HomeMy WebLinkAbout06/07/2022 - F211334-1045124,1045124,1045124,1045124Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PAVING: FIRE LANE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1045124-S1
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/10/2022
Time Placed:4:13 AM
5.00
4.0
76
78
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50909379
146.4
Batch Time:3:45:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40U500BG
Break
Type:
Sample Location:25'N & 50'E OF SE CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:06/07/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
45 5/17/2022 7 4313012.56 3430LABC-1231 8.00 N/A 4.003
46 6/7/2022 28 6127012.56 4880LABC-1231 8.00 N/A 4.003
47 6/7/2022 28 5949012.56 4740LABC-1231 8.00 N/A 4.001
48 6/7/2022 28 5919012.56 4710LABC-1231 8.00 N/A 4.003
49 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00
CC:
4780
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485086
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PAVING: FIRE LANE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1045124-S2
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/10/2022
Time Placed:6:08 AM
5.00
3.5
76
77
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50909415
152.2
Batch Time:5:00:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40U500BG
Break
Type:
Sample Location:15'N & 100'E OF SE CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:06/07/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
50 5/17/2022 7 4134012.56 3290LABC-1231 8.00 N/A 4.002
51 6/7/2022 28 5643012.56 4490LABC-1231 8.00 N/A 4.001
52 6/7/2022 28 5744012.56 4570LABC-1231 8.00 N/A 4.002
53 6/7/2022 28 5768012.56 4590LABC-1231 8.00 N/A 4.001
54 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00
CC:
4550
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485087
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 2 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PAVING: FIRE LANE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1045124-S3
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/10/2022
Time Placed:7:32 AM
4.00
3.0
77
79
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50909512
148.8
Batch Time:7:00:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40U500BG
Break
Type:
Sample Location:70'N & 20'E OF SE CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:06/07/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
55 5/17/2022 7 5085012.56 4050LABC-1231 8.00 N/A 4.003
56 6/7/2022 28 6832012.56 5440LABC-1231 8.00 N/A 4.001
57 6/7/2022 28 6974012.56 5550LABC-1231 8.00 N/A 4.003
58 6/7/2022 28 7144012.56 5690LABC-1231 8.00 N/A 4.003
59 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00
CC:
5560
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485088
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 3 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PAVING: FIRE LANE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1045124-S4
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:5/10/2022
Time Placed:9:35 AM
4.00
3.5
77
78
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50909592
148.3
Batch Time:8:00:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40U500BG
Break
Type:
Sample Location:115'N & 25'E OF SE CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:06/07/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
60 5/17/2022 7 3204012.56 2550LABC-1231 8.00 N/A 4.001
61 6/7/2022 28 4446012.56 3540LABC-1231 8.00 N/A 4.003
62 6/7/2022 28 4330012.56 3450LABC-1231 8.00 N/A 4.001
63 6/7/2022 28 4653012.56 3700LABC-1231 8.00 N/A 4.001
64 7/5/2022 56 012.56LABC-1231 8.00 N/A 4.00
CC:
3560
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485089
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 4 of 4