Loading...
HomeMy WebLinkAboutORD 2000-079 ORDINANCE NO. 2000-79 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS AMENDING THE GRAPEVINE CODE OF ORDINANCES BY AMENDING CHAPTER 7 BUILDINGS AND CONSTRUCTION, ARTICLE I, SECTION 7-3, RELATIVE TO SECTION 403.2.2. OF THE 1994 UNIFORM BUILDING CODE, PROVIDING AMENDMENTS TO SAME, REPEALING CONFLICTING ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A PENALTY, NOT TO EXCEED TWO THOUSAND DOLLARS ($2,000.00) FOR EACH SEPARATE OFFENSE AND A SEPARATE OFFENSE SHALL BE DEEMED COMMITTED UPON EACH DAY DURING OR ON WHICH A VIOLATION OCCURS; DECLARING AN EMERGENCY AND PROVIDING AN EFFECTIVE DATE BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS: Section 1 That Chapter 7, Article I, Section 7-3 Uniform Building Code Amendments, Section 403.2.2 is hereby amended in its entirety to read as follows: "403.2.2 Modifications. The following modifications of code requirements are permitted: 1. In buildings of Type I construction the fire-resistive time periods set forth in Table 6-A may be reduced by one hour for interior bearing walls, exterior bearing and nonbearing walls, roofs and the beams supporting roofs, provided they do not frame into columns. In buildings of Type II-F.R. construction the fire-resistive time period set forth in Table 6-A may be reduced by one hour for interior bearing walls, exterior bearing and nonbearing walls, but no reduction is allowed for roofs. The fire-resistive time period reduction as specified herein shall not apply to exterior bearing and nonbearing walls whose fire-resistive rating is less than four hours. Vertical shafts other than stairway enclosures and elevator shafts may be reduced to one hour when sprinklers are installed within the shafts at alternate floors. 2. Except for corridors in Group B offices and Group R, Division 1 Occupancies and partitions separating dwelling units or guest rooms, all interior nonbearing partitions required to be one-hour fire-resistive construction by Table 6-A may be of noncombustible construction without a fire-resistive time period. 3. Fire dampers, other than those needed to protect floor-ceiling assemblies to maintain the fire resistance of the assembly, are not required. 4. Emergency windows required by Section 310.4 are not required." Section 2. That all ordinances or any parts thereof in conflict with the terms of this ordinance shall be and hereby are deemed repealed and of no force or effect. Section 3. Any person violating any of the provisions of this ordinance shall be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to exceed two thousand dollars ($2,000.00) and a separate offense shall be deemed committed upon each day during or on which a violation occurs or continues. Section 4. If any section, subsection, sentence, clause or phase of this ordinance shall for any reason be held to be invalid, such decision shall not affect the validity of the remaining portions of this ordinance. Section 5. The fact that the present ordinances and regulations of the City of Grapevine, Texas are inadequate to properly safeguard the health, safety, morals, peace and general welfare of the inhabitants of the City of Grapevine, Texas, creates an emergency for the immediate preservation of the public business, property, health, safety and general welfare of the public which requires that this ordinance shall become effective from and after the date of its passage, and it is accordingly so ordained. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS, on this the 15th day of August, 2000. APPROVED: William D. Tate Mayor ATTEST: -ti-di.z., • i Lind Huff City Secretary 2 ORD. NO. 2000-79 APPROVED AS TO FORM: John F. Boyle, Jr. City Attorney ORD. NO. 2000-79 3