Loading...
HomeMy WebLinkAbout04/06/2022 - F211334-1027148Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Remarks: SG 2 6 15 Storm Drain SD-2, Station 7+50 SG 2 6 114.7 94.2 approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Respectfully Submitted, Paul Delaney Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:10071 Manufacturer:Humboldt Model:H5001 EZ 13 114.6 93.6 22.4 Standard Count:(D):3160 (M):340 97 14 Storm Drain SD-2, Station 6+50 21.8 Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) General Location Area:Indoor Court / Utilities Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Field Test Data 21.7 102.3 5 96.4 31Red and Light Brown Clay with Sand Dark Brown and Brown Clay with Sand 382 22.4 957 -2 2 952 Project Specifications Mat. No. Optimum Moisture (%) Max Dry Weight (pcf) Proctor Report No. Moisture Min. (%) Max. Compaction Min. (%) Max.Material Description/Classification PI Material Information Laboratory Data 97 100 1 Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report 2 104 Armour Road Report Date: 4/6/2022 North Kansas City, MO 64116 Weather: Clear Work Order Number: 1027148 Grapevine, Texas Page Number: 1 of Client:Chicken N Pickle Service Date: 04/04/2022 93.2 22.5 97Storm Drain SD-2, Station 0+50 FG-1.0 2 6 114.2 125.0 97.9 Project:Chicken N Pickle Grapevine Project Number: F211334 Off Champagne Boulevard and Merlot Avenue Technician: Sullivan, Maddox 95 28.2 96 95 95 95 96 95 95 92.8 22.1 96 27.7 96 98 9 22' N and 205' E from SW Corner of Building FG-8.0 1 6 12 Storm Drain SD-2, Station 0+25 FG-2.0 2 6 11 10' N and180' E from SW Corner of Building FG-7.0 96.8 28.4 113.3 124.2 97.1 27.916 10 18' N and 210' E from SW Corner of Building FG-7.5 1 6 6 10' N and 195' E from SW Corner of Building FG-9.5 1 6 7 25' N and 230' E from SW Corner of Building FG-9.0 1 6 FG-8.5 1 6 124.3 97.3 27.8 3 32' N and 263' E from SW Corner of Building FG-11.0 1 6 2 5' N and 190' E from SW Corner of Building FG-11.5 1 6 125.1 97.6 1 30' N and 265' E from SW Corner of Building SG 1 6 124.9 125.0 98.1 124.3 5 27' N and 260' E from SW Corner of Building FG-10.0 1 6 4 8' N and 193' E from SW Corner of Building FG-10.5 1 6 124.8 8 15' N and 200' E from SW Corner of Building 97.2 28.6 97.5 28.1 96 98.3 27.0 96 124.6 125.2 98.7 26.8 27.4125.0 98.2 26.9 Work Order Number: 1027148 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report 104 Armour Road Report Date: 4/6/2022 North Kansas City, MO 64116 Weather: Clear Client:Chicken N Pickle Service Date: 04/04/2022 Material Information Laboratory Data Project Specifications Project:Chicken N Pickle Grapevine Project Number: F211334 Off Champagne Boulevard and Merlot Avenue Technician: Sullivan, Maddox Grapevine, Texas Page Number: 2 of 2 Material Description/Classification PI Red and Light Brown Clay with Sand 31 2 2 Moisture Min. (%) Max. Compaction Min. (%) Max. 1 7 21.7 102.3 5 Mat. No. Proctor Report No. Optimum Moisture (%) Max Dry Weight (pcf) 95 97 100Dark Brown and Brown Clay with Sand 38 22.4 96.4 -2 2 95 General Location Area:Utilities Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) 16 Storm Drain SD-2A, Station 6+00 SG 2 6 113.9 93.6 21.7 97 97 18 Storm Drain SD-2A, Station 6+50 FG-4.0 2 6 113.0 92.6 17 Storm Drain SD-2A, Station 7+00 SG 2 6 113.5 93.5 19 Storm Drain SD-2A, Station 7+50 FG-4.0 2 6 114.6 21.4 20 Storm Drain SD-2A, Station 6+25 FG-3.0 2 6 22.0 115.5 94.2 22.6 98 94.0 21.9 98 96 93.8 22.3 97 115.7 94.4 22.6 98 114.7 114.7 21 Storm Drain SD-2A, Station 7+25 FG-3.0 2 6 22 Storm Drain SD-2A, Station 6+75 FG-2.0 2 6 23 Storm Drain SD-2A, Station 7+75 FG-2.0 2 6 93.9 22.1 97 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:10071 Manufacturer:Humboldt Model:H5001 EZ Standard Count:(D):3160 (M):340 Remarks: Respectfully Submitted, Paul Delaney This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering