Loading...
HomeMy WebLinkAbout11/11/2022 - F211334-1108863Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING : SE CORNER OF PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1108863-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:9/16/2022 Time Placed:9:28 AM 3.5 5 80 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Willis, Mckile Plant Number:508 Delivery Ticket No.:50945619 141 Batch Time:8:43:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:50V500BG Break Type: Sample Location:36'N BY 21'E OF SE CORNER OF PARKING AREA PM:PAUL DELANEY Date Issued:11/11/2022 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: N/A Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 270 9/23/2022 7 3995012.56 3180LABC-1231 8.00 N/A 4.001 271 10/14/2022 28 4648012.56 3700LABC-1231 8.00 N/A 4.003 272 10/14/2022 28 4876012.56 3880LABC-1231 8.00 N/A 4.002 273 10/14/2022 28 4773012.56 3800LABC-1231 8.00 N/A 4.003 274 11/11/2022 56 5493012.56 4370LABC-1231 8.00 N/A 4.002 CC: 3790 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 500470 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 1