Loading...
HomeMy WebLinkAbout04/19/2022 -F211334-1031455 - IN PLACE NUCLEAR DENSITY TEST94.3 24.0 98 120.2 116.9 93.7 24.8 24.2115.8 95.6 25.7 116.4 118.2 93.2 117.1 5 Storm Drain Line-2C, Station 0+50 FG-2.0 1 6 4 Storm Drain Line-2C, Station 0+50 FG-3.0 1 6 116.9 8 Storm Drain Line-2C, Station 2+00 94.1 25.6 93.5 24.5 97 120.0 94.9 26.4 3 Storm Drain Line-2E, Station 0+50 FG 1 6 2 Storm Drain Line-2E, Station 0+50 FG-1.0 1 6 120.0 95.3 1 Storm Drain Line-2E, Station 0+50 FG-2.0 1 6 1 6 10 Storm Drain Line-2C, Station 2+00 FG-1.0 1 6 6 Storm Drain Line-2C, Station 0+50 FG-1.0 1 6 7 Storm Drain Line-2C, Station 0+50 FG 1 6 FG-3.0 1 6 95 9 Storm Drain Line-2C, Station 2+00 FG-2.0 1 6 12 Waterline W-1, Station 5+50 FG-7.0 2 6 11 Storm Drain Line-2C, Station 2+00 FG 94.2 24.3 123.4 118.7 94.8 25.2 98 98 105.2 17.3 96 25.0 97 98 25.9 99 99 98 97 97 Client:Chicken N Pickle Service Date: 04/15/2022 105.8 17.8 97Waterline W-1, Station 5+50 FG-6.0 2 6 124.6 116.6 93.3 Project:Chicken N Pickle Grapevine Project Number: F211334 Off Champagne Boulevard and Merlot Avenue Technician: Sullivan, Maddox Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report 2 104 Armour Road Report Date: 4/19/2022 North Kansas City, MO 64116 Weather: Clear Work Order Number: 1031455 Grapevine, Texas Page Number: 1 of 952 0 4 958 Project Specifications Mat. No. Optimum Moisture (%) Max Dry Weight (pcf) Proctor Report No. Moisture Min. (%) Max. Compaction Min. (%) Max.Material Description/Classification PI Material Information Laboratory Data 100 100215.5 1 22.4 96.4 0 4 109.5 38Dark Brown and Brown Clay with Sand Dark Brown, Light Brown, Gray, and Red Sandy Clay 20 16.2 Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) General Location Area:Utilities Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Field Test Data Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:10071 Manufacturer:Humboldt Model:H5001 EZ 13 125.4 106.2 18.1 Standard Count:(D):3137 (M):339 97 14 Waterline W-1, Station 5+50 Paul Delaney approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Respectfully Submitted, Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Remarks: FG-5.0 2 6 15 Waterline W-1, Station 5+50 FG-4.0 2 6 121.2 104.3 Paul Delaney This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Respectfully Submitted, Remarks: Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:10071 Manufacturer:Humboldt Model:H5001 EZ Standard Count:(D):3137 (M):339 21 Storm Drain Line-2G, Station 0+10 FG 1 6 95.3 23.5 99117.7 100 105.2 17.9 96 96 19 Waterline W-1, Station 5+50 FG 2 6 124.0 17.1 20 Storm Drain Line-2G, Station 0+10 FG-1.0 1 6 18.3 119.5 96.1 24.3 97 18 Waterline W-1, Station 5+50 FG-1.0 2 6 124.0 104.8 17 Waterline W-1, Station 5+50 FG-2.0 2 6 124.1 106.0 16 Waterline W-1, Station 5+50 FG-3.0 2 6 123.8 105.3 17.6 96 Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) General Location Area:Utilities 20 15.5 109.5 0 4 95 Material Description/Classification PI Dark Brown and Brown Clay with Sand 38 2 8 Moisture Min. (%) Max. Compaction Min. (%) Max. 1 2 22.4 96.4 0 4 Mat. No. Proctor Report No. Optimum Moisture (%) Max Dry Weight (pcf) 95 100 100Dark Brown, Light Brown, Gray, and Red Sandy Clay Material Information Laboratory Data Project Specifications Project:Chicken N Pickle Grapevine Project Number: F211334 Off Champagne Boulevard and Merlot Avenue Technician: Sullivan, Maddox Grapevine, Texas Page Number: 2 of 2 Work Order Number: 1031455 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report 104 Armour Road Report Date: 4/19/2022 North Kansas City, MO 64116 Weather: Clear Client:Chicken N Pickle Service Date: 04/15/2022