HomeMy WebLinkAbout74-34790-22-26dennoEllerbee-Walczak Inc.
GEOTECHNICAL ENGINEERING &
CONSTRUCTION MATERIALS TESTING SERVICES
IN PLACE DENSITY TESTS USING NUCLEAR GAUGE
REPORT NO.:
74-34790-22-26den
CLIENT:
Wright Construction Co, Inc
DATE:
8/11/2022
PROJECT:
Wright Construction Office
TECHNICIAN:
TJ Luke
TEST METHOD:
ASTM D-6938
GAUGE:
TROX Ser#28767
VALUE OF NO.:
1772DD-622M
WEATHER:
Sunny
PROJECT MANAGER: None
TEST
RESULT
PROC
PCF
PERCENT
PERCENT
OPT. PROJ.
NO.
DRY
COMPACT
MOIST
MOIST SPEC
1
Pass
29347
108.2
96.0
16.8
1.9
2
Pass
29347
109.1
96.8
16.2
1.3
3
Pass
29347
109.4
97.0
16.4
1.5
4
Pass
29347
111.1
98.5
15.2
0.3
PROCTORS USED:
P-29347 112.7 PCF @ 14.9% - Reddish brown sandy clay
SPECS USED:
1 Moisture at or above optimum
PROBE DEPTH: 6in
REMARKS: Test locations given by foreman.
TEST TYPES: (H) Street Fill
DEPTH ELEVATION: (AEG) At Existing Grade
Hector Martinez, General Manager
TEST LOCATIONS
TYPE
DEPTH RETEST
ELEV.
1 H Parking Lot West of Building - Southeast AEG
1 H Parking Lot West of Building - South AEG
1 H Parking Lot West of Building - Southwest AEG
1 H Parking Lot West of Building - North AEG
Density 95.0% min
Distribution:
Wright Construction Co, Inc - Ashley Wright
aan�ce, Jr. P.E.
Texas Firm No. F-4610
4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117
Office 817-759-9999 • Fax 817-759-1888
74-34790-22-26den Page 1 of 1