HomeMy WebLinkAboutCU2022-57CU22-57.1.docx 1
Email a PDF of the revised plans by December 26, 2022 at 12:00 p.m. to emarohnic@grapevinetexas.gov,
atriplett@grapevinetexas.gov and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x
17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval.
PROJECT DESCRIPTION: CU22-57 ServPro – submitted by Alliance Architects for property located at 2045
Grayson Drive and platted as Block 1, Lot 1, ServPro Addition. The applicant is requesting a conditional
use permit to amend the previously approved site plan CU22-10 (Ord.2022-014). This request is
specifically to allow changes to change building materials, add doors and stairs for exiting purposes, add
venting and increase and decrease building height. The property is currently zoned “LI”, Light Industrial
District and owned by ServPro.
PLANNING SERVICES
All Plan Set Sheets:
1. Add the purpose statement below to all sheets in the plan set:
a. The purpose of conditional use permit CU22-57, is to amend previously approved site
plan CU22-10 (Ord. 2022-014) to change building materials, add doors and stairs for
exiting purposes, add venting and increase and decrease building height.
2. Submit the following updated sheets (contact Claymoore Engineering for new stamped and
sealed plans):
a. Site Plan
b. Dimensional Control Site Plan
c. Landscape Plan
d. Landscape details
Exterior Building Elevations Sheet # A5-01r:
1. Correct the case number in the signature block to CU22-57.
2. Correct Title Block on sheet A5-01r to say “Building Elevations.”
PUBLIC WORKS
Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil
Engineer at 817.410.3136 for the following comments:
• Civil plans and Architectural site plans are not consistent. Provide new Civils (grading/ paving) to
Engineering that are consistent with the plans that were submitted to Planning Services on
12.5.22.
BUILDING SERVICES
Contact Larry Gray – Acting Building Official at 817.410.3163 or lgray@grapevinetexas.gov to
discuss the following:
CU22-57 DECEMBER 16, 2022
SERVPRO 2045 GRAYSON DRIVE
BLOCK 1, LOT 1, SERVPRO ADDITION
CU22-57.1.docx 2
• Structural engineered drawings for the sky light addition to the roof.
• Construction documents required for permit issuance.
• M.E.P. engineering is required in accord with State law.
FIRE MARSHALL
Contact Bryan Parker - Fire Marshal at 817.410.4420 or bparker@grapevinetexas.gov for the
following comments:
• No comments.
PARKS
Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or
knelson@grapevinetexas.gov to discuss the following:
• No comments.
____________________________________________________________________
Email a PDF of the revised plans by December 26, 2022, at 12:00 p.m. to emarohnic@grapevinetexas.gov,
atriplett@grapevinetexas.gov, and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x
17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval.
Please direct all questions to Erica Marohnic at (8l7) 410-3155 or Albert Triplett at (817) 410-3155.
CU22-57.1a.docx 1
Email a PDF of the revised plans by December 26, 2022 at 12:00 p.m. to emarohnic@grapevinetexas.gov,
atriplett@grapevinetexas.gov and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x
17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval.
PROJECT DESCRIPTION: CU22-57 ServPro – submitted by Alliance Architects for property located at 2045
Grayson Drive and platted as Block 1, Lot 1, ServPro Addition. The applicant is requesting a conditional
use permit to amend the previously approved site plan CU22-10 (Ord.2022-014). This request is
specifically to allow changes to change building materials, add doors and stairs for exiting purposes, add
venting and increase and decrease building height. The property is currently zoned “LI”, Light Industrial
District and owned by ServPro.
PLANNING SERVICES
All Plan Set Sheets:
1. Add the purpose statement below to all sheets in the plan set:
a. The purpose of conditional use permit CU22-57, is to amend previously approved site
plan CU22-10 (Ord. 2022-014) to change building materials, add doors and stairs for
exiting purposes, add venting and increase and decrease building height.
2. Submit the following updated sheets (contact Claymoore Engineering for new stamped and
sealed plans):
a. Site Plan
b. Dimensional Control Site Plan
c. Landscape Plan
d. Landscape details
Exterior Building Elevations Sheet # A5-01r:
1. Correct the case number in the signature block to CU22-57.
2. Correct Title Block on sheet A5-01r to say “Building Elevations.”
PUBLIC WORKS
Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil
Engineer at 817.410.3136 for the following comments:
• Civil plans and Architectural site plans are not consistent. Provide new Civils (grading/ paving) to
Engineering that are consistent with the plans that were submitted to Planning Services on
12.5.22.
BUILDING SERVICES
Contact Larry Gray – Acting Building Official at 817.410.3163 or lgray@grapevinetexas.gov to
discuss the following:
CU22-57 DECEMBER 16, 2022
SERVPRO 2045 GRAYSON DRIVE
BLOCK 1, LOT 1, SERVPRO ADDITION
CU22-57.1a.docx 2
• Structural engineered drawings for the sky light addition to the roof.
• Construction documents required for permit issuance.
• M.E.P. engineering is required in accord with State law.
FIRE MARSHALL
Contact Bryan Parker - Fire Marshal at 817.410.4420 or bparker@grapevinetexas.gov for the
following comments:
• No comments.
PARKS
Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or
knelson@grapevinetexas.gov to discuss the following:
• No comments.
____________________________________________________________________
Email a PDF of the revised plans by December 26, 2022, at 12:00 p.m. to emarohnic@grapevinetexas.gov,
atriplett@grapevinetexas.gov, and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x
17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval.
Please direct all questions to Erica Marohnic at (8l7) 410-3155 or Albert Triplett at (817) 410-3155.
CHARTER
HOSPITAL
ADDN
7113
GRAYSON
/
1
2
1
ADDN
16125
18.201 @
2.057 AC
3.21 @
1.47 @
1
1
1
(ST
A
T
E
H
W
Y
2
6
)
SO
U
T
H
W
E
S
T
G
R
A
P
E
V
I
N
E
P
K
W
Y
GRAY
S
O
N
D
R
.
TR 1
1
1
25
1
24
23
2
22
SOUTHWE
S
T
GRAPEVIN
E
COMMERC
I
A
L
PARK
39727
ST MORITZ
37140J
10.6373 @
4R2
14.407 @
3R
GRAYSON
SQUARE
APTS
PHASE II
16125
LI
CC
PID
R-MF-2
R-7.5
CC
G
r
a
y
s
o
n
SH
1
2
1
William D Tate
CU22-57 ServPro
0 100 200 300 400
Feet
²
Date Prepared: 1/27/2022 This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources were
used to gather this information. Every effort was made to ensure the accuracy of this data, however, no guarantee is
given or implied as to the accuracy of said data.
SUBJECT PROPERTY
Agenda Item # III. A.
CU22-57.4 1
TO: SITE PLAN REVIEW COMMITTEE MEMBERS
FROM: ALBERT L. TRIPLETT, JR, PLANNER II
DATE: JANUARY 5, 2023
SUBJECT: CONDITIONAL USE REQUEST CU22-57; SERVPRO
RECOMMENDATION
Staff recommends the Site Plan Review Committee (SPRC) consider proposed changes to
approved site plan of conditional use request CU22-10 (Ord. 2022-014). This request is
specifically to allow building material changes, add doors and stairs for exiting purposes,
add louvers for venting, and increase and decrease building height. This property is
currently zoned “LI”, Light Industrial District, and is owned by ServPro.
REQUEST
The property owner, ServPro, intends to construct a one -story, 35-foot tall, 31,324 sq. ft.
building for office and warehouse purposes. ServPro’s use is classified as a construction
trade office in the City of Grapevine’s Zoning Ordinance, a use that is permitted by right in
the “LI” Light Industrial District. On February 15, 2022, City Council approved conditional
use request CU22-10 (Ord. 2022-014) to allow outdoor storage in conjunction with a
31,324-square-foot building.
The following changes are proposed to the building’s elevations as the design has evolved
and to meet building and fire code requirements:
1. Materials: revision from concrete tilt-wall construction to a split-faced concrete
masonry block along the majority of the west elevation and approximately half of the
northern elevation. Materials remain at 97% to 100% masonry concrete.
2. Building Height:
West Elevation – height increased from 35 feet to 37.5 feet.
South Elevation – height decreased from 35 feet to 34 feet, 7 ½ inches.
East Elevation – height increased from 38.5 feet to 39.5 feet.
North Elevation – height increased from 36.5 feet to 37 feet, 4 inches.
3. Doors:
W est Elevation – added three egress doors with steel staircases.
South Elevation – added two egress doors with steel staircases.
East Elevation – added one egress door with a steel staircase, converted window to
Agenda Item # III. A.
CU22-57.4 2
an overhead glass door, and added a ramp to two previously shown overhead doors
North Elevation – added two egress doors with steel staircases
4. Several louvers of various sizes have been added to the west, south, and east
elevations for ventilation purposes.
BACKGROUND INFORMATION
The subject site and surrounding property were zoned “R-1”, Single Family Dwelling District
before the 1984 City-wide rezoning.
City Council on July 20, 2004, approved Z03 -07 (Ord. 2004-43) rezoning the subject
property from “CC”, Community Commercial District to “LI”, Light Industrial District. The
property owner at the time planned to utilize the property as warehouse inventory for their
retail business, D/RW Honda, and possibly provide lease space for warehousing of goods
and materials. The development project did not move forward after approval of the
rezoning request.
/em