HomeMy WebLinkAbout07/29/2022 - F211334-1078948 - SIDEWALKConcrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:SIDEWALK
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1078948
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:7/21/2022
Time Placed:10:38 AM
2.50
4.0
87
96
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Russell, Nicholas
Plant Number:508
Delivery Ticket No.:50930713
N/A
Batch Time:9:50:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:35U500BG
Break
Type:
Sample Location:45'N, 10'W OF N CORNER OF N ENTRANCE OF MERLOT AVE
PM:PAUL DELANEY
Date Issued:07/29/2022
Specified Strength:3500
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
240 7/28/2022 7 4121012.56 3280LABC-1231 8.00 N/A 4.00
241 8/18/2022 28 012.56LABC-1231 8.00 N/A 4.001
242 8/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
243 8/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
244 9/15/2022 56 012.56LABC-1231 8.00 N/A 4.00
Notes:INFORMED ONSITE FOREMAN OF HIGH CONCRETE TEMPERATURE
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 493750
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 1