HomeMy WebLinkAbout04/25/2022 - F211334-1036318,1036331,1036331,1036331Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:MANHOLE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1036318
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:4/20/2022
Time Placed:3:05 PM
1.00
3.0
81
84
Date Received:N/A
Concrete Supplier:REDI-MIX
Submitted By:Sullivan, Maddox
Plant Number:259
Delivery Ticket No.:494802
155.7
Batch Time:2:15:00 PM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:10M11504
Break
Type:
Sample Location:STATION 5+05.04
PM:PAUL DELANEY
Date Issued:04/25/2022
Specified Strength:3600
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Clear
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
11 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00
12 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
13 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
14 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
15 4/23/2022 3 5431012.56 4320LABC-1231 8.00 N/A 4.003
Notes:Concrete placed tested below specified slump. Contractor and Site Superintendent notified.
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482959
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:SLAB-ON-GRADE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1036331-S1
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:4/20/2022
Time Placed:5:45 AM
3.00
1.0
62
65
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50904144
159.6
Batch Time:4:51:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40V400BG
Break
Type:
Sample Location:15'N & 10'E OF SW CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:04/25/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Light Drizzle
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
16 4/23/2022 3 5464012.56 4350LABC-1231 8.00 N/A 4.002
17 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00
18 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
19 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
20 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump.
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482978
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 2 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:SLAB-ON-GRADE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1036331-S2
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:4/20/2022
Time Placed:9:32 AM
3.00
1.2
69
73
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:50904351
158.6
Batch Time:8:58:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40V400BG
Break
Type:
Sample Location:75'N & 25'E OF SW CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:04/25/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Light Drizzle
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
21 4/23/2022 3 4719012.56 3760LABC-1231 8.00 N/A 4.002
22 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00
23 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
24 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
25 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump.
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482979
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 3 of 4
Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:SLAB-ON-GRADE
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1036331-S3
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:4/20/2022
Time Placed:2:50 PM
4.50
1.0
76
79
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Sullivan, Maddox
Plant Number:506
Delivery Ticket No.:N/A
154.8
Batch Time:N/A
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:40V400BG
Break
Type:
Sample Location:175'N & 10'W OF SE CORNER OF BUILDING
PM:PAUL DELANEY
Date Issued:04/25/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
Light Drizzle
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
26 4/23/2022 3 3264012.56 2600LABC-1231 8.00 N/A 4.002
27 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00
28 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
29 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
30 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00
Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump.
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482980
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 4 of 4