HomeMy WebLinkAboutORD 2022-024ORDINANCE NO. 2022-024
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS, ISSUING SPECIAL USE PERMIT
SU22-02 TO AMEND THE SITE PLAN SU2016-03 TO
EXPAND THE GROUND LEASE AREA ASSOCIATED WITH
AN EXISITNG 75-FOOT HIGH MONOPOLE ON LOT 3,
GRAPEVINE INDUSTRIAL PARK (525 INDUSTRIAL
BOULEVARD) IN A DISTRICT ZONED "LI" LIGHT
INDUSTRIAL DISTRICTALL IN ACCORDANCE WITH A SITE
PLAN APPROVED PURSUANT TO SECTION 47 OF
ORDINANCE NO. 82-73 AND ALL OTHER CONDITIONS,
RESTRICTIONS AND SAFEGUARDS IMPOSED HEREIN;
CORRECTING THE OFFICIAL ZONING MAP; PRESERVING
ALL OTHER PORTIONS OF THE ZONING ORDINANCE;
PROVIDING A CLAUSE RELATING TO SEVERABILITY;
DETERMINING THAT THE PUBLIC INTERESTS, MORALS
AND GENERAL WELFARE DEMAND THE ISSUANCE OF
THIS SPECIAL USE PERMIT; PROVIDING A PENALTY NOT
TO EXCEED THE SUM OF TWO THOUSAND DOLLARS
($2,000.00); DECLARING AN EMERGENCY AND
PROVIDING AN EFFECTIVE DATE
WHEREAS, an application was made requesting issuance of a special use permit
by making applications for same with the Planning and Zoning Commission of the City of
Grapevine, Texas, as required by State statutes and the zoning ordinance of the City of
Grapevine, Texas, and all the legal requirements, conditions and prerequisites having been
complied with, the case having come before the City Council of the City of Grapevine,
Texas, after all legal notices requirements, conditions and prerequisites having been
complied with; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council did consider the following factors in making a determination as to
whether this requested special use permit should be granted or denied: safety of the
motoring public and the pedestrians using the facilities in the area immediately surrounding
the site; safety from fire hazards and measures for fire control; protection of adjacent
property from flood or water damages, noise producing elements, and glare of the
vehicular and stationary lights and effect of such lights on established character of the
neighborhood; location, lighting, and types of signs and relation of signs to traffic control
and adjacent property; street size and adequacy of width for traffic reasonably expected to
be generated by the proposed use around the site and in the immediate neighborhood;
adequacy of parking as determined by requirements of this ordinance for off-street parking
facilities; location of ingress and egress points for parking and off-street locating spaces,
and protection of public health by surfacing on all parking areas to control dust; effect on
the promotion of health and the general welfare; effect on light and air; the effect on the
overcrowding of the land; the effect on the concentration of population; the effect on the
transportation, water, sewerage, schools, parks and other facilities; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council of the City of Grapevine, Texas, did consider the following factors
in making a determination as to whether this requested special use permit should be
granted or denied; effect on the congestion of the streets, the fire hazards, panics and
other dangers possibly present in the securing of safety from same, the effect on the
promotion of health and the general welfare, effect on adequate light and air, the effect on
the overcrowding of the land, the effect on the concentration of population, the effect on
the transportation, water, sewerage, schools, parks and other public facilities; and
WHEREAS, all of the requirements of Section 49 of Ordinance No. 82-73 have been
satisfied by the submission of evidence at a public hearing; and
WHEREAS, the City Council further considered among otherthings the character of
the existing zoning district and its peculiar suitability for particular uses and with the view to
conserve the value of buildings and encourage the most appropriate use of land
throughout this City; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is
a public necessity for the granting of this special use permit, that the public demands it,
that the public interest clearly requires the amendment, that the zoning changes do not
unreasonably invade the rights of those who bought or improved property with reference to
the classification which existed at the time their original investment was made; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that the
special use permit lessens the congestion in the streets, helps secure safety from fire,
panic and other dangers, prevents the overcrowding of land, avoids undue concentration of
population, facilitates the adequate provisions of transportation, water, sewerage, schools,
parks and other public requirements; and
WHEREAS, the City Council of the City of Grapevine, Texas, has determined that
there is a necessity and need for this special use permit and has also found and
determined that there has been a change in the conditions of the property surrounding and
in close proximity to the property requested for a change since this property was originally
classified and, therefore, feels that the issuance of this special use permit for the particular
piece of property is needed, is called for, an is in the best interest of the public at large, the
citizens of the City of Grapevine, Texas, and helps promote the general health, safety and
welfare of this community.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS:
Section 1. That the City does hereby issue a special use permit in accordance
with Section 49 of Ordinance No. 82-73, the Comprehensive Zoning Ordinance of the City
Ordinance No. 2022-024 2
of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by
granting Special Use Permit No. SU22-02 to amend the site plan SU2016-03 to expand the
ground lease area associated with an existing 75-foot high monopole (AT&T Cell Tower) in
a district zoned "LI" Light Industrial District within the following described property: Lot 3,
Grapevine Industrial Park (525 Industrial Boulevard) all in accordance with a site plan
approved pursuant to Section 47 of Ordinance No. 82-73, attached hereto and made a part
hereof as Exhibit "A", and all other conditions, restrictions, and safeguards imposed herein,
including but not limited to the following: None.
Section 2. The City Manager is hereby directed to amend the official zoning map
of the City of Grapevine, Texas, to reflect the herein special use permit.
Section 3. That in all other respects the use of the tract or tracts of land herein
above described shall be subject to all the applicable regulations contained in said City of
Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of
Grapevine, Texas.
Section 4. That the zoning regulations and districts as herein established have
been made in accordance with the comprehensive plan for the purpose of promoting
health, safety, morals and the general welfare of the community. They have been
designed with respect to both present conditions and the conditions reasonably anticipated
to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from
fire, panic, flood and other dangers; provide adequate light and air; to prevent
overcrowding of land, to avoid undue concentration of population; facilitate the adequate
provisions of transportation, water, sewerage, drainage and surface water, parks and other
public requirements, and to make adequate provisions for the normal business, commercial
needs and development of the community. They have been made with reasonable
consideration, among other things, of the character of the district, and its peculiar suitability
for the particular uses and with a view of conserving the value of buildings and encouraging
the most appropriate use of land throughout the community.
Section 5. This ordinance shall be cumulative of all other ordinances of the City of
Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said
ordinances except in those instances where provisions of those ordinances which are in
direct conflict with the provisions of this ordinance.
Section 6. That the terms and provisions of this ordinance shall be deemed to be
severable and that if the validity of the zoning affecting any portion of the tract or tracts of
land described herein shall be declared to be invalid, the same shall not affect the validity
of the zoning of the balance of the tract or tracts of land described herein.
Section 7. Any person violating any of the provisions of this ordinance shall be
deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to
exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed
committed upon each day during or on which a violation occurs or continues.
Ordinance No. 2022-024 3
Section 8. The fact that the present ordinances and regulations of the City of
Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace
and general welfare of the inhabitants of the City of Grapevine, Texas, creates an
emergency for the immediate preservation of the public business, property, health, safety
and general welfare of the public which requires that this ordinance shall become effective
from and after the date of its final passage, and it is accordingly so ordained.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS on this the 19th day of April, 2022.
/.\Ja 10171:4
William b. Tate
Mayor
ATTEST:
ZN
Tara Brooks
City Secretary rCo
APPROVED AS TO FORM:
Matthew C.G. Boyle
City Attorney
Ordinance No. 2022-024 4
M
--j
LINE TABLE
LINE # BEARING, DISTANCE
L1
N 00'4445' E, 18.43'
L2
N 89'1515' E, 20.00'
L3
S 00'445' E, 6.00'
L4
N 8T15'15* E, 25.82'
L5
S 00'11'00' E, 5.11'
L6
S 89'15'15' W, 5.77'
L7
S 89'15'15' W. 16.00'
L8
S 00'44'45' E, 10.00'
L9
S 89'15'15' W, 35.00'
L10
N 00'44'45' W, 16.00'
U1
N 89'15'15' E, 55.00'
L12
N 00'44'45' W, 10.00'
L13
S 00'44'12' E, 5.00'
L14
N 00-11'00' W, 5,00'
« EX. FIRE HYD.
-Fi
3
ZONING: LI (LIGHT INDUSTRIAL)
LOTS 1 & 2 FIRST SECTION OF
GRAPEVINE INDUSTRIAL PARK
N 8949' E 260.00'
I I _
5 � -
w�
i
CD
EXISTING SINGLE EXISTING SINGLE
STY METAL BLDG. STY METAL BLDG.
5,034 SFT. 3,794 SFT.
� I
1+
228.6't .—
= Z LOT 3 FIRST SECTION OF FIRE LANES
GRAPEVINE INDUSTRIAL PARK
3 5 PARKING SPACES _ I 8 PARYNG SPATES
I EASE ALIEA 8
N
� � � � �—�-8.8' (1'P•) � N 8�'15'15 E I1.10' H-
- — — — u — wa1F'an c nbin' — - -
_------------- M L11 p1p7.9�t
- J
3
26.8't
S 89'15'48 W I' 41F+ I to � .4 �� $
UTllf�lf ESMT _ 8 PARt1N SP%ES _ Lg I L6
7 P NG S►4CES i I — �[� /I I_ 2 PARKING SPACES
In N
— —' j�' — — — — — — — N89'10'57E 2D9_43'— — — —
FIRE LANES PROPOSED GENERATOR
II ZONING: LI (LIGHT INDUSTRIAL) �ACCESS ESMT• (SEE SITE PLAN)
- - - - - - - -
— — — — — — — — S89'10'57W 249.63'
EXISTING SINGLE
STY METAL BLDG.
11,843 SFT.
' I S 89'49' W 260.00'
V
LOT 4RI FIRST SECTION OF
GRAPEVINE INDUSTRIAL PARK
GRAPHIC SCALE
I inch= 30 feet (I I"xl7")
0 is 30 I ZONING: LI (LIGHT INDUSTRIAL) I
LOT 4 FIRST SECTION OF
GRAPEVINE INDUSTRIAL PARK
PARKIN ANALYSIS
Total Building Area: 20,671 sft.
Zoning: Light Industrial
Total Number of Parking Spaces Required: 21
(1 spa / 1000 sft. GFA)
Total Number of Parking Spaces Provided: 40
(includes 1 ADA space; 1 ADA space per
25 required spaces)
N
v
am
FF
SITE CALCULATIONS CHART
6
!j2 =
EXISTING
PROPOSED
TOTAL BUILDING AREA: 20,671 SFT.
TOTAL BUILDING ARE& 20,671 SFT.
GROUND LEASE AREA: 825 SFT
GROUND LEASE ARE& 985 SFT
TOTAL LOT AREA 63,180 SFT.
TOTAL LOT AREA: 63,180 SFT.
TOTAL OPEN SPACE 42,509 SFT.
TOTAL OPEN SPACE 42,469 SFT.
#411�
a=
4a6NERAL GKNAMNCS
Wireless Services
12906 SHELBYVILLE ROAD, STE. 230
LOUSIVILLE, KY 40243
502-653-6963
DRAWING REVISIONS
REV. DESCRIPTION DATE
BY
1 GEN. RELOCATION 11/10/21
MCB
2 AM SIG BLOCK 1/20/22
OSB
3 ADD OVERALL SiE PLAN 2/17/22
OSB
4 REV. PER SU 22d2 3/ 18/22 REV. LETTER 3/28/22
DSS
5 REV. REAR 15' ESMT. 3/31/22
OSB
6 REV. PER E MAROHNIC 33622 4/6/22
DS8
7 REV. LEASE AREA 4/7/22
OSB
#
DANIEL SCOTT BORDENET
...............................
:9. 126055 .4�
CERIIFUTE OF REGISTRATION UNOER BORDENET
COW LTNG, LM REGISTRATION K%IW F-18788.
O02 A NCK CL, IMPLS., N 482%. 317-BI &U2.
SHEET NAME:
OVERALL SITE PLAN
PROJECT DESCRIPTION
This project proposes to extend the ground lease
area of an existing monopole tower and ground
equipment for the purposes of adding a backup
generator.
APR 12 2022
CASE NAME: AT&T CELL TOWER
CASE NUMBER: SU22-02
LOCATION: 525 INDUSTRIAL BOULEVARD.
MAYOR
SECRETAERY
DATE
PLANNING & ZONING COMMISSION
CFWIRMAN
DATE
APPROVAL DOES NOT AU►M71NZ£ ANY MOW 6Y
CWIICT 10 COST OR ORDIN4M
DTL OF PLANNING SERVICES
HWY 114/RVDUSTRIAL GENERATOR UPGRADE SITE PLAN
FA#:10011197
525 INDUSTRIAL BLVD.
GRAPEVINE, TX 76051
Lot 3 of First Section of Grapevine Industrial Park
Vol. 388-140, Pg. 84 Deed Records of Tarrant County Texas
Ambrose Foster Survey, Abstract No. 5188
Site No. 80486061, Instr. No. D210182070
Date of Preparation: March 28th, 2022
SHEET NO.: REVISION
NUMBER
1 OF 6 4
B
SCOPE OF WORK NOTES
GENERAL:
• VERIFY LOCATION OF ALL EQUIPMENT ON SITE.
• NEW GENERATOR PROVIDED BY GENERAL DYNAMICS AND INSTALLED BY GENERAL
CONTRACTOR.
• NEW CONCRETE PAD PROVIDED AND INSTALLED BY GENERAL CONTRACTOR (AS
REQUIRED). SEE S-1.
• NEW AUTOMATIC TRANSFER SNATCH PROVIDED BY GENERAL DYNAMICS AND INSTALLED
BY CONTRACTOR (AS REQUIRED)
• CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION.
• CONTRACTOR SHALL RESTORE AND REPAIR ANY DAMAGED AREAS CAUSED BY
CONSTRUCTION TO ORIGINAL OR BETTER CONDITION.
CONDUITS:
• INSTALL PULL STRING IN EACH CONDUIT.
• (1) NEW 2" CONDUIT WITH CONDUCTORS TO RUN FROM NEW GENERATOR TO NEW ATS.
CONDUIT PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. SEE E-1
• (1) NEW 1" CONDUIT WITH CONDUCTORS TO RUN FROM NEW GENERATOR TO AC PANEL
FOR GENERATOR BLOCK HEATER AND BATTERY HEATER/CHARGER. CONDUIT PROVIDED
AND INSTALLED BY GENERAL CONTRACTOR. SEE E-1
• (2) NEW 1" CONDUITS FOR START CIRCUIT AND ALARM CABLING. CONDUIT PROVIDED
AND INSTALLED BY GENERAL CONTRACTOR. SEE E-1
• AFTER INTERCEPTING MAIN POWER FEED BEHIND PRIMARY DISCONNECT, ROUTE MAIN
POWER FEED TO NEW ATS, THEN RECONNECT NEW ATS TO AC PANEL. SEE SHEET E-1.
• CONNECT NEW ATS TO TELCO BOARD/ALARM. SEE SHEET E-1,
71.00'
GROUNDING:
• NEW EXOTHERMIC CONNECTION FROM EXISTING GROUND RING TO NEW MECHANICAL
CONNECTION AT GENERATOR CHASSIS. GENERAL CONTRACTOR TO VERIFY LOCATION IN
FIELD. LOCATE GROUND RODS NO MORE THAN 16'-0" APART.
H—FRAME:
• PROVIDE NEW H—FRAME IF REQUIRED, MATCH EXISTING H—FRAME MATERIAL FOR
CONSTRUCTION OF NEW H—FRAME.
• USE ALL GALVANIZED COMPONENTS, WHITE PLASTIC CAPS ON UNI—STRUTS, WEATHER
CAPS ON TOPS OF PIPE AND CONCRETE.
• SUPPORTS BELOW FROST LINE.
• TOP OF FOOTING SHOULD BE AT LEAST 2" ABOVE EXISTING GROUND LEVEL.
• SLOPE THE GROUND AWAY FROM THE H—FRAME FOR POSITIVE WATER DRAINAGE OFF OF
THE FORM.
SITE REQUIREMENTS PER SU22-02:
• REFUSE DISPOSAL AREAS SWILL BE LANDSCAPED AND SCREENED FROM VIEW.
• MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING AIR CONDITIONING UNITS, SHALL BE
DESIGNED, INSTALLED AND OPERATED TO MINIMIZE NOISE IMPACT ON SURROUNDING
PROPERTY. ALL SUCH EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW.
• THE MASONRY REQUIREMENTS OF SECTION 54 SHN_L BE MET.
• ALL ONSITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSTRUCTION SHALL BE
LOCATED UNDERGROUND.
• ILLUMINATED SIGNAGE WAS INCLUDED IN THE TERMINATION OF THE ILLUMINATION LEVELS.
NO OTHER ILLUMINATION PROPOSED TO BE ADDED WITH SU22-02.
EXISTING MONOPOLE
x x x x x x x x x x x x x x x x
EXISTING AT&T METER
x AND PRIMARY DISCONNECT
0
0
co _
x [
X
` EXISTING FENCE
x
— x------ x'--__ --- x x
12.00'
CONSTRUCTION LEGEND
r EXISTING AT&T SHELTER
x ^x�x x x X X
EXISTING ICE
BRIDGE (TIP.)
1
I
0
EXISTING TELCO/ALARM —
I (VERIFY LOCATION) U
I Ir- — — — —
I IIII
, 14
I
O
x
�oo �o
0
a�
x
—I EXISTING POWER PANELxx
x x x Al
3.00' 10.00' j 3.00'
16.00'
I STING MTS
— — — — — — — — IIII
_J II
— x x � mac—
� x
4.00'
I 111
EXISTING PLATFORM
4.00'
A. INSTALL NEW DIESEL GENERATOR PER MANUFACTURERS SPECIFICATIONS IN
LEASE AREA.
B. PROPOSED AT&T UNDERGROUND ELECTRICAL SERVICE & CONTROLS FROM
GENERATOR TO EQUIPMENT INSIDE SHELTER, SEE SHEET E-1. FIELD LOCATE
EXISTING UTILITIES & GROUND RING. SAW CUT ASPHALT FOR CONDUIT RUN
AND REPLACE.
C. 1 — #2 AWG BARE TINNED GROUND WIRE TO EXISTING SITE GROUND RING.
GROUND GENERATOR PER MANUFACTURERS RECOMMENDATIONS.
D. REMOVE EXISTING GEN. PLUG AND INSTALL AUTOMATIC TRANSFER SWITCH
E. REMOVE FENCE SETCTION (10')
F. SET NEW FENCE TO MATCH EXISTING FENCE (6'-0")
r
f
IS - E
GRAPHIC SCALE
1 inch = 6 feet (I I "x 17')
3 6
GENERAL 0VNAMICS
Wireless Services
12906 SHELBYVIU.E ROAD, STE. 230
LOUSMLLE. KY 40243
502-653-6963
DRAWING REVISIONS
REV. DESCRIPTION DATE
By
1 GEN. RELOCATION 11/10/21
MCB
2 ADD SIG BLOCK 1/20/22
DSB
3 ADD OVERALL SrTE PLAN 2/17/22
DSa
4 REV, PER SU 22-02 3/18/22 REV. LETTER 3/28/22
DSB
5 REV, REAR 15' ESMT. 3/31/22
DSB
6 REV. PER E MAROHNIC $3022 4/6/22
OSB
7 REV. LEASE AREA 4/7/22
DS8
* ........ : •
.... .................
DANIEL SCOTT BORDENET
126055
I�;o� •� /f cnISF� .�dw�
CERDFICATE OF REGISTRATION UNDER BORDENEr
CONSULTING, U.C. REGISTRATION NUMBER F-18788.
89M ACIBECK Cr., INDPLS., IN 46256. 317-840-6532.
SHEET NAME:
SITE PLAN
0o PROJECT DESCRIPTION
This project proposes to extend the ground lease
area of an existing monopole tower and ground
equipment for the purposes of adding a backup
generator.
CASE NAME: AT&T CELL TOWER
CASE NUMBER: SU22-02
LOCATION: 525 INDUSTRIAL BOULEVARD.
MAYOR
SECRETAERY
DATE
PLANNING & ZONING COMMISSION
CHAIRMAN
DATE APMAL DOES NOT AIMW2E AN WORK IN
CANRICT WITN CODES OR ORDINAACES
DEPT. OF PAWNING SERVICES
HWY 114/INDUSTRIAL GENERATOR UPGRADE SITE PLAN
FA#:10011197
525 INDUSTRIAL BLVD.
GRAPEVINE, TX 76051
Lot 3 of First Section of Grapevine Industrial Park
VoL 388.140, Pg. 84 Deed Records of Tarrant County Texas
Ambrose Foster Survey, Abstract No, 5186
Site No. 80486061, Instr. No. D210182070
Date of Preparation: March 28th, 2022
SHEET NO.: REVISION
NUMBER
2OF6 1 4
4-�','RAL 1, L.v i�IE+,l� kF.tGMi
E— rJ .+1
AT&T EQUIPMENT (NO
�— CHANGES THIS PROJECT)
au�tuua HRIS>N' 1 VERIZON EQUIPMENT (NO
-'= I CHANGES THIS PROJECT)
i
I
I
f171 7T:,.-6" W0144KXE %W[R_—
t
I
a
s
1
EXISTING TOWER PROFILE
14
ata
GENERAL dYNAMICS
Wireless Services
12906 SHELBYVILLE ROAD, STE. 230
LOUSMLLE. KY 40243
502£53-6963
DRAWING REVISIONS
REV.
DESCRIPTION DATE
BY
1
GEN. RELOCATION 11/10/21
MCB
2
ADD SIG BLOCK 1/M/22
OSB
3
ADD OVERALL SITE PLAN 2/17/22
OSS
4
REV, PER SO 22402 3/ 1 B/22 REV. LETTER 3/28/22
OSS
5
REV, REM 15' ESMT. 3/31/22
OSS
5
REV. PER E MAROHNIC 330-22 4/6/22 I
OSS
7
REV. LEASE AREA 4/7/22 I
OSS
*:
................................
:*
DANIEL SCOTT BORDENET
...............................
126055
CEnFOTE OF REGISTRATION UNDER BORDENEf
CONSULTING, LLC. REGISTRATION NUMBER F-18788.
M AUBECK CT., INWI.S., IN 462M. 317-840-6532.
SHEET NAME:
EXISTING TOWER PROFILE
PROJECT DESCRIPTION
This project proposes to extend the ground lease
area of an existing monopole tower and ground
equipment for the purposes of adding a backup
generator.
CASE NAME: AT&T CELL TOWER
CASE NUMBER: SU22-02
LOCATION: 525 INDUSTRIAL BOULEVARD.
MAYOR
SECREfAERY
DATE
PLANNING & ZONING COMMISSION
OMRMAN
DATE
APPRDYAL DOES NOT AUTHRA MY WORK IN
COME XT * Rf CODES OR ORDItuaNZ
DEPT. OF PLANNING SERVICES
HWY 114/INDUSTRIAL GENERATDR UPGRADE SITE PLAN
FA#:10011197
525 INDUSTRIAL BLVD.
GRAPEVINE, TX 76051
Lot 3 of First Section of Grapevine Industrial Park
Vol. 38&140, Pg. 84 Deed Records of Tarrant County Texas
Ambrose Foster Survey, Abstract No. 5188
Site No. 80486061, Instr. No. D210182070
Date of Preparation: March 28th, 2022
SHEET NO.. REVISION
NUMBER
30F6 1 4
J
\ - a=
8 ( 7 I 6 I 5 4 I 3 I 2 I ! GENERAL MYNAMICS
NOTES : Wireless Services
MINIMUM REOUIRED CLEARENCE FOR AIRFLOW 12906 SIELEM4LLE ROAD, STE. 230
I THE RIGHT SIDE OF THE GENERATOR IS SERVICE ACCESSIBLE. LOLISMLLE, KY 40243
2. 6 AMP BATTERY CHARGER, -•--•--------------••-••-•--•-- 502�53-sss3
3. 120VAC ENGINE BLOCK HEATER.
4, 120VAC 8OW BATTERY HEATER DRAWING REVISIONS
5. GENERATOR MUST BE GROUNDED. o
6. SOUND ATTENUATED ENCLOSURE STANDARD WITH GENERATOR. °O (MM, TV.)
N� REv. oEEXcnFn7N oATE BY
7. MUST ALLOW FREE FLOW OF DISCHARGE AIR AND EXHAUST. my 242.4 _ M 1 GEN.RELExanoN 11/10/21 MCS
8. MOST ALLOW FREE FLOW OF INTAKE AIR. [9.55] 2 ADD SIG BLOCK 1/20/22 ose
9. EASY ACCESS SERVICE PANEL IS LOCATED ON THE RIGHT SIDE OF THE GENERATOR ONLY. (IN TYP,) -/! 3 ADO OVERALL SITE PLAN 2/17/22 ose
D 10. BASE TANK REQUIRES ALL STUB -UPS TO BE IN THE REAR TANK STUB -UP
AREA. I U a REV. PERSU22-023/18/22REV. LETTER a/ze/zz ose
11. SEE TABLE FOR SUBBASE FUEL TANK CAPACITY. s REV. PERSU22-MT. 3/2/22 DSB
12. IT IS THE RESPONSIBILITY OF THE INSTALLATION TECHNICIAN TO ENSURE
THAT THE GENERATOR INSTALLATION COMPLIES WITH ALL APPLICABLE 8 REV. PER E.MAROHNIC33E}22 4/8/22 ose
CODES, STANDARDS, AND REGULATIONS. 7 REV. LEASE AREA 4/7/22 ose
13. GENERATOR IS INSTALLED ON A UL-142 RATE DOUBLE WALL SUBBASE FJEL TANK. "A El o
OP * �,
°..*.:..........................:'.W.
DANIEL SCOTT BORDENET
�............ i
s2s z AIR DISCHARGE �l°' 126055
[ 32. 531
> /ZZ I e_�6�
C CERTMTE OF REGISTRATION UNDER BORDQIET
CONSULTING, LLC. REGISTRATION NUMBER F-18788.
W AUBECK CT., INDPLS., IN 46256. 317-840-6532.
_ M SHEET NAME:
1968.7_ _ - N a SHOWN WITH BRACING
[77.511 _ INSTALLED FOR 12' GENERATOR DETAILS
p V 5-1/2W ABOVE GRADE VENTS. PROJECT DESCRIPTION
+• I I This project proposes to extend the ground lease
area of an existing monopole tower and ground
XX ti REMOVABLE ALTERNATOR a equipment for the purposes of adding a backup
• o ACESS PANEL p o generator.
• >•
• W N
N
Olth
> •< O V
0 o AIR INTAKE DUCTS
P R a
r E� I ^ ' - � �• ,� °� •_ •� . j �,�--�� CASE NAME: AT&T CELL TOWER
CASE • o o W. LOCATION:
525
NUMBER: 2-02
INDUSTRIAL BOULEVARD.
C O ® IEa�ao 4 O ..::rK O ® O J
s�.reaK '
- ND a
°aIu er o o �. MILND - MAYOR
ND OPEMMl�lir
Na MrNpM f nEt v aE>5n �.
Y SECRETAERY
�a AIR INTAKE DUCTS 1092.1 [43.001 a
LIFT OFF SERVICE PANEL COOLANT DRAIN
2575.0 W / LOCKABLE LATCHES DATE
[ 1 0 1. 381 _ 1529.2 [60.201 PLANNING $ ZONING COMMISSION
8' 5-3/8' OIL DRAIN CHAIRMAN
NOTE: TANK SHOWN IN THESE DRAWING VIEWS IS CONFIGURED FOR
WA. STATE WITH DUAL 120' ABOVE GRADE NORMAL VENTS. THESE DATE
ITEMS NOT INCLUDED IN ALL STATE CONFIGURATIONS, A
S OFu CANtilG7 N1ni CODE$ OR ORaNtA
IREVI DATE ON COMPOSITE DWGS. SEE PART NO. FOR REVISION LEVEL BY IuYEEST Oixr-F sP onED Olnl� IMETRIC 1 PRO•E
II RIYEYS-I,"'IY YIILIYEI[AS K i� C
7-13-16 NEW DRAWING ICT1524767 JMR el saEA+.cn +AE.
=.IX 4 0 ]5 POWER SYSTEMS. MOHLER, WI 53044 U.S.A. OF PLANNING S
ERVICIES
I.9 ssYEu[ rlxlsY THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.
_ +MOLES 4 0' JO' PROPERTY AND MUST NOT BE USED EXCEPT IN
GENSET TANK P/N TANK HT III NNA pNl DESCRIPTION ASS WEIGHT MN CONNECTION WITH KOHLER Co. WORK. Au RIGHTS OF HWY114/INDUSTRIAL GENERATOR UPGRADE SITE PLAN
= DESIGN OR INVENTION ARE RESERVED.
20REOZK GM101667-MA2 558.8 [22.0] SKID/WA ST TANK 148 GAL 984 KG [2170 LBS] ! I ;+=•wm �_� FA#:10011197
20REOZK GM101667-MAI 558.8 (22.0] SKID/ST TANK 148 GAL_ 984 KG 12170 LBS] l I APPROVALS DATEDIMENSION T PRINT, KUND ETM
�_ I AT&TAST TANK W/SOUND ENCL 525 INDUSTRIAL BLVD.
30REOZK GM101667-MA21 558.8 [22.0] SKID/WA ST TANK 148 GAL 1051 KG (2316 LBSI 30KW KOHLER DIESEL (7 ---- ( I<.�+< JNRI7-13-I6 MubO.oe =,,, NE7 GRAPEVINE, TX76051
SOUND ENCL W/ LIFT OFF PANEL ! __ !MR i I3-I6 Yw
30REOZK I6M101667 MAI 558.8 [22.0] SKID/ST TANK 148 GAL 984 KG [2170 LBS] I --i-f °' L8D t 13-16 ADV-8918 D
I Lot 3 of First Section of Grapevine Industrial Park
8 I 7 I 6 I 1 4 I 3 I 2 I I Vol 388.140, Pg. 84 Deed Records of Tarrant County Texas
e Ambrose Foster Survey, Abstract No. 5188
Site No. 80486061, Instr. No. D210182070
Date of Preparation: March 28th, 2022
SHEET Na: REVISION
4 OF 6 NU ER
8 I 7 I 6 5
/-(MM, TV.)
2575.0 _
1 101 .383
890_0 530.3 4X 0 25. 4 [ I .001
to 90.04] [20.88] (IN, M.) BOTTOM FLANGE
cvlo TANK MOUNTING
�•r 1 52. 4 [ 6. 001
STUB -UP REF
J I
0 0 0 o ° o 0 0 o a _ I [
zI---------------------1-------------le-- ---IIA z [
W JW ® 1 O ° ° W
oh Sao N — D ❑
a o m
wmm �o DO Go 01 ] �o oco
0
W FAE] Mu oM
u Q nC Opu
W I ®H E• O B� a — II
"--------------------------- - - - - --
----- -- - r
0 0 0 0 0 0 0
292.1 111.503
N o GEN REF.
n 1968.5 177.503 162.0 [6.381
4,5 ti u 147.9
INNER TANK REF. —'— '1 RAD. REF.
Co.18i ' 15.823
CONDUIT ENTRY AREA
FOR GENERATOR LOAD
LEADS (BOTTOM ENTRY)
REMOVABLE
END CHANNEL
3 , 0
M 11� 10161
� to WENO SMIXIM
'r PBIFLAWAIE,S
1r orER
(ISM, Tr.)_QI
208.6
[8.217 [76.001
(IN, TYP.) _ 12FUEL INLET91
_
A
8 1 7 I 6
1 4
3
070.0 B.C.
[2.761
EXHAUST FLANGE DETAIL \ \ 3X M81X1.25 STUDS
a O
122.8 [4.83]
FUEL INLET -' -
1436.4 156.551
EXHAUST FLANGE
2
TANK FITTINGS.
A. 3" NPT EMERGENCY VENT FITTING PER NFPA 30
WITH VENT CAPS (OTY 2).
B. 4" NPT FUEL FILL FITTING WITH 5 GAL SPILL BOX
AND 95% OVERFILL PREVENTION VALVE.
C. 2" NPT FITTING FOR FUEL LEVEL SENDING UNIT
WITH MECHANICAL INDICATOR NEEDLE.
D. 2" NPT NORMAL VENT FITTING WITH MUSHROOM VENT
CAP AND 138" RISER. (OTY 2)
E. 112•' NPT FITTING REMOVABLE ENGINE SUPPLY
DIP TUBE (318" NPT WITH CHECK VALVE.
F. 112" NPT FITTING REMOVABLE FUEL RETURN
DIP TUBE (3/8" NPT FEMALE).
G. 2" NPT FITTING FOR HIGH FUEL LEVEL ALARM
SWITCH (SET AT 90% FULL).
H. 2" NPT FUEL LEVEL SENDING UNIT.
N. 2" NPT FOR FUEL IN BASIN SWITCH
NOTE: TANK SHOWN IN THESE DRAWING VIEWS IS CONFIGURED FOR
WA. STATE WITH DUAL 12' ABOVE GRADE NORMAL VENTS, THESE
ITEMS NOT INCLUDED IN ALL STATE CONFIGURATIONS.
NOTE. IREVI DATE ON COMPOSITE OWES. SEE PART N0, FOR REVISION LEVEL BY °DiSRDl.fps'i [S,iLMiLt DN I[a5 KOHLER CQ ITR��
7-13-16 NEW DRAWING ICT1524761 JMR 11 Izf:S Sot
FOR FURTHER TANK DETAIL �o.a HIS STSTCMS, soHLER. MI 53011 u s A
R THIS DRAPING IN DESIGN AND DE iAII IS KOHLER CO.
SCE INDIVIDUAL DRAWINGS AN.Lfs t C }1 SURF STIse PROPERTT AND MUST NOT BE USED EXCEPT IN
MAX CONNECTION °ITN KOHLER CO MORN ALL RIGHTS OF
4 X 025. 4 [ I . 0 0 ] DESIGN OR INVENTION ARE RESER'JED.
■STANDARD MOUNTING i i I "°"`�' DIMENSION PRINT KD12504TM
I I (IDAP.PROVALS I DATE AT&T ST TANK W/SOUENCL.
III JI� MRl 7-13-16 s• , o Io
301(W KOHLER DIESEL " JNA 7-13-16 N. .o n_ 'NL'2 r 3
�t"'OYtp LED 7- 1 3- 16 µ eo ADV-8918 t TD
5 t 4 I 3 I 2 I 1
�l
1
GEIMERAI.N dYNAM=S
Wireless Services
12906 SHELBYVILLE ROAD, STE 230
LOUSMLLE, KY 40243
502-653-6363
DRAWING REVISIONS
REV.
OESCRIP ION DATE
BY
1
GEN. RELOCATION 11/10/21
MCB
2
ADD SIG BLOCK 1/20/22
OSB
3
AM OVERALL SITE PLAN 2/17/22
OSB
U 4
REV, PER SU 22-02 3/18/22 REV, LETTER 3/28/22
DSB
5
REV. REAR 15'ESMT, 3/31/22
DSB
5
REV. PER E. MAROHNIC 330-22 4/13/22
DSB
7
REV. LEASE AREA 4/7/22
DSB
...........
.c s��l
DANIEL SCOTTTTTT BORDENET
................................
126055
CERTMTE OF REGISTRATION UNDER BCRDENET
CONSULTING, U.C. REGISTRATION NUMBER F-18788.
8902 AIBECK CT., INDP[S., IN 46256. 317-840-6532.
SHEET NAME:
GENERATOR DETAILS
PROJECT DESCRIPTION
This project proposes to extend the ground lease
area of an existing monopole tower and ground
4 equipment for the purposes of adding a backup
generator.
CASE NAME: AT&T CELL TOWER
CASE NUMBER: SU22-02
LOCATION: 525 INDUSTRIAL BOULEVARD.
MAYOR
SECRETAERY
DATE
PLANNING dE ZONING COMMISSION
CHAIRMAN
A DATE APPPAL DOTS NOT WHOIRK ANY WON( N
MWWI I.M CM NI (TOMM
DEPT. OF PLANNING SERVICES
HWY 114/INDUSTRIAL GENERATOR UPGRADE SITE PLAN
FA#:10011197
525 INDUSTRIAL BLVD.
GRAPEVINE, TX 76051
Lot 3 of First Section of Grapevine Industrial Park
Vol. 388140, Pg, 84 Deed Records of Tarrant County Texas
Ambrose Foster Survey, Abstract No, 5188
Site No. 80486061, Instr. No. 0210182070
Date of Preparation: March 28th, 20R2
SHEET NO.: REVISION
5 OF 6 NU ER
X
C
B
8 1 7
NOTE:
THIS GENERATOR SET HAS FRONT ACCESSIBILITY TO ALL
ROUTINELY SERVICED COMPONENTS INCLUDING:
I. AIR FILTER
2. OIL FLTER / FILL
3. FUEL FILTER
4. OIL DRAIN
5. COOLANT DRAIN
ENGINE OIL -
FILTER HOUSING
AIR CLEANER
RESTRICTION INDICATOR
AIR CLEANER
HOUSING
DEC 3000—,
CONTROL PANEL o0
LOAD CIRCUIT
BREAKER 150A
:o O
wo
FUEL FILTE
8 1 7
6
'FREEZE PLUG BLOCK
HEATER LOCATED BEHIND
OIL FILTER HOUSING
OIL FILL
RADIATOR FILL
I ,
L
O
NO SMMNS
1 NO�0 �RJMESS x
COOLANT DRAIN VALVE
OIL DRAIN VALVE
CRANKCASE OIL
DIPSTICK
6
5 1 4
BATTERY
DETAIL A
BATTERY CHARGER
PUBLICATIONS AND
MANUAL CASE
L_
J�A_0
a�
0
30KW KOHL.ER DIESEL
5 t 4
3
12V, 6AMP
BATTERY CHARGER
0-135V POWER CHORD
ENGTH 1829 (72.01
2 ( GGIVERAL 1113PYTY AMMS
Wireless Services
12906 SHELEYVILLE ROAD, STE. 230
LOUSMLLE, KY 40243
502-653-6953
DRAWING REVISIONS
REV. DESCRIPTION DATE BY
1 GEN. RELOCATION 11/10/21 MCB
2 ADD SIG BLOCK 1/20/22 DSB
3 ADO OVERALL SITE PLAN 2/17/22 OGG
L 4 REV. PER SU 22-02 3/ 1 B/22 REV. LETTER 3/28/22 DSB
5 REV. REAR 15' ESMT. 3/31/22 DSB
6 REV. PER E. MAROHNIC 3-30.22 4/6/22 DSB
7 REV. LEASE AREA 4/7/22 OSB
OF
i.::..............................�
DANIEL SCOTT BORDENET W
�.................................i
126055
�11`'� •' �•7 C E NSF:�G��rr
'E
CW MATE OF REGISTRATION UNDER BUMEr
CONSULTING, LUC. REGSTRATION NUMBER F-18788.
8902 A1BED( CT, INDPLS., IN 46256, 317-8404532.
SHEET NAME:
GENERATOR DETAILS
PROJECT DESCWPTION
This project proposes to extend the ground lease
SEE DETAIL A area of an existing monopole tower and ground
-0 equipment for the purposes of adding a backup
generator.
p.w _UeT
CASE NAME: AT&T CELL TOWER
CASE NUMBER: SU22-02
_
LOCATION: 525 INDUSTRIAL BOULEVARD.
O
O
C
OO
® ra FUR IT On61
AL
ele em
MAYOR
ND 9X= CXL VU —
n TsND O> erm-A" fey
SECRETAERY
DATE
PLANNING do ZONING COMMLSSION
CHAIRMAN
NOTE; TANK SHOWN IN THESE DRAWING VIEWS IS CONFIGURED FOR
WA. STATE WITH DUAL 12' ABOVE GRADE NORMAL VENTS, THESE
ITEMS NOT INCLUDED IN ALL STATE CONFIGURATIONS. A
DATE
APPAOYAL DOES NDT AUMRfZE ANY MDRK dV
IREVI DATE ON COMPOSITE DOGS, SEE PART
NO FOR REVISION LEVEL I BY xNt[550[x[RNIS[ 5xf[IFI[D KOHLER CQ IMETRIC ! PRO-E
Dutxslws Av[ n xu ixFT[vs
CpyfW NN CM OR �
- 1-13-16 NEW DRAWING [CT152di67
JMR ii ra[nNX[s u[
POMER SYSTEMS, NONLER, y, SJDA9 b s a
-- I.D SeRFx(F FIx15x THIS DRAWING IN DESIGN AND DC TAIL IS NOIILCR CO.
ixOLES PRONECTI AND MUST NOT 6E USED EXCEPT IN
DER. OF PLAINING SERVICES
! C JD' RisNTs o�
"AA DEOSNGXTOR"Isv[NTNON`ARE RL
HVVY114/INOUSTRIA#:1001119 UPGRADE SITE PLAN
ER'ED.ALL
"' DIMENSION PRINT KD12504TM
FA#: 10011197
I
I APPROVALS I DATE AT&T ST TANK W/SOUND ENCL
525INDUSTRIAL BLVD.
JMR 7-13-16 ---
IN R_L 7-13'16
GRAPEVINE, TX76051
° LBD 7. 3 - 6 w w ADV-8918 r
Lot 3 of First Section of Grapevine Industrial Pant
3
I 2� I !
Vol 388-140, Pg. 84 Deed Records of Tarrant County Texas
Ambrose Foster Survey, Abstract No. 5188
Site No. 80486061, Instr. No. D210182070
Data of Preparation: March 28th, 2022
SHEET NO.: REVISION
NUMEIER
6OF6 4