Loading...
HomeMy WebLinkAbout05/11/2022 - F211334-1045124,1045124,1045124,1045124Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRE LANE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1045124-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/10/2022 Time Placed:4:13 AM 5.00 4.0 76 78 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50909379 146.4 Batch Time:3:45:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40U500BG Break Type: Sample Location:25'N & 50'E OF SE CORNER OF BUILDING PM:PAUL DELANEY Date Issued:05/11/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 45 5/17/2022 7 012.56LABC-1231 8.00 N/A 4.00 46 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 47 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 48 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 49 7/5/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485086 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRE LANE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1045124-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/10/2022 Time Placed:6:08 AM 5.00 3.5 76 77 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50909415 152.2 Batch Time:5:00:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40U500BG Break Type: Sample Location:15'N & 100'E OF SE CORNER OF BUILDING PM:PAUL DELANEY Date Issued:05/11/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 50 5/17/2022 7 012.56LABC-1231 8.00 N/A 4.00 51 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 52 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 53 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 54 7/5/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485087 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRE LANE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1045124-S3 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/10/2022 Time Placed:7:32 AM 4.00 3.0 77 79 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50909512 148.8 Batch Time:7:00:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40U500BG Break Type: Sample Location:70'N & 20'E OF SE CORNER OF BUILDING PM:PAUL DELANEY Date Issued:05/11/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 55 5/17/2022 7 012.56LABC-1231 8.00 N/A 4.00 56 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 57 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 58 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 59 7/5/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485088 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 3 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRE LANE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1045124-S4 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:5/10/2022 Time Placed:9:35 AM 4.00 3.5 77 78 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Sullivan, Maddox Plant Number:506 Delivery Ticket No.:50909592 148.3 Batch Time:8:00:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40U500BG Break Type: Sample Location:115'N & 25'E OF SE CORNER OF BUILDING PM:PAUL DELANEY Date Issued:05/11/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 60 5/17/2022 7 012.56LABC-1231 8.00 N/A 4.00 61 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 62 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 63 6/7/2022 28 012.56LABC-1231 8.00 N/A 4.00 64 7/5/2022 56 012.56LABC-1231 8.00 N/A 4.00 TEST RESULTS PENDING CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 485089 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 4 of 4