HomeMy WebLinkAbout08/15/2022 - F211334-1087691 - LIGHT POLE BASE PIERConcrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PIER, LIGHT POLE BASE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1087691
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:8/2/2022
Time Placed:N/A
N/A
N/A
N/A
N/A
Date Received:N/A
Concrete Supplier:N/A
Submitted By:CONTRACTOR
Plant Number:N/A
Delivery Ticket No.:N/A
N/A
Batch Time:N/A
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:CONTRACTOR
Cured Specification:ASTM C-31
Mix ID:N/A
Break
Type:
Sample Location:M2, MC
PM:PAUL DELANEY
Date Issued:08/15/2022
Specified Strength:3000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
N/A
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
253 8/9/2022 7 2862012.56 2280LABC-1231 8.00 N/A 4.003
254 8/30/2022 28 012.56LABC-1231 8.00 N/A 4.00
255 8/30/2022 28 012.56LABC-1231 8.00 N/A 4.00
Notes:Concrete arrived earlier than scheduled and was placed prior to technician's arrival on-site. No Prepour performed.
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 495136
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 1