Loading...
HomeMy WebLinkAbout06/15/2022 - F211334-1060170,1060170,1060170,1060170Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRST FOUR SOUTH ROWS OF THE SE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1060170-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/14/2022 Time Placed:2:12 AM 4.00 3.6 83 92 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Russell, Nicholas Plant Number:506 Delivery Ticket No.:40919346 144.8 Batch Time:1:45:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40U500BG Break Type: Sample Location:SOUTH ENTRANCE AT MERLOT AVE. PM:PAUL DELANEY Date Issued:06/15/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 130 6/21/2022 7 012.56LABC-1231 8.00 N/A 4.00 131 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 132 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 133 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 134 8/9/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489062 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRST FOUR SOUTH ROWS OF THE SE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1060170-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/14/2022 Time Placed:4:11 AM 5.00 4.3 80 89 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Russell, Nicholas Plant Number:506 Delivery Ticket No.:50919407 142.4 Batch Time:3:50:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:15 FT N 26 FT E OF THE FIRST SW ISLAND PM:PAUL DELANEY Date Issued:06/15/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 135 6/21/2022 7 012.56LABC-1231 8.00 N/A 4.00 136 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 137 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 138 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 139 8/9/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489063 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING FIRST FOUR SOUTH ROWS OF THE SE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1060170-S3 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/14/2022 Time Placed:6:14 AM 5.00 4.8 78 92 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Russell, Nicholas Plant Number:506 Delivery Ticket No.:40919459 143.6 Batch Time:5:30:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:12 FT S AND 15 FT E OF THE FOURTH SW ISLAND PM:PAUL DELANEY Date Issued:06/15/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 140 6/21/2022 7 012.56LABC-1231 8.00 N/A 4.00 141 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 142 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 143 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 144 8/9/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489064 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 3 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRST FOUR SOUTH ROWS OF THE SE PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1060170-S4 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:6/14/2022 Time Placed:8:38 AM 6.00 4.0 80 88 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Russell, Nicholas Plant Number:506 Delivery Ticket No.:50919556 143.2 Batch Time:8:00:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:5 FT S AND 5 FT W OF THE THIRD SE ISLAND PM:PAUL DELANEY Date Issued:06/15/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 145 6/21/2022 7 012.56LABC-1231 8.00 N/A 4.00 146 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 147 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 148 7/12/2022 28 012.56LABC-1231 8.00 N/A 4.00 149 8/9/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 489065 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 4 of 4