HomeMy WebLinkAbout74-34790-22-17rsiEllerbee-Walczak Inc. off GEOTECHNICAL ENGINEERING & CONSTRUCTION MATERIALS TESTING SERVICES REPORT NO.: 74-34790-22-17rsi REPORT OF: Reinforcing Steel Inspection CLIENT: Wright Construction Company, Inc PROJECT: Wright Construction Office DATE: 4/8/2022 INSPECTOR: Jason Fruge On this date, reinforcing steel was inspected for the elevator pit floor. The following Reinforcing Items were inspected. Summary of Inspection Items Inspected Correct Incorrect Items Inspected Placing Drawings Approved x Dowel Bars in Place Bar Size & Grade x Lapped Splices Reinforcing Steel Clean x I lColumn Ties Properly Tied & Spaced Forms Clean x Proper Clearance from Forms Number of Bars x Stirrup Spacing/Type Bar Length & Shape x I lWelded Splices Proper Bar Placement x Mechanical Splices Properly Tied x Proper Cover Proper Bar Supports x Plans or Cut Sheets used for Inspection: S1.2 Detail #3 Plan Sheet Approval Date: 10/12/2021 Discrepancies: None iAW-1 Hector Martinez General Manager Cc: Wright — Ashley Wright awright@wrightconst.com T. A dLce, E. Texas Firm No. F-4610 Correct Incorrect x x x 4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117 Office 817-759-9999 • Fax 817-759-1888