HomeMy WebLinkAboutItem 08 - CU22-30 H3 Headquarters-L-fem #7
North
SITE
E. DAl1AS ROAD
r: �... �•s --
Ar
�-r
� �7•d r�. ���
VICINITY MAP
Nor To SCAIF
7[ �D 1WMD
JUL 15 2022
By:... .....................
SITE PLAN NOTES:
1. REFUSE DISPOSAL AREAS SHALL BE LANDSCAPED AND SCREENED FROM VIEW.
2. MECHANICAL AND ELECTRICAL EQUIPMENT INCLUDING AIR CONDITIONING UNITS, SHALL BE DESIGNED, INSTALLED
AND OPERATED TO MINIMIZE NOISE IMPACT ON SURROUNDING PROPERTY ALL SUCH EQUIPMENT SHALL BE
SCREENED FROM PUBLIC VIEW.
J. THE MASONRY REQUIREMENTS OF SECTION 54 SHALL BE MET
4. ILLUMINATED SIGNAGE WAS INCLUDING THE DETERMINA 77ON OF TH£ ILLUMINATION LEVELS
5. PROPOSED GROUND SIGNAGE MEETS MINIMUM REQUIREMENTS OF SEC77ON 60 OF THE ZONING ORDINANCE AND
WILL BE APPROVED THROUGH SEPARATE BUILDING PERMIT.
6. ALL ONSITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSIRUC77ON SHALL BE LOCATED UNDERGROUND.
7 ALL REQUIREMENTS OF THE CITY OF GRAPEVINE SOIL EROSION CONTROL ORDINANCE SHALL BE MET DURING THE
PERIOD OF CONSTRUCTION.
-o
�5�
LOT 1. BLOCK 1TIO
MILLER COMPANY ADDIN
CABINET A, SUDE 12703
INST/ D208188055
ZONINGP.R.T.C.T.
ZONINGI U
R-7.5 I i -
L PR OSED 6' WOODEN SCREENING FENCE
- - i L - --- -- --
N 7025449.18
E 2409486. woE BR"«� `"° °�"EF " of �o S 89•.1X177 •o PLA -2 150 R
ifr- --__-R-____ __ - Lau __ _--
15' CPP
ZONING
R-7.5
0�
,a eoe-
PROPOSED -
6' WOODEN
SCREENING FENCE
ZONING
R-7.5
15' CIO
15' SIDE YARD -
SETBACK
PROPOSED
6' WOODEN
SCREENING FENCE
25' BUFFER
ZONING YARD
R-7.5
18' CAP
N 7025279.72
E 2409481.56
EXISTING CONCRETE SIDEWALK
t
11
X TING ONE OR
DING-
7
5,057 SF -�
tF 614.72 15'-8" HEIGHT
LOADING AREA
LOT 1. BLOCK 1
N ESTHER MOORE
Ot ADDITION
` VOLUME 3�8-186;
PAGE 58'
D.R.T.C.T.
I� IvI I I 9
I
I
PROPOSED CONCRETE
PARKING
�I
i
7
JO' REAR YARD F.PROPOSED CONG�E7E
SETBACK PARKING
GATE
OPOSED
0 MPS R WiW
EENIN WALLS
ZONING �1 °
Ll
fso~-
PROPOSED
OFFICE
3,640 SF
UPPER LEVEL
MEZZANINE
1,820 SF
FF 615.10
35'-6" HEIGHT
0838 ACRE
36.05 SO. FT
70- _ _ _ _ _ - -
N 25448.51
E 409701.82
"/"-"F-
EXISTING
4' WOODEN FENCE
w
41 2 EXISTING CONCRETE DRIVEWAY
S 89'58 32 W 216.02 r Rae °mna°R ,ex aAT wLlae Tw-"e, woe x B.IK-
---Es-0n-------- -----
E%-6" W
EX-6"w
f N WATER ME
EXlS71 SSMH EXISTING CONCRETE
95' TO DRIVEWAY 99.2' TO ADJACENT DRIVEWAY
EAST DALLAS ROAD
(VARIABLE WIDTH PUBLIC RIGHT OF WAY)
EXIS77NG FIRE
/I
I
PROPOSED
6' WOODEN
I
I
SCREENING FENCE
oI
�I
od Q
ouiuN+.�,.vam
£
3 wl
ZONING
e „I
U
!"T
LOT 1. BLOCK 1
10 '
MACORNER ADDITION
p
CABINET A, AIDE 2238
INST/ D.05
w
3
�I
P.R. T.C. T. T.C. T.
15' SIDE YARD
SETBACK
EXISTING
FUEL CANOPY
STRUCTURE
L_zON
ADJACENT LOT
30' I
I
i
I
I
N 7025279.81
v
�!
4.
E 2409697.57
-____-___--_
CONDITIONAL USE REQUEST CU22-30 IS A REQUEST TO AMEND THE PREVIOUSLY APPROVED SITE PLAN TO SPECIFICALLY ALLOW OUTDOOR
STORAGE IN CON,AINCTION PATH THE DEVELOPMENT OF A NEW TWO-STORY CONSTRUCTION OF A BUILDING TRADES CONTRACTOR
u
NO7E•ALL ON -SITE ELECTRICAL
CONDUCTORS ASSOCIATED WITH
NEW CONSTRUCTION SHALL BE
LOCATED UNDERGROUND.
CASE NUMBER: CU22-30
LOCATION:
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
WARN/NG TO CONTRACTOR
CALL TEXAS 811 (LOCATING SERVICE) OR OTHER UTILITY
LOCATING SERVICES 48 HOURS PRIOR TO CONSTRUCTION
AC770TY. EXISTING UTILITY DATA /S PROVIDED FOR
INFORMA7ION ONLY. ALTHOUGH THIS DATA /S SHOWN AS
ACCURATELY AS POSSIBLE, THE CONTRACTOR IS
CAU77ONED THAT DUNAWAY ASSOCIATES L.P. DOES NOT
ASSUME OR IMPLY ANY RESPONSIBILITY FOR 774E
ACCURACY OF THIS DATA.
U77LITY NOTE.
THE UTILITIES SHOWN ON THE PLANS WERE COMP/LED
FROM VARIOUS SOURCES AND ARE INTENDED TO SHOW THE
GENERAL EXISTENCE AND LOCATION OF U77LI77ES IN THE
AREA OF CONSTRUCTION. THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR THE ACCURACY OF THE U77LITY
INFORMATION SHOWN ON THE PLANS THE CONTRACTOR
=
SHALL VERIFY THE EXACT LOCAT70N OF ALL U77LI77ES
s
PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
CONTACT U77LITY COMPANIES 48 HOURS IN ADVANCE OF
ANY CONS7RUCI0N ACT/VIT/ES IN ORDER TO DETERMINE IF
i
THERE /S ANY CONFLICT WITH THE PROPOSED FACILITIES
4
THE CONTRACTOR SHALL NOTIFY THE ENGINEER
W
IMMEDIATELY WHEN CONFLICTS WIN EXIS77NC U77LI71E5 ARE
DISCOVERED. THE FOLLOWING PHONE NUMBERS ARE
PROVIDED FOR CONVENIENCE CONSIDERAT70N OF OTHER
UTILITIES MAY BE REWIRED.
TEXAS 811 (LOCATING SERVICE) 811
SPECTRUM COMMUNICATIONS (TV CABLE) (888) 438-2427
AT&T (817) 3J8-6202
VER/ZON (800) 483-1000
A TMOS ENERGY (800) 817-8090
ONCOR ELECTRIC DELIVERY (888) JIJ-6862
SITE LEGEND
PROPERTY BOUNDARY
- - - ADJOINERS
- OUIL.HG SETBACK
- YARD SETBACK
- - - - - - EASEMENT
- FIRE LANE
PROPOSED CURB
O PROPOSEDWHEELSTOP
s
�^
PROPOSED RETAINING WAtI
.3$Dj
PAVEDAREA
QPARKING COUNT
-
O E%ISTNG POWEfl POLE
EXISNNG SIGN
--v-O PROPOSED FENCE
EXISTING FENCE
y EXISTING FIRE HYDRANT
m EXISTING WATER VALVE
® EXISTING SSWR MANHOLE
El EXISTNG STORM INLET
a
DATE:
SHEET: 4 OR 22
APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFECT
WITH ANY CODES OR ORDINANCES.
PLANNING SERVICES DEPARTMENT
SITE PLAN
for
H3 HEADQUARTERS
LOT 1, BLOCK 1, ESTHER MOORE ADDITION
City of Graps Ane, Tarrant County, Texas
0.83, axes
zeNe: U
Data of Preparation: June 6th, 2022
LUJ
leass
LLJ X
0
CC P K
Cz g
<>
wa �
= Q w
OF \\\
OF TF IN
NIOi0lA5 J. POWLTL �
R1 AL
OB NO.
8310.002
DRAwN ar:
RWB
DESIGNED BY: RWB
CHECKED BY:
NIP
DATE:
07-08-2022
SHEET.
C3.0