Loading...
HomeMy WebLinkAbout10/10/2022 - F211334-1119080,1119080 -Core Compression TestCore Compression Test Report5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:SAMPLED PATCH PAVING ON MERLOT AVE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1119080-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:10/5/2022 Time Placed:N/A N/A N/A N/A N/A Date Received:N/A Concrete Supplier:N/A Submitted By:Martinez, Austin Plant Number:N/A Delivery Ticket No.:N/A N/A Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CORE COMPRESSION TEST RESULTS (CORRECTED PSI) (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:CONTRACTOR Cured Specification:ASTM C-31 Mix ID:N/A Break Type: Sample Location:NORTH BOUND LANE REPLACEMENT PM:PAUL DELANEY Date Issued:10/10/2022 Specified Strength:3600 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: N/A Initial Curing Method:Other, See Notes Below Final Curing Method:Other, See Notes Below 295 10/10/2022 5 3284012.25 2630LABC-1231 6.90 N/A 3.95 296 10/10/2022 5 3811012.25 2990LABC-1231 6.00 N/A 3.95 297 10/10/2022 5 3711012.25 2950LABC-1231 6.60 N/A 3.95 Notes:Cores cut in field, cured 5 days as required per ACI requirements. Core Compressive Strength Test results are less than City Specification of 3,600 psi. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 503486 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 2 Core Compression Test Report5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:S FOOTING FOR ENTRANCE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1119080-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:10/5/2022 Time Placed:N/A N/A N/A N/A N/A Date Received:N/A Concrete Supplier:N/A Submitted By:Martinez, Austin Plant Number:N/A Delivery Ticket No.:N/A N/A Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CORE COMPRESSION TEST RESULTS (CORRECTED PSI) (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:CONTRACTOR Cured Specification:ASTM C-31 Mix ID:N/A Break Type: Sample Location:SOUTH SIDE FOOTING PM:PAUL DELANEY Date Issued:10/10/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: N/A Initial Curing Method:Other, See Notes Below Final Curing Method:Other, See Notes Below 298 10/10/2022 5 7147012.25 5590LABC-1231 5.85 N/A 3.95 299 10/10/2022 5 6883012.25 4930LABC-1231 4.05 N/A 3.95 300 10/10/2022 5 7355012.25 5410LABC-1231 4.45 N/A 3.95 Notes:Cores cut in field, cured 5 days as required per ACI requirements. Core Compressive Strength Test results exceed project footing specified strength of 3000 psi. CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 503487 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 2