HomeMy WebLinkAbout74-34790-22-17rsiEllerbee-Walczak Inc.
off GEOTECHNICAL ENGINEERING &
CONSTRUCTION MATERIALS TESTING SERVICES
REPORT NO.:
74-34790-22-17rsi
REPORT OF:
Reinforcing Steel Inspection
CLIENT:
Wright Construction Company, Inc
PROJECT:
Wright Construction Office
DATE:
4/8/2022
INSPECTOR:
Jason Fruge
On this date, reinforcing steel was inspected for the elevator pit floor.
The following Reinforcing Items were inspected.
Summary of Inspection
Items Inspected
Correct
Incorrect Items Inspected
Placing Drawings Approved
x
Dowel Bars in Place
Bar Size & Grade
x
Lapped Splices
Reinforcing Steel Clean
x
I lColumn Ties Properly Tied & Spaced
Forms Clean
x
Proper Clearance from Forms
Number of Bars
x
Stirrup Spacing/Type
Bar Length & Shape
x
I lWelded Splices
Proper Bar Placement
x
Mechanical Splices
Properly Tied
x
Proper Cover
Proper Bar Supports
x
Plans or Cut Sheets used for Inspection: S1.2 Detail #3
Plan Sheet Approval Date: 10/12/2021
Discrepancies: None
iAW-1
Hector Martinez
General Manager
Cc: Wright — Ashley Wright awright@wrightconst.com
T. A dLce, E.
Texas Firm No. F-4610
Correct Incorrect
x
x
x
4501 Broadway Ave. • P.O. Box 14809 • Haltom City, Texas 76117
Office 817-759-9999 • Fax 817-759-1888