HomeMy WebLinkAboutSFRA2022-0804CHRISTIAN BRIENZA - 6.800kW DC, 5.000kW AC
SCOPE OF WORK
TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 503 RIDGE ROAD, GRAPEVINE, TX
76051. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL
SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES
EQUIPMENT SUMMARY
(17)QCELLS Q.PEAK DUO ML-G10+ 40OW MODULES
(1)SOLAREDGE TECHNOLOGIES SE5000H-US (240V) INVERTER
(17)SOLAREDGE P401 POWER OPTIMIZER
APPLICABLE CODES
• ELECTRIC CODE: NEC 2017
• FIRE CODE LOCAL: IFC 2015
• BUILDING CODE: IBC 2018
• RESIDENTIAL CODE: IRC 2018
GENERAL NOTES:
1. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC)
ARTICLE 690, ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE
RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE
CODES.
2. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED
PRIOR TO PARALLEL OPERATION.
3. ARC FAULT PROTECTION (AFCI) AND PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS) IS
INTEGRATED WITH THE POWER OPTIMIZER IN ACCORDANCE WITH NEC 210.12 & 690.12
RESPECTIVELY.
4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE
INVERTER IN ACCORDANCE WITH NEC 690.41(B)
S. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY -INTERACTIVE INVERTERS, AND SOURCE
CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS
REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C
FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL
1741ACCESSORY
6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC.
IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7.
7. ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT
COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND
LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY
INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.31.
8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO
SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS
REQUIRED BY THE NEC AND AHJ.
INSTALLATION NOTES
ELECTRICAL NOTES
1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS
SUNLIGHT RESISTANT PER NEC 310.10(D).
2.CONDUCTORS EXOPSED TO WET LOCATIONS SHALL BE
SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C).
3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN
2%.
4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS
OTHERWISE NOTED.
5.BREAKER/FUSE SIZES PER NEC 240.
6.AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC
250.122.
7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON
NEC 690.31(A).
8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON
NEC 310.15(B)(2).
9.MAX SYSTEM VOLTAGE CORRRECTION IS PER NEC 690.7.
IO.CONDUCTORS ARE SIZED PER NEC TABLE 310.15(B)(16)
SEPARATE PLUMM04 MECHANIOAL,
ELECTRICAL AND SIGN PERMITS
SHALL BE REQUIRED
1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR
MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED.
2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR.
3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER.
4.ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY.
5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'.
6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 1-1/2" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING).
7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS.
ROOF ACCESS PATHWAYS AND SETBACKS: IFC 605.11.1.2.1 SIZE OF SOLAR PHOTOVOLTAIC ARRAY.
EACH PHOTOVOLTAIC ARRAY SHALL BE LIMITED TO 150 FEET (45 720 MM) BY 150 FEET (45 720 MM). MULTIPLE ARRAYS SHALL BE SEPARATED BY A 3-FOOT-WIDE (914
MM) CLEAR ACCESS PATHWAY.
IFC 60S.11.1.2.2 HIP ROOF LAYOUTS.
PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3-FOOT-WIDE (914 MM)
CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS AND MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE AT A
LOCATION ON THE BUILDING CAPABLE OF SUPPORTING THE FIRE FIGHTERS ACCESSING THE ROOF.
IFC 605.11.1.2.3 SINGLE -RIDGE ROOFS.
PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE (914 MM)
ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS AND MODULES ARE LOCATED.
IFC 605.11.1.2.4 ROOFS WITH HIPS AND VALLEYS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL NOT BE
LOCATED CLOSER THAN 18 INCHES (457 MM) TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS
ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL LENGTH, THE PANELS SHALL BE PERMITTED TO BE PLACED DIRECTLY ADJACENT TO THE
HIP OR VALLEY.
IFC 605.11.1.2.5 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS.
PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL BE LOCATED NOT LESS THAN 3 FEET (914 MM) FROM THE RIDGE IN ORDER TO ALLOW FOR FIRE
DEPARTMENT SMOKE VENTILATION OPERATIONS.
-MKH i 5 ZUZZ .2 A -U -�Oql .h-v 15 kd
PARCEL MAP
PROJECT SITE a
503 Ridge Rd,
Grapevine. TX 76051
a
x
a
m
ALL CHANGES REQUIRE
O�APPROVAL
REVISED PLANS
AW COVED PLANS SHALL BE
KEF T ON JOB§@9 D*ES
STRUCTURAL ONLY
F-15844
CON
E O F T6�-�sI,11i
*. ...
..... .......................
I AUL K: ZACHER
INS T�
(817) 4 wA'Q_l
1714QlTon ncUcTnATION
rifff lift KE Uffw4mN",rPON -MR
PALMETTO SOLAR V�* t
1505 KING ST, r
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
SHEET CATALOG
AHJ: TX -CITY OF GRAPEVINE
INDEX NO. DESCRIPTION T��.Q�
T-01 COVER PAGE CrY OF lj�T kkt'GY1N
T-02 NOTES RELEASED FO ; GQNFETRLtG ON
T-03 SITE PLAN �uCE7, f o
S-01 MOUNTING DET+DOES AAR LEASE N111 OT FL
e
CON FIXT 1fr T?i a i,E ! IUIL Otl
E-01 STRINGING LAYOUT ecausWin ers
S-02 STRUCTURCA LAPPROVED FLANS iG 8E KEPT -ON
E-02 THREE LINE DIAGRAM THE J0 3 SITE AT ALICONF&AGE
E-03 SPECIFICATJ��.
E-04 EQUIPMENT ELEVATION VIEBUmbm�4LY
PAPER SIZE: 17"X11"
PL-01 WARNING PLAc5ur, at uut7 40TO CONSTRU+ITION IN
KUb FA5FMFNT; OR F LIBLIC RIGHT-OF-WAY.
SS SPEC SHEET(SALL CHANGES I! ice` BE_C-N00F;{ Ev: A
EEI py T-01
NOTES
SITE NOTES:
1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.
2.THE PV MODULESARECONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY
INTERACTIVE SYSTEM WITHOUT STORAGE BATTERIES.
3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR
BUILDING ROOF VENTS.
4. PROPERACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL
EQUIPMENT WILL BE PROVIDED AS PERSECTION NEC 110.26.
5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE
WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE
ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.
EQUIPMENT LOCATIONS:
1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.
2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED
OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15
(B)(2)(A) AND 310.15 (13)(3)(C).
3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO
NEC 690.34.
4. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT
WITHIN SIGHT OF THE AC SERVICING DISCONNECT.
5.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING
TO NEC APPLICABLE CODES.
6. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE
WHEN APPROPRIATE.
STRUCTURAL NOTES:
1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE -COMPLIANT
INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,
AND RAILS MUSTALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE
ARRAY/SUBARRAY, ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS.
2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF
ROOF -PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS.
3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETED AND SEALED W/ APPROVED
CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR.
4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN
DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.
5. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST
THE ROOF FRAMING MEMBERS.
WIRING & CONDUIT NOTES:
1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT
AND WIRE SPECIFICATIONS AREBASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT
MEANT TO LIMIT UP -SIZING.
2. CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.
3. VOLTAGE DROP LIMITED TO 3.0%.
4. DC WIRING LIMITED TO INVERTER FOOTPRINT. OPTIMIZER WIRING SYSTEMS SHALL BE
LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS.
5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR Ll- BLACK PHASE B OR
L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE",
OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS
THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.151.
GROUNDING NOTES:
1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND
GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE.
2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC
TABLE 250.122.
3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED
GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).
4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND
INVERTER MANUFACTURERS INSTRUCTIONS.
5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN
MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED,
MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES
PER THE MANUFACTURER INSTALLATION REQUIREMENTS.
6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE
REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER
MODULE.
7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR
MARKED GREEN IF #4 AWG OR LARGER [NEC 250.1191
8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50
THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING
ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AH].
9. GROUND -FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE
FIRE HAZARDS
DISCONNECTION AND OVER -CURRENT PROTECTION NOTES:
1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED
THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED
"LINE SIDE" (TYPICALLY THE UPPER TERMINALS).
2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND
BE A VISIBLE -BREAK SWITCH
3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID
SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN
ACCORDANCE WITH 690.12(A) THROUGH (D).
4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240.
5.OPTIMIZER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN
ACCORDANCE WITH NEC 110.3(B).
6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC -FAULT CIRCUIT PROTECTION
ACCORDING TO NEC 690.11 AND UL1699B.
INTERCONNECTION NOTES:
FOR EXISTING
STRUCTURAL ONLY
F-15844
OF TF��slot
* .:
j yAUL K. ZACHER j
L..: .. `.........a..........;
112�22�
.p'.EXV06 30 2& 42 ,
�1 L�'• �CENSE.•'��r
Palmettd
PALMETTO SOLAR
1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
1. LOAD -SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] CIS A f,-IRApFI/INF
2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOTRELIMEC f0RmMN8T4 kCTION
120% OF BUSBAR RATING [NEC 705.12(B)(2)(3)(b)].
3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURFSQEEMP F:
THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOTZpE: N
120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEEDWRAIMMrWIME E UlL$
BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC
705.12(B)(2)(3)]. CITY APPROV _u EYl.AN5 I V bh KtF'I_
4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL KA I limit cI„� .10: 3 SITE AT AdIC]T��ES
ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, Tilt-�
COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12-E. v
(B)(2)(3)(C)• UILDisYwht
5. FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)AYWMENT
�QdW P"Y R SIZE: 17"X11"
6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH OES JOT APPLY TO COtISTRUCTION IN
ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 �'U HI-0E--W7. BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT A"HANC- APPR VI�`]
ADDITIONAL FASTENING [NEC 705.12 (13)(5)] DATE: 3/4/2022 T-02
I
SITE PLAN -CHRISTIAN BRIENZA - 6.800kW DC, 5.000kW AC
NOTE:ROUTE PV WIRE INTERIOR IN ATTIC
NOTE:
1.THE VISIBLE LOCKABLE, LABELED AC DISCONNECT (VLLD) IS
LOCATED WITHIN 10FT OF ONCOR METER
2.THE AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL
WITHIN 10FT OF ONCOR METER.
METER NO:160 956 647LG
ENGINEERING SCOPE OF WORK
1. ILLUMINE INDUSTRIES INC. HAS ONLY
PROVIDED DRAFTING SERVICES FOR THE
PERMIT DRAWINGS. NO ACTUAL ENGINEERING
WORK, ENGINEERING REVIEW OR ENGINEERING
APPROVAL HAS BEEN CONDUCTED BY ILLUMINE
INDUSTRIES INC UNLESS NOTED OTHERWISE.
2. WHEN A PROFESSIONAL ENGINEER APPROVES
AND SEALS THE DESIGN FOR COMPONENTS OF
THEIR RESPECTIVE DISCIPLINE
(STRUCTURAL/ELECTRICAL) SHOWN ON THESE
PERMIT DRAWINGS, HE/SHE:
a. TAKES FULL DIRECT CONTROL OF THE
ENGINEERED DESIGN
b. IS GIVEN ACCESS TO PERSONALLY
SUPERVISE AND RECTIFY ANY ASPECT OF
THE ENGINEERED DESIGN
c. HAS FULLY ACCEPTED RESPONSIBILITY
FOR THE ENGINEERED DESIGN
MODULE MANUFACTURER
MODULE NO
MODULE WATTAGE
(INVERTER
(INVERTER MANUFACTURER
INVERTER QUANTITY
�T
1V — ' PANEL COUNT
DC SYSTEM SIZE
1
AC SYSTEM SIZE
i
i
�r1
DRIVE WAY
C
0U
U
U z W
LL N
1'-6"
20'-8" — -
1
HANWHA Q CELLS AMERICA INC.
QCELLS Q.PEAK DUO ML-G10+ 40OW
400 W
SOLAREDGE TECHNOLOGIES SE5000H-US
(240V)
SOLAREDGE
1
17
6.800 KW DC SYSTEM
5.000 kW AC SYSTEM
3' FIRE SETBACK
PHOTOVOLTAIC ARRAY ON ROOF
DETACHED STRUCTURE
PROPERTY LINE
FENCE
GATE
(N) JUNCTION BOX
CONDUIT RUN
(N) PV INVERTER(EXTERIOR)
(N)60A NON -FUSIBLE VISIBLE LOCKABLE
LABELED DISCONNECT LOCATED
WITH IN LOFT OF ONCOR METER (EXTERIOR)
(N) MAIN SERVICE PANEL(INTERIOR)
(E) ONCOR METER (EXTERIOR)
FOR EXISTING
STRUCTURAL ONLY
F-15844
Palmetto's
PALMETTO SOLAR
1505 KING ST, J
CHARLESTON, SC 29405 3/4/2022
FLUSH VENTS (TYP) (855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ESID: 10443720002209125
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: O C
cm n� rRA IN—E
RELEASED uBMIS.TRUCTI-ON
SHEET: OF:
RELEASE DOES +i07
OONRLICT WITH THE Bl I 'AhWaquaa* rs'
CITY APPROVbur rLANS lit KtrrI ON
THE JOE SITE AT /MAINS
DATE:
BUILDIN(;(T .S �c'I6l FR SIZE: 17"Xil"
RELEASE DOES 1PT APPLY TO CON.?RUCTION IN
EASEMENTS P 1B 4T- )F-WA .
ALL CHANGI A. PR�d
DATE:3/4/2022 T-03
SR. NO AZIMUTH PITCH NO. OF ARRAY AREA
MODULES (SQ. FT.)
MP-01 1770 150 2
MP-02 1770 180 9
MP-03 2670 150 2
MP-04 870 150 2
MP -OS 3570 150 2
NOTE: PENETRATIONS ARE STAGGERED
....... ., .—
ARRAY MP-02
(N) MAIN SERVICE
PANEL(INTERIOR,
(E) ONCOR METER
(EXTERIOR)
(N)60A NON-FUSIE
VISIBLE LOCKAE
LABELED DISCONNE
LOCAT
WITH IN LOFT OF ONO
METER (EXTERIC
(N) PV INVERTER(EXTE
(N) JUNCTION
SCALE:1"=10'-0"
42.3
190.2
42.3
42.3
42.3
SITE INFORMATION
MAX ROOF TYPE ATTACHMENT ROOF FRAME TYPE FRAME OVER
ATTACHMENT EXPOSURE SPACING SPAN HANG
COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0"
SHINGLE
COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0"
SHINGLE
COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0"
SHINGLE
COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0"
SHINGLE
COMPOSITION L-MOUNT ATTIC 2 X 4 RAFTERS 2'-0" 6'-0"
SHINGLE
(E)BACK OF RESIDENCE ARRAY MP-03 —,
i PHOTOVOLTAIC ARRAY ON ROOF
��— 6'-10"
ARRAY MP-05
1'-6"r
(E)FRONT OF RESIDENCE
V-6"
2'-0"
2'-0"
2'-0"
2'-0"
2'-0"
6-1"
1'-6" //__ 2 X 4 RAFTERS @ 2'-0"SPACING
110
V
10"
ALUMINIUM RAILS
SOLAREDGE OPTIMIZER
ARRAY MP-04
MODULES DATA
MODULE QCELLS Q.PEAK DUO
ML-G10+ 40OW
NUMBER OF MODULES 17
MODULE DIMS 73.97"x41.14"x1.25"
MODULE WEIGHT 48.5
FOR EXISTING
MODULE AREA(SF) 21.13
STRUCTURAL ONLY
UNIT WEIGHT OF AREA 2.30 F-15844
DESIGN SPECIFICATION OF rF
RISK CATEGORY II •.• . kgs��bit
CONSTRUCTION SFD * : *i�
.. ...
ZONING RESIDENTIAL i F AUL K.Z¢CHE..
�/..: ...
SNOW LOAD(ASCE 7-16) 5 PSF 1'1222 • �,
p • EXF. 06130 2�42.•
�1G'•.�CENSE.• �.
EXPOSURE CATEGORY B �T.......... �G��
WINDSPEED(ASCE 7-16) 105 MPH
PANEL HEIGHT OFF ROOF 6"
LEGEND "PZSE advises that best practice
in snow load areas is to install
staggered attachments" PaImAm"I
MS -MAIN SERVICE PANEL
INV -INVERTER �' +
PALMETTO SOLAR dI
AC -AC DISCONNECT 1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
UTILITY METER (855)339-1831
0-
NABCEP#: PV-080720-027672
(N) -NEW ELECTRICAL LIC#:477031
(E) -EXISTING CUSTOMER INFORMATION
-ROOF ATTACHMENT NAME: CHRISTIAN BRIENZA
-VENT,ATTIC FAN(ROOF OBSTRUCTION)
— -CONDUIT ADDRESS: 503 RIDGE ROAD,
QCELLS Q.PEAK DUO GRAPEVINE, TX 76051
ML-G10+ 40OW
MODULES 32.936385,-97.090502
APN:007-02-234
7
AHJ: TX -CITY OF GRAPEVINE
cn-PWORA iNE
- 3 -5 RELEASED ' fE:I IUN
MOUNTING PATTERN SASHF-ET: OF:.
RELEASE DOES R
{ g3hF CT carry THE EJ 3
•---+Ir --IF►— -1-- -ii 6ecausea�aa�rtyn�atters
CiTr APPf'IROV :D mo_ TO BE KrmPT nib
THE LO-18 SIT AIL
61' : .
- MAX 72 l3LO E:
MAXIMUM MOUNT SPACIN 7'X11"
FZ ASE DOESBUILDWE _ _ _ ' T KUjRg iN
MOUNT PATTERN: STAGG 4 11rAE _■ -
.scyrl �'T -) urt pilau .. RIG111-U-'r'r'ry i'.
ALL HARDWARE, INCLUDINA%IuCHANC�°`M V' -5 i�PPR ED
AND RACKING, TO BE INSTAL Ff FFFt--
MANUFACTURER SPECIFICATIONS. DATE: 3/4/2022 S-01
NOTE: ROUTE PV WIRE INTERIOR IN ATTIC
STRING CONFIGURATION
BRANCH DETAILS
A 9 MODULES
l B 8 MODULES
(N) MAIN SERVICE
PANEL(INTERIOR)
(E) ONCOR METER
(EXTERIOR)
(N)60A NON -FUSIBLE
VISIBLE LOCKABLE
LABELED DISCONNECT
LOCATED
WITH IN 10FT OF ONCOR
METER (EXTERIOR)
(N) PV INVERTER(EXTERIOR)
(N) JUNCTION BOX
(N)JUNCTION BOX
SCALE:1/8" = 1'-0"
(E)BACK OF RESIDENCE
PHOTOVOLTAIC ARRAY ON ROOF
FLUSH VENTS (TYP)
(E)FRONT OF RESIDENCE
Palmety®
PALMETTO SOLAR
1505 KING ST, Y
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ESID:10443720002209125
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
CITY C ObRAONNE
RELEASED F ON
SHEET: _ OF:
RELEASE DOES NCT
CONFLICT WITH THE BUILT INI's
secause Q�aliry natters
CITY APPROVED F'f_►" N3 TO ❑E KEPT aft,
THE JOB ATE POUT
DATE: t3y:
BUILDING li 1� , pgC�� UCTIONIIN : 17"Xi l"
RELEASE DOES N01
EASEMENTS 0 t VUOLK ruu" l -6FVVi6i.
ALL CHANGESy3'�TPPROVW A
DATE: 3/4/2022 E-Q 1
DEAD LOAD CALCULATIONS
ATTACHMENT DETAIL- L-MOUNT
TOTAL WEIGHT
BOM
QUANTITY
LBS/UNIT
(LBS)
MODULES
17
48.5
824.50
MID -CLAMP
22
0.050
1.10
END -CLAMP
24
0.050
1.20
RAIL LENGTH
116
0.680
78.88
SPLICE BAR
2
0.360
0.72
L-MOUNT
31
0.7565
23.45
TOTAL WEIGHT OF THE SYSTEM (LBS) 929.85
TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 359.26
WEIGHT PER SQ. FT.(LBS) 2.59
WEIGHT PER PENETRATION (LBS) 30.00
MID -CLAMP AND END -CLAMP ANATOMY
VIL
-LAMP END CLAMP
MODULE
I
MODULE TO MODULE & MODULE TO RAIL
MID CLAMP
ASSEMBLY
L
MODULE
FRAME
— RAIL
GROUNDING MID -CLAMP
SCALE: NTS
GROUNDING DETAILS
GROUNDING LUG
I \I
T-BOLT
SCALE: NTS
RAIL TO RAIL
FOR EXISTING
STRUCTURAL ONLY
F-15844
Palmettd
PALMETTO SOLAR (� I !
1505 KING ST, )
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#: PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
SELF-DRILLI,"1N OF:
RSB vq� I
NFL ICT WITH THE BI IL N �.
Pcause �raN ma er:s
T APPROVED
m THE JOE SITSIMA WUMTAIL
DATE: Y-
BUILDIN- : L ;IONER SIZE: 17"Xll"
ELEASE DOES � APPLY TO CONSTRUCTION IN
SCALE: NTS IRONRIDGE INTERNAL SPLICE EASEMENTcoOR PUBLIC RIGHT-JF-WAY.
ALL CHANGI AIPPRQVE
6
DATE:3/4/2022 S-02
THREE LINE DIAGRAM: DC SYSTEM SIZE - 6800W, AC SYSTEM SIZE - 5000W
(17)QCELLS Q.PEAK DUO ML-G10+ 40OW MODULES MODULE MANUFACTURER HANWHA Q CELLS AMERICA INC. 1 MAIN PANEL UPGRADE:REPLACE EXISTING MAIN
(1)STRING OF (9) MODULES CONNECTED IN SERIES QCELLS Q.PEAK DUO ML G10+ 400W SERVICE PANEL WITH NEW 200/200A MAIN PANEL
(1)STRING OF (8) MODULES CONNECTED IN SERIES MODULE NO
NOTE:
1.THE VISIBLE LOCKABLE, LABELED AC DISCONNECT (VLLD) IS
LOCATED WITHIN 10FT OF ONCOR METER
27HE AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL
WITHIN LOFT OF ONCOR METER.
EXISTING 120/240V 1PH 3W
60HZ
METER#:ONCOR
M 160 956 647LG
LUTILI
GRID
Ill
(N)200A END FED
MAIN PANEL
I
z D�
LU t\
2:<
N %\]
n
n
n
30A 2P PV
La BREAKER
A
PV BREAKER AT THE
OPPOSITE END OF
EXISTING GROUNDING BUSBAR
ELECTRODE SYSTEM TO
EARTH
REF. NEC 250.52, 250.53(A)
SERVICE INFO
10' MAX -
AC DISCONNECT
SQUARE D SN: D222URB
VISIBLE, LOCKABLE,
LABELED 60A
NON -FUSED, 240V NEMA
3R, UL LISTED
(N)60A AC
r4 DISCONNECT 1-3
UTILITY ONCOR
- -tr—Eo
AH) NAME TX -CITY OF GRAPEVINE
MAIN SERVICE PANEL VOLTAGE 240V
MAIN SERVICE PANEL BRAND UNKNOWN
MAIN SERVICE PANEL
200
MAIN CIRCUIT BREAKER RATING
200
MAIN SERVICE PANEL LOCATION
SOUTH
SERVICE FEED SOURCE
OVERHEAD
MODULE WATTAGE
INVERTER
INVERTER MANUFACTURER
INVERTER QUANTITY
PANEL COUNT
DC SYSTEM SIZE
AC SYSTEM SIZE
400 W 1
SOLAREDGE TECHNOLOGIES SE5000H-US
(240V)
SOLAREDGE
1
SOLAREDGE TECHNOLOGIES SE5000H-US
(240V)
OUTPUT: 240 VAC, 21A
99% CEC WEIGHT EFFICIENCY
NEMA 3R, UL LISTED, INTERNAL GFDI
WITH INTEGRATED DC DISCONNECT
INVERTER-1
17
6.800 KW DC SYSTEM
5.000 kW AC SYSTEM
2
AC
-N
DC
DC DISCO
f I
I I
LOAD RATED DC DISCONNECT
& AFCI
(WITH RAPID SHUTDOWN COMPLIANCE)
OCPD CALCULATIONS
JUNCTION BOX
600V, NEMA 3
UL LISTED
(N)JUNCTION
BOX
PV BREAKER CONNECTION 705.12(B)(2)
INVERTER OVERCURRENT INVERTER O/P I X 1.25
PROTECTION=21xl.25xl=26.25A
=>PV BREAKER = 30A
ALLOWABLE BACKFEED 40A
EE13
(N)QCELLS Q.PEAK DUO ML-G10+ 400W,
40OW MODULES
PV MODULES 9 MODULES WIRED
IN (1) SERIES OF 9 MODULES
MT
__--SOLAREDGE POWER OPTIMIZER P401
DC INPUT POWER - 400 WATTS
I MAXIMUM INPUT VOLTAGE - 60 VDC
MPPT RANGE - 8 TO 60 VDC
MAXIMUM INPUT CURRENT - 11.75 ADC MAXIMUM
OUTPUT CURRENT - 15 ADC STRING LIMITATIONS -
8 TO 25 OPTIMIZERS, 6000 WATTS STC PER
STRING MAXIMUM
(N)QCELLS Q.PEAK DUO ML-G10+ 400W,
40OW MODULES
PV MODULES 8 MODULES WIRED
IN (1) SERIES OF 8 MODULES
T+l �
SOLAREDGE POWER OPTIMIZER P401
DC INPUT POWER - 400 WATTS
MAXIMUM INPUT VOLTAGE - 60 VDC
MPPT RANGE - 8 TO 60 VDC
MAXIMUM INPUT CURRENT - 11.75 ADC MAXIMUM
OUTPUT CURRENT - 15 ADC STRING LIMITATIONS -
8 TO 25 OPTIMIZERS, 6000 WATTS STC PER
STRING MAXIMUM
P a I m 40 41641: 0"
PALMETTO SOLAR t
1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ESID:10443720002209125
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
Cff). nF PAPFIIIAIF
RELEASED AM4MI19TRUCTION
SHEET:
CONDUIT SCHEDULE
RELEASE DOES 4O
TAG ID
CONDUIT SIZE
CONDUCTOR
NEUTRAL
GROUND
CONFLICT WITH THE Bl ILD;ft ��'
1
NONE
(4) 10AWG PV WIRE/USE-2,CU
NONE
(1) 6AWG BARE COPPER, EGC
CITY APPROVE-i FLANS 10 HL KL:Fyt C]N
2
3/4"EMT
(4) 10AWG THHN/THWN-2,CU
NONE
(1) 10AWG THHN/THWN-2, EGC
THE JOE SITffW RFAUU T GMM
3
3/4"EMT
(2) 10AWG THHN/THWN-2,CU
(1) 10AWG THHN/THWN-2,CU
(1) 10AWG THHN/THWN-2, EGC
4
3/4"EMT
(2) 10AWG THHN/THWN-2,CU
(1) 10AWG THHN/THWN-2,CU
(1) 10AWG THHN/THWN-2, EGC
DATE: DRAFFE W:S.RAM
SIZE: 17"Xll"
BUILDING �T p))( ( ,PER
5
NONE
(1) 6AWG BARE COPPER, EGC
RELEASE DOES N IT APPLY TO CON RUCTION IN
EASEMENTS B �iF-WAYREv: A
`�•
ALL CHAI Ai7PRnvitn
DATE:3/4/2022� E-02
SPECIFICATIONS
MODULE SPECIFICATION
MODEL QCELLS Q.PEAK DUO ML-G10+
40OW
MODULE POWER @ STC 40OW
OPEN CIRCUIT VOLTAGE: Voc 45.06V
MAX POWER VOLTAGE: Vmp 37.59V
SHORT CIRCUIT CURRENT: Isc 11.16A
MAX POWER CURRENT: Imp 10.64A
SYSTEM CHARACTERISTICS
DC SYSTEM SIZE 680OW
INVERTER STRING VOLTAGE:Vmp 380V
MAX INVERTER SYSTEM VOLTAGE: Voc 480V
MAX SHORT CIRCUIT CURRENT 30A
OPERATING CURRENT 17.89A
DC WIRE SIZING CALCULATIONS BASED ON THE FOLLOWING EQUATIONS>>
REQUIRED CONDUCTOR AMPACITY: 125% X Isc(A) X #OF PARALLEL STRINGS = MAX CURRENT
PER 690.8(A)(1) X 125% = MAX CURRENT PER 690.8(B)(1)
TAG ID
CORRECTED AMPACITY CALCULATIIONS: AMAPCITY X TEMPERATURE DERATE FACTOR X
1
COUDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER 690.8(B)(2)
DERATE CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(1) < DERATED
2
CONDUCTOR AMPACITY
AC WIRE SIZING CALCULATIONS BASED ON THE FOLLOWING EQUATIONS>>
REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF INVERTERS = MAX
CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER 690.8(B)(1)
TAG ID
CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE FACTOR X
CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER 690.8(B)(2)
3
DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) < DERATED
CONDUCTOR AMPACITY
4
INVERTER-1 SPECIFICATIONS
MODEL SOLAREDGE TECHNOLOGIES
SE5000H-US (240V)
POWER RATING 5000W
MAX OUTPUT CURRENT 21A
I CEC WEIGHTED EFFICIENCY 99%
MAX INPUT CURRENT 13.5A
MAX DC VOLTAGE 480V
OPTIMIZER CHARACTERISTICS
MODEL
P401
MIN INPUT VOLTAGE
8 VDC
MAX INPUT VOLTAGE
60 VDC
MAX INPUT CURRENT
11.75 ADC
MAX OUTPUT CURRENT
15 ADC
Fla I
m ttv
i
PALMETTO SOLAR 6V E
1505 KING ST, d
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
CITY OF dWAOME
RELEASED FQI ��i -rynt;
ELECTRICAL CALCULATIONS SHEET:
RELEASE UUE:ti NL 1 1Uj
DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:900C CONFLICT WITH THE BUILnIP afew
MI 6ecat se qualitymatters
1 X 15 XEQUIRED CONDUCTOR AMPACITY = 18.75A 40 CORRECTED AMPACITY CALCULATION3.20A DERATED
18.75A CONDUCTOR AMPACITY rib Fm-ANO M
��++ �r �- EtDI""T ON
1 X 15 X 1 = 15 X 11.251
1.25=�8.75A 40 I X , 0.71 , X 0.8 f = 22.72A 18.75A < I H 13 i 0E AT TI O N S
nATF- d r :
AC WIRE CALCULATIONS:- MATERIAUCOPPER & TEMPERATURE RATING:90'C BUILDING 1}+I PAPER SIZE: 17"X11"
R5�aACc IZCIf"C Nil i "Jig-aliTION IN
REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AqgW&X49*T8 O � I UHLK-: i IUH I -OF-" AY.
6crN21 X 1 = 21.0 X l 1.25 = 26.25A 40 X 0.87 X 1 , = 34.80A 26.25A < AL C AM-3 �T �'!O�r —REV: A
21 X { 1 + = 21.0 X 1 1.25 = 26.25A 40 X 0.87 X 1 = 34.80A 26.25A 34.80A DATE: 3/4/2022 E-03
I I
EQUIPMENT ELEVATION VIEW
BACKYARD
6' MAX
SINGLE PHASE SERVICE
M
un 10' MAX
GRID
INVERTER-1
MAIN SERVICE PANEL _ -
WINDOW
xm.c mxvEns�on
UTILITY AC
DISCO
INTERIOR
EXTERIOR WALL
INVERTER DIMENSIONS:
HEIGHT: 17.7", WIDTH: 14.6", DEPTH: 6.8"
AC DISCONNECT DIMENSIONS:
HEIGHT: 14.88", WIDTH: 7.45", DEPTH: 4.87"
EQUIPMENT MOUNTING HEIGHTS: APPROX 4 FEET - 6 FEET
PANEL HEIGHT ON ROOF: 4 INCHES MAX
WTEGRATED DC DISCO ---
BACKYARD
Esox
t
8
pa I M e A.A. .0
PALMETTO SOLAR L i
1505 KING ST, d
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: S03 RIDGE ROAD,
GRAPEVINE, TX 760SI
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
Cny r)F CtRAPMllNF
I RE D SED I 'kI STM(NION
SHEET: O
RELEASE DOES F-OT. %Ayr
CONFLICT WITH THE BUI -DI D O
CITY APPROVED N
THE JOB 51� L
DATE: BpAf=.E':s-P�
BUILDING IWeUCBT49LQd�I?ER SIZE: 17' Xll"
RELEASE DOES NCT APPLY TO CONS -RUCTION IN
EASEMENTS v �a -iF-WAY
ALL CHANGE �� A IPRIOA
DATE:3/4/2022 E-04
WARNING PLACARDS
A WARNING
ELECTRIC SHOCK HAZARD
TERMINALS ON BOTH LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR
MODULES ARE EXPOSED TO SUNLIGHT
LABEL LOCATION
AC DISCONNECT,POINT OF INTERCONNECTION
PER CODE: NEC 690.13
LABEL LOCATION
CONDUIT, COMBINER BOX
PER CODE: NEC690.31(D)(2)
PHOTOVOLTAIC
LABEL LOCATION
DISCONNECT, POINT OF INTERCONNECTION
PER CODE: NEC690.13(B)
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
PV PANELS
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
LABEL LOCATION
AC DISCONNECT, DC DISCONNECT,
POINT OF INTERCONNECTION
PER CODE: NEC690.56(C)(1)(A)
INVERTER 1
LABEL LOCATION
DC DISCONNECT
PER CODE: NEC690.53
LABEL LOCATION
AC DISCONNECT, POINT OF INTERCONNECTION
PER CODE: NEC 690.54
WARNING
POURER SOURCE OUTPUT
CONNECTION
DO NOT RELOCATE THIS
OVER -CURRENT DEVICE
LABEL LOCATION
POINT OF INTERCONNECTION
PER CODE: NEC 705.12(B)(3)(2)
A WARNING
DUAL POWER SOURCE SECOND
SOURCE IS PHOTOVOLTAIC
SYSTEM
LABEL LOCATION
POINT OF INTERCONNECTION
PER CODE: NEC705.12(C)
LABEL LOCATION
INVERTER
PER CODE: NEC 690.56(C)(3)
LABEL LOCATION : AC DISCONNECT
LABEL LOCATION : AC DISCONNECT
LABEL LOCATION : AC DISCONNECT
WARNING://.\
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS LOCATED
AS SHOWN
eme
503 RIDGE ROAD, GRAPEVINE, TX 76051
LABEL LOCATION
SOLAR PHOTOVOLTAIC ARRAYS ON
ROOF
(N) JUNCTION BOX
(N) PV INVERTER(EXTERIOR)
(N)60A NON -FUSIBLE VISIBLE LOCKABLE
LABELED DISCONNECT LOCATED
WITH IN LOFT OF ONCOR METER (EXTERIOR)
(N) MAIN SERVICE PANEL(INTERIOR)
(E) ONCOR METER(EXTERIOR)
Palmea®
PALMETTO SOLAR t i
1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
MY f bf� kpgk
RELEASED P STRJ"ION.
SERVICE PANEL
PER CODE: NEC 705.10 SHEET: F:
RELEASE DOES N )T I�E
NOTES: �NBk{RffHTHE BUII 71 J
ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL(;DTS S AALL BE 46ecaIlse AUalft n7atters
RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVIGIT1 1V
APPROVE[ PLANS I0 BE KEPT ON
FASTENERS APPROVED BY THE LOCAL JURISDICTION THE JO�ITE AV CARDS
DATE: _:
BUILDING ' HWPER SIZE: 17"X11"
RELEASE DOES NO - PPLY O ^.ONN RUCTION IN
EASEMENTS CR P,¢U�BUC LiT{01 =WAY.
ALL CHANGE. sc,, NOTED 1PpRO1fbA
DATE:3/4/2022 PL-01
SPEC SHEET
t�tvered try
e - Dq
THE IDEAL SOLUTION FOR:
Rooftop mray6 on
-_,dert al bdd'at95
Engineered in Germany
MECHANICAL SPECIFICATION
Rt1 4Ati%Xst tt,Vt1
�, ;-
Format_ _
Weight
Front Caner
��. ��_-�enS-_retlectro_n
1879mmx1045mmx32mm(tnclucFngframe)-
22.Okg _... __. __.
3.2 mat thermally pre -stressed Bless with - }
technology _- _..___.-�__...__ •�
._.~
.
_
Back Caves
Cornpositefllm
frerrle
Blade enodlsed eluminium
sllirs Qlar heH cells _
-
,!unction box
t
53-101 m 2t60 mmx 15-18 Ma
cl:nraarK lwsr . rw lutaro,pv_'
trowtu essama
ra. a rwrpro„t mzf
v� aecewe6a
.2021
YR
Warranty Q CELLS
woaucr. IN :r: ram.- geld Sacurty
r BREAKING THE 21% EFFICIENCY BARRIER
tfllll�Jl111 Q.ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 21.4%.
,r t THE MOSTTHOROUGH TESTING PROGRAMME IN THE INDUSTRY
Q CELLS is the first solar module marwtacturer to pass the most compre-
hensive quality programme in the Industry: The new 'Quality Controlled
PV' of the independent certification institute TUV Rheinland,
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields, Whatever the weather with excellent
low -light and temperature behaviour.
ENDURING HIGH PERFORMANCE
O Long-term yield security with Anti LID Technology, Art! PID
Technology', Hot -Spat Protect and Traceable Quality Tra.Q14.
EXTREME WEATHER RATING
High-tech aluminium alloy frame, certified for
high snow (5400Pa) and wind loads (4000Pa).
A RELIABLE INVESTMENT
Inclusive 25-year product warranty and 25-year
l� [( linear performance warranty2.
-APT lest cc•4`f-eccxd Qto IEC/TS 62804-1:2015, method A(-1500V, Bat+)
'See data Nest on rear for futher hloa, Minn.
O CELLS
C2
__ Protection class IP67, with bypass diodes _ _-0
Catfla 4mm2 Solar cable;(+) z1250mm,(-) z1250mm --
Connecter Staubil MC4; IP68 + +ta...ncr.tor+..n = I
ELECTRICAL CHARACTERISTICS
POWERCLASS 395 400 405 410 415
'N,iNIi40?P PERr-OPA4R.NCE7tT ST/,rdffARO TEST CONDITIONS. STC`(POWER TOLERANCE +IWi-OW) `.
Powefat MPP^ Prsv ml 395 400 405 410 415
E Short Circuit Caaent' I, [All 11.13 11.16 _11.19 11.22 11.25
E Open Chcua Voltage+yx IV] 45.03 45.06 45.09 45.13 45.16
Current at MPP I„w [Al 10.58 10.64 10.70 10.76 10.82
gyottageatMPP Vrea M 37.32 37.59 37.85 38.11 38.37
EfNctencit II 1%) z20.1 _ _ a20.4 z20.6_ z20.9 z21.1
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT-
Po %r at It, PP P,.r IWI 296.4 300.1 303.9 307.6 3114
E Short Ciauit Currant 1. [A] 8.97 8.99 9.02 9.04 9.07
E Open afcuRVaRa9e Va IV] 42.46 _ 42A9 42.52 42.58 42.59
Ti Curran at MPP I_ (A) 8.33 8.36 8.43 8.48 8.53
voltageat MPP V,,, IV] 35.59 35.82 36.04 36.27 36.49
Weawrement tolererces Pw, t3%; le, Vac t5-%etSTC: 1000 Wlrn2, 25+2°C, AM LS eccadsrg to IEC 61)904-3.2800wfrnr, NMOT, spectrum AM 1.5
0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
�"=b•,�..mw Atleest98%ofna6natpowerdur- Lr, T _r ____.,
o-
S b'9 nr6trear.mn'eaft r-0.5%
I . ....-.._...... ............. degrada ion Pa. year. At loot 93.5% '
Y r
of nommai power up to 10 veers. At
i
w Isss:86%ofnwn�a1pormr upro r '
------------ z5yeers.
Q r All data wiihm �iemant toler, r '
w ancea FMlwa ti. In accordance .n am ..e r rsoo
with uw warranty terms of the e00
Q CELL$ aele6 agaidsaaon of your wa1MJ014
respective country.
Takes Typical rwd0a;, n-Wmsnce under low inadia-e condillortsM
-part- toSTC condifiona (25'C, MO WIW
TEMPERATURE COEFFICIENTS
Temperature Coeff)clent of Ia�
Temperature Coe(ficlent of P_
o
y
(%/Kj +0.04 Tampvmture Coefficient ofV; (! [%/Kj -0.27
1%/K] -0.34 Nominal Module Operating Temperatu* NMOT r•C] 43t3
PROPERTIES FOR SYSTEM DESIGN
Maximum Syaem Voltage
V,,, M
10DO
PymoduladassifkasMn class ll
Maxlmunl Reverse Curt��t
1. [A]
20
Fhe Rating based on ANSI/13761730 C/TYPE2
Max, Design Lasd,Push/Pul1
[Pal
36001 660
Permuted Modulo Temperature-40+C-+85'C
Max. Test toad, Pueh/PUR
[Pal
5400/4000
on Comiwous Duty
QUALIFICATIONS AND CERTIFICATES
cbrxra Pv-nx
iEC 51215,2016: 1EC 61730:20M A Y
Thrrdeu.Metm P6. xrve..r„ Hofzordai
Wei DIN M 50390.
OCWCer0.9wmfcn.Q_* , M9119
PACKAGING INFORMATION
1940ntm 1100mm 1220mm
751kg
28 pellets
24 pallets 32 modules
Note:Insleaelion IrW-1lom nwsl be rdioved. Sae the IWARtIlk end opererrag marvel orenrdactour techrtcal service dapertmant for furtherIMurmation onapp-d Inalallahon and
use of IW. product
Hemrhe O CELLS GmbH
Sonnenellee 17-2% D8766 Bittw6ald-Wolfan, Gerneny I TEL+49(0)34946699-234441 FAX +49IM4946699-230001 EMAILselea®q-oells IWES wnw.q-cda.com
Engineered in Germany
O CELLS
Pa I mettd
PALMETTO SOLAR
1505 KING ST, T� A
CHARLESTON,SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
ILLUMINE i
Recause quality matters
MODULE SPEC SHEET
DRAFTED BY:S.RAM PAPER SIZE: 17"X11"
QC'ED BY:S.SELVAN
SCALE: AS NOTED REV: A
DATE: 3/4/2022 SS-Q 1
SPEC SHEET
Single Phase Inverter
with HD -Wave Technology
for North America
SE3000H-US / SE380OH-Ul / SE5000H-USI/ SE6000H-US /
SE760OH-US / SE10000H- 5 / 5tii4UUN-US
7
0 0 sotnria'Rf ,«NO
p
0 I
a a
r �
12-2s
YEAR 'I
t, WARRANTY
Optimized installation with HD -Wave technology
Specifically designed to work with power optimizers
/ Record -breaking 99%weighted efficiency
/ Quick and easy inverter commissioning directly from
a smartphone using the SolarEdge SetApp
/ Fixed voltage inverter for longer strings
f Integrated arc fault protection and rapid shutdown
for NEC 2014, NEC 2017 and NEC 2020 per article
690.11 and 690.12
solaredge.com
0
0
/ UL1741 SA certified, for CPUC Rule 21 grid compliance
/ Small, lightweight, and easy to install both
outdoors or indoors
/ Built-in module -level monitoring
/ Optional: Faster installations with built-in
consumption metering (1%accuracy) and
production revenue grade metering (0.5% accuracy,
ANSI C12.20)
solar-=vz-
Single Phase Inverter with HD -Wave Technology
for North America
SE300OH-US / SE380OH-US � SE5000H-US / SE6000H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
OUTPUT
3800 @ 240V 6" @ 240V 1 11400 @ 240V
Rated AC Power Out ut 3000 5000 7600 1D000 VA
P � 3300 @ 208V 5000 @ 20BV ? 10000 @ 208V
t
Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 f ' 10W0 11400 @ 240V
3306 @ 208V 5000 @ 208V _ _ 10000 @ 208V VA
AC Output Voltage Min.-Nom: Max. ✓ i ✓ ✓ ✓ ✓ ✓ it ✓ I Vac
(211 - 240 - 264) _
AC Output Voltage Min,-Nom,-Max. _ ✓ _ _ j _ i ✓ Vat
(183 - 208 - 229)
AC Frequency (Nominal) 59.3 - 60 - 605"' ! Hz
Maximum Continuous Output 125 16 21 25 — 32 I 42 I�47,5 A
Current @240V t t
Maximum Continuous Output 16 - 24 - - I 48.5 A
Current Factor
Pallmettd
Power Factor 1 Adjustable - 0.85 to 0.85
GFDI Threshold 1 A
Utility Monitorirg, Islanding Protection, Yes -
_CountryCo_nfigurableThresholds `_�___-__ __--__•,—__._—__.—,__�-__ _._----._—__,.�_—. %,r
INPUT PALMETTO SOLAR
Maximum DC Power @240V 4650 1 5900 7750 9300 1 Iwo t55D0 17650 W
1505 KING ST,
Max mum DC Power @208V I 5100 7750 15500 w CHARLESTON, SC 29405 3/4/2022
= - - (855)339-1831
Trforess, Ungrounded Yes
—ansmer-1
---•--------------------------•--•----------------------------•— NABCEP#: PV-080720-027672
MaalmumInput vbbge _ _ 480 Vdc ELECTRICAL LIC#:477031
Nominal DC Input Voltage = 60 i 400 Vct
Maximum Input MaximuminpuiCurrent@2 85 3 195 13.5 13.5 - 27 05 Adc CUSTOMER INFORMATION
Max. Input Short Circuit Current 45 1 Adc
Reverse-PolarityProtection Yes NAME: CHRISTIAN BRIENZA
Ground -Fault Isolation Detection 60010 Sensitivity _ I
Maximum Inverter Efficiency 99 99.2 %
Weighted 59 @ `4nV
CEC Wei Efficie 99 %
9 r'4' 98.5 @ 208V
Nighttime Power Consumption <2.5 I W ADDRESS: 503 RIDGE ROAD,
0)For onh regioralWningspL-asecon:art5olarEdgearpport GRAPEVINE, TX 76051
(2) A higher cuTTM soure may be used; the inverter vrdl limit its mpvt wane t to the values stated
32.936385,-97.090502
APN: 007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
i ILLUMINE
Because r; uality rrratters
INVERTER SPEC SHEET
DRAFTED BY:S.RAM PAPER SIZE: 17"X11"
QC'ED BY:S.SELVAN
SCALE: AS NOTED REV: A
DATE: 3/4/2022 SS-02
SPEC SHEET
I Single Phase Inverter with HD -Wave Technology
for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6O00H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
ADDITIONAL FEATURES
Supported Communication Interfaces
RS485, Ethernet ZigBee (optionap, Cellular (optionap
Revenue Grade Metering, ANSI C12.20
OptionaF
Consumption metering
_
I
Inverter Commissioning
With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection
I
Rapid Shutdown - NEC 2014, NEC
Automatic Rapid Shutdown upon AC Grid Disconnect
i
2017 and NEC 2020, 690.12
STANDARD COMPLIANCE
_
Safety
UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
i
Grid Connection Standards
IEEE1547, Rule 21, Rule 14 (HI)
Emissions
FCC Part 15 Class B
!
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG Range
1" Maximum / 14-6 AWG
I 1" Maximum A4-4 AWG
DC Input Conduit Size / e of Strings /
1` Maximum / 1-2 strings / 14-6 AWG
1" Maximum / 1-3 strings / 14-6 AWG
AWG Range
Dimensions with Safety Switch (HxWxD)
17.7 x 14.6 x 6.8 1450 x 370 x 174
21.3 x 14.6 x 7.3 / 540 x 370 x 185
! in / mm
Weight with Safety Swmtch
22 / 10 25.1 / 11.4 1 26.2 / 11.9
38.8 / 17.6
j lb / kg
Noise
< 25 1
<50
dBA
Cooling
Natural Convection
_
I
_
Temperature Range
-40 to +140 / -40 to +600
_
I 'F /'C
_Operating
Protection Rating
NEMA 4X (Inverter with Safety Switch)
!
(3) Inverter wdh Revenue Grade Meter P/N: SE o H-USOOOBNC4: Inverter vrth Revenue Grade Production and Consumption MeterP/N: SEx H-USOOOBNI4. For consumption metering, current trarnfonnm
should be ordered s tately: SEACT0750--aWNA-20 or SEACT0750.400NA-20. 20 units per box
(4) Full pcAvK up to a least �O C i 122'F; for power de -rating Wurriation refer to: httpsJ/w".solaredee.com/�,;iteVdef�il,!bLs! temperahne-derating-note-mi.pdf
How to Enable Consumption Monitoring
By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service
panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills
Single phase inverter with
Hb-wave technology and
built-in RGM and
Service Panel consumption monitoring
Grid
ITT
LT L1 N L?
Shielded CATSe cable
e
►� L1
s
- AC Conduit
O solar&tgeTechnobgi z me All dghu reserved. SOIAREDGE, the S.ImEdge bgo, OFrOMED BY SOLAREDGf am vadcmmks m registered trademarks of SolerEdge Teduobgies, Im, All ROtIl1
etheriademada rt ioned heroin am vademarl3 of their respective owners. Date 12M20 W1/ENG NAM Subject to chane without notae. ■
Palmetto
PALMETTO SOLAR
1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
'rY
Recause quality platters
INVERTER SPEC SHEET
DRAFTED BY:S.RAM
QC'ED BY:S.SELVAN PAPER SIZE: 17"Xll"
SCALE: AS NOTED REV: A
DATE: 3/4/2022 SS-03
I
SPEC SHEET
Power Optimizer
Frame -Mounted
P370 IP4Kk P404 / P500
0 17' "2]5
'WA=TY
Fast mount power optimizers with module -level optimization
Specifcally designed to work with SolarEdge
inverters
Quicker installation - Power optimizers can be
mounted in advance saving installation time
I Up to 25% more energy
I Superior efficiency (99.5%)
solaredge.com
MV
0
m
O
-o
N
m
I Mitigates all types of modules mismatch -loss,
from manufacturing tolerance to partial shading
Flexible system design for maximum space
utilization
I Next generation maintenance with module level
monitoring
I Module -level voltage shutdown for installer and
firefighter safety
s I - vji-L�,-4
o cin:a
am&
Power Optimizer
Frame -Mounted
P370 / P40 / P404 / P500
INPUT _
Rated Input DC Powerm 370 4DO 405 _ 1 SOD W
Absolute Maximum Input Voltage 60 80 Vdc
(Voc at lowest temperature)
MPPT Operating Range 8-60 12.S - 80 8 - 80 Vdc
Maximum Short Circuit Current aW 11 11,75 11 1 10.1 Adc
Maximum Efficiency _ 99.5 %
Weighted Efficiency 98.8 _ %
Overvoltage Category _ 11 .
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED')O OPERATING SOLAREDGE INVERTER)
Maximum Output Current — 15 Adc_
Maximum Output Voltage 4 60 85 —� 60 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FFE_IM SOLAREDGE INV: ATER OR SOLAREDGE INVERTER OFF) _
Safety Output Voltage per Power Optimizer �— 1 t 0.1 - T Vdc
STANDARD COMPLIANCE _
EMC FCC 3art15 Class 8, IEC610OD-6-; IEC61OW-6-3
Safety v� JEC62109-1(class D safety,' UL1741
RoHS Yee
Fire Safety VDE-AR-E 2100-712:20 13-05
INSTALLATION SPECIFICATIONS _
Maximum Allowed System Voltage 1000 _ Vdc
08x 5/5.
Dimensions (W x L x H) 139x165x40/5.5x6.5x1.6 129x153x29.139x165x48/S.Sx6Sx1.9 mm/in
6.02 x 1.16
Weight (including cables) 775 / L7 65511.5 895 / 2.0 ! 870/ 1.9 gr/ Ib
Input Connector MC4M
Input Wire Length 0.16 / 0.52 m / ft
Output Connector MC4 -- .-- — .....
Output Wire Length 12 / 3.9 m / ft
Operating Temperature Ranger -40 to +85 / -40 to +185 'C / `F —
Protection Rating fP68 / NEMA6P
Relative Humidity 0 -100-
(1) Rated power of the module at STC will not exceed the optim¢er'Rated Input DC Power'. Modules with up to +5% Parer tolerance are alloyed
(2) For other connector types please contact SolarEdge
(3) For ambient temperature above +85'C / +185'F power de -rating is applied Refer to Power Opt(mizers Temperature De -Rating Technical Note for more details
THREE PHASE
PV SYSTEM DESIGN USING SINGLE PHASE SINGLE THREE �.
SOLAREDGE HD-WAVEGRID 511Aported
P3701 frame
Minimum String Length P58 16 18 cro55 section
(Power Optimizers) - -
P4fY) 1 6 14 (13 with SE3IQ" 14 `
Maximum String Length (Power Optimizers) 25 50 50
Maximum Nominal Power per string 57M5250M 11250- 1275D W
n
_ _ �.—_. 1.1-2.2mm /
Parallel Strings of Different Lengths Yes _J0.04-0.09in
or Orientations ��
(4) Itis not allowed to mix P404 with P370/P401/P5W in one suing L�
(5) The P37otmovP500 cannot be used with the SE3K three phase inverter (available In some omuntries refer to Three Phase )reverter SBK-SE1DK datasheet) > 12mm / OA8in
(6) Exacdy 10 when using SE3K-RW0108NN4
(7) If the inverters rated Ae power s maximum nominal power per string, then the maximum power per string will be able to reach up to the irgerter5 maiumum
input DC power Refer to: htq)W/-sdamdge.com/sites/defau"es/se-power-optimizer-singfe-string-desgn-apprication-mte.pM
(9) For SE27.6K SE55K SE82.8K: R is allowed to install up to 13,SD0W per string when 3 strings are connected to the inverter and when the maximum pourer
difference between the strings is up to 2,000W: inverter max DC pawer:37,25OW
O SoarEdge Ted wlo9iet. hoc AD right re—ved. SOLAREDGE the SolarEdgeb9q MWIRED BYSOtAREM.E art tradam9ft5 -get W tradern"la of SoWfdge TechwbGiK hx CE
AN adwvadmM3 mall dhereina mdwrwla o1 tt respmt1% nvners Date 0WMI M-OO 12-MSu�mchange widan nobi
(PD Palm,,,'Ltd
PALMETTO SOLARu `
1505 KING ST, r
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
4 a
ILLUMINE *I
A
• Reeausertualftymatters
OPTIMIZER SPEC SHEET
DRAFTED BY:S.RAM PAPER SIZE: 17"X11"
QC'ED BY:S.SELVAN
SCALE: AS NOTED REV: A
DATE:3/4/2022 SS-04
SPEC SHEET
L-Mount I QMLM / OMLM-ST
Elevated Water Seal Technologyo
REM
THIS EDGE TOWARDS ROOF RIDGE _ NO.
1
2
3
4
-5
DESCRIPTION CITY.
FLASHING, ROUNDED CORNERS. 7' X 12' X .040", .438" HOLE, 5052, 1
MILL
L-FOOT, 2' X 3.3W FOR .438" O.D. FASTENER, 2-1 /16" SLOT, 6061- 1
T6/600.5A-T61. MILL
WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1
LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1
STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2'. 1
18-ass
12.00 •5 �' 1
'1
04
(4,20)YAND
URAL
3.00
t J ��—E ON
fi-ST
4.50 — ONLY
9,00 i
2.00
0.408 � � �l .00 99
-f-L-- N MILL,
3 + 1_ �0) 0 _FINISHES i
f -- TITLE: i—
C�iickMomitPV-
.040
(2.50) (3,54) 275 4.foa QMLM & QML S : L MOUNT, 2-
QMLM QMLM-ST uN1650TMERwtSESPEQ ER— SIZE I DRAWN BY: AAP REV
ouacwsioru neE P+P'ic Es I . _
ra C6' A I DATE 4/4/2019
RL' �W "4ORAYING6"E C1ErtO,EfiYaFO.i!y(NO,Y.'1w./MeStODJCPONM�AR04 AtAWHDIFv41HdCME DO h*1 SCALE DRAWRK TWO P(hCE OEGiMA1. 3.79
'r,Mm, KRxR�IXiw0Uc5 r0u.Trv6fllaF1[a COF1'ItIC.M02011 QI.00MOWIfN THREEPLACEDEC•ML r.MA $CALF:7:4 �WFGM:0.7565 SfI�EIOrI
5 4 3 2 1
B17.2.3-44
Qu i c k Mount
RESPECT THE ROOF
Apr-2019 Rev 6
L-Mount Installation Instructions
Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing
materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket.
WARNING: Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment.
Locate, choose, and mark centers of rafters to be Carefully lift composition roofshingle with roofing Insert flashing between 1st and 2nd course. Slide
mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least 1'4" higher
mounts will be placed. nails as required and backfill holes with aproved than the butt -edge of the 3rd course and lower
sealant. See "Proper Flashing Placement" on next flashing edge is above the butt -edge of 1st course.
page. Mark center for drilling.
f attachingwith lag bolt use a M2" bit (Lag). Use a
Ys" bit (ST) for attaching with the structural screw.
Drill pilot hole into roof and rafter, taking care to
drill square tothe roof. Do not use mount as a drill
guide. Drill a 2" deep hole into rafter.
Clean off any sawdust, and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to
compatible with roofing materials. desired orientation.
Prepare lag bolt or structural screw with sealing
You are now ready for the rack of your choice.
washer. Using a th-inch socket on an impact gun,
Follow all the directions of the rack manufacturer
drive prepared lag bolt through L-foot until L-foot
as well as the module manufacturer. NOTE: Make
can no longer easily rotate. DO NOT over -torque.
sure top of L-Foot makes solid contactwith racking.
NOTE: Structural screw can be driven with T-30 hex
head bit.
BI 7.2.3-44
Apr-2019 Rev 6
Paim 1""0
PALMETTO SOLAR
1505 KING ST,
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
I ILLU INEI
' Beaausequality inatter
MOUNT SPEC SHEET
DRAFTED BY:S.RAM PAPER SIZE: 17"X11"
QC'ED BY:S.SELVAN
SCALE: AS NOTED REV: A
DATE:3/4/2022 SS-05
SPEC SHEET
IRONRIDGE
.62
XR10 Rail
.46
} 3 Rai Section Proper ies
I Property V ahie
1.37
ITotalCross-SectionalArea 0.363 in2.
1.'5 1 33 ISection Modulus IX-axisl 0.136 in
IMoment of Inertia (X-axis) 0.124 in"
IMoment of Inertia (Y-axis) 0.032 in
58 Torsional Constant 0.076 in3
j Polar Moment of Inertia 0.033 in
1.00 —
Clear Part
Black Part
Description / Length Material
Weight
Number
Number
XR-10-132A
XR-10-132B
XR10, Rail 132" (11 Feet) 6000-Series
4.67lbs.
XR-10-168A
XR-10-168B
XR10, Rail 168" (14 feet) Aluminum
5.95 tbs.
XR-10-204A
XR-10-204B
XR10, Rail204" (17 Feet)
7.22lbs.
qP Palmettd
PALMETTO SOLAR�q t
1505 KING ST, w'
CHARLESTON, SC 29405 3/4/2022
(855)339-1831
NABCEP#:PV-080720-027672
ELECTRICAL LIC#:477031
CUSTOMER INFORMATION
NAME: CHRISTIAN BRIENZA
ADDRESS: 503 RIDGE ROAD,
GRAPEVINE, TX 76051
32.936385,-97.090502
APN:007-02-234
AHJ: TX -CITY OF GRAPEVINE
UTILITY: ONCOR
PRN NUMBER: PLO-46199
ILLUMINE i
' l3ecause quality matters
RAIL SPEC SHEET
v1.0 DRAFTED BY: S. RAM
QC'ED BY:S.SELVAN PAPER SIZE: 17"Xll"
SCALE: AS NOTED REV: A
DATE:3/4/2022 SS-06
March 4, 2022
Palmetto Clean Technology
1505 King Street Ext.
North Charleston, SC, 29405
structural
ENGINEERS
Subject: Structural Certification for Installation of Solar Panels
Job Number: 22-02489
Client: Christian Brienza - PLO-46199
Address: 503 RIDGE ROAD, GRAPEVINE, TX 76051
Attn.: To Whom It May Concern
PZSE's scope of work is limited to performing a structural evaluation of loading at the address above. After review, PZSE certifies
that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and
criteria shown below:
Design Criteria:
• Applicable Codes = 2018 IBC, ASCE 7-16, and NDS-18 �
• Ground Snow Load = 5 psf; Roof Snow Load = 3.5 psf ARRAY 1, 3, 4, R..51psf ARRAY 2
• Basic Wind Speed =105 mph Exposure Category B 0
• Existing Roof Dead Load: ARRAY 1, 3, 4, & 5 = 10 psf; AR'201'8
�4�psf
• Existing Roof Live Load: 20 psf; Existing Roof®rtion
The existing structure is adequate to support the PVer IEBC §402.3 & 402.4.
PV System Assembly
The PV module assembly including all structural supporting components have been reviewed to be in accordance with the
manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above.
Installation Requirements
The PV system shall be mounted flush to the existing roof surface. The contractor shall notify PZSE of any signs of damage to the
roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is adequate to support the
applied loads. The electrical engineering and system waterproofing shall be addressed by others.
If you have any questions on the above, do not hesitate to call.
Prepared By:
PZSE, Inc. - Structural Engineers
Roseville, CA
1478 Stone Point Drive, Suite 190, Roseville, CA 95661
916.961.3960 = 916.961.3965 www.pzse.com
SERVICES
Attn: Bu i Id i ng/I nspections Dept.
Grapevine
200 S. Main St Grapevine, TX 76051
Please find enclosed a Permit Application and Documents for a solar panel Installation
for the Address: 503 Ridge Rd Grapevine, TX 76051
Please let me know if you have any questions and/or if there is anything else you need.
Thank you in advance for your help!
Best,
Victoria Anderson
Permit Expeditor
TITAN Services, LLC
M: 817-752-9653 EXT: 103
Refs: Christian Brienza
ENCLOSURES
G®
E: victoriasC@a. �m
• 1 Electrical permit application
• 1 Building permit application
• 2 Plan -sets
• 2 Engineer Letters
• 1 Prepaid Envelope
TITAN Services 17201-C Baker Blvd. Suite C1-3, Richland Hills, Tx. 76118
Office:901-248-01991
SERUIEES
Attn: Building/Inspections Dept.
Grapevine
200 S Main St Grapevine, TX 76051
Please find enclosed a Check for the permit fee for a solar panel Installation
for the Address: 503 Ridge Rd Grapevine, TX 76051
Please let me know if you have any questions and/or if there is anything else you need.
Thank you in advance for your help!
Best,
Victoria Anderson
Permit Expeditor
TITAN Services, LLC
M: 817-752-9653 EXT: 103 E:
Refs: Christian Brienza
ENCLOSURES
• 1Check $187.00
TITAN Services 17201-C Baker Blvd. Suite C1-3, Richland Hills, Tx. 76118
Office:901-248-01991