Loading...
HomeMy WebLinkAbout07/20/2022 - F211334-1066209,1066209,1066209,1066209,1066209 - Paving N End Pk LotConcrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: NORTH END OF PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1066209-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/21/2022 Time Placed:1:10 AM 2.25 3.0 82 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Thompson, Bryan Plant Number:501 Delivery Ticket No.:50921467 144 Batch Time:12:11:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:5'N & 3'E OF NW CORNER EXT. S. PAVING AREA PM:PAUL DELANEY Date Issued:07/20/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 160 6/28/2022 7 4847012.56 3860LABC-1231 8.00 N/A 4.002 161 7/19/2022 28 5938012.56 4730LABC-1231 8.00 N/A 4.001 162 7/19/2022 28 5895012.56 4690LABC-1231 8.00 N/A 4.002 163 7/19/2022 28 5922012.56 4710LABC-1231 8.00 N/A 4.001 164 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 4710 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489697 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 5 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: NORTH END OF PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1066209-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/21/2022 Time Placed:2:35 AM 3.00 3.0 82 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Thompson, Bryan Plant Number:501 Delivery Ticket No.:50921486 144.8 Batch Time:1:36:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:55'N & 20'E OF NW CORNER EXT. S. PAVING AREA PM:PAUL DELANEY Date Issued:07/20/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 165 6/28/2022 7 4153012.56 3310LABC-1231 8.00 N/A 4.003 166 7/19/2022 28 5198012.56 4140LABC-1231 8.00 N/A 4.003 167 7/19/2022 28 4972012.56 3960LABC-1231 8.00 N/A 4.002 168 7/19/2022 28 4900012.56 3900LABC-1231 8.00 N/A 4.002 169 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 4000 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489698 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 5 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: NORTH END OF PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1066209-S3 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/21/2022 Time Placed:4:15 AM 3.25 2.8 81 85 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Thompson, Bryan Plant Number:501 Delivery Ticket No.:50921511 144 Batch Time:3:05:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:40'N & 75'E OF NW CORNER EXT. S. PAVING AREA PM:PAUL DELANEY Date Issued:07/20/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 170 6/28/2022 7 3301012.56 2630LABC-1231 8.00 N/A 4.003 171 7/19/2022 28 4492012.56 3580LABC-1231 8.00 N/A 4.003 172 7/19/2022 28 4589012.56 3650LABC-1231 8.00 N/A 4.001 173 7/19/2022 28 4298012.56 3420LABC-1231 8.00 N/A 4.002 174 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 3550 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489699 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 3 of 5 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: NE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1066209-S4 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/21/2022 Time Placed:6:30 AM 85 4.75 2.5 85 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Thompson, Bryan Plant Number:501 Delivery Ticket No.:50921592 144.8 Batch Time:5:35:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:10'N & 20'E OF NW CORNER EXT. S. PAVING AREA PM:PAUL DELANEY Date Issued:07/20/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 175 6/28/2022 7 3474012.56 2770LABC-1231 8.00 N/A 4.002 176 7/19/2022 28 4620012.56 3680LABC-1231 8.00 N/A 4.003 177 7/19/2022 28 4739012.56 3770LABC-1231 8.00 N/A 4.002 178 7/19/2022 28 4570012.56 3640LABC-1231 8.00 N/A 4.001 179 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 3700 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489700 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 4 of 5 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: NE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1066209-S5 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/21/2022 Time Placed:8:30 AM 3.50 3.0 79 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Thompson, Bryan Plant Number:501 Delivery Ticket No.:50921716 144.8 Batch Time:7:30:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:120'N & 15'E OF EXISTING CONCRETE PM:PAUL DELANEY Date Issued:07/20/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 180 6/28/2022 7 3441012.56 2740LABC-1231 8.00 N/A 4.002 181 7/19/2022 28 4766012.56 3790LABC-1231 8.00 N/A 4.003 182 7/19/2022 28 4534012.56 3610LABC-1231 8.00 N/A 4.002 183 7/19/2022 28 4504012.56 3590LABC-1231 8.00 N/A 4.003 184 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 3660 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489701 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 5 of 5