HomeMy WebLinkAbout10-14-2022 F211334-11255145058 Brush Creek Road
Fort Worth, Texas 76119
Geotechnical I Construction Materials I Environmental
www.alphatesting.com
TBPE Firm No. 813
Our test results and reports are for the exclusive use of the client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with
express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not indicative of the qualities of apparently identical or similar specimens.
October 14, 2022
Chicken N Pickle
104 Armour Road
North Kansas City, MO 64116
Attention: Mr. Alex Stehl
Re: Field Inspection of Structural Steel
Chicken N Pickle Grapevine
Grapevine, Texas
ALPHA Report No. F211334-1125514
Alpha Testing arrived on site to perform a Visual Structural Steel Inspection for the above referenced
project. Results of the inspection are as follows:
I Host Shack H1-H7/HA-HC
A HSS 12” x 4” Header to column welded connections consist of excessive undercut,
lack-of-fusion and excessive convexity. Non-compliant
B HSS 4” x 4” Parapet welded connections all consist of lack of fusion, excessive
undercut, porosity and welds covered, thus not able to visually inspect. Non-
compliant (Reference details listed above for weld details)
C Beam to Column and Parapet column to beam consist of torch cut holes. Non-
compliant
NOTE: Noted torch cut holes and Top Parapet HSS 4” x 4”connections at HA-H3, HC-H4
have excessive gaps and not able to weld all around as required.
Please see attached pictures for representative views of field conditions.
*Discrepancies, if any, are noted above in bold .
INSPECTOR:
Eric Joy
CWI#13081471
We are pleased to be of service on this project and if you have any questions, please contact our office.
Sincerely yours,
ALPHA TESTING, LLC
Paul Delaney
Project Manager