Loading...
HomeMy WebLinkAbout74-34790-22-03denEllerbee-Walczak Inc. off GEOTECHNICAL ENGINEERING & CONSTRUCTION MATERIALS TESTING SERVICES IN PLACE DENSITY TESTS USING NUCLEAR GAUGE REPORT NO.: 74-34790-22-03den CLIENT: Wright Construction Co, Inc DATE: 3/1/2022 PROJECT: Wright Construction Office TECHNICIAN: Issac Gutierrez TEST METHOD: ASTM D-6938 GAUGE: TROX Ser#25193 VALUE OF NO.: 1715DD-620M WEATHER: Sunny PROJECT MANAGER: Teddy Cummings TEST RESULT PROC PCF PERCENT PERCENT OPT. PROJ. TEST LOCATIONS NO. DRY COMPACT MOIST MOIST SPEC TYPE 1 Pass 29347 110.2 98.0 19.1 4.2 1 J Northwest Corner 2 Pass 29347 110.0 98.0 19.3 4.4 1 J Southwest Corner 3 Pass 29347 109.7 97.3 19.8 4.9 1 J Southeast Corner 4 Pass 29347 110.6 98.1 19.0 4.1 1 J Northeast Corner PROCTORS USED: P-29347 112.7 PCF @ 14.9% - Reddish brown sandy clay SPECS USED: 1 Moisture 2.0% above optimum Density 95.0% min PROBE DEPTH: 6in TEST TYPES: (J) Building Fill DEPTH ELEVATION: (LIFT) Lift X'/O� Hector Martinez, General Manager Distribution: Wright Construction Co, Inc - Ashley Wright Prc, exas Fim No. F-46 DEPTH RETEST ELEV. 2nd LIFT 2nd LIFT 2nd LIFT 2nd LIFT 4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117 Office 817-759-9999 • Fax 817-759-1888 74-34790-22-03den Page 1 of 1