HomeMy WebLinkAbout06/24/2022 - F211334-1054852,1054853Mortar Cubes Compression
Test Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:ELEVATOR SHAFT WALLS
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1054852
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/27/2022
Time Placed:8:15 AM
N/A
N/A
79
75
Date Received:N/A
Concrete Supplier:SITE MIX
Submitted By:Thompson, Bryan
Plant Number:N/A
Delivery Ticket No.:N/A
N/A
Batch Time:8:10:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CUBE COMPRESSION TEST RESULTS
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:N/A
Mix ID:TYPE S MORTAR
Break
Type:
Sample Location:COURSES 25-32 ( DOORWAYS AND ABOVE)
PM:PAUL DELANEY
Date Issued:06/24/2022
Specified Strength:1800
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
95 6/3/2022 7 56104.00 1400LABN/A 2.00 2.00 N/A
96 6/3/2022 7 57904.00 1450LABN/A 2.00 2.00 N/A
97 6/3/2022 7 48604.00 1220LABN/A 2.00 2.00 N/A
98 6/24/2022 28 71404.00 1780LABN/A 2.00 2.00 N/A
103 6/24/2022 28 72004.00 1800LABC-1231 2.00 2.00 N/A
104 6/24/2022 28 61704.00 1540LABC-1231 2.00 2.00 N/A
CC:
1710
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 487029
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 2
Grout Prism Compression
Test Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:ELEVATOR SHAFT WALLS
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1054853
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/27/2022
Time Placed:7:45 AM
9.00
N/A
75
73
Date Received:N/A
Concrete Supplier:N/A
Submitted By:Thompson, Bryan
Plant Number:N/A
Delivery Ticket No.:N/A
N/A
Batch Time:7:40:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
PRISM COMPRESSION TEST RESULTS
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:
Mix ID:SITE MIX
Break
Type:
Sample Location:COURSES 25-32 ( DOORWAYS AND ABOVE)
PM:PAUL DELANEY
Date Issued:06/24/2022
Specified Strength:3000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
99 6/3/2022 7 3067012.77 2400LABC-617 7.99 3.49 3.66
100 6/3/2022 7 3622012.84 2820LABC-617 7.10 3.48 3.69
101 6/24/2022 28 5842013.25 4410LABC-617 7.76 3.66 3.62
102 6/24/2022 28 5520013.25 4170LABC-617 7.81 3.61 3.67
CC:
4290
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 487034
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 2 of 2