Loading...
HomeMy WebLinkAbout06/28/2022 - F211334-1066365 - POST TENSIONINGClient: Project: 1 of 2 TYPE NO.DESIGN -10%10%TOTAL GAUGE LIFT-OFF ELONG. (IN) MIN (IN) MAX (IN)ELONG. (IN)(PSI)(PSI) 1/2 1 9 1/4 8 3/8 10 1/8 8 1/2 8 1/2 -8.11 1/2 2 9 1/4 8 3/8 10 1/8 9 3/8 9 3/8 1.41 1/2 3 9 1/4 8 3/8 10 1/8 8 8 5100 -13.51 1/2 4 9 1/4 8 3/8 10 1/8 7 7/8 7 7/8 5000 -14.81 1/2 5 9 1/4 8 3/8 10 1/8 9 1/8 9 1/8 -1.30 1/2 6 9 1/4 8 3/8 10 1/8 7 3/4 7 3/4 5200 -16.22 1/2 7 9 1/4 8 3/8 10 1/8 8 7/8 8 7/8 -4.00 1/2 8 9 1/4 8 3/8 10 1/8 9 9 -2.70 1/2 9 9 1/4 8 3/8 10 1/8 9 1/8 9 1/8 -1.30 1/2 10 9 1/4 8 3/8 10 1/8 8 8 5000 -13.51 1/2 11 9 1/4 8 3/8 10 1/8 8 1/8 1/4 8 3/8 4900 -9.41 1/2 12 9 1/4 8 3/8 10 1/8 8 1/4 8 1/4 5100 -10.81 1/2 13 9 1/4 8 3/8 10 1/8 9 9 -2.70 1/2 14 9 1/4 8 3/8 10 1/8 8 7/8 8 7/8 -4.00 1/2 15 9 1/4 8 3/8 10 1/8 8 5/8 8 5/8 -6.70 1/2 16 9 1/4 8 3/8 10 1/8 9 1/8 9 1/8 -1.30 1/2 17 4 7/8 4 3/8 5 3/8 5 5 2.56 1/2 18 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 19 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 20 4 7/8 4 3/8 5 3/8 4 1/2 4 1/2 -7.69 1/2 21 4 7/8 4 3/8 5 3/8 4 3/8 4 3/8 -10.15 1/2 22 4 7/8 4 3/8 5 3/8 4 1/2 4 1/2 -7.69 1/2 23 4 7/8 4 3/8 5 3/8 4 7/8 4 7/8 0.10 1/2 24 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 25 4 7/8 4 3/8 5 3/8 4 3/8 4 3/8 -10.15 1/2 26 4 7/8 4 3/8 5 3/8 4 1/2 4 1/2 -7.69 1/2 27 4 7/8 4 3/8 5 3/8 4 1/2 4 1/2 -7.69 1/2 28 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 29 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 30 4 7/8 4 3/8 5 3/8 4 3/8 4 3/8 -10.15 1/2 31 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 32 4 7/8 4 3/8 5 3/8 4 7/8 4 7/8 0.10 1/2 33 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 34 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 35 4 7/8 4 3/8 5 3/8 4 1/2 4 1/2 -7.69 1/2 36 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 37 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 38 4 7/8 4 3/8 5 3/8 4 7/8 4 7/8 0.10 1/2 39 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 40 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 41 4 7/8 4 3/8 5 3/8 4 7/8 4 7/8 0.10 CABLES NOTED WITH A LIFT-OFF PRESSURE HAVE BEEN PULLED TWICE TO GAUGE PRESSURE. FINAL ACCEPTANCE OF CABLE STRESSING SHOULD BE OBTAINED FROM THE DESIGN OR STRUCTURAL ENGINEER, PRIOR TO CUTTING CABLES. Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Post-Tensioning Measurement Report Chicken N Pickle Service Date:6/28/2022 104 Armour Road Report Date:6/28/2022 North Kansas City, Missouri 64116 Weather:Partly Cloudy Work Order Number: 1066365 Chicken N Pickle Grapevine Project Number:F211334 General Location: Benchmark:2" Off Champagne Boulevard and Merlot Avenue Technician:Kopplin, Randy Grapevine, Texas Page Number: Stressing Company:Suncoast Gauge Identification:2002A Ram Identification:2002 Slab-on-Grade 98123M Calibrated PSI:5300 Calibration Date:6/14/2022 Pump Identification: CABLE PULL #1 ELONG. PULL #2 ELONG. LIFT OFF ELONG. DIFFERENCE CommentsDESIGNATION% (+/-) PT Specification:10% STRESSING LOCATION:Foundation B S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-121 S-63 S-63 S-63 S-63 S-63 S-63 S-121 S-121 S-121 S-121 S-63 S-63 Respectfully Submitted, Non-compliant measurements are represented by an asterisk(*) if applicable. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-015(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Paul Delaney This report is in general compliance with one or more of the following technical standards: Post-Tensioning Manual Sixth Edition; Section 20.2.3 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written * * * * * * S-63 S-63 S-63 S-63 *S-63 S-63 S-63 S-63 S-63 S-63 Remarks: * S-63 S-63 S-63 S-63 S-63 S-63 S-63 Page 1 of 2 Client: Project: 2 of 2 TYPE NO.DESIGN -10%10%TOTAL GAUGE LIFT-OFF ELONG. (IN) MIN (IN) MAX (IN)ELONG. (IN)(PSI)(PSI) 1/2 42 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 43 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 44 4 7/8 4 3/8 5 3/8 4 5/8 4 5/8 -5.03 1/2 45 4 7/8 4 3/8 5 3/8 4 7/8 4 7/8 0.10 1/2 46 4 7/8 4 3/8 5 3/8 4 3/4 4 3/4 -2.56 1/2 47 4 7/8 4 3/8 5 3/8 5 1/4 5 1/4 7.69 CABLES NOTED WITH A LIFT-OFF PRESSURE HAVE BEEN PULLED TWICE TO GAUGE PRESSURE. FINAL ACCEPTANCE OF CABLE STRESSING SHOULD BE OBTAINED FROM THE DESIGN OR STRUCTURAL ENGINEER, PRIOR TO CUTTING CABLES. Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Post-Tensioning Measurement Report Chicken N Pickle Service Date:6/28/2022 104 Armour Road Report Date:6/28/2022 North Kansas City, Missouri 64116 Weather:Partly Cloudy Work Order Number: 1066365 Chicken N Pickle Grapevine Project Number:F211334 General Location: Benchmark:2" Off Champagne Boulevard and Merlot Avenue Technician:Kopplin, Randy Grapevine, Texas Page Number: Stressing Company:Suncoast Gauge Identification:2002A Ram Identification:2002 Slab-on-Grade Calibration Date:6/14/2022 PT Specification:10% Pump Identification:98123M Calibrated PSI:5300 % (+/-) S-63 S-63 S-63 STRESSING LOCATION:Foundation B CABLE PULL #1 ELONG. PULL #2 ELONG. LIFT OFF ELONG. DIFFERENCE CommentsDESIGNATION S-63 S-63 S-63 Remarks: Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Non-compliant measurements are represented by an asterisk(*) if applicable. Respectfully Submitted, Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: Post-Tensioning Manual Sixth Edition; Section 20.2.3 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-015(8/2/2016) Paul Delaney Page 2 of 2