HomeMy WebLinkAboutItem 04 - CU11-28 Baylor Grapevinefiz -)� Z TO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE PLANNING AND ZONING COMMISSION FROM: BRUNO RUMBELOW, CITY MANAGER . SCOTT WILLIAMS, DEVELOPMENT SERVICES DIRECTOR MEETING DATE: OCTOBER 18, 2011 SUBJECT: DEVELOPMENT SERVICES TECHNICAL REPORT OF CONDITIONAL USE APPLICATION CU11 -28 BAYLOR GRAPEVINE r - --1 I I � i 1 __ (i ry__ Grapevine ro APPLICANT: T. Douglas Lawson — Baylor Grapevine + Lake I dove I _ Ra PROPERTY LOCATION AND SIZE: I 1 -H. 1115 rt Sorthwec I The subject property is located at 1650 West College 5�' m Street, Lot 1A, Block A, Grapevine Medical Center Addition. The site contains 26.27 acres. S DFW Hall- Johnson ,7 Airport a I �p I L_, m I LA I m Glade Rd. O REQUESTED CONDITIONAL USE AND COMMENTS: The applicant is requesting a conditional use permit to amend the previously approved site Ian of CU07 -15 Ord. 07 -40 specifically to allow a four -sto 167,939 square-foot expansion to the front of the hospital. Baylor Regional Medical Center of Grapevine expansion plans include a new tower and main entry both on the south side of the hospital, and a bridge connector from the west side of the hospital to the existing parking garage. With this request the applicant proposes to add a new four -story tower, 85' above ground level which upon completion will add up to 109 additional patient beds, allow for enlarged cardio vascular services and expanded radiology services. A possible fifth floor, up to 100' above ground level may be added to the tower in a future phase. At the conclusion of the expansion, 1,875 parking spaces will be available including 1,029 patient/visitor parking spaces. Required parking 0:2CL1=11 -28.4 1 October 12, 2011 (3:14PM) for the existing uses on the subject site, including the proposed hospital expansion is 1,240- spaces. PRESENT ZONING AND USE: Current zoning on the property is "PCD ", Planned Commerce Development and "CC" Community Commercial and is currently developed with a hospital, medical office tower helistop, and central utility plant. HISTORY OF TRACT AND SURROUNDING AREA: The subject property was rezoned in 1982 (Z82 -34) from "PD ", Planned Development District allowing for multifamily dwellings, community business, light industrial, off - street parking, a greenbelt recreational area to "SP" Specific Use Permit District for the construction and operation of a multiple story professional building, construction and operation of a multiple story patient bed tower and the expansion and operation of a power plant all incidental to the operation of a medical center complex, providing the height does not exceed the maximum height permitted by the Dallas/Fort Worth Regional Airport Zoning Ordinance, 756 feet or seven floors; whichever height is lesser of the permitted heights all in accordance with a site plan. The "SP" Specific Use Permit District was amended in 1989 with the location of a future physical plant and future helistop site and future 4 -story expansion to patient tower (CU89 -07) and a location of a helistop pad (SU89- 02). The Specific Use Permit District containing 15.288 acres was expanded to add 10.9866 for a total of 26.2746 acres (CU92 -06) in 1992 to add a new physical plant and expand the parking area. The District was amended by CU94 -30 in 1994 to develop a one - story 12,830 square foot family clinic. CU95 -04 amended the site plan to expand the development for the outpatient facility emergency room, diagnostic radiology and medical imaging, women's service center and intensive care. SU96 -11 allowed for six wireless communications antennas and associated equipment to be placed atop the Professional Building. CU96 -32 amended the site plan to expand the Women's Center. SU96 -15 allowed for three wireless communications antenna arrays of three panels each (nine total panels) and associated equipment panels to be placed inside the elevator equipment penthouse. SU97 -05 was approved on March 18, 1997 for three wireless communications antenna arrays of three panels each (nine total panels) to be placed on the sides of the Professional Building with an equipment shelter to be placed on the roof. CU97 -11 amended the site plan to allow a 300 square foot addition to the Dietary Center, modifications to the patient drop -off drive and canopy, and an addition of a 115- vehicle parking lot. Conditional Use Permit CU98 -37 (Ord. 99 -05) allowed the expansion of the existing hospital facility, the addition of a 436 vehicle parking garage, an additional dock drive, and two (2) temporary surface parking lots (not to exceed 18 months from date of approval). Conditional use request C000 -23 amended the site plan specifically to convert the approved 54 temporary parking spaces on the northwest side of the property to permanent parking for the Baylor Hospital. At the November 21, 2000 meeting Council approved conditional use request CU00 -55 (Ord. 00 -121) specifically to amended the site plan to allow the conversion of a previously approved four -story addition to a five -story 0 Z=CU11 -28.4 2 October 12, 2011 (3:14PM) addition and the conversion of a previously approved one -story addition to a two -story addition. At the June 19, 2001 meeting Council approved conditional use request CU01 -26 (Ord. 01 -48) specifically to amend the site plan to add a sixth floor to previously approved five floor administration /patient facility and locate a new generator on the lower level of the existing parking garage. Conditional use request CU05 -55 amended the site plan specifically to allow for a 1.90 acre, 145 space parking lot for the existing hospital facility. Conditional use request CU06 -09 amended the site plan specifically for an expansion in excess of 6,000 square feet to the emergency services area of the medical complex. Conditional use request CU06 -30 amended the site plan specifically to add shade structures to cover a designated handicap parking area adjacent to the south side of the existing parking garage. At the July, 2007 meeting Council approved conditional use request CU07 -15 (Ord. 07 -40) on the subject site which allowed for a two story addition to the south tower and the development of a central utility plant. At the May 20, 2008 meeting Council approved conditional use request CU08 -11 (Ord. 08 -26) and special use request SU08 -02 (Ord.08 -27) respectively, on the subject site which allowed for a five story parking garage and a helistop. The Site Plan Review Committee at their October 28, 2009 meeting approved conditional request CU09 -39 to allow for revised drive aisles and surface parking. The "R- 12.5 ", Single Family, "R -3.5 ", Duplex, and" PO ", Professional Office areas to the north were rezoned from "R -1 ", Single Family, "R -2 ", Two Family, "R -3", Multifamily and "C- 2", Community Business in the 1984 City Rezoning. The "CC ", Community Commercial area to the south was rezoned from "PCD ", Planned Commerce Development in 1987 (Z87 -09) and from "PD ", Planned Development in the 1984 City Rezoning. The Planned Commerce Development area to the south was rezoned from "C -2 ", Community Business and "CC ", Community Commercial in the 1984 City rezoning. The "PO ", Professional Office area to the east was rezoned from "PCD ", Planned Commerce Development in 1987 (Z87 -09) and from "PD ", Planned Development in the 1984 City Rezoning. The "LI ", Light Industrial area to the west was rezoned from 1- 1 ", Light Industrial in the 1984 City Rezoning. SURROUNDING ZONING AND EXISTING LAND USE: NORTH: "R- 12.5 ", Single Family, "R -3.5 ", Duplex and "PO ", Professional Office - Ridgecrest Addition SOUTH: "CC ", Community Commercial — LabCorp , and two Doctor Office Buildings EAST: "PO ", Professional Office - Doctor's Office Building WEST: "LI ", Light Industrial - State Highway 114 West and Grapevine Industrial Park OAZCUICU11 -28.4 3 October 12, 2011 (3:14PM) AIRPORT IMPACT: The subject tract is located within "Zone A" Minimal Zone of Effect as defined on the "Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map. Few activities will be affected by aircraft sounds in Zone A, except for sound sensitive activities such as auditoriums, churches, schools, hospitals, and theaters. The proposed additions are appropriate in this noise zone. MASTER PLAN APPLICATION: The Master Plan designates the subject property as Commercial and a small area to the east as Low Intensity Commercial. The conditional use request complies with the Master Plan. THOROUGHFARE PLAN APPLICATION: The Thoroughfare Plan designates College Street as a Type E Collector, requiring a 75- foot right -of -way, which is developed with four lanes with an existing right -of -way of 70 feet. Lancaster Drive and Baylor Parkway are local non - residential streets and are not designated thoroughfares. /at OAZCU1CU11 -28.4 4 October 12, 2011 (3:14PM) 45 17 4 1s 5 ri 3 3a`X v�.' 16 5 r. 10 n 1z 1 16 4 {'.a'SR �+ 6 B R Nv' 4� 0 16.E W ,5 17 r tt 15 14 y 5 6 15 7A 15 15 7 R �4 y MZN CT A la 6 14 7 14 7 R -12.5 SR i( zz R -3: 5 13 5 13 ^^^�����yyyyyy [ 19 20R 7 13 6 13 12 8 9R g1 ` e ! 43Ui11''i'11[, g 12 g 12 9 l2 2R 23 11 0 It 10 111 1 59388 '.� 9 11 10 Il 10 f m 10 .3 W u - >i,s�� #Y�*.bleF i3 i, 2.56 AC ry 11881 j Arb r� s- } 1 GO ,'. - . \7TN l�li3 1 1882 12 - - - -- - -- - - - - - - - 1' &0 S .. :-- �- 1sS 1. Dip- - -:6fL. fir._.- ' � �� '1,u Y . .. .. LI r �- - - - - - DQ� - - - - - - - �...,-wP1�vM C QP 60 gS . �� 7 .,., - r,...... B .�. 8 262746 .. - - _. ........ 4 1p 3R 17 16 16 0,10. 'j 'R x s@ 10 pN N PN ! �'t ` -\ A 1 2.3414 10 Q CU 11 -28 Baylor Medical Center PART 1. APPLICANT INFORMATION Applicant Name: Applicant Address: City/State/Zip Phone No. Email Address I Applicant's interest in subject property PART 2. PROPERTY INFORMATION ----------- - ------------- - ..... .. ..... .. 20 0 Fax No. Phone Street Address of subject property 0 -------- --------- — ............... Legal Description: Lot Block Additionj GmPr341me Mr61UC-+Z- C0EAyrWA Legal description of subject property (metes & bounds must be described on 8 112" x 11" sheet 2 -5-F Size of subject property: acres square footage -Z F-- Present zoning classification F 7 Proposed use of properly [ A6CrPPrr*L. Zoning ordinance provision requiring a special use PART 3. PROPERTY OWNER INFORMATION Property Owner T V6VGL,.,A5 L-AU56sJ Prop Owner Address[ dgr City/State/Zip Co AA MW Ale Phone No. JP7 J� -Zq 'ZJ570 0 1 Fax No. )-7 ----------- ❑ Submit a letter describing the proposed special use and note the request on the site plan document • In the same letter, describe or show on the site plan, and special requirements or conditions imposed upon the particular special use by applicable district regulations (example: buffer yards, distance between users) ❑ in the same letter, describe whether the proposed special use will, or will not cause substantial harm to the value, use, or grobyment of other property in the neighborhood Also, describe how the proposed special use will add to the value, use in the neighborhood. ❑ Application of site plan approval (SecUon 47, see attached Form B'). ❑ .7he site plan submission shag meet the requirements of Section 47, Site Plan RequiremeRfs, M S E P 7 2011 El All special use and special use applications are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date. ❑ All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings maybe continued to the next public hearing. Public hearings will not be tabled. ❑ Any changes to a site plan (no matterhow minor or mafi4 approved with a special use or specialuse permit can only be approved by city council through Me public hearing process. ❑ t have read and understand all the requirements as set forth by the application for special use or special use permit and acknowledge that all requirements of this application have been met at the time of submittal, PART 4. SIGNATURE TO AUTHORIZE SPECIAL USE REQUEST A P CE Aanaa USE REQUEST SIGN ON THE SUBJECT PROPERTY T, Print Applicant's Name Applicant's Signature The State of XAS County of 'r A f ° Before me (notary) on this day personally appeared (applicant) known to me (or proved t me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office this Sf day o �� , A.D. oil- MARIE I a� CLOUD Notary Public, State of Texas k ' „= My Commission Expires t` ! November 19, 2013 A _ _ Notary In and For State of ' Print Property Owner's Name Property Owner's Signature The State of County of Before me (notary) ri >~ on this day personally appeared (applicant) ^ known to me (or proved ome on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office this f day of S- q0ttmbkr• , A.Q. Apt EE i MARIE CLOUD Notary In and For State of F71 ' ' Notary Public. State of Texas _ MY Commission Expires November 19, 2013 "__LA.�..,w, ACCK II'! EDfa.�i'ri 14` ' All Ccnditional Use and Special Use Applications are assumed to be complele when filed and will be placed on the agenda nr public hearing aif the discretion of the staff. Based on the size of the agenda, your application maybe scheduled to a later date. All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled Any changes to a site plan (no matter how minor or major) approved with a conditional use or a special use permit can only be approved by city council through the public hearing process. Any application for a change in zoning or for an amendment to the zoning ordinance shall have, from the date of submittal, a period of four months to request and be scheduled on an agenda before the Planning and Zoning Commission and City Council. if after said period of four months an application has not been scheduled before the Commission and Council said application shall be considered withdrawn, with forfeiture of all riling fees. The application, along with the required Filing fee may be resubmitted any time thereafter for reconsideration. Delays in scheduling applications before the Planning and Zoning Commission and City Council created by city staff shall not be considered a part of the four month period. I have read and understand all of the requirements as set forth by the application for conditional use orspecial use permit and acknowledge that all requirements of this application have been met at the time of submittal. Signature of Applicant Date Z r r Signature of Property Owner Date � ECEl�E October 5, 2011 Planning Department City of Grapevine 200 South Mairi Street . Grapevine; Texas 76051 RE: Baylor Regional Medical Center at Grapevine Conditional Application . New Tower . . To:.Whom It May Concern: Per the`conditional use application; 'in reference to the above mentioned project, 'we are.prgvidingthe following information: • BRMC'. @: Grapevine . 1650 N.;College Street " -Grapevine, Texas-76051 . Lot l a blk A Grapevine Medical Center Addition , • Construction of a four story addition to the fiont-of the existing hospital.to. , include new Radiology, NICU, Cardio Vascular services, new'patient rooms and'associated, services. • . he.additions §ubsiantially conform to the approved master plan. " If you have any questions,. please lee1 free to contact us: . inoerel yours; ORDINANCE NO. AN ORDINANCE ISSUING A CONDITIONAL USE PERMIT IN ACCORDANCE WITH SECTION 48 OF ORDINANCE NO. 82 -73, THE COMPREHENSIVE ZONING ORDINANCE OF.THE CITY OF GRAPEVINE, TEXAS, SAME BEING ALSO KNOWN AS APPENDIX "D" OF THE CITY CODE, BY GRANTING CONDITIONAL USE PERMIT CU11 -28 TO AMEND THE SITE PLAN APPROVED BY ORDINANCE NO. 2007 -40 FOR AN ADDITION TO THE FRONT OF THE HOSPITAL IN A DISTRICT ZONED "PCD" PLANNED COMMERCE DEVELOPMENT DISTRICT AND "CC" COMMUNITY COMMERCIAL DISTRICT REGULATIONS ALL IN ACCORDANCE WITH A SITE PLAN APPROVED PURSUANT TO SECTION 47 OF ORDINANCE NO. 82 -73 AND ALL OTHER CONDITIONS, RESTRICTIONS AND SAFEGUARDS IMPOSED HEREIN; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; PROVIDING'A CLAUSE RELATING TO SEVERABILITY; DETERMINING THAT THE PUBLIC INTERESTS, MORALS AND GENERAL WELFARE DEMAND THE ISSUANCE OF THIS CONDITIONAL USE PERMIT; PROVIDING A PENALTY NOT TO. EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) AND A SEPARATE OFFENSE SHALL BE DEEMED COMMITTED UPON EACH DAY DURING OR ON WHICH A VIOLATION OCCURS; DECLARING AN EMERGENCY AND PROVIDING AN EFFECTIVE DATE WHEREAS, an application was made requesting issuance of a conditional use permit by making,applications for same with the Planning & Zoning Commission of the City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites having been complied with, the case having come before the City Council of the City of Grapevine, Texas, after all 'legal notices requirements, conditions and prerequisites Laving been complied with; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the CityCouncil did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied: safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the site; safety from fire hazards and measures for fire control; protection of adjacent property from flood or water damages, noise producing elements, and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting, and types of signs and relation of signs to traffic control and adjacent property; street size and adequacy of width for traffic reasonably expected to be generated by, the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off - street parking facilities; location of ingress and egress points for parking and off - street locating spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health and the general welfare; effect on light and air; the effect on the overcrowding of the land; the effect on the concentration of population; the effect on the transportation, water, sewerage, schools, parks and other facilities; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council of the City of Grapevine, Texas, did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied; effect on the congestion of the streets, the fire hazards, panics and other dangers possibly present in the securing of safety from same, the effect on the promotion of health and the general welfare, effect on adequate light and air, the effect on the overcrowding of the land, the effect on the concentration of population, the effect on the transportation, water, sewerage, schools, parks and other public facilities; and WHEREAS, all of the requirements of Section 48 of Ordinance No. 82 -73 have been satisfied by the submission of evidence at a public hearing; and WHEREAS, the City Council further considered among otherthings,the characterof the existing zoning district and its peculiar suitability for particular uses and with the view to conserve the value of buildings and encourage the most appropriate use of land throughout this City; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is a public necessity for the granting of this conditional use permit, that the public demands it, that the public interest clearly requires the amendment, that the zoning changes do not unreasonably invade the rights of those who bought or improved propertywith reference to the classification which existed at the time their original investment was made; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that the conditional use permit lessens the congestion in the streets, helps secure safety from fire, panic and other dangers, prevents the overcrowding of land, avoids undue concentration of population, facilitates the adequate provisions of transportation, water, sewerage, schools, parks and other public requirements; and WHEREAS, the City Council of the City of Grapevine, Texas, has determined that there is a necessity and need for this conditional use permit and has also found and determined that there has been a change in the conditions of the property surrounding and in close proximity to the property requested for a change since this property was originally classified and, therefore, feels that the issuance of this conditional use permit for the particular piece of property is needed, is called for, and is in the best interest of the public at large, the citizens of the City of Grapevine, Texas, and helps promote the general health, safety and welfare of this community. ORD. NO. 2 NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS: Section 1;. That the City does hereby issue a conditional use permit in accordance with Section 48 of Ordinance No. 82 -73, the Comprehensive Zoning Ordinance of the City of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by granting Conditional Use Permit CU11 -28 to amend the site plan approved by Ordinance No. 2007 -40 (Baylor Medical Center at Grapevine) to allow a 32,000 square foot addition to the south tower and the development of a new central utility plant, specifically to allow a 167,939 square foot expansion to the front of the hospital in a district zoned "PCD" Planned Commerce Development District and "CC" Community Commercial District Regulations within the following described property: Lot 1A, Block A, Grapevine Medical Center Addition (1650 West College Street) all in accordance with a site plan approved pursuant to Section 47 of Ordinance No. 82 -73, attached hereto and made a part hereof as Exhibit "A ", and all other conditions, restrictions, and safeguards imposed herein, including but not limited to the following: None. Section 2.' That the City Manager is hereby directed to amend the official zoning map of the City of Grapevine, Texas, to reflect the herein conditional use permit. Section 3. That in all other respects the use of the tract or tracts of land herein above described' shall be subject to all the applicable regulations contained in said City of Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of Grapevine, Texas. Section 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting health, safety, morals and the general welfare of the community. They have been designed with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from fire, panic, flood and other dangers; provide adequate light and air; to prevent overcrowding of land, to avoid undue concentration of population; facilitate the adequate provisions of transportation, water, sewerage, drainage and surface water, parks and other public requirements, and to make adequate provisions for the normal business, commercial needs and development of the community. They have been made with reasonable consideration, among other things, of the character of the district, and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. Section 5.1 That this ordinance shall be cumulative of all other ordinances of the City of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said ordinances except in those instances where provisions of those ordinances which are in direct conflict with the provisions of this ordinance. Section 6. That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of ORD. NO. 3 land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of the tract or tracts of land described herein. Section 7. That any person violating any of the provisions of this ordinance shall be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed committed upon each day during or on which a violation occurs or continues. Section 8. That the fact that the present ordinances and regulations of the City of Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace and general welfare of the inhabitants of the City of Grapevine, Texas, creates an emergency for the immediate preservation of the public business, property, health, safety and general welfare of the public which requires that this ordinance shall become effective from and after the date of its final passage, and it is accordingly so ordained. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS on this the 18th day of October, 2011. APPROVED: ATTEST APPROVED AS TO FORM: ORD. NO. 4 New LOR BAY Conditional Application Package Regional Medical C Project No. 008703-156100 1650 West College Street at Grapevine Grapevine, Texas 76051 Date: October 10, 2011 INDEX OF DRAWINGS ---1 WEST COLLEGE STREET non —,T' �� �� m / / r IJU —� ° \Cott",,/ l ❑ U wwr.oT ^-i— O EXISTING CENTRAL 1 UTILITY PLANT - �; O 1 I ONE STORY \ / 1 - EXISTING PARKING GARAGE B TWO STORY EXISTING EXISTING i HOSPITAL �� BUILDING EXISTING (/ EXISTING BUILDING m ` EXISTING f ° o BUILDING ARKING GARAGE A j2�-- SIX STORY pp NEW Lflflt _ `_- �•,� l L�_� /_ 7i > TOWER ° --11_-- _ra.wmr _ _` , ` J?? . / /` , ✓ O /jv \-- / BUILDING EXISTINGco ti 4 00 / EXISTING 0 �- ..—� o r., •� / BUILDING (qlt o �o to o °o ��: ' ';"- _ EXISTING °O O p noxa I,I BUILDING LAN ITER DR, Q If �- -�`--_�-- Parking Count as of 09.20.11 - Existing Beds 296 Location of Parking Spaces PATIENT( VISITOR Types Of Parking Space STAFF PHYSICIAN HANDICAP CLERGY i RESERVED GARAGES Lipper Level 203 0 11 4 0 1 0 GARAGES Lower Level 1S6 30 4 15 0 3 EMPLOYEECIRCLE DRIVE 0 73 01 0 0 0 SOUTHEAST LOT 0 145 0 0 0 0 0 SOUTHWEST LOT 0 114 0 0 0 0 WOMEN CENTER LOT 149 0 4 0 0 0 POS EAST LOT 17 O 0g4o 6 o 01POB PHYSICIAN LOT 0 0 35SOUTHLOT 19 0 GARAGEA 2NDFL 157 167 0 0 GARAGEA 3RD FL 357 2 VALET (located inSouth Lot 13 01 00 151 0 0 0 Gaa e A by EDGARAGE 0 166 0 0 0 GARAGEA 6TH FL 0 A 1STFL 24 0 0 0 33 0 56 GARAGE A 2ND FL 0 157'. 0 2 0 1 0 GARAGEA 3RDFL 0 157 0 0 0 653 63 GARAGEA 4th FL 0 151 0 0 0 C GARAGEA STH FL 0 166 0 0 0 0 GARAGEA 6TH FL 0 128 0 0 0 Central Utility Plant 1 0 33 0 3 0 EMERGENCYROOM PHYSICIAN LOT 0 0 13 2 0 _ 1 Family Clinic 52 01 0 3 0 Sub •Total (bytype of paHngspare) 781 1154 67 69 21 62 Grand Total of all Parking Space Types 7771 2135 City of Grapevine Required Parking - 1022 Spaces 25pacesper Bed 592 (2966eds{ 5+aper 1505.F. 430 63,7245.F. MOB Parking Count after Expansion is Complete Location of Parking Spaces PATIENT/ VISITOR Types of Parking Space STAFF PHYSICIAN HANDICAP CLERGYRESERVED GARAGE Upper Level 203 a11 4 GARAGES Lower Level 158 4 15 0 3 E'MPLOYEEORCLE Om Removed for expansion protect SOUTHEASTLOT 0 145 0 0 0 SOUIHWESTLOT 114 0 0 0 0 WOMEN CENTER LOT 309 0 0 3 0 VALET (lorated in Women Center tot) 0 0 POBEASTLOT 21 0 0 4 0 POB PHYSICIAN LOT 0 0 35 0 0 SOUTHLOT 6 o v o GARAGEA IST FL 24 0 0 19 0 GARAGEA 2NDFL 157 0 0 0 GARAGEA 3RD FL 357 0 0 0 0 GARAGEA 4th FL 0 151 0 0 0 GARAGEA STH FL 0 166 0 0 0 GARAGEA 6TH FL 0 128 0 0 0 Cental Utility Plant 0 33 0 3 0 EMERGENCY ROOM PHYSICIAN LOT 0 0 13 2 0 1 Family Clinic 52 0 0 3 0 Sub -Total (by type of paring apace) 1029 653 63 70 0 60 Grand Total of all Parking Space Types 1875 City of Grapevine Required Parking - 1240 Spaces 2S aces per Bed 810 (405 beds) S+leer 1505.F. 4301 63,7245.F. MOB O 40 80 160 (FEET) 1 inch = 80 n. I mm HDR Archhecture, Inc. 17111 Preston Road. Suft 300 Dallas, TX 76246. 299 (972) 96P4000 CBRE CB RICHARD ELLIS PRDECT FOR BAYLOR Regional Medical Center at Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 SITE ORIENTATION PLAN / I I 1 WEST COLLEGE STREET / _ vrsaS7&65j—�ft°o S BLDG. SETBA(]( O O 0 _ q 7`�7 m� L_U PIANT 01TTM Opo \ \� ❑ r _` j 0 \�SrCO<<F \ ❑ EXISTING CENTRAL /"';fiord UT UTILITY PLANT ( �j p ONE STORY 1 77 'CE PLANTLLOT PLANT T_101.1B L_20228' \ 4 CB.NMr43'W ((( - CA20234' I l \\ (f f I It o I \ E\ ■� Ep -A \ a m \ EXISTING ^ \ o ARKING GARAGE A \ SIX STORY 22T -r \ \ \ 4 t D■o4roo•BD• RQ p _2✓W6.79' EXISTING HOSPITAL / I p NEW TOWER 0 0 EXISTING PARKING GARAGE B v TWO STORY (t 4 / = _ f E �- BI POB W C EASTLOrT f /V -P. v POB PMYSK.4W LOT \� • • "�\ ONE WAY G � 4 TZ.' L 020,.49• d-1 A $ nntR \ n, LAT •` 0 p O O PAOPERIY LINE 0._21'08'00= ` O O 0C ' � CBLtiw MASTERr — ` ^SIGN �'20'b pit. r _ C PARKING TABULATION • SEE C-001 SITE ORIENTATION PLAN FOR PARKING TABULATION BREAKDOWN. 1. CONDITIONAL USE REQUEST CU11-28 IS REQUEST TO AMEND THE PREVIOUSLY APPROVED SITE PLAN OF CU07-15 (ORD. 07-40), SPECIFICALLY TO ALLOW A FOUR STORY 167,939 SQUARE FOOT EXPANSION TO THE FRONT OF HOSPITAL 2. ALL ON-SITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSTRUCTION SHALL BE LOCATED UNDERGROUND. 3. ALL THE REQUIREMENTS OF THE GRAPEVINE SOIL EROSION CONTROL ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. CURRENT AND PROPOSED DATA FOR BAYLOR REGIONAL MEDICAL CENTER AT GRAPEVINE CURRENT HEIGHT OF EXISTING HOSPITAL: 90 FT 6 STORIES PROPOSED HEIGHT OF HOSPITAL: 90 FT 6 STORIES /v EXISTING ° BUILDING TOTAL EXISTING BUILDING AREA (BREAKDOWN): r 1 ,"r EXISTING HOSPITAL AND MOB: 483,549 S.F. ga+TEx . TWO LEVEL PARKING GARAGE: 141,860 S.F. �/ CENTRAL UTILITY PLANT: 17,108 S.F. \ / SIX LEVEL PARKING GARAGE: 323,675 S.F. TOTAL (EXISTING): 966,192 S.F. EXISTING BUILDING / ° y TOTAL PROPOSED BUILDING AREA (BREAKDOWN); ° TOTAL (PROPOSED): 167,939 S.F. 85 FT 0 IN 4 STORIES ° _ / w/ 5th FLOOR (FUTURE): 200.414 S.F. 100 FT 0 IN Q. s / °O \,J •, p TOTAL LOT AREA 1,109,787 S.F. ,i 0 / TOTAL IMPERVIOUS AREA: 800,959 S.F. (72X) '. y. SOUiFEAST ° O, _ Lor E TOTAL OPEN SPACE (LANDSCAPE): 308,828 S.F. (26%) E ° FAR = TOTAL BUILDING = 1,134,131 S.F. = 1.02 _ .cr'� / TOTAL SITE 1,109,787 S.F. TOTAL PAVING + TOTAL BUILDING = 1,520,211 S.F. ,50Y \ \\ O' � \-= , LEGEND: \ Op O, \ °\ -•v-per/ `•� ° �j /�\� ( PROPERTY UNE O EXISTING CURB EXISTING EDGE OF PAVEMENT ExlmNc TREE o EXISTING NEW EDGE OF PAVEMENT r TaIN.70' i L�557.4C BUILDING 30 60 120 ''am- /� (FEET) NORTH 25 / / \ (a1/ f 1 Inch = 60 ft. i y f CASE NAME CASE NUMBER CU11-28 LOCATION: 1850 W. COLLEGE ST. GRAPEVINE, TX 76051 MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET: 3 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES HDR Architecture, Inc. 17111 Preston Road, Suite 30D Dallas, TX 752481283 (972) 9604000 RICHARDCBRE CB ELLIS SWASSOCIATES SIS✓a RLG PROJECT FOR -, BAYLOR Regional Medical Center at Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 DIMENSIONAL CONTROL SITE PLAN SCALE III= 57� C-101 Use 00 EXISTING HOSPITAL V 1 -----TAL C:u f� )� v • �s .. _. _ 1s i _ nI / ------ ----- oOooO b l �A , �/ T L - -- -1 -- - 1 ------ - -- __ - -- --- --- -- - - - --- b 4 617 �o --- ---+-- - ---- -- / �-7 l 0 ,,,, - _ LEGEND: `\ 0 PROPERTY LINE �- \ C EXISTING CURB -EXISTING EDGE EDGE OF PAVE PAVEMENT 0 / CO O EXISTING TREE IRE LANE `! NEW EDGE OF PAVEMENT o O ``` CONSTRUCTION FENCE © til J i / 7 \` / tilUTTTLJ7 _ 0 0 ��� CO ` 1 / �' /'. ♦ / \0 '�% \ 0 30 60 120 i inch ft. NORTH CASE NAME GSE NUMBER CUA 1-28 LOCATION: 1650W. COLLEGE ST. GRAPEVINE, TX 76051 MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION HDR Architecture, Inc. 17111 Presto, Road. Sum SOD Dallas, TX 75248-1— (972) 95040DO 524&1259(972)95040DO RICHARDCBRE CB ELLIS SN✓a .:. _... R LG PRGECTFOR ABAYLOR Regional Medical Center at Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 TEMPORARY ENTRANCE PLAN CHAIRMAN SCALE DATE: SHEET:' 9 C-201 APPROVAL DOES NOT H ANY CO E ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES Conditional Use Applicatio II IJ WEST COLLEGE STREET `\ / �75 BLDG 6L'TBM:R t• ��v fill.... Hu u - RANT LDT a ❑ EXISTING CENTRAL' PHYSICIAN LOT O UTILITY PLANT \\ I ONE STORY Q \ \ 71T 2�! CEN111A1 LOT PTANTLOT _ \ k I \ I \ II 0 o- A \� � c'AT1 \ L EXISTING Z \ o ARKING GARAGE A \ SIX STORY �P 'n \ \ Q \ TT�8�pp777 i} ti ti 0 O o aQ I 2S N EXISTING HOSPITAL NEW TOWER o 1z a 9, MASTER PLANT LIST TYPE I KFYI ON. SCIENTIFIC NAME COMMON NAME SIZE REMARKS STAKING/SPACING TREES OS - OV - SNUW ROtl ERCUS VIRUNWU RE5 iii LIVE OAK 12-16 Hr—;8—'V SP. 3' CAL 12-16 HT:a-12 SP., 3 CAL SINGtE-LEAD StRA1CHf THUNK SINGLE -LEADER 51— TRUNK NO NO CC - U - CERCIS CMNDEN55 IAGER5TR0EMN INDICA NATCHQ EASTERN BUO CRAPE MYRTLE W11CHQSP. B-10 HT: SP. 2 CAL 2 GL - SINGLE -LEADER, STRAIG LINK, NO SHRUBS 00 - GRASSES CD - EKXITELOOA DACIYLOID6 CYNODON DACTYLON BUFFALO GRASS COMMON BERMUG SEEDED SODDED AS SHOWN AS SHOWN EC I ERAGROSTIS MWA- WEEPING LOVE GRASS 3 GAL: 30' HT., 24' SP. DENSE FOLIAGE IC ILEX CORNUTA 'BURFORDII HANK DWARF BURFORD HOLLY 5 GAL; 24' HT., 18' SP. DENSE FOLIAGE N REX VOMRORU 'HANK DWARF YAUPON HOLLY 3 GAL: 24' M.. 24' SP. DENSE FOL{GE NC - MUNIENBERG1A CARRLIRIS GULF WUHLY GRASS 3 CAL.: 30' W., 24• SP. OENSE FOLIAGE MS MISC/WIHUS SINEN55 GRACKUJUS MAIDEN GRASS S CAL..: SO HT., 24 SP. DENSE FOLIAGE ND NAND NA DOM GULF STREAM GULF SIRFAY NWDIU GAL: .. 4 DENSE FOLIAGE RI - RAPHq IS MUG PINKIE PINKIE MOWN fNWMORN 3 : 30 M., 24 SP. DENSE FOLIAGE SG - SALVIA GREGGB AUTUMN SAGE 3 GAL: 30• Hf. 24' SP. DENSE FOILAGE SN SPOROBOUS HETEROEPIS PRMBE DROPSEED 3 GAL; 30' Hf, 24' SP. DENSE FOLIAGE EXISTING PARKING GARAGE B TWO STORY U L PHYSICIAN OT c0<<FGEs \ � D o Q 00 LANCASTER 77 DR. --.� P® EXISTING °r BUILDING N ? EXISTING _ BUILDING \.. c� 'r\. CJC O 6 el~T� illi D o�� O �%r OT , �)Ib Lt1(r e � e EXISTING TREE CALCULATIONS RELOCATED OR REMOVED TREES OTY OESCRIPf10N 44 - CRAPE M'fRitES 2 - 8• CAK 1- 5' OAK 1 - 9 OAK 1 -1T GK -15' OAK - 4' OAK i -15' BP PROPOSED TREES QTY, DESCRIPTION 34 - 3' RED OAKS 49 - 3• LIVE OAKS 21 - RED BUDS 61 - CRAPE MYRTLES 15 - JAPANESE MAPLES.---. LEGEND: TREE PLANTING DETAIL mm xNt sn tM.t L_ vnAe¢1Pa4 a�''Oa lmJ .: SVvz 0*J METAL EDGING xur m a>tc SHRUB PLANTING DETAIL til KaT m LANDSCAPE CALCULATIONSCOMMUNITY COMMERCIAL DISTRICT REQUIRED - 30% OF TOTAL LOT AREA SHALL BE DEVOTED TO NON- VEHICULAR OPEN SPACE. PROVIDED - 1,144522 SF. TOTAL LOT AREA 343,563 SF. NON -VEHICULAR OPEN SPACE OR 30% REDURED - COMBINED AREA OCCUPIED BY ALL MAIN AND ACCESSORY STRUCTURES SMALL NOT EXCEED 60% OF TOTAL LOT AREA. PROVIDED - 1,144522 SF. TOTAL LOT MFA 390,536 SF. STRUCTURES OR 34% REOUIRED - COMBINED AREA OCCUPIED BY ALL MAIN AND ACCESSORY STRUCTURES. PARKING. STORAGE. LOADING AND OTHER PAVED MEAS SHALL NOT EXCEED 80% OF TOTAL LOT AREA. PROVIDED - 1.144.522 SF. TOTAL LOT AREA 800,959 SF. STRUCTURES MO PAVING OR 72% REQUIRED - PERIMETER LANDSCAPE AREAS SHALL CONTAIN AT LEAST ONE TREE FOR G 50 LINEAL FT. OR FRACTION THEREOF OF PERIMETER AREA PROVIDED - AS SHOWN NOTES: 1. REPLACE ALL EXISTING TURF DISTURBED DURING CONSTRUCTION WITH NEW SOD. 2. ALL LANDSCAPED AREAS TO BE IRRIGATED WITH AUTOMATED IRRIGATION SYSTEM. NEW IRRIGATED AREAS TO UTILIZE EXISTING IRRWGATION EOUIPMENT IF POSSIBLE. 3. ALL EXISTING TREES TO REMAIN, PROTECT AS NECESSARY. BUILDING 0 30 60 120 0 I inch = 60 ft. CASE NAME: CASE NUMBER CU11-26 LOCATION: 1650 W. COLLEGE ST. GRAPEVINE, TX 76051 MAYOR SECRETARY DATE PLANNING AND ZONING COMMISSION HDR Architecture, Inc. 17111 P—X n Road, StAl. 300 Dallas, TX 75248-1299 (972) 960<0W CBRE CB RICHARD ELLIS sw ASSOCIATES PROJECT FOR oBAVLOR Regional Medical Center at Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 SITE LANDSCAPE PLAN CHAIRMAN SCALE 1'�1tP41' DATE: SHEET` 5 OF 9L-101 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPAMMEW OF DEVELOPMENT SERVICES Conditional Use Applicatic PROPERTY UNE EXISTING CURB EXISTING EDGE OF PAVEMENT i EXISTING TREE SOD AREA BUILDING 0 30 60 120 0 I inch = 60 ft. CASE NAME: CASE NUMBER CU11-26 LOCATION: 1650 W. COLLEGE ST. GRAPEVINE, TX 76051 MAYOR SECRETARY DATE PLANNING AND ZONING COMMISSION HDR Architecture, Inc. 17111 P—X n Road, StAl. 300 Dallas, TX 75248-1299 (972) 960<0W CBRE CB RICHARD ELLIS sw ASSOCIATES PROJECT FOR oBAVLOR Regional Medical Center at Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 SITE LANDSCAPE PLAN CHAIRMAN SCALE 1'�1tP41' DATE: SHEET` 5 OF 9L-101 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPAMMEW OF DEVELOPMENT SERVICES Conditional Use Applicatic Decorative metal screen -- — —� Exterior Insulated Finish System over air barrier on exterior sheathing over exterior stud wall system, typical — Curtain wall system wdhinsulated=_ _ EXTERIOR ELEVATION -WEST ZC in6•=r-o• ��LEV_E4 L v 48'-0-0•— — �__LE�VEL 3 _ 110 33' - 0" — -- — — E�VEL 2 V 118' - 0" EXTERIOR ELEVATION -EAST 2A vs•s,.-0. Fire Department Clearances Considered I Future Expansion: 5th floor and Penthouse Curtain wall system with insulated exterior glazing (U -value; 26) Aluminum awning system i with wood panel on soffit Decorative metal screen 0 Face brick/stone colui m ---------------- Future Expansion: 5th floor and Penthouse Curtain wall system with insulated exterior glazing -(U -value; 26) _ Aluminum awning system with wood panel Aluminum metal panel over fluid applied air barrier on exterior sheathing over exterior stud wall system Exterior Insulated Finish System over ♦ ♦ ♦ air barrier on exterior sheathing over FUTURE exterior stud wall system, typical �EXPANSION -too'-o°—gluminum sun control system ROOF Curtain wall system wfth insulated exterior glazing (U -value, 26) _ ELECTRICAL ENGINEER SWAFMIN— STAIR ROOF Stone veneer over fluid applied air 74' - 0" rrier on exterior sh hing Aver T.O_PARAPET exterior stud wall syster 1, typical - -��:- ��� 69 -0 - LEVELS \/ 63' - D"_ __ �' - _ _ _ kr.-v�4't.' .- ��LEV_E4 L v 48'-0-0•— — �__LE�VEL 3 _ 110 33' - 0" — -- — — E�VEL 2 V 118' - 0" EXTERIOR ELEVATION -EAST 2A vs•s,.-0. Fire Department Clearances Considered I Future Expansion: 5th floor and Penthouse Curtain wall system with insulated exterior glazing (U -value; 26) Aluminum awning system i with wood panel on soffit Decorative metal screen 0 Face brick/stone colui m ---------------- Future Expansion: 5th floor and Penthouse Curtain wall system with insulated exterior glazing -(U -value; 26) _ Aluminum awning system with wood panel GENERAL NOTE: EXCLUDING WINDOWS AND DOORS, THE EXTERIOR ELEVATIONS ARE COMPOSED OF 981% MASONRY FUTURE EXPANSION n 1001-0. V ROOF n 85 (I0 _ - ST AIR ROOF._./1 T.O. PARAPET_ 69'- 0• LEVEL 5 /\ 63' - 0" -V _ LEVEL.4_./1 48'-0" lI _ LEVEL tl 33: o— �-w HDR Architecture, Inc. 17111 Preston Road, Suite 300 Dallas, TX 75248-1299 (972) 9604000 CBRE CB RICHARD ELLIS SW ASSOCIATES ® u„ PROJECT FOR oBAYLOR Regional Medical Center at Granevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 P!CTNUNBFR1B08i@1156180 DRIGI MSUE A28110H ° __- PRGECTARCHnECT Lei�fttll CMLMNEER f5 -G. Ine. ♦ ♦ ♦ I ♦ ♦ ♦ ♦ _ STRtGUTALENGBEER RLG,kc --.... GENERAL NOTE: EXCLUDING WINDOWS AND DOORS, THE EXTERIOR ELEVATIONS ARE COMPOSED OF 981% MASONRY FUTURE EXPANSION n 1001-0. V ROOF n 85 (I0 _ - ST AIR ROOF._./1 T.O. PARAPET_ 69'- 0• LEVEL 5 /\ 63' - 0" -V _ LEVEL.4_./1 48'-0" lI _ LEVEL tl 33: o— �-w HDR Architecture, Inc. 17111 Preston Road, Suite 300 Dallas, TX 75248-1299 (972) 9604000 CBRE CB RICHARD ELLIS SW ASSOCIATES ® u„ PROJECT FOR oBAYLOR Regional Medical Center at Granevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 P!CTNUNBFR1B08i@1156180 DRIGI MSUE A28110H EXISTING BUILDING (SECTION CUT) MAYOR SECRETAR,EXTERIOR DATE: ELEVATIONS PLANNING AND ZONING COMMISSION CHAIRMAN DATE:--- SHEET: ATE:_—SHEET: 6 OF 9__ L � A/1o� APPROVAL DOES NOT AUTHORIZE ANY H WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES Conditional Use Applicat ° __- PRGECTARCHnECT Lei�fttll CMLMNEER f5 -G. Ine. ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ _ STRtGUTALENGBEER RLG,kc --.... MECHANICAL ENGINEER SWAEr9d ELECTRICAL ENGINEER SWAFMIN— n +d� } a j.'•.••855t "d• PO 'TFor< w11I GA$E NAME: CASE NUMBER: CUi 1-28 LOCATION: 1650 W. COLLEGE ST. GRAPEVINE, TX 76051 EXISTING BUILDING (SECTION CUT) MAYOR SECRETAR,EXTERIOR DATE: ELEVATIONS PLANNING AND ZONING COMMISSION CHAIRMAN DATE:--- SHEET: ATE:_—SHEET: 6 OF 9__ L � A/1o� APPROVAL DOES NOT AUTHORIZE ANY H WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES Conditional Use Applicat E Exterior Insulated Finish System over air barrier on exterior sheathing over exterior stud wall system, typical -- Aluminum sun control system -- --- Curtain wall system with insulated exterior glazing (U -value, 26) ---- Aluminum awning system with wood panel on soffit - Face brick/stone column system, typical ---- ROOF ���T_��.�. PARAPET v 69' -0• — - VEL 5 lii�_ 0. -- A LEVEL _. �J 48'- 0" — !l 33. - L — VEL 2 _ \j11 g' -0. Future Expansion: 5th floor and Penthouse - Aluminum metal panel over fluid applied air barrier on exterior sheathing over exterior stud wall system - Curtain wall system with insulated exterior glazing (U -value; 26) - Stone veneer over fluid applied air barrier on exterior sheathing over - - Main Entry Canopy 2C EXTERIOR ELEVATION -SOUTH MAIN ENTRY Aluminum metal panel over fluid applied air barrier on exterior sheathing over exterior stud wall system Exterior Insulated Finsh System over air barrier on extenoissheathi'mg over exterior sts�wall system, typical — Future Expansion: 5th floor and Penthouse Aluminum awning system with wood panel on soffit Decorative metal screen system,-typlcaf - 4 I i 4--e.J :' c T' - - tE VEL - th Stone veneer over fluid applied air insulated elxterioemlazlin barrier on exterior sheathing over EXISTING BUILDING (SECTION CUT) (U -value; 26) g g exterior stud wall system, typical -- - - - -- _ — _ — - _ LEVEL i —----------- - - o. -o. EXTERIOR ELEVATION -NORTH 2A vs• e r-0• HDR Architecture, Inc. 17111 Preston Road, Suite 300 Dallas, TX 75248-1299 (972)96040DO RICHARDCBRE CB ELLIS SIN ASSOCIATES SVI/a ' R LG PROJECT FOR BAYLOR Regional Medical Center at Granevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 -r E Ew, PROJECT NUMBER M70156100 •� ORIGRIALISSUE SUM11 PROAECTMANAGER CtaMa Daus PROJECTMANAGER Chwin L.N.I PROJECT DESIGNER Dan Thares --- PROIECTARC1iItECT Leigh Pawn _ CMLENGINEER RLG, Inc. STRUCTURAL ENGINEER MG, Ine MECHANICAL ENGINEER SWAEngi—. I CASE NAME. FUTURE CASE NUMBER: CUI 1 28 EXPANSIO... N... n Too' ll LOCATION: 1650 W. COLLEGE ST. -o° C------� ROOF m -N MAYOR SECRETARY STAIR ROOF DATE: 74'- 0" PLANNING AND ZONING COMMISSION T.OPARAP�ET_ A CHAIRMAN - 69' Q' LP _ - - LEVEL 5 n SHEET: 7 OF 9 - LEVEL 4 /1 H-202 _ 0. - 4 I i 4--e.J :' c T' - - tE VEL - th Stone veneer over fluid applied air insulated elxterioemlazlin barrier on exterior sheathing over EXISTING BUILDING (SECTION CUT) (U -value; 26) g g exterior stud wall system, typical -- - - - -- _ — _ — - _ LEVEL i —----------- - - o. -o. EXTERIOR ELEVATION -NORTH 2A vs• e r-0• HDR Architecture, Inc. 17111 Preston Road, Suite 300 Dallas, TX 75248-1299 (972)96040DO RICHARDCBRE CB ELLIS SIN ASSOCIATES SVI/a ' R LG PROJECT FOR BAYLOR Regional Medical Center at Granevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 -r E Ew, PROJECT NUMBER M70156100 •� ORIGRIALISSUE SUM11 PROAECTMANAGER CtaMa Daus PROJECTMANAGER Chwin L.N.I PROJECT DESIGNER Dan Thares --- PROIECTARC1iItECT Leigh Pawn _ CMLENGINEER RLG, Inc. STRUCTURAL ENGINEER MG, Ine MECHANICAL ENGINEER SWAEngi—. I CASE NAME. CASE NUMBER: CUI 1 28 LOCATION: 1650 W. COLLEGE ST. GRAPEVINE, Tx 76051 EXTERIOR MAYOR SECRETARY DATE: ELEVATIONS PLANNING AND ZONING COMMISSION CHAIRMAN SCALE 1116•=1•,0• DATE: SHEET: 7 OF 9 APPROVAL DOES NOT ANY H-202 WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES Conditional Use Application R 76 61/2 33� 6 3' 61/1 - egio al Medical Center i w 1450 TEST COLLEGE - I I 1 Me.1wMA-FwM9.01" sdwr-rr IM 1. Imai mbaro by odes. 2. 3' diarwta dmenum past tamed bamaA the EMIRG[Ky box to he punted to match PT SX'm. Mae v -MAS dw 2 SAewf=I'r 3. 3'Rick smmds has Austin b1tach t, (adm Crean cca ft a awek fimc Mr. W. Nmh- hhW,ftick.cm) Tams Quotes 1800111WaYestane Bad. (eb Pak, IX 78613 (512) 2581474 http://ww.Rmsqunies.mn 4, two aA, lactam Aslla Prom Anbn Umalme, Cadam Cmm as mmlabla ban lams Qmries-seema 3. S. A "W" 3M Mmmd Gude RdkcRM Rad 3992. 6. Fabricaed duRkm Burro bepahW homach Pd V,&. 7. 6'W m" far. klan Loa" (allow Amo, ca amBdlle fico Texas B. i/B'IbYb Men'rxmfdxknled>gn bad d xmdas welded mBhmtion. I/8' SiF had ro ba mladad to aneaatepawJ-a, aimmnm mbf." ad cmm�mAk maws m be pamtedb mad M Sim. 9. 1'deepfdxia add mala , Nxnblaled dannd Man Wed ha mall P2 Ble. AMwak paneled bP 0w .. le8mst hesaudmautedad roll d m sand vele.f * bad. 10.1/4• b w act ahmrr am rue aercmed W. patted ro mad P3 Block. 0.h,wk mailed 6y Oma. left robe Aud narntei and arced w sxad date d sips bad. 11. dBsIm3M Radli e 5 12. Gael mowed 40 f mm See Sleet F3 fa W furore dells. 13. tlokhsiCm hox ro d6w Tnlagwcy" sal late m fit 116h w8h odacatf dammamsr had. 14. Goutta.0 tmlestmle edn. 15. Refa to sheers C -I ad C-2 far 91-6• 3 M:!V -sN` B -"Ne Mwr1eMA -SW.8n R. s�ar•rr sAewrorr 2. 3' dwnela dBrim m pm cemmd b -A Ila EM9lGB[['f box to be pwaw mlmdl P1 5d.. 3. 3' mA MMA face ktri toe" Cadma (rem UM as owI ham Mr. DuSWI Nadi- (dlah4�Iakk.taml le» Amies 1800 W WWa a m Bad. Leda Pak, 1X 78613 (512) 2581474 Blip_//NWM.100"F la mmuca 4. Roughs at, adan Atha Poem kraim ltusmne, Callow Crean a mw'lobk hm fms OumMs-see rock 3. 6. F*imed Ani m box to be primed to mad M White. 7. b'Natk smmhfae Aoa'm timatola condom (smn, a mmldiefmn Tem aalkl-sm me 3. 8. I/8' Nhdc duumn (ddaled sgn bad dseaden weNf� toanwNan. 1/8' Sgl had to be onahedro RmeaaupwN m m dunawm YAfmam ad cmeesek mwws to be to and PI Sint, 9.1' deep fabkm0i dJK- ma &minted demd Met pahmd m RuMI P2 Mae. MMakp Mad by OAns Imm robe and mom ad arcedwshadsaled4pl End. 10.1/a'ihtadmakmkmm 9immamddand lallnsplum to .0 P3 Black. NMak padded b/ 0m%. Inas ro be sad atema dad tatted m shad side d sips bad 12. Gland mound I#fimee: See 9W 1-3 fa 4#11Aoe Themis. 13. tPoRh sips baxtad w'Enmgmy * harm ht W whi, epam amemn sign brA 14. GRAN match liamatome talar IER HDRArchitecture, Inc. 17111 Preston R-1, Suite 300 Dallas. TX 75248-12- (972) 96011CM 5248-1299(972)96014000 CBRE CB RICHARD ELLIS ®SAS �IAT6 ® u. PROJECT FOR ) BAYLOR Regional Medical Center T In Grapevine New Patient Tower Conditional Use Application Package 1650 West College Street Grapevine, Texas 76051 PROAECTNUYBER DWOb156100 ORIGINAL SSUE IMI&H PROJECT MANAGER CrzMIe Data •- PROJECTMANAGER Ganes Lambed PROJECT DESIGNER Dan Tlgms PROJECT ARCHITECT Leon P11-- __. CML ENGINEER RLG. Inc STRUCTURAL ENGINE ER RLG.I MEnc. GIANICAL ER SWA EngNeers ELECTRICAL ENGNFER SW0. Engbaem pE A A 4 LL G # 1 r •.,wssT.rtpg TTFor- �lh CASE NAME: CASE NUMBER: CUII-28 LOCATION: 1650 W. COLLEGE ST. GRAPEVINE, TX 76051 PROPOSED MAYOR SECRETARY DATE _ MONUMENTAL SIGN PLANNING AND ZONING COMMISSION LANCASTER @ BAYLOR DRIVE COLLEGE @ 2 LEVEL PARKING GARAGE CHAIRMAN SCALE 3M'=1'4Y DATE: SHEET: 8 OF 9 /l7 1 A APPROVAL DOES NOT AUTHORIZE ANY /{`�� -30 1 WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES Conditional Use ADDIICation Package IP �H AMILY LIM�Og50)mEp, HEDGE 9,5 j24�. POINNNjI A=51vl,28' w BEa, R » gX N 585 Lg=N43tM 09 E' - s- N Ain N 3310525' 25.36' DLOG"RES, 69 R160153 P 23 �. 3g' LOT BL°EGREsp. 72 Q SI D0. l0OT -- 0 88�2 GE J 4 0 O�E 24 / .M • JI 5' s 5'S 0659 50' E 73. 11' fi r 4=212102" R=536.90' T=101.21' L=200.07' C8=N7935'11 E CD=198.91 ' WL 2T t sR OGE �kESP 25 =O S RID 3a0 GE 2k sP 25 Q ;'IT, ESP g5 W D J 388 W Os J 38a oz or or J to mr N ver L" TO m I+ J0 'K / o� S 8944'18" E S 8944'18" E STREET 202 69..51' 4' 2 2 n-ees Mzrwxxw i I 10 i N 007542' E S 007542' W 3.92' �- I92' 60' e v.o.w LOT or S 894418' E S 894478' E R 202.51 26.24 J 0 e =fie h p•' S Py S 89 44'18' £ 500' LINE TABLE A=154055" LINE BEARING LENGTH L 1 ' ' E N0375 3 1 51.15' L2 N370748"W 76.97' L3 1V21070l'W 15.61' 14 N685259 E 2500' L5 N210701 "W 20.00' L6 5685259W 20.00' L7 5210701E 5.00' L8 S685259"W 20.00' L9 S210701 E 3272' L 10 S370748 E 7357' LIE 5037531 "W 38.96' L12 S2379'00"W 104.70' L73 S0858'15"E 10.00' L14 58101 45 "W 20.00' L15 N0658'15"W 2000'. L16 N8101'45E 8.58' L17 N2379 00 E 1 101.18' DLOG"RES, 69 R160153 P 23 �. 3g' LOT BL°EGREsp. 72 Q SI D0. l0OT -- 0 88�2 GE J 4 0 O�E 24 / .M • JI 5' s 5'S 0659 50' E 73. 11' fi r 4=212102" R=536.90' T=101.21' L=200.07' C8=N7935'11 E CD=198.91 ' WL 2T t sR OGE �kESP 25 =O S RID 3a0 GE 2k sP 25 Q ;'IT, ESP g5 W D J 388 W Os J 38a oz or or J to mr N ver L" TO m I+ J0 'K / o� S 8944'18" E S 8944'18" E STREET 202 69..51' 4' 2 2 n-ees Mzrwxxw i I 10 i N 007542' E S 007542' W 3.92' �- I92' 60' e v.o.w LOT or S 894418' E S 894478' E R 202.51 26.24 J 0 e =fie h p•' S Py S 89 44'18' £ 500' 468.27' CURVE DELTA A=154055" A=040436" o rA u ' R=517.50' R=2843.00' caa 3 4> T=71.27' T=101.18' >- ".G Vis. L=141.64' L=202.28' 752' CB=57322:32"W, CB=N3507 43"W C3 014'49'06" CD=141.20' CD=202.24' LOT 1A, BLOCK A N6234 28"W 96.72- C4 0053421" GRAPEVINE MEDICAL CENTER ADD17701V 1752' 1,109,787 SO. FT. N5859'54"W 3500' 25.4772 ACRES „N 3770101" W J. 3 468.27' CURVE DELTA G7 LB1-L4 c'., o rA u ' STATE OF TEXAS ✓� � aAr sar ` caa 3 4> o A=4793.26' R=350. V .ti •4 � � v 'P' •1 Cl r,56.75' - l' 4 F.` CURVE DELTA RADIUS TANGENT LENGTH STATE OF TEXAS C1 00236'47" PARCEL roe c' DOC. No. 710229656 >- ".G Vis. R=2886.79' T=100.81'a L=201.53' CB=1V3519525'W CD=201.49' CURVE TABLE CURVE DELTA RADIUS TANGENT LENGTH CH. BRG CHORD C1 00236'47" 360.00' 8.21' 16.42' S624528C 16.42' C2 0027756" 37500' 752' 1505' 5710759E 15.05' C3 014'49'06" 375-00' 48.76' 96.99' N6234 28"W 96.72- C4 0053421" 360.00' 1752' 35.01' N5859'54"W 3500' NCYN/TY MAP NOT TO SCALE A r 9 E ciao r � vnu7k sur MiM E Mutat M'4. LEGEND ms/wr _.. ser/raxar _ a os ra A%1,1 IAI r...._.. [rrlaAL PUB''/L'MCReRS 7AlwANr CWxrr, irxvs R=3750[1' Q A OGS �P t GC' � y is �4 8 k a LOT -A IIa ryi LOT JS 8978'12" E h � .-- 244.71 _ WS- -WS- ----- �Fy se9Te 12 E 2 _to �S S 004148' W 12206' t • •h '41x0 •,� LOT 4 5 A=795032" r C� tiQPQ 0 R=400.00' o�� ,• T=334.70' 0�P2e7ry L=557.40' C8=S4O37 04 "W J' T-1.1220' CD=513.39' " CB=SBBT753•W ��\�\L,s. I� C0=249.36• C _ N 330525' W 146.53' egpMc -- LOT u OG�4 PPRP AO -;t--3.95.40. S 80 32 20.c�EPRP s _._toaRPR e33 n GPe 4=21 ne'Do" o�E� E 3 a=28d00• 0 Lt0 R=2BO.Oo' R=280.00' PR s O 7=947• L_1893• T=52.23' Gpe Cs=O6 •w L=103.28' CO=Id9X 1893• CB=S695820'W A V4GA 7701V RELEASE CD=102.69' THE STATE OF TEXAS § COUNTY OF TARRANT § WHEREAS, - hereinafter called "Owner" (whether one or more), is the owner of that certain parcel of land situated in the City of Grapevine, Tarrant County, Texas, being more particularly described as shown on this plot. NOW THEREFORE, in consideration of the sum of ONE AND 00/100 ($1.00) DOLLAR and other good and valuable consideration, the receipt and sufficiency of which is hereby fully acknowledged and confessed, Owner does hereby waive, release, r m se and quitclaim to the City of Grapevine,Tarrant County, Texas, the Dallas -Fort Worth International Airport Board the flies of Dallas, Texas and Fort Worth, Texas, their successors and assigns, hereinafter called "Cities" for the use and benefit of the public and its agencies, any and oil claims for damages of any kind to persons or property that Owner may suffer by reason of the passage and flight of at/ aircraft in the air space above Owner's property above the height restriction- presently established by Ordnance Na- 73-50 for the City of Grapevine, known as the Aipwt Zoning Ordnance of the Dallas -Fort Worth Intemational Airport, to on infinite height Oboe same, whether such damage shall originate from noise, vibration, fumes, dust, fuel and lubricant p-6,1.., and o// other effects that may be caused by the Operation Of? crof[, 1, ding trona/ Ai at, or taking off from, or operating at w on the Dol/os-fort Worth lntema p This instrument does not release the owners or operators of aircraft from liability for damage or injury to person or property caused by falling aircraft or falling physical objects from aircraft, except as stated herein with respect to noise, fumes, dust, fuel, and lubricant particles. It is agreed that this Release shall be binding upon said owner and his heirs and assigns, and successors in interest to said property, and it is further agreed that this instrument shall be a covenant running with the land, and shall be recorded in the Deed Records of the county or counties in which the property is situated EXECUTED at -__-- Texas, this _ day of ____-___. 2011. OWNER ERE The State of Texas § County of Dal/as § Before me, the undersigned outh-ity on this day persona//y appeared --_--- known to me to be the person whose name %s subscribed to the foregoing instrument and acknowledged to me that he executed the some for the purposes and consideration therein expressed Given no, my hand and seat of office this day of __, 2011. Notary Pub/ic in and for the Stafe of Texas BASIS OF BEARINGS: THE NORTHEAST RICHT-OF-WAY LINE OF STATE HIGHWAY NO 114 PER GRAPEVINE MEDICAL CENTER ADDITION, CAB. A, SLIDE 1036, P.R. TC 1. IN 337538" W) ALL PRE-EXIS771VG EASEMENTS IDENTIFIED HEREON BY VOLUME AND PAGE ARE SHOWN FOR INFORMA 77ONAL PURPOSES ONLY AND NOT INTENDED TO BE DEDICATED AS FUBLIC EASEMENTS PURSUANT TO THIS PLAT. EXISTING ZONING - PCD PROPOSED ZONING - PCD RICHT-OF-WAY OEDICA)ION - 0.7974 ACRES EASEMENT DEDICA 77ON AREA - 0.4381 ACRES NET PLATTED AREA - 25.4772 ACRES TOTAL PLATTED AREA - 25.4772 ACRES OWNER'S CER77F/CA TE STATE OF 7EXAS § COUNTY OF TARRANT § W YEREAS, Grapevine Medical Center is the owner of a tract or parcel of land situated in the City of Grapevine, Tarrant County, Texas and being part of the Ambrose Foster Survey Abstract No. 518 and being part of Lot 1, Block A, of the Medica/ Center Addition, an addition to the City of Grapevine. Texas as recorded in Cabinet A, Slide Tarrant Count Texas and being more articular/ 12026, 0! the P/af Records of a 202 , particularly Y• 4 described as follows: BEG/NN/NG ata Tx Dot Brass Disk found for corner 0t the intersection of the northeastsry right of way line of Stole Highway No. 114, (variable width), with the W College feel from centerline southeasterly right -of way line of est Co Street 34 g ( ). THENCE North 6854'40" Cost along said sOutheoeteny right-of-way line of West College Street a distance of 575.65 feet to 0 1/2' iron rod with yellow plastic cop stamped RLC" set for comer at the beginning of a curve to the right; THENCE in an easterly direction continuing along said West College Street right-of-way line and along said curve to the right, whose chord bears North 7935'11' East a distance of 198.91 feet, having a radius of 536.90 feet, a central ang/e of 217102" and an arc length of 200.07 feet to a 1/2" iron rod with yellow plastic cop stomped REG" set for corner of the end of said curve to the right; 7HEWCE South 8944'18" East along the southerly right-of-woy line of said West College Street a distance of 202.51 feet to a 1/2" iron rod with yellow plastic cop stamped RLG" set for corner, IHENCE North 0075'42" East along an offset in said West College Street right-of-woy line a distance of J. feel to a 1/2' iron rod with yellow plastic cap stamped "RLG" set for comer (30.08 feet from centerline of this point); 7HEWCE South 8944'18" East continuing along said right-of-way line (3008 feet from centerline) o distance of 500 feet to a 1/2' iron rad with ye/low plastic cop stamped "REG" set for corner, ]HENCE South 007542" West along an offset in said West College Street right-of-way line o distance of 392 feet to a 1/2" iron rod with ye/low plastic cop stomped RLG" set for corner (34 feet from centerline), THENCE South 894418 East along the southerly fight -of -way lne of said West Collegee Street a distance of 269.24 feet to a 5/8" iron rod found for comer at the northeasterly corner of Lot 1, Block A of said Grapevine Medical Center Addition and the northwesterly corner of Lot 11-8, Block 1 of the Rep/at Lots 11-A and 11-6. Black 1, C/eerview Park, on addition to the City of Grapevine, Texas as recorded m Cabinet B, Slide 72 of the Plot Records, Tarrant County, Texas; THENCEon fine between said Lot 1 Block A Gmpsvi Soath 000670 fast along the comm Grapevine Medical Center Addition and said Lots 11-A and 11-8, C/earview Pork Rep/at, a distance of 408.66 feet to a 5/8" iron rod found for comer of the beginning of a curve to the right; THENCE in a southwesterly direction continuing ve/erngcommon line and along said THEN to the right, whose chord boars South 137232" West a distance of 741.20 feet, having a radius of 51750 feet, a centro/ angle of 154055" and an arc length of 141.64 feet to a 5/8' iron rod found for corner at the southwesterly corner of said Lot 11-A.- THENCE 1-A;THENCE South 8978'12" East along the common line between said Lot I7 -A, C/earview Park Replat and said Lot 1, Black A, CropeNrle Medical Addition a distance of 244.71 feet to a 5/8" iron rod found for comer in the westerly right-of-way line of Lancaster Drie60 foot fight -of -way); ( 9 Y)• THENCE South 00'41'48" West along said westerly right-of-woy line a distance Of 122.06 feet to a 5/8" iron rod found f corner at the beginning of a cure to the right' 7HEWCE in a southwesterly direction along the northwesterly right-of-woy line of said Lancaster Drive and along said curve to the right whose chord bears South 4037'04" West o distance of 51339 feet, having a radius of 400.00 feet, a central angle of 795032" and on arc length of 55740 feet to a 5/81iron rod found for comer at the end of said curve to the right,, THENCE South B03220" West along the northerly right-of-way line of said Lancaster Drive a distance of 395.40 feet to a 5/8" iron rod found for toner at the beginning of a curve to the left, THENCE in a southwesterly direction, continuing along said northerly right-of-way line and along said curve to the left, whose chord bears South 695820" West a distance of 102.69 feet, having o radius of 28000 feet, a central angle of 2108'00" and an arc length of 10328 feet to a Tx Dot Brass Disk found for corner at the intersection of the northerly right-of-woy he of said Lancaster Drive and the northeasterly right-of-way line of said State Highway No. 114; THENCE continuing along the northeasterly fight -of -way line of said State Highway No. 114 the fol/owing courses, North 330525" West a distance of 146.53 reef to a Tx Dot Bross Disk (ound for corner at the beginning of a curve to the left, /n o northwesterly direction, continuing along said curve to the left, whose chord bears North 350525" West o distance of 201.49 feet, hawnq a radius of 2886.79 feet, a central angle of 0400'00" and an arc length of 201.53 feet to a Tx Dot Bross Disk found for comer at the end of said curve to the left.- North eft;North 377001" West along said right-of-way line a distance of 468.27 feet to a Tx Dat Bross Disk found for toner at the beginning of a cure to the right; /n a northwesterly direction along said curve to the right, whose chord bears North 3507'43" West a distance of 202.24 feet, having a radius of 284300 feet, a central ang/e of 040436" and an arc length of 20228 feet to a Tx Dot Bross Disk found for comer at the end of said curve to the right; North 330525" West a distance of 2536 feet to a Tx Dot Bross Disk found for comer; North 0659'50" Cost a distance of 7311 feet to the POINT OF BEGINNING and containing 1,109,787 square feet or 25.4772 acres of /and more or less. NAS SWOMN.O ACCESS 770 STA7F h%HWAY Na 114 EXCEPT NOW, THEREFORE WE KNOW ALL MEN BY THESE PRESENTS, THAT Grapevine Medical Center does hereby adopt this plot of Grapevine Medco/ Curter Add'tion, on addition to the City of Grapevine, Tarrant County, Texas, and does hereby dedicate to the public use forever the right-of-way and easements shown hereon. Tire easements shown hereon ore fit shall be en for indicated. The ufilit easeme s hereby reserved for the purposes as y p a// city - franchised public utilities for each particular use. The maintenance of paving on the easements is the responsibility of the property owner. No buildings Or auxiliary structures shall be constructed, reconstructed, or placed upon, over, or across the easements as shown. Said easements being hereby reserved for the mutual use and accommodation of a// public utilities using, or desinng to use some. Any City or k removed a0 or arts of franchised utility shat/ hove the fu// right to remove and keep p which in an cndan er or other im ro ents ogrowths r fences trees shrubs,Y way 9 Lilly P ✓e construction, maintenance or efficiency o fits respective s tem an theinterfere with theCityrfy p l the easements and o// City or franchised utilities shall at all Lures how the fu// right of ingress and egress to and from and upon said easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining, and adding to or emowig al/ or parts of its respective system, without the necessity at any time of procuring the permission of anyone. and l do that the ' � din s concerning dedo0tions a l has reviewed the C'tys g 9agree, statements are true and correct. r This plot approved subject to al/ platting ordinances, u/es, regulations, o resolutions rid of the City of Grapevine, Texas. Witness my hand this the --_ --- --- day of _-___-__-_. 2071 (Signature of rfs Thi State of Texas § County of ---- § Before me, the undersigned authority 0, this day personally appeared known to me to be the person whose name is subscribed to the foregoing instrument aril acknowledged to me that he executed the same for the purposes and consideration therein expressed Given under my hand and seal of office this y da of 201L Notary Public in and for the State of Texas SURVEYOR'S CER77FICA 7700' I, Dote R. White , of R mond L. Goodson, 4.. Inc., a Registered Profession/ Lord Survv yr of the State of Texas, do hereby declare that l prepared this plat from an actual and accurate survey on the /and and that the corner monuments shown thereon were properly placed under my personal supervision in accordance with the platting rules and regulations of the State of Texas and the City of Grapevine. Dale R. Wfiite R.P.LS No. 4762 Raymond L. Goodson Jr., Inc. The Stale of Texas § County of Dallas § Before me, the undersigned authority on this day personally appeared Dole R. White, known to me to be the person whose name is subscribed to the foregoing instrument any acknowledged to me that he executed the some for the purposes and corsiderot%on therein expressed Given under my hand and seat of office this day of . 2071. Notary Publicin and for the State of Texas CASE NAME: CASE NUMBER 01111-28 LOCATION: 1650W. COLLEGE ST. GRAPEVINE, TX TSM1 MAYOR SECRETARY DATE: MANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET: 9 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT NTH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES AMENDING PLAT LOT 1A, BLOCK A R ADDITION GRAPEVINE MEDICAL CENTS A. FOSTER SURVEY, ABSTRACT No. 518 CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS SCALE- 1"= 100 OWNER: GRAPEVINE MEDICAL CENTER 1650 WEST COLLEGE STREET GRAPEVINE, TX 76051 DATE: SEPTEMBER 19, 2011 SURVEYOR: RAYMOND L. GOODSON, JR., INC 5445 LA SIERRA, STE 300, LB 17 DALLAS, TX 75231-4138 214-739-8100 r1907 M.00m TX PE REG @F-493', TSPLS REG 1100341-00