Loading...
HomeMy WebLinkAboutC-45734Ellerbee-Walczak Inc. Eff GEOTECHNICAL ENGINEERING & CONSTRUCTION MATERIALS TESTING SERVICES COMPRESSIVE STRENGTH (4x8 inch. Cylinder) Client: Wright Construction Co, Inc Report #: C-45734 Project: Wright Construction Office Technician: Issac Gutierrez Supplier: Cowtown Redi Mix Placement: 3/28/2022 Strength": 3000 PSI ID # 1 2 3 4 Age Test Load Frac. Strength Date (lbs.) Type (PSI) 7 4/4 46295 2 3684 28 4/25 73520 5 5851 28 4/25 69825 3 5556 28 4/25 58390 3 4647 Location: Piers 11-13 Remarks: * Specified Strength Requirement given by: Concrete delivery ticket Pass Design ID: 250.01 Fail Ticket: 1272604 Truck: 1075 Pass Batch Time: 10:17 AM Pass Sample Time: 10:30 AM Pass Ambient Temp: 69 Material Temp: 75 Air %: 1.9 Unit Weight (pcf): 144.9 Consolidation: Rodding Slump (Inches): 5.5 Specifications: Field and laboratory tests by EWI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 ,.&W Hector Martinez, General Manager Distribution: Wright Construction Co, Inc - Ashley Wright e, Jr. Pirm No. F-4610 4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117 Office 817-759-9999 • Fax 817-759-1888 C-45734 Page 1 of 1