Loading...
HomeMy WebLinkAboutNSFR2012-3110=0 ,,GRA EI M, 7'y E X 'A S 0.. DATE OF ISSUANCE: SEP 10 2012 PERMIT #:— 0 BUILDING PERMIT APPLICATION PLEASE PRINT JOB ADDRESS: 416 Brewer Street SUITE # - LOT: 11A BLOCK: - SUBDIVISION: North Side Addition BUILDING CONTRACTOR (company name): Avery Homes LLC CURRENT MAILING ADDRESS: 1301 Mt. Gilead Rd. CITY /STATE /ZIP: Keller, TX 76262 PH: # 214 -212 -0558 Fax# 817- 251 -4815 PROPERTY OWNER: Same CURRENT MAILING ADDRESS: same CITY /STATE /ZIP: PHONE NUMBER: PROJECT VALUE: $ 170,000 FIRE SPRINKLERED? YES NO X DESCRIPTION OF WORK TO BE DONE: New Single Family Residence USE OF BUILDING OR STRUCTURE: Residence NAME OF BUSINESS: -- **Total Square Footage under roof: 2202 Square Footage of alteration /addition: I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department (required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review. Control Number: (Not required for 1. & 2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS, ADDITIONS AND OR ALTERATION TO COMMERCIAL. AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. it is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPEll , 'SSIBILITY BY THE CITY, AND THAT THE DESIGN PROFESSIONAL /OWNER IS RESPONSIBLE FOR OBTAINING SUCH AP OV: L F O THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Jeff Avery SIGNATURE PH #: 214-212-0558 FAX #: 817- 251 -4819 EM _, ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E -MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: Permit Valuation: $ &j Setbacks Approval to Issue Occupancy Group: Front: ` Electrical Division: Building Width: Left: Plumbing Zoning: S. Building Depth: Right: Mechanic Rear: Plan Review Approval: Date: tZ Water Availability Rate: '1 LDq Site Plan Approval: Date: Sewer Availability Rate:(j Fire Department: Date: Building Permit Fee: , Public Works Department: Date: Plan Review Fee: Health Department: Date: Lot Drainage Fee: )Z) Approved for Permit: Date: Total Fees: Lot Drainage Submitted: pproved: 4jp 4 Total Amount Due: .0.13OX 95104, GRAPEVINE, T1,76099 (.;'I;)410-3165 v 0TORMS•DSPERMITAPPLICIMONS, 1 /2 /02 -R-11- 04,5 -0u",X$7,11 -09 o j_�_ I �_ ( LP 0 2 u I f CITY OF GRAPEVINE T S MECHANICAL ELECTRICAL PLUMBING FUEL GAS PERMIT APPLICATION _ (PI FASF PRINT) 0f. I 2S 2AI? PERMIT # y BLDG. PERMIT # DATE: JOB ADDRESS: SUITE # (S e✓' DESCRIPTION OF WORK: PROPERTY OWNER: CONTRACTING COMPANY: ,i- E/ec t�faY. ADDRESS: ADDRESS: a tip l t CITY /STATE /ZIP: CITY /STATE /ZIP: TA —7 Vin , PHONE NUMBER: PHONE NUMBER: W TYPE OF OCCUPANCY BUILDING AREA (SO FT) PERMIT FEES AMOUNT DUE EACH TRADE I. R -3 1- 749 $ 33.25 SINGLE FAMILY, DUPLEX 750— 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION & 1,501- 1,750 $ 76.48 ADDITIONS (PER UNIT) 1,751- 2,000 $ 83.13 2,001- 2,250 $ 89.78 TOTAL SQ.FOOT UNDER ROOF 2,251- 3,000 3,001- 3,500 $ 96.43 $ 103.08 Q Q 3,501- 4,000 $ 109.73 $ v F 4,001+ $ 120.37 -- EACH TRADE II. A, E, I, R -1 1- 500 $ 37.00 HOTELS, APARTMENTS, 501 — 100,000 $ 17.50 +.035 PER DRINKING /DINING, 100,001 — 500,000 $ 3,500.00 +.03 SQUARE EDUCATIONAL, ASSEMBLY, 500,001 + $15,000.00 +.02 FOOT $ INSTITUTIONAL EACH TRADE III. B, F, H, M, S, U 1- 500 $ 37.00 OFFICE, RETAIL, WHOLESALE, 501- 50,000 $ 32.00+.01 PER 1 GARAGES, FACTORIES, 50,001- 100,000 $ 182.00+.007 SQUARE WORKSHOPS, SERVICE 100,001+ $ 582.00+ .003 FOOT $ STATIONS, WAREHOUSE CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH -OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+.009 50,001- 100,000 $ 127.00+ .007 PER $ 100,001- 500,000 500,001+ $ 327.00+ .005 DOLLAR $ 1,327.00+.003 TVALUATION $ EACH TRADE V. MISCELLANEOUS IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 $ O: \FORMS \DS APPLICATIONS - FEES \MEP APPLICATION 4- 11.doC PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM ) ............................ ...................$42.00 /HOUR • REINSPECTION FEES ................................................................................... ............................... $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED ............................ ............................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM) .. ....................$42.00 /HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO APPROVEDPLANS .................................................................... ............................... ....................$42.00 /HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE - COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS " I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND I OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT PRINTED NAME (OR HOMEOWNER FOR HOMEOWNERS PERMITS) PHONE EMAIL: "OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. - ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. CITY OF GRAPEVINE, BUILDING INSPECTIONS, P. O. BOX 95104, GRAPEVINE, TX 76099 (817) 410 -3165 6/21/01 REVISED 10/01, 5/06, 2/07, 7/07, 8/09, 11/09, 4/11 OAFORMS \DS APPLICATIONS - FEES \MEP APPLICATION 4- 11.doc S E P 14 2012 CITY OF GRAPEVINE MECHANICAL ELECTRICAL PLUMBING FUEL GAS PERMIT APPLICATION (PLEASE PRINT) PERMIT # BLDG. PERMIT # -311 DATE: JOB ADDRESS: t SUITE # DESCRIPTION OF WORK:, n. ll" PROPERTY OWNER: C RACTING COMPANY: r- . ." vjd ADDRESS: ADDRFU%S© e>ox f s.c� If CITY /STATE /ZIP: CITY / ATE /ZIP: E tx 7003 PHONE NUMBER: PHONE ' l ^o / �- ABER: TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES AMOUNT DUE (SQ FT) EACH TRADE I. R -3 1- 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION & 1,501- 1,750 $ 76.48 ADDITIONS (PER UNIT) 1,751- 2,000 $ 83.13 2,001 - 2,250 $ 89.78 TOTAL SQ.FOOT UNDER 2,251- 3,000 $ 96.43 ROOF 3,001- 3,500 $ 103.08 Q� I� 7�/ '7 3,501- 4,000 $ 109.73 $ f' �nk ` 4,001+ $ 120.37 EACH TRADE II. A, E, I, R -1 1- 500 $ 37.00 HOTELS, APARTMENTS, 501 - 100,000 $ 17.50 +.035 PER DRINKING /DINING, 100,001 - 500,000 $ 3,500.00 +.03 SQUARE EDUCATIONAL, ASSEMBLY, 500,001 + $15,000.00 +.02 FOOT $ INSTITUTIONAL EACH TRADE III. B, F, H, M,S,U 1- 500 $ 37.00 OFFICE, RETAIL, WHOLESALE, 501- 50,000 $ 32.00+.01 PER 1 GARAGES, FACTORIES, 50,001- 100,000 $ 182.00+.007 SQUARE WORKSHOPS, SERVICE 100,001+ $ 582.00+ .003 FOOT $ STATIONS, WAREHOUSE CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH -OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+.009 50,001- 100,000 $ 127.00+ .007 PER $ 100,001- 500,001+ 500,000 $ 327.00+ .005 DOLLAR $ 1,327.00 +.003 TVALUATION $ EACH TRADE V. MISCELLANEOUS IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 $ O_ \FORMS \DS APPLICATIONS - FEES \MEP APPLICATION 4- 11.doc PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM ) ............................ ...................$42.00 /HOUR* • REINSPECTION FEES ................................................................................... ............................... $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED ............................ ............................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM) .. ....................$42.00 /HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO APPROVEDPLANS .................................................................... ............................... ....................$42.00 /HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE - COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS" I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT .,CATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. SIGNAT E OF C NT CTOR OR AUTHORIZED AGENT PRINTED NAME (OR HOMEOWNER HOMEOWNERS PERMITS) PHONE* I l .� L? EMAIL: *OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. - ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. CITY OF GRAPEVINE. BUILDING INSPECTIONS, P. O. BOX 95104, GRAPEVINE, TX 76099 6/21/01 REVISED: 10/01, 5/06, 2/07, 7/07, 8/09, 11/09, 4/11 O: \FORMS \DS APPLICATIONS - FEES \MEP APPLICATION 4- 11.doC (817) 410 -3165 1� - -- T r E A LCITY OF GRAPEVINE _ A_� ECTRICAL PLUMBING FUEL GAS PERMIT APPLICATION (PI FARF PRINT) PERMIT # `� ��� 9 (o 7 BLDG. PERMIT # 1 2 ` DATE: (0 d i JOB ADDRESS: 416 /1IQ�_ SUITE # DESCRIPTION XZS u, n C PROPERTY OWNER: �pQ. CONTRAC COMPANY: �(l ADDRESS: ADDRESS: Ca 7Co SA•�- d f-� ,�( CITY /STATE /ZIP: CITY /STATE /ZI PHONE NUMBER: PHONE NUMBERL� w /3 Y d - TYPE OF OCCUPANCY BUILDING AREA (SQ FT) PERMIT FEES AMOUNT DUE EACH TRADE I. R -3 1- 749 $ 33.25 SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88 TOWNHOUSE, 1,200- 1,500 $ 63.18 NEW CONSTRUCTION & 1,501- 1,750 $ 76.48 $ 83.13 ADDITIONS (PER UNIT) 1,751- 2,000 89.78 2,001 - 2,250 $ TOTAL SQ.FOOT UNDER 2,251- 3,000 3,001 - 3,500 $ 96.43 $ 103.08 �L[� ROOF $ p 3,501- 4,000 $ 109.73 Lill 4,001+ $ 120.37 -- �— EACH TRADE 1 II. A, E, I, R -1 CY- 1- 500 $ 37.00 HOTELS, APARTMENTS, 501 - 100,000 $ 17.50 +.035 PER DRINKING /DINING, 100,001 - 500,000 $ 3,500.00 +.03 SQUARE EDUCATIONAL, ASSEMBLY, 500,001 + $15,000.00 +.02 FOOT $ INSTITUTIONAL EACH TRADE III. B, F, H, M, S, U 1- 500 $ 37.00 OFFICE, RETAIL, WHOLESALE, 501- 50,000 $ 32.00+.01 PER 1 GARAGES, FACTORIES, 50,001- 100,000 $ 182.00+.007 SQUARE WORKSHOPS, SERVICE 100,001+ $ 582.00+.003 FOOT $ STATIONS, WAREHOUSE CONTRACT EACH TRADE IV. ANY OCCUPANCY GROUP VALUATION OF WORK FINISH -OUTS, SHELL COMPLETIONS, 0- 500 $ 37.00 ALTERATIONS OR 501- 1,500 $ 45.00 STAND ALONE PERMITS 1,501- 3,000 $ 57.00 3,001- 5,000 $ 72.00 CONTRACT VALUATION OF WORK: 5001- 50.000 $ 27.00+.00 9 $ 50,001 100,000 100,001- 500,000 $ 27.00+ .007 PER $ 327.00+ .005 DOLLAR $ 500,001+ $ 1,327.00+ .003 VALUATION EACH TRADE V. MISCELLANEOUS IRRIGATION SYSTEMS $ 37.00 MOBILE HOME SERVICE $ 37.00 TEMPORARY POLE SERVICE $ 37.00 SWIMMING POOLS $ 37.00 SIGN ELECTRIC $ 37.00 $ O: \FORMS \DS APPLICATIONS - FEES \MEP APPLICATION 4- 11.doc PLAN SUBMITTAL: WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE OTHERWISE REQUIRED BY STATE LAW. OTHER INSPECTIONS AND FEES: • INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS (2HR MINIMUM ) ............................................... $42.00 /HOUR* • REINSPECTION FEES ................................................................................... ............................... $42.00 • PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED ............................ ............................... $37.00 • INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM) .. ....................$42.00 /HOUR • ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES, ADDITIONS, OR REVISIONS TO APPROVEDPLANS .................................................................... ............................... ....................$42.00 /HOUR • BUILDING PERMIT FEES FOR THE GRAPEVINE - COLLEYVILLE INDEPENDENT SCHOOL DISTRICT SHALL BE 25% OF THE FEES ESTABLISHED IN THIS TABLE • FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH......... ACTUAL COSTS" I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF GRAPEVINE. I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS, AND THAT VERIFICATION OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST. SIGNATURE OF COKRAgTOR OR AUTHORIZED AGENT (OR HOMEOWNER F OMEOWNERS PERMITS) PHONE #: 011 tiv 1, aA ///t` ' PRINTED NAME EMAIL: "OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER. ""ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS. CITY OF GRAPEVINE, BUILDING INSPECTIONS, P. O. BOX 95104, GRAPEVINE, TX 76099 6/21/01 REVISED: 10/01, 5/06,2/07,7/07, 6/09, 11/09, 4/11 O:IFORMS \DS APPLICATIONS - FEES\MEP APPLICATION 4- 11.doc (817) 410 -3165 Zwo C/) II, N O D z N t, o ��{ z z �I o (i) 416 BREWER STREET 57.33' PROPERTY LINE T 25' O w N I a? C� C3 Oz r7 FTJ t4 0 �N O n� D f 25' REAR B.L IFT] � �t ewef � I EX. 5' U. E. J 0 1. EROSION CONTROL REQUIRED BEFORE CONSTRUCTION STARTS. 2. NO CONSTRUCTION, FILLING, CUTTING, OR GRADE CHANGE IN EASEMENT WITHOUT PRIOR APPROVAL. 3. GRASS /EROSION CONTROL REQUIRED BEFORE FINAL. 12._310 q14 - SFk. I IO C� � VI CD I r- o0o�c_- �' iU� ✓� m 71 X IFT] � �t ewef � I EX. 5' U. E. J 0 1. EROSION CONTROL REQUIRED BEFORE CONSTRUCTION STARTS. 2. NO CONSTRUCTION, FILLING, CUTTING, OR GRADE CHANGE IN EASEMENT WITHOUT PRIOR APPROVAL. 3. GRASS /EROSION CONTROL REQUIRED BEFORE FINAL. 12._310 q14 - SFk. AUG 3 0 2012 I 1�- -310 REScheck Software Version 4.4.3 Compliance Certificate Project Title. 416 Brewer Street Energy Code: 2003 IECC Location: Grapevine, Texas Construction Type: Single Family Glazing Area Percentage: 7% Heating Degree Days: 2683 Construction Site: Lot 11, Block A North Side Addition Grapevine, TX 76051 Owner /Agent: Designer /Contractor: Compliance: 17.6% Better Than Code Maximum UA: 632 Your UA: 521 Maximum SHGC: 0.40 Your SHGC: 0.40 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules. Ceiling 1: Flat Ceiling or Scissor Truss 1085 30.0 0.0 38 AC Decking: Cathedral Ceiling (no attic) 300 22.0 0.0 14 Slope Ceiling: Cathedral Ceiling (no attic) 300 22.0 0.0 14 Wall 1: Wood Frame, 16" o.c. 2327 13.0 OA 173 11 Windows: Metal Frame:Double Pane with Low -E 156 0.520 81 SHGC: 0.40 2 Doors: Solid 38 0.350 13 1 Door: Glass 18 0.450 8 SHGC: 0.40 No Slab Insulation: Slab -On- Grade: Unheated 173 0.0 180 Insulation depth: 0.0' Heat Pump 1: Air Source 7.8 HSPF, 14 SEER Compliance Statement: The proposed building design described here is consistent wi a building plans, specifications, r calculations submitted with the permit application. The proposed building has been signed to meet the 2003 IECC r rem, REScheck Version 4.4.3 and to comply with the mandatory requirements listed in t e REScheck Inspection C S.. G. Goodrich 8/21/12 Name - Title Signature Date Project Notes: Lone Star Professional Services 4917 Orchid Drive Fort Worth, Texas 76137 817 -881 -8085 Project Title: 416 Brewer Street Report date: 08/21/12 Data filename: C:\ Users\ Administrator\ Documents\ REScheck\ 416 Brewer.rck Page 1 other nts in CNJ( REScheck Software Version 4.4.3 Inspection Checklist Energy Code: 2003 IECC Location: Grapevine, Texas Construction Type: Single Family Glazing Area Percentage: 7% Heating Degree Days: 2683 Ceilings: • Ceiling 1: Flat Ceiling or Scissor Truss, R -30.0 cavity insulation Comments: • AC Decking: Cathedral Ceiling (no attic), R -22.0 cavity insulation Comments: • Slope Ceiling: Cathedral Ceiling (no attic), R -22.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R -13.0 cavity insulation Comments: Windows: ❑ 11 Windows: Metal Frame:Double Pane with Low -E, U- factor: 0.520, SHGC: 0.40, For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ 2 Doors: Solid, U- factor: 0.350 Comments: ❑ 1 Door: Glass, U- factor: 0.450, SHGC: 0.40, Comments: Floors: ❑ No Slab Insulation: Slab -On- Grade: Unheated, R -0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Heat Pump 1: Air Source: 7.8 HSPF, 14 SEER or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ Solar Heat Gain Coefficient (SHGC) values are determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R -13. Vapor Retarder: ❑ Installed on the warm -in- winter side of all non - vented framed ceilings, walls, and floors. Materials Identification and Installation: Project Title: 416 Brewer Street Report date: 08/21/12 Data filename: C:\ Users\ Administrator\ Documents\ REScheck\ 416 Brewer.rck Page 2 Cooling Systems Chilled Water, Refrigerant and 40 -55 0.5 0.5 0.75 Brine Below 40 1.0 1.0 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: 416 Brewer Street Report date: 08/21/12 Data filename: C:\ Users\ Administrator\ Documents\ REScheck\ 416 Brewer.rck Page 4 CITY OF GRAPEVINE TEMPORARY ELECTRIC RELEASE Temporary electricity has been requested for the purpose of construction, remodeling, addition or improvement to the following described property. It is understood that this release in no way authorizes occupancy of the building. It is further understood that this temporary release is for a thirty (30) day maximum time period and the undersigned releases all claims that may occur through accidents or spoilage of any type resulting from said electric power being turned off at the end of the thirty (30) day maximum time period. ADDRESS LOCATION OF TEMPORARY ELECTRIC RELEASE: ADDRESS: 41 � PERMIT NUMBER:` -�� CONTRACTOR INFORMATION NAME OF APPLICANT: orNt L L C jam. ADDRESS OF APPLICANT: 13,6 l madam.. r je r CITY, STATE, ZIP: TELEPHONE NUMBER: INSPECTIONS FOR TEMPORARY POWER MUST BE REQUESTED AT (817) 410 -3010 Nzz, AVe.0-1 NIF, i,, PRINT NAME: DATt: 1 BUI FICIAL SIGNATURE: 10/10/00 Revised: 4/10/02 CITY OF GRAPEVINE TEMPORARY GAS RELEASE Temporary gas has been requested for the purpose of construction, remodeling, addition or improvement to the following described property. It is understood that this release in no way authorizes occupancy of the building. It is further understood that this temporary release is for a thirty (30) day maximum time period and the undersigned releases all claims that may occur through accidents or spoilage of any type resulting from said gas power being turned off at the end of the thirty (30) day maximum time period. ADDRESS LOCATION OF TEMPORARY GAS RELEASE: ADDRESS: r 5`Ff . PERMIT NUMBER: 2 L- j F R 1-)- 7 CONTRACTOR INFORMATION NAME OF APPLICANT: Y'G pct s LL-C. (J,4C,4rt,,� ADDRESS OF APPLICANT: l 3o CITY, STATE, ZIP: 'L- TELEPHONE NUMBER: SI BUI INSPECTIONS FOR TEMPORARY GAS MUST BE REQUESTED AT (817) 410 -3010 AVt"rL1 RE: PRINT NAME: I DATE: NG\OFFICIAL SIGNATURE: 10/12/00 Revised: 4/10/02 DAT 'ne termite pyre- treatment service performed at the residential address above meet or exceeds the requirements fair protection "nest termites set forth in Section 8320.1 and R320.2 of the 2009 International Residential Code my co "'O ss an °SAN QME # AM PEST DMNSL IK May, 11. 2016 BY: 3/21/13 F;DX ENERGY SPECIALIUS MAR � pP�l rod. corNelectra _print/printform.cfm? type= final&idForrtF19326&idProject =31525 Email: www.foxenerpysl2ecialists.com Phone: 866 -448 -0961 — Fax 817 -546 -0161 FINAL INSPECTION SHEET Builder: Avery Homes Date: 03/21/13 Time: 12:44 PM Inspection 416 Brewer Street Subdivision: No Subdivision Address: Grapevine, Texas Model / Plan #: Story: 2 Batch I.D. #: Inspector: Hugo Vieyra Certification #: HERS: 7958659 IECC: 8168054 FINAL TEST INSPECTION INSPECTION CHECKLIST: 1) A/C Units (Condenser): Brand: Trane • Model# 4ttb4049e1000ca Model# Model# Model# • Serial # 12401txg2f Serial # Serial # Serial # • SEER 14 SEER SEER SEER 2) ES ID / Meter # 101076543. LG Electric Provider: Oncor Electric Delivery 3) Water Heater: Brand: Rheem Gallons: 50 # of units: 1 Heat Traps Electric Model #: 22v50f1 Serial #: X Gas Instantaneous 4) A/C Coil X Gas Electric • Model #: 4txcc049bc3hcba Model # Model # Model # • Serial # 12346y595g Serial # Serial # Serial # 5) Attic Insulation: 14.2 inches X Blown Foam Batt None R- value: 38 Level Grade: 1 6) Duct Blaster Test: TARGET: 127 CFM 25 0 CFM 25 0 CFM 25 0 CFM 25 205 CFM25 7) Blower Door Test: TARGET: 1715 CFM50 1703 CFM 50 X CO Detector(s) Installed When Required 7.4% Total Duct Leakage to the Outside Room to Room Pressure Testing +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location +/- pa Room to Room Pressure Testing Location RESULTS: Please check the appropriate boxfor the Testing X This Home is in compliance with the requirements of the: Inspection conducted on the date ONLY. 2006 IECC EFL GBT 1)BLOWERDOOR XPASS FAIL CANCELLED 2003 IECC X2009 IECC Energy Star 2) DUCT BLASTER XPASS FAIL CANCELLED X Testing WAS conducted. 3) ROOM TO ROOM PASS FAIL X CANCEId.ID X Blower Door Test X Duct Blaster Test 4) GREEN BUILT PASS FAIL X CANCELLED TestingNOT conducted. 5) FINAL XPASS FAIL CANCELLED Blower Door Test Duct Blaster Test The Nelrod Company C 2005 -2012 Fort Worth, TX 76109 apps.nel rod.conUelectra _pri nt/pri ntform.cfm?type = final &idForrr-- 19326&idProject =31525 1/1 Y CITY OF GRAPEVINE PWS i® 22000'I3 WATER CUSTOMER SERVICE INSPECTION CERTIFICATION DATE: (� ✓ BUILDING D j f - %i�� 60A SWIMMING POOL ADDRESS: 0 t `r I"1�IRRIGATION PERMIT #: �� `� �" PLUMBING / I hereby certify that I have inspected the water supply system at the above referenced address. To the best of my knowledge, the materials and methods used in the installation of this system comply with the plumbing code adopted by the City of Grapevine. Plumbing code is located in Chapter 7, Article VIII, (Ordinance number 92 -17), and Chapter 7, Article V, (Ordinance number 01 -93). In addition, to st of my knowledge, no cross connection exists at this address at the time of inspection. STOR LICE N MBE TITLE U INSPECTOR DATE OAforms \waterservinsp, 0501 08/03