Loading...
HomeMy WebLinkAbout10-27-2022F211334-1116721,1116721Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALKS ALONG MERLOT AVE N OF ENTRANCE AND EASTSIDE MAIN BAR WALKWAY Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1116721-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:9/29/2022 Time Placed:6:10 AM 6.00 3.5 67 81 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Manuvo, Joseph Plant Number:506 Delivery Ticket No.:50950082 145.2 Batch Time:5:02:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:35U500BG Break Type: Sample Location:SIDEWALK NORTH OF MERLOT AVE SOUTH ENTRY. PM:PAUL DELANEY Date Issued:10/27/2022 Specified Strength:3500 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 280 10/6/2022 7 5494012.56 4370LABC-1231 8.00 N/A 4.001 281 10/27/2022 28 6260012.56 4980LABC-1231 8.00 N/A 4.002 282 10/27/2022 28 6140012.56 4890LABC-1231 8.00 N/A 4.002 283 10/27/2022 28 6542012.56 5210LABC-1231 8.00 N/A 4.002 284 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 5030 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 502159 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 2 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:HOST SHACK SLAB ON GRADE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1116721-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:9/29/2022 Time Placed:8:30 AM 6.75 1.0 67 79 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Manuvo, Joseph Plant Number:506 Delivery Ticket No.:50950193 147.6 Batch Time:7:21:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-173) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:40V400BG Break Type: Sample Location:SOUTH EAST CORNER OF SLAB PM:PAUL DELANEY Date Issued:10/27/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 275 10/6/2022 7 5452012.56 4340LABC-1231 8.00 N/A 4.001 276 10/27/2022 28 6502012.56 5180LABC-1231 8.00 N/A 4.001 277 10/27/2022 28 6534012.56 5200LABC-1231 8.00 N/A 4.001 278 10/27/2022 28 6386012.56 5080LABC-1231 8.00 N/A 4.003 279 HOLD HOLD 012.56LABC-1231 8.00 N/A 4.00 CC: 5150 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 502160 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 2