HomeMy WebLinkAbout05/25/2022 - F211334-1053835,1053836 - GROUT PRISMGrout Prism Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:ELEVATOR SHAFT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1053835 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/25/2022 Time Placed:7:30 AM 8.00 N/A 59 70 Date Received:N/A Concrete Supplier:AMERIMIX Submitted By:Thompson, Bryan Plant Number:N/A Delivery Ticket No.:N/A N/A Batch Time:7:25:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: PRISM COMPRESSION TEST RESULTS Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification: Mix ID:N/A Break Type: Sample Location:15 COURSES PM:PAUL DELANEY Date Issued:05/25/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: N/A Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 85 6/1/2022 7 0 N/ALABC-617 N/A 0.00 0.00 86 6/1/2022 7 0 N/ALABC-617 N/A 0.00 0.00 87 6/22/2022 28 0 N/ALABC-617 N/A 0.00 0.00 88 6/22/2022 28 0 N/ALABC-617 N/A 0.00 0.00 TEST RESULTS PENDING Notes:Site Mixed, Pre-Blended CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 486812 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 2 Mortar Cubes Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:ELEVATOR SHAFT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1053836 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/25/2022 Time Placed:9:00 AM N/A N/A 61 65 Date Received:N/A Concrete Supplier:AMERIMIX Submitted By:Thompson, Bryan Plant Number:N/A Delivery Ticket No.:N/A N/A Batch Time:8:55:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CUBE COMPRESSION TEST RESULTS Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:N/A Mix ID:N/A Break Type: Sample Location:15 COURSES PM:PAUL DELANEY Date Issued:05/25/2022 Specified Strength:1800 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: N/A Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 89 6/1/2022 7 04.00LABN/A 2.00 2.00 N/A 90 6/1/2022 7 04.00LABN/A 2.00 2.00 N/A 91 6/1/2022 7 04.00LABN/A 2.00 2.00 N/A 92 6/22/2022 28 04.00LABN/A 2.00 2.00 N/A 93 6/22/2022 28 04.00LABN/A 2.00 2.00 N/A 94 6/22/2022 28 04.00LABN/A 2.00 2.00 N/A TEST RESULTS PENDING Notes:Site Mixed, pre-blended.Type "S" Mortar CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 486814 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 2