HomeMy WebLinkAbout04/25/2022 - F211334-1036318,1036331,1036331,1036331Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:MANHOLE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1036318 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:4/20/2022 Time Placed:3:05 PM 1.00 3.0 81 84 Date Received:N/A Concrete Supplier:REDI-MIX Submitted By:Sullivan, Maddox Plant Number:259 Delivery Ticket No.:494802 155.7 Batch Time:2:15:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:10M11504 Break Type: Sample Location:STATION 5+05.04 PM:PAUL DELANEY Date Issued:04/25/2022 Specified Strength:3600 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 11 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00 12 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 13 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 14 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 15 4/23/2022 3 5431012.56 4320LABC-1231 8.00 N/A 4.003 Notes:Concrete placed tested below specified slump. Contractor and Site Superintendent notified. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482959 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-GRADE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1036331-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:4/20/2022 Time Placed:5:45 AM 3.00 1.0 62 65 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50904144 159.6 Batch Time:4:51:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40V400BG Break Type: Sample Location:15'N & 10'E OF SW CORNER OF BUILDING PM:PAUL DELANEY Date Issued:04/25/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Light Drizzle Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 16 4/23/2022 3 5464012.56 4350LABC-1231 8.00 N/A 4.002 17 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00 18 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 19 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 20 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482978 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-GRADE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1036331-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:4/20/2022 Time Placed:9:32 AM 3.00 1.2 69 73 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50904351 158.6 Batch Time:8:58:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40V400BG Break Type: Sample Location:75'N & 25'E OF SW CORNER OF BUILDING PM:PAUL DELANEY Date Issued:04/25/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Light Drizzle Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 21 4/23/2022 3 4719012.56 3760LABC-1231 8.00 N/A 4.002 22 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00 23 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 24 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 25 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482979 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 3 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-GRADE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1036331-S3 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:4/20/2022 Time Placed:2:50 PM 4.50 1.0 76 79 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:N/A 154.8 Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40V400BG Break Type: Sample Location:175'N & 10'W OF SE CORNER OF BUILDING PM:PAUL DELANEY Date Issued:04/25/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Light Drizzle Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 26 4/23/2022 3 3264012.56 2600LABC-1231 8.00 N/A 4.002 27 4/27/2022 7 012.56LABC-1231 8.00 N/A 4.00 28 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 29 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 30 5/18/2022 28 012.56LABC-1231 8.00 N/A 4.00 Notes:Multiple Trucks rejected by contactor during concrete placement for excessive time from batch,or excessive slump. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 482980 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 4 of 4