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND CONFLICT WITH THE Bl ILD;ft ��' 1 NONE (4) 10AWG PV WIRE/USE-2,CU NONE (1) 6AWG BARE COPPER, EGC CITY APPROVE-i FLANS 10 HL KL:Fyt C]N 2 3/4"EMT (4) 10AWG THHN/THWN-2,CU NONE (1) 10AWG THHN/THWN-2, EGC THE JOE SITffW RFAUU T GMM 3 3/4"EMT (2) 10AWG THHN/THWN-2,CU (1) 10AWG THHN/THWN-2,CU (1) 10AWG THHN/THWN-2, EGC 4 3/4"EMT (2) 10AWG THHN/THWN-2,CU (1) 10AWG THHN/THWN-2,CU (1) 10AWG THHN/THWN-2, EGC DATE: DRAFFE W:S.RAM SIZE: 17"Xll" BUILDING �T p))( ( ,PER 5 NONE (1) 6AWG BARE COPPER, EGC RELEASE DOES N IT APPLY TO CON RUCTION IN EASEMENTS B �iF-WAYREv: A `�• ALL CHAI Ai7PRnvitn DATE:3/4/2022� E-02 SPECIFICATIONS MODULE SPECIFICATION MODEL QCELLS Q.PEAK DUO ML-G10+ 40OW MODULE POWER @ STC 40OW OPEN CIRCUIT VOLTAGE: Voc 45.06V MAX POWER VOLTAGE: Vmp 37.59V SHORT CIRCUIT CURRENT: Isc 11.16A MAX POWER CURRENT: Imp 10.64A SYSTEM CHARACTERISTICS DC SYSTEM SIZE 680OW INVERTER STRING VOLTAGE:Vmp 380V MAX INVERTER SYSTEM VOLTAGE: Voc 480V MAX SHORT CIRCUIT CURRENT 30A OPERATING CURRENT 17.89A DC WIRE SIZING CALCULATIONS BASED ON THE FOLLOWING EQUATIONS>> REQUIRED CONDUCTOR AMPACITY: 125% X Isc(A) X #OF PARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% = MAX CURRENT PER 690.8(B)(1) TAG ID CORRECTED AMPACITY CALCULATIIONS: AMAPCITY X TEMPERATURE DERATE FACTOR X 1 COUDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) DERATE CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(1) < DERATED 2 CONDUCTOR AMPACITY AC WIRE SIZING CALCULATIONS BASED ON THE FOLLOWING EQUATIONS>> REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER 690.8(B)(1) TAG ID CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) 3 DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) < DERATED CONDUCTOR AMPACITY 4 INVERTER-1 SPECIFICATIONS MODEL SOLAREDGE TECHNOLOGIES SE5000H-US (240V) POWER RATING 5000W MAX OUTPUT CURRENT 21A I CEC WEIGHTED EFFICIENCY 99% MAX INPUT CURRENT 13.5A MAX DC VOLTAGE 480V OPTIMIZER CHARACTERISTICS MODEL P401 MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 60 VDC MAX INPUT CURRENT 11.75 ADC MAX OUTPUT CURRENT 15 ADC Fla I m ttv i PALMETTO SOLAR 6V E 1505 KING ST, d CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE CITY OF dWAOME RELEASED FQI ��i -rynt; ELECTRICAL CALCULATIONS SHEET: RELEASE UUE:ti NL 1 1Uj DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:900C CONFLICT WITH THE BUILnIP afew MI 6ecat se qualitymatters 1 X 15 XEQUIRED CONDUCTOR AMPACITY = 18.75A 40 CORRECTED AMPACITY CALCULATION3.20A DERATED 18.75A CONDUCTOR AMPACITY rib Fm-ANO M ��++ �r �- EtDI""T ON 1 X 15 X 1 = 15 X 11.251 1.25=�8.75A 40 I X , 0.71 , X 0.8 f = 22.72A 18.75A < I H 13 i 0E AT TI O N S nATF- d r : AC WIRE CALCULATIONS:- MATERIAUCOPPER & TEMPERATURE RATING:90'C BUILDING 1}+I PAPER SIZE: 17"X11" R5�aACc IZCIf"C Nil i "Jig-aliTION IN REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AqgW&X49*T8 O � I UHLK-: i IUH I -OF-" AY. 6crN21 X 1 = 21.0 X l 1.25 = 26.25A 40 X 0.87 X 1 , = 34.80A 26.25A < AL C AM-3 �T �'!O�r —REV: A 21 X { 1 + = 21.0 X 1 1.25 = 26.25A 40 X 0.87 X 1 = 34.80A 26.25A 34.80A DATE: 3/4/2022 E-03 I I EQUIPMENT ELEVATION VIEW BACKYARD 6' MAX SINGLE PHASE SERVICE M un 10' MAX GRID INVERTER-1 MAIN SERVICE PANEL _ - WINDOW xm.c mxvEns�on UTILITY AC DISCO INTERIOR EXTERIOR WALL INVERTER DIMENSIONS: HEIGHT: 17.7", WIDTH: 14.6", DEPTH: 6.8" AC DISCONNECT DIMENSIONS: HEIGHT: 14.88", WIDTH: 7.45", DEPTH: 4.87" EQUIPMENT MOUNTING HEIGHTS: APPROX 4 FEET - 6 FEET PANEL HEIGHT ON ROOF: 4 INCHES MAX WTEGRATED DC DISCO --- BACKYARD Esox t 8 pa I M e A.A. .0 PALMETTO SOLAR L i 1505 KING ST, d CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: S03 RIDGE ROAD, GRAPEVINE, TX 760SI 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR Cny r)F CtRAPMllNF I RE D SED I 'kI STM(NION SHEET: O RELEASE DOES F-OT. %Ayr CONFLICT WITH THE BUI -DI D O CITY APPROVED N THE JOB 51� L DATE: BpAf=.E':s-P� BUILDING IWeUCBT49LQd�I?ER SIZE: 17' Xll" RELEASE DOES NCT APPLY TO CONS -RUCTION IN EASEMENTS v �a -iF-WAY ALL CHANGE �� A IPRIOA DATE:3/4/2022 E-04 WARNING PLACARDS A WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION PER CODE: NEC 690.13 LABEL LOCATION CONDUIT, COMBINER BOX PER CODE: NEC690.31(D)(2) PHOTOVOLTAIC LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC690.13(B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO PV PANELS SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC690.56(C)(1)(A) INVERTER 1 LABEL LOCATION DC DISCONNECT PER CODE: NEC690.53 LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.54 WARNING POURER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER -CURRENT DEVICE LABEL LOCATION POINT OF INTERCONNECTION PER CODE: NEC 705.12(B)(3)(2) A WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION POINT OF INTERCONNECTION PER CODE: NEC705.12(C) LABEL LOCATION INVERTER PER CODE: NEC 690.56(C)(3) LABEL LOCATION : AC DISCONNECT LABEL LOCATION : AC DISCONNECT LABEL LOCATION : AC DISCONNECT WARNING://.\ POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN eme 503 RIDGE ROAD, GRAPEVINE, TX 76051 LABEL LOCATION SOLAR PHOTOVOLTAIC ARRAYS ON ROOF (N) JUNCTION BOX (N) PV INVERTER(EXTERIOR) (N)60A NON -FUSIBLE VISIBLE LOCKABLE LABELED DISCONNECT LOCATED WITH IN LOFT OF ONCOR METER (EXTERIOR) (N) MAIN SERVICE PANEL(INTERIOR) (E) ONCOR METER(EXTERIOR) Palmea® PALMETTO SOLAR t i 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE MY f bf� kpgk RELEASED P STRJ"ION. SERVICE PANEL PER CODE: NEC 705.10 SHEET: F: RELEASE DOES N )T I�E NOTES: �NBk{RffHTHE BUII 71 J ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL(;DTS S AALL BE 46ecaIlse AUalft n7atters RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVIGIT1 1V APPROVE[ PLANS I0 BE KEPT ON FASTENERS APPROVED BY THE LOCAL JURISDICTION THE JO�ITE AV CARDS DATE: _: BUILDING ' HWPER SIZE: 17"X11" RELEASE DOES NO - PPLY O ^.ONN RUCTION IN EASEMENTS CR P,¢U�BUC LiT{01 =WAY. ALL CHANGE. sc,, NOTED 1PpRO1fbA DATE:3/4/2022 PL-01 SPEC SHEET t�tvered try e - Dq THE IDEAL SOLUTION FOR: Rooftop mray6 on -_,dert al bdd'at95 Engineered in Germany MECHANICAL SPECIFICATION Rt1 4Ati%Xst tt,Vt1 �, ;- Format_ _ Weight Front Caner ��. ��_-�enS-_retlectro_n 1879mmx1045mmx32mm(tnclucFngframe)- 22.Okg _... __. __. 3.2 mat thermally pre -stressed Bless with - } technology _- _..___.-�__...__ •� ._.~ . _ Back Caves Cornpositefllm frerrle Blade enodlsed eluminium sllirs Qlar heH cells _ - ,!unction box t 53-101 m 2t60 mmx 15-18 Ma cl:nraarK lwsr . rw lutaro,pv_' trowtu essama ra. a rwrpro„t mzf v� aecewe6a .2021 YR Warranty Q CELLS woaucr. IN :r: ram.- geld Sacurty r BREAKING THE 21% EFFICIENCY BARRIER tfllll�Jl111 Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.4%. ,r t THE MOSTTHOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module marwtacturer to pass the most compre- hensive quality programme in the Industry: The new 'Quality Controlled PV' of the independent certification institute TUV Rheinland, INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, Whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE O Long-term yield security with Anti LID Technology, Art! PID Technology', Hot -Spat Protect and Traceable Quality Tra.Q14. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year l� [( linear performance warranty2. -APT lest cc•4`f-eccxd Qto IEC/TS 62804-1:2015, method A(-1500V, Bat+) 'See data Nest on rear for futher hloa, Minn. O CELLS C2 __ Protection class IP67, with bypass diodes _ _-0 Catfla 4mm2 Solar cable;(+) z1250mm,(-) z1250mm -- Connecter Staubil MC4; IP68 + +ta...ncr.tor+..n = I ELECTRICAL CHARACTERISTICS POWERCLASS 395 400 405 410 415 'N,iNIi40?P PERr-OPA4R.NCE7tT ST/,rdffARO TEST CONDITIONS. STC`(POWER TOLERANCE +IWi-OW) `. Powefat MPP^ Prsv ml 395 400 405 410 415 E Short Circuit Caaent' I, [All 11.13 11.16 _11.19 11.22 11.25 E Open Chcua Voltage+yx IV] 45.03 45.06 45.09 45.13 45.16 Current at MPP I„w [Al 10.58 10.64 10.70 10.76 10.82 gyottageatMPP Vrea M 37.32 37.59 37.85 38.11 38.37 EfNctencit II 1%) z20.1 _ _ a20.4 z20.6_ z20.9 z21.1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT- Po %r at It, PP P,.r IWI 296.4 300.1 303.9 307.6 3114 E Short Ciauit Currant 1. [A] 8.97 8.99 9.02 9.04 9.07 E Open afcuRVaRa9e Va IV] 42.46 _ 42A9 42.52 42.58 42.59 Ti Curran at MPP I_ (A) 8.33 8.36 8.43 8.48 8.53 voltageat MPP V,,, IV] 35.59 35.82 36.04 36.27 36.49 Weawrement tolererces Pw, t3%; le, Vac t5-%etSTC: 1000 Wlrn2, 25+2°C, AM LS eccadsrg to IEC 61)904-3.2800wfrnr, NMOT, spectrum AM 1.5 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE �"=b•,�..mw Atleest98%ofna6natpowerdur- Lr, T _r ____., o- S b'9 nr6trear.mn'eaft r-0.5% I . ....-.._...... ............. degrada ion Pa. year. At loot 93.5% ' Y r of nommai power up to 10 veers. At i w Isss:86%ofnwn�a1pormr upro r ' ------------ z5yeers. Q r All data wiihm �iemant toler, r ' w ancea FMlwa ti. In accordance .n am ..e r rsoo with uw warranty terms of the e00 Q CELL$ aele6 agaidsaaon of your wa1MJ014 respective country. Takes Typical rwd0a;, n-Wmsnce under low inadia-e condillortsM -part- toSTC condifiona (25'C, MO WIW TEMPERATURE COEFFICIENTS Temperature Coeff)clent of Ia� Temperature Coe(ficlent of P_ o y (%/Kj +0.04 Tampvmture Coefficient ofV; (! [%/Kj -0.27 1%/K] -0.34 Nominal Module Operating Temperatu* NMOT r•C] 43t3 PROPERTIES FOR SYSTEM DESIGN Maximum Syaem Voltage V,,, M 10DO PymoduladassifkasMn class ll Maxlmunl Reverse Curt��t 1. [A] 20 Fhe Rating based on ANSI/13761730 C/TYPE2 Max, Design Lasd,Push/Pul1 [Pal 36001 660 Permuted Modulo Temperature-40+C-+85'C Max. Test toad, Pueh/PUR [Pal 5400/4000 on Comiwous Duty QUALIFICATIONS AND CERTIFICATES cbrxra Pv-nx iEC 51215,2016: 1EC 61730:20M A Y Thrrdeu.Metm P6. xrve..r„ Hofzordai Wei DIN M 50390. OCWCer0.9wmfcn.Q_* , M9119 PACKAGING INFORMATION 1940ntm 1100mm 1220mm 751kg 28 pellets 24 pallets 32 modules Note:Insleaelion IrW-1lom nwsl be rdioved. Sae the IWARtIlk end opererrag marvel orenrdactour techrtcal service dapertmant for furtherIMurmation onapp-d Inalallahon and use of IW. product Hemrhe O CELLS GmbH Sonnenellee 17-2% D8766 Bittw6ald-Wolfan, Gerneny I TEL+49(0)34946699-234441 FAX +49IM4946699-230001 EMAILselea®q-oells IWES wnw.q-cda.com Engineered in Germany O CELLS Pa I mettd PALMETTO SOLAR 1505 KING ST, T� A CHARLESTON,SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 ILLUMINE i Recause quality matters MODULE SPEC SHEET DRAFTED BY:S.RAM PAPER SIZE: 17"X11" QC'ED BY:S.SELVAN SCALE: AS NOTED REV: A DATE: 3/4/2022 SS-Q 1 SPEC SHEET Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-Ul / SE5000H-USI/ SE6000H-US / SE760OH-US / SE10000H- 5 / 5tii4UUN-US 7 0 0 sotnria'Rf ,«NO p 0 I a a r � 12-2s YEAR 'I t, WARRANTY Optimized installation with HD -Wave technology Specifically designed to work with power optimizers / Record -breaking 99%weighted efficiency / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings f Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com 0 0 / UL1741 SA certified, for CPUC Rule 21 grid compliance / Small, lightweight, and easy to install both outdoors or indoors / Built-in module -level monitoring / Optional: Faster installations with built-in consumption metering (1%accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solar-=vz- Single Phase Inverter with HD -Wave Technology for North America SE300OH-US / SE380OH-US � SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT 3800 @ 240V 6" @ 240V 1 11400 @ 240V Rated AC Power Out ut 3000 5000 7600 1D000 VA P � 3300 @ 208V 5000 @ 20BV ? 10000 @ 208V t Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 f ' 10W0 11400 @ 240V 3306 @ 208V 5000 @ 208V _ _ 10000 @ 208V VA AC Output Voltage Min.-Nom: Max. ✓ i ✓ ✓ ✓ ✓ ✓ it ✓ I Vac (211 - 240 - 264) _ AC Output Voltage Min,-Nom,-Max. _ ✓ _ _ j _ i ✓ Vat (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 605"' ! Hz Maximum Continuous Output 125 16 21 25 — 32 I 42 I�47,5 A Current @240V t t Maximum Continuous Output 16 - 24 - - I 48.5 A Current Factor Pallmettd Power Factor 1 Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitorirg, Islanding Protection, Yes - _CountryCo_nfigurableThresholds `_�___-__ __--__•,—__._—__.—,__�-__ _._----._—__,.�_—. %,r INPUT PALMETTO SOLAR Maximum DC Power @240V 4650 1 5900 7750 9300 1 Iwo t55D0 17650 W 1505 KING ST, Max mum DC Power @208V I 5100 7750 15500 w CHARLESTON, SC 29405 3/4/2022 = - - (855)339-1831 Trforess, Ungrounded Yes —ansmer-1 ---•--------------------------•--•----------------------------•— NABCEP#: PV-080720-027672 MaalmumInput vbbge _ _ 480 Vdc ELECTRICAL LIC#:477031 Nominal DC Input Voltage = 60 i 400 Vct Maximum Input MaximuminpuiCurrent@2 85 3 195 13.5 13.5 - 27 05 Adc CUSTOMER INFORMATION Max. Input Short Circuit Current 45 1 Adc Reverse-PolarityProtection Yes NAME: CHRISTIAN BRIENZA Ground -Fault Isolation Detection 60010 Sensitivity _ I Maximum Inverter Efficiency 99 99.2 % Weighted 59 @ `4nV CEC Wei Efficie 99 % 9 r'4' 98.5 @ 208V Nighttime Power Consumption <2.5 I W ADDRESS: 503 RIDGE ROAD, 0)For onh regioralWningspL-asecon:art5olarEdgearpport GRAPEVINE, TX 76051 (2) A higher cuTTM soure may be used; the inverter vrdl limit its mpvt wane t to the values stated 32.936385,-97.090502 APN: 007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 i ILLUMINE Because r; uality rrratters INVERTER SPEC SHEET DRAFTED BY:S.RAM PAPER SIZE: 17"X11" QC'ED BY:S.SELVAN SCALE: AS NOTED REV: A DATE: 3/4/2022 SS-02 SPEC SHEET I Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6O00H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet ZigBee (optionap, Cellular (optionap Revenue Grade Metering, ANSI C12.20 OptionaF Consumption metering _ I Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection I Rapid Shutdown - NEC 2014, NEC Automatic Rapid Shutdown upon AC Grid Disconnect i 2017 and NEC 2020, 690.12 STANDARD COMPLIANCE _ Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 i Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B ! INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG I 1" Maximum A4-4 AWG DC Input Conduit Size / e of Strings / 1` Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG AWG Range Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 1450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 ! in / mm Weight with Safety Swmtch 22 / 10 25.1 / 11.4 1 26.2 / 11.9 38.8 / 17.6 j lb / kg Noise < 25 1 <50 dBA Cooling Natural Convection _ I _ Temperature Range -40 to +140 / -40 to +600 _ I 'F /'C _Operating Protection Rating NEMA 4X (Inverter with Safety Switch) ! (3) Inverter wdh Revenue Grade Meter P/N: SE o H-USOOOBNC4: Inverter vrth Revenue Grade Production and Consumption MeterP/N: SEx H-USOOOBNI4. For consumption metering, current trarnfonnm should be ordered s tately: SEACT0750--aWNA-20 or SEACT0750.400NA-20. 20 units per box (4) Full pcAvK up to a least �O C i 122'F; for power de -rating Wurriation refer to: httpsJ/w".solaredee.com/�,;iteVdef�il,!bLs! temperahne-derating-note-mi.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with Hb-wave technology and built-in RGM and Service Panel consumption monitoring Grid ITT LT L1 N L? Shielded CATSe cable e ►� L1 s - AC Conduit O solar&tgeTechnobgi z me All dghu reserved. SOIAREDGE, the S.ImEdge bgo, OFrOMED BY SOLAREDGf am vadcmmks m registered trademarks of SolerEdge Teduobgies, Im, All ROtIl1 etheriademada rt ioned heroin am vademarl3 of their respective owners. Date 12M20 W1/ENG NAM Subject to chane without notae. ■ Palmetto PALMETTO SOLAR 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 'rY Recause quality platters INVERTER SPEC SHEET DRAFTED BY:S.RAM QC'ED BY:S.SELVAN PAPER SIZE: 17"Xll" SCALE: AS NOTED REV: A DATE: 3/4/2022 SS-03 I SPEC SHEET Power Optimizer Frame -Mounted P370 IP4Kk P404 / P500 0 17' "2]5 'WA=TY Fast mount power optimizers with module -level optimization Specifcally designed to work with SolarEdge inverters Quicker installation - Power optimizers can be mounted in advance saving installation time I Up to 25% more energy I Superior efficiency (99.5%) solaredge.com MV 0 m O -o N m I Mitigates all types of modules mismatch -loss, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization I Next generation maintenance with module level monitoring I Module -level voltage shutdown for installer and firefighter safety s I - vji-L�,-4 o cin:a am& Power Optimizer Frame -Mounted P370 / P40 / P404 / P500 INPUT _ Rated Input DC Powerm 370 4DO 405 _ 1 SOD W Absolute Maximum Input Voltage 60 80 Vdc (Voc at lowest temperature) MPPT Operating Range 8-60 12.S - 80 8 - 80 Vdc Maximum Short Circuit Current aW 11 11,75 11 1 10.1 Adc Maximum Efficiency _ 99.5 % Weighted Efficiency 98.8 _ % Overvoltage Category _ 11 . OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED')O OPERATING SOLAREDGE INVERTER) Maximum Output Current — 15 Adc_ Maximum Output Voltage 4 60 85 —� 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FFE_IM SOLAREDGE INV: ATER OR SOLAREDGE INVERTER OFF) _ Safety Output Voltage per Power Optimizer �— 1 t 0.1 - T Vdc STANDARD COMPLIANCE _ EMC FCC 3art15 Class 8, IEC610OD-6-; IEC61OW-6-3 Safety v� JEC62109-1(class D safety,' UL1741 RoHS Yee Fire Safety VDE-AR-E 2100-712:20 13-05 INSTALLATION SPECIFICATIONS _ Maximum Allowed System Voltage 1000 _ Vdc 08x 5/5. Dimensions (W x L x H) 139x165x40/5.5x6.5x1.6 129x153x29.139x165x48/S.Sx6Sx1.9 mm/in 6.02 x 1.16 Weight (including cables) 775 / L7 65511.5 895 / 2.0 ! 870/ 1.9 gr/ Ib Input Connector MC4M Input Wire Length 0.16 / 0.52 m / ft Output Connector MC4 -- .-- — ..... Output Wire Length 12 / 3.9 m / ft Operating Temperature Ranger -40 to +85 / -40 to +185 'C / `F — Protection Rating fP68 / NEMA6P Relative Humidity 0 -100- (1) Rated power of the module at STC will not exceed the optim¢er'Rated Input DC Power'. Modules with up to +5% Parer tolerance are alloyed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +85'C / +185'F power de -rating is applied Refer to Power Opt(mizers Temperature De -Rating Technical Note for more details THREE PHASE PV SYSTEM DESIGN USING SINGLE PHASE SINGLE THREE �. SOLAREDGE HD-WAVEGRID 511Aported P3701 frame Minimum String Length P58 16 18 cro55 section (Power Optimizers) - - P4fY) 1 6 14 (13 with SE3IQ" 14 ` Maximum String Length (Power Optimizers) 25 50 50 Maximum Nominal Power per string 57M5250M 11250- 1275D W n _ _ �.—_. 1.1-2.2mm / Parallel Strings of Different Lengths Yes _J0.04-0.09in or Orientations �� (4) Itis not allowed to mix P404 with P370/P401/P5W in one suing L� (5) The P37otmovP500 cannot be used with the SE3K three phase inverter (available In some omuntries refer to Three Phase )reverter SBK-SE1DK datasheet) > 12mm / OA8in (6) Exacdy 10 when using SE3K-RW0108NN4 (7) If the inverters rated Ae power s maximum nominal power per string, then the maximum power per string will be able to reach up to the irgerter5 maiumum input DC power Refer to: htq)W/-sdamdge.com/sites/defau"es/se-power-optimizer-singfe-string-desgn-apprication-mte.pM (9) For SE27.6K SE55K SE82.8K: R is allowed to install up to 13,SD0W per string when 3 strings are connected to the inverter and when the maximum pourer difference between the strings is up to 2,000W: inverter max DC pawer:37,25OW O SoarEdge Ted wlo9iet. hoc AD right re—ved. SOLAREDGE the SolarEdgeb9q MWIRED BYSOtAREM.E art tradam9ft5 -get W tradern"la of SoWfdge TechwbGiK hx CE AN adwvadmM3 mall dhereina mdwrwla o1 tt respmt1% nvners Date 0WMI M-OO 12-MSu�mchange widan nobi (PD Palm,,,'Ltd PALMETTO SOLARu ` 1505 KING ST, r CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 4 a ILLUMINE *I A • Reeausertualftymatters OPTIMIZER SPEC SHEET DRAFTED BY:S.RAM PAPER SIZE: 17"X11" QC'ED BY:S.SELVAN SCALE: AS NOTED REV: A DATE:3/4/2022 SS-04 SPEC SHEET L-Mount I QMLM / OMLM-ST Elevated Water Seal Technologyo REM THIS EDGE TOWARDS ROOF RIDGE _ NO. 1 2 3 4 -5 DESCRIPTION CITY. FLASHING, ROUNDED CORNERS. 7' X 12' X .040", .438" HOLE, 5052, 1 MILL L-FOOT, 2' X 3.3W FOR .438" O.D. FASTENER, 2-1 /16" SLOT, 6061- 1 T6/600.5A-T61. MILL WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2'. 1 18-ass 12.00 •5 �' 1 '1 04 (4,20)YAND URAL 3.00 t J ��—E ON fi-ST 4.50 — ONLY 9,00 i 2.00 0.408 � � �l .00 99 -f-L-- N MILL, 3 + 1_ �0) 0 _FINISHES i f -- TITLE: i— C�iickMomitPV- .040 (2.50) (3,54) 275 4.foa QMLM & QML S : L MOUNT, 2- QMLM QMLM-ST uN1650TMERwtSESPEQ ER— SIZE I DRAWN BY: AAP REV ouacwsioru neE P+P'ic Es I . _ ra C6' A I DATE 4/4/2019 RL' �W "4ORAYING6"E C1ErtO,EfiYaFO.i!y(NO,Y.'1w./MeStODJCPONM�AR04 AtAWHDIFv41HdCME DO h*1 SCALE DRAWRK TWO P(hCE OEGiMA1. 3.79 'r,Mm, KRxR�IXiw0Uc5 r0u.Trv6fllaF1[a COF1'ItIC.M02011 QI.00MOWIfN THREEPLACEDEC•ML r.MA $CALF:7:4 �WFGM:0.7565 SfI�EIOrI 5 4 3 2 1 B17.2.3-44 Qu i c k Mount RESPECT THE ROOF Apr-2019 Rev 6 L-Mount Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket. WARNING: Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment. Locate, choose, and mark centers of rafters to be Carefully lift composition roofshingle with roofing Insert flashing between 1st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least 1'4" higher mounts will be placed. nails as required and backfill holes with aproved than the butt -edge of the 3rd course and lower sealant. See "Proper Flashing Placement" on next flashing edge is above the butt -edge of 1st course. page. Mark center for drilling. f attachingwith lag bolt use a M2" bit (Lag). Use a Ys" bit (ST) for attaching with the structural screw. Drill pilot hole into roof and rafter, taking care to drill square tothe roof. Do not use mount as a drill guide. Drill a 2" deep hole into rafter. Clean off any sawdust, and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to compatible with roofing materials. desired orientation. Prepare lag bolt or structural screw with sealing You are now ready for the rack of your choice. washer. Using a th-inch socket on an impact gun, Follow all the directions of the rack manufacturer drive prepared lag bolt through L-foot until L-foot as well as the module manufacturer. NOTE: Make can no longer easily rotate. DO NOT over -torque. sure top of L-Foot makes solid contactwith racking. NOTE: Structural screw can be driven with T-30 hex head bit. BI 7.2.3-44 Apr-2019 Rev 6 Paim 1""0 PALMETTO SOLAR 1505 KING ST, CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 I ILLU INEI ' Beaausequality inatter MOUNT SPEC SHEET DRAFTED BY:S.RAM PAPER SIZE: 17"X11" QC'ED BY:S.SELVAN SCALE: AS NOTED REV: A DATE:3/4/2022 SS-05 SPEC SHEET IRONRIDGE .62 XR10 Rail .46 } 3 Rai Section Proper ies I Property V ahie 1.37 ITotalCross-SectionalArea 0.363 in2. 1.'5 1 33 ISection Modulus IX-axisl 0.136 in IMoment of Inertia (X-axis) 0.124 in" IMoment of Inertia (Y-axis) 0.032 in 58 Torsional Constant 0.076 in3 j Polar Moment of Inertia 0.033 in 1.00 — Clear Part Black Part Description / Length Material Weight Number Number XR-10-132A XR-10-132B XR10, Rail 132" (11 Feet) 6000-Series 4.67lbs. XR-10-168A XR-10-168B XR10, Rail 168" (14 feet) Aluminum 5.95 tbs. XR-10-204A XR-10-204B XR10, Rail204" (17 Feet) 7.22lbs. qP Palmettd PALMETTO SOLAR�q t 1505 KING ST, w' CHARLESTON, SC 29405 3/4/2022 (855)339-1831 NABCEP#:PV-080720-027672 ELECTRICAL LIC#:477031 CUSTOMER INFORMATION NAME: CHRISTIAN BRIENZA ADDRESS: 503 RIDGE ROAD, GRAPEVINE, TX 76051 32.936385,-97.090502 APN:007-02-234 AHJ: TX -CITY OF GRAPEVINE UTILITY: ONCOR PRN NUMBER: PLO-46199 ILLUMINE i ' l3ecause quality matters RAIL SPEC SHEET v1.0 DRAFTED BY: S. RAM QC'ED BY:S.SELVAN PAPER SIZE: 17"Xll" SCALE: AS NOTED REV: A DATE:3/4/2022 SS-06 March 4, 2022 Palmetto Clean Technology 1505 King Street Ext. North Charleston, SC, 29405 structural ENGINEERS Subject: Structural Certification for Installation of Solar Panels Job Number: 22-02489 Client: Christian Brienza - PLO-46199 Address: 503 RIDGE ROAD, GRAPEVINE, TX 76051 Attn.: To Whom It May Concern PZSE's scope of work is limited to performing a structural evaluation of loading at the address above. After review, PZSE certifies that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and criteria shown below: Design Criteria: • Applicable Codes = 2018 IBC, ASCE 7-16, and NDS-18 � • Ground Snow Load = 5 psf; Roof Snow Load = 3.5 psf ARRAY 1, 3, 4, R..51psf ARRAY 2 • Basic Wind Speed =105 mph Exposure Category B 0 • Existing Roof Dead Load: ARRAY 1, 3, 4, & 5 = 10 psf; AR'201'8 �4�psf • Existing Roof Live Load: 20 psf; Existing Roof®rtion The existing structure is adequate to support the PVer IEBC §402.3 & 402.4. PV System Assembly The PV module assembly including all structural supporting components have been reviewed to be in accordance with the manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above. Installation Requirements The PV system shall be mounted flush to the existing roof surface. The contractor shall notify PZSE of any signs of damage to the roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is adequate to support the applied loads. The electrical engineering and system waterproofing shall be addressed by others. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 = 916.961.3965 www.pzse.com SERVICES Attn: Bu i Id i ng/I nspections Dept. Grapevine 200 S. Main St Grapevine, TX 76051 Please find enclosed a Permit Application and Documents for a solar panel Installation for the Address: 503 Ridge Rd Grapevine, TX 76051 Please let me know if you have any questions and/or if there is anything else you need. Thank you in advance for your help! Best, Victoria Anderson Permit Expeditor TITAN Services, LLC M: 817-752-9653 EXT: 103 Refs: Christian Brienza ENCLOSURES G® E: victoriasC@a. �m • 1 Electrical permit application • 1 Building permit application • 2 Plan -sets • 2 Engineer Letters • 1 Prepaid Envelope TITAN Services 17201-C Baker Blvd. Suite C1-3, Richland Hills, Tx. 76118 Office:901-248-01991 SERUIEES Attn: Building/Inspections Dept. Grapevine 200 S Main St Grapevine, TX 76051 Please find enclosed a Check for the permit fee for a solar panel Installation for the Address: 503 Ridge Rd Grapevine, TX 76051 Please let me know if you have any questions and/or if there is anything else you need. Thank you in advance for your help! Best, Victoria Anderson Permit Expeditor TITAN Services, LLC M: 817-752-9653 EXT: 103 E: Refs: Christian Brienza ENCLOSURES • 1Check $187.00 TITAN Services 17201-C Baker Blvd. Suite C1-3, Richland Hills, Tx. 76118 Office:901-248-01991