HomeMy WebLinkAbout74-34790-22-23denhmacEwEllerb�ee WaICAL IcE aku Inc. CONSTRUCTION MATERIALS TESTING SERVICES REPORT NO.: 74-34790-22-23denhmac REPORT OF: In Place Density of H.M.A.C. CLIENT: Wright Construction Company, Inc PROJECT: Wright Construction Office TEST METHOD: ASTM D-2950 Nuclear Method -Direct Transmission Avg. of 3 Tests at Same Location DATE: 04/22/2022 TECHNICIAN: Joshua Guiles HMAC: Type D REQUIRED: No specifications provided GT: 2.509 or 156.6 P.C.F. GAUGE: SER#36794 VALUE OF NO: 1789DD — 710M DEPTH: Backscatter NO. PCF/DRY AVG. DENS % DENS LOCATIONS 1A 144.3 1 B 148.0 1C 145.2 145.8 93.1 Waterline tie in on South Scribner St 2A 143.8 2B 147.1 2C 143.3 144.7 92.4 Waterline tie in on South Scribner St N.C.T.C.O.G. Item 302.9.6.7 states that each course after Final Compaction shall have a density of not less than 95% of the Density developed in the Laboratory Test Method found in Bulletin C-14. C-14 refers you to Texas Method 207-F for the Determination of Density of Compacted Bituminous Mixtures. These specimens as stated in 207-F can be lab -molded, cores, slabs or direct transmission nuclear density tests as stated in ASTM D-2950 performed on Bituminous pavements. EWI has chosen to perform ASTM D- 2950 tests on the Wright Construction Office Project in question and has utilized the Theo Sp.G. Test as shown on the projects HMAC Mix Design to determine In -Place Density of said pavement. .41 � Hector Martinez General Manager Cc.. Wright — Ashley Wright awright@wrightconst.com 461rence, Jr., N.E. Texas Firm No. F-4610 4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117 Office 817-759-9999 • Fax 817-759-1888 Page 1 of 1