HomeMy WebLinkAboutItem 04 - CU15-47 Grapevine Cricket FieldsTO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE
PLANNING AND ZONING COMMISSION
FROM: BRUNO RUMBELOW, CITY MANAGER
SCOTT WILLIAMS, DEVELOPMENT SERVICES DIRECTOR
MEETING DATE: JANAURY 19, 2016
SUBJECT: DEVELOPMENT SERVICES TECHNICAL REPORT OF
CONDITIONAL USE APPLICATION CU15-47 GRAPEVINE
CRICKET FIELDS
APPLICANT: Thiru Kumaran
PROPERTY LOCATION AND SIZE:
The subject property is addressed as 3451 Foxfire
Lane and is proposed to be platted Lot 1, Block 1,
Grapevine Cricket Fields Addition. The site contains
approximately 20 acres and has approximately 1,752
feet of frontage along Foxfire Lane.
REQUESTED CONDITIONAL USE AND COMMENTS:
The applicant is requesting a Conditional Use Permit to allow for stadium lighting and to
exceed the maximum permitted height of a tent/canopy structure in coniunction with a
cricket field complex on approximately 20 acres.
In the fall of 2000 a zone change request was approved on the subject site and
surrounding 63.2 acres along Foxfire Lane rezoning the property from "R-20" Single Family
District to "RA" Recreational/Amusement District. In the fall of 2015, staff approved
administratively a site plan for an outdoor cricket facility which included three cricket fields,
a wicket practice area and a 1,600 square foot men's/women's dressing room and storage
building, covered viewing area, and associated parking. With this request, the applicant
\ZCU\CU15-48.4 1 January 14, 2016 (9:17AM)
proposes to illuminate one of the cricket fields (the southernmost of the three) with four
stadium lights which are 90 -feet in height; a wicket practice area along the northern
property boundary will also be illuminated by four light standards that are 30 -feet in height.
In lieu of bleacher seating, a 9,600 square foot tent/canopy that can accommodate 450
spectators will be located within the center of the three practice fields. This canopy is 38 -
feet in height which exceeds by three feet the maximum permitted height of 35 -feet. With
approval of a conditional use permit, the 38 -foot canopy height may be allowed.
Lighting levels at the southwest, west and northwest property lines adjacent to the
residential zoning meet the allowed lighting levels of 0.2 footcandles. The total parking
provided is 98 spaces -95 spaces are required. At some point in the future the applicant
plans to add 16 additional parking spaces providing a total of 114 spaces on site. No
parking signs will be permanently installed along Foxfire Lane to discourage parking on the
street.
PRESENT ZONING AND USE:
The property is currently zoned "RA" Recreational Amusement District and is undeveloped.
HISTORY OF TRACT AND SURROUNDING AREA:
The subject property was annexed into the City of Grapevine as part of an approximate
300 acre annexation from the City of Southlake and the Corps of Engineers which was
approved by Council on November 2, 1993 (Ord. 1993-49). This property received the "R-
20" Single Family Designation upon annexation. Some of the property is unplatted and
vacant with some single-family homes and Lonesome Dove Ranch. Property to the
northwest received Zone Change Case Z01-01 (Ord. 2001-13) approved on February 20,
2001, changing the site zoning to "R-5.0" Zero Lot Line District with deed restrictions
requiring all on site development to comply with the regulations of "R-7.5" Single Family
District. Zone Change Z99-22 (Ord. 2000-113) and Conditional Use Permit C000-54 (Ord.
2000-121) were approved on November 7, 2000, changing the zoning on the subject
property to from "R-20", Single Family District to "RA" Recreation/Amusement District and
approving a conditional use permit for on -premise consumption of alcoholic beverages
(beer, wine and mixed drinks) in conjunction with the operation of an existing
recreation/amusement based business (Ranch of Lonesome Dove).
SURROUNDING ZONING AND EXISTING LAND USE:
NORTH: "RA", Recreational/Amusement District and "R-7.5" Single Family
District, Lonesome Dove and Lakeview Estates
SOUTH: "RA", Recreational/Amusement District and "R-12.5" Single Family
District undeveloped and Cannon Homestead
EAST: "RA", Recreation/Amusement District – Ranch of Lonesome Dove
\ZCU\CU15-48.4 2 January 14, 2016 (9:17AM)
WEST: "R-20", Single Family District — unplatted single family homes
AIRPORT IMPACT:
The subject tract is not located within any of the noise zones as defined on the "Aircraft
Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map.
MASTER PLAN APPLICATION:
The Master Plan designates the subject site as Recreational Amusement. The proposed
development does comply with the Recreational/Amusement designation.
THOROUGHFARE PLAN APPLICATION:
Foxfire Lane is not list on the Thoroughfare Plan.
/at
\ZCU\CU15-48.4 3 January 14, 2016 (9:17AM)
TR IA1A
22.295 AC
A ' I, 90'"'1 TR TR
GO P-1) 1 1P6B 1 B6 r
swe TRACTA
6 OOMMON
AREA
3 dS
s . �0
-20
12! 17
13 1 16
10.955 @
0
16
i
19 ? -12.5 1
1B
j 20 1.00 @ 13.699@
Feet
0 150 300 450 600
Date Prepared: 12/31/2015
U
� TR 1
4.25 AC
TR IA7
TR 1A1
5.33 AC
TR 1D
2.04 AC
TR 1C2
10.803 AC
TR 1G
25.6334 @
CU1 5-47
Grapevine Cricket Fields
This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources were
used to gather this information. Every effort was made to ensure the accuracy of this data. however, no guarantee is
given or implied as to the accuracy of said dela.
TR 1G
25.6334 @
CUFD--Ln
UV
CITY OF GRAPEVINE
CONDITIONAL USE APPLICATION
Form 66A„
PART 1. APPLICANT INFORMATION
Name of applicant/ agent:/company/contact
Thiru Kumaran
Street address of applicant/ agent:
217 Creekside Lane
City/ State /Zip Code of applicant / agent:
Coppell, TX 75019
Telephone number of applicant/ agent:
Fax number of applicant/agent
(512) 468-1711
Email address of applicant/agent
Mobile phone number of applicant/agent
PART 2. PROPERTY INFORMATION
Street address of subject property
3420 Foxfire Lane
Legal description of subject property (metes & bounds must be described on 8 1/2"x 11"sheet)
Lot 1 Block 1 Addition
Grapevine Cricket Fields Addition
Size of subject property
18.929 Acres
824,535
Square footage
Present zoning classification: Proposed use of the property:
RA Cricket Fields
Circle yes or no, if applies to this application
Outdoor speakers Yes No
Minimum / maximum district size for conditional use request.,
Minimum lot size 8,000 sq. ft.
Zoning ordinance provision requiring a conditional use:
Section 30
PART 3. PROPERTY OWNER INFORMATION
Name of current property owner.
Texas Cricket Academy
Street address of property owner:
217 Creekside Lane
City / State / Zip Code of property owner:
Coppell, TX 75019
Telephone number of property owner:
Fax number of property owner.-
wner.(512)
(512)468-1711
utt5 --q -1
❑ Submit a letter describing the proposed conditional use and note the request on the site plan document
❑ In the same letter, describe or show on the site plan, and conditional requirements or conditions imposed upon the particular conditional
use by applicable district regulations (example: buffer yards, distance between users)
❑ in the same letter, describe whether the proposed conditional use will, or will not cause substantial harm to the value, use, or enjoyment of
other property in the neighborhood. Also, describe how the proposed conditional use will add to the value, use or enjoyment of other
property in the neighborhood.
❑ Application of site plan approval (Section 47, see attached Form `B').
❑ The site plan submission shall meet the requirements of Section 47, Site Plan Requirements.
❑ All conditional use and conditional use applications are assumed to be complete when filed and will be placed on the agenda for public
hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date.
❑ All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the
next public hearing. Public hearings will not be tabled.
❑ Any changes to a site plan (no matter how minor or major) approved with a conditional use or conditional use permit can only be approved
by city council through the public hearing process.
❑ I have read and understand all the requirements as set forth by the application for conditional use or conditional use permit and
acknowled a that all requirements of this a lication have been met at the time of submittal.
PART 4. SIGNATURE TO AUTHORIZE CONDITIONAL US REQUEST AND PLACE A CONDITIONAL USE
REQUEST SIGN ON THE SUBJECT PROPER'
Thiru Kumaran
Print Applicant's Name:
The State of
County Of
Before Me W ! t 1 � i' C on this day personally appeared t��Oynoci
(notary) (applicant)
known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for the purposes and consideration therein expressed.
(Seal) Given under my hand and seal of office this day of De A.D. 'ZZ (,
4 t pug JULtETA CORTE
Notary Public
STATE OF TEXAS
r 10-12-16 Notary I�tAnd For State Of Tex s..." 4 5 s Fly cosmn Exp.
Thiru Kumaran
Print Property Owners Name:
`-t �
The State Of 1 C,Is
CountyOf i, C i c'�
-ThBefore Me �)1A`\6 G� on this day personally appeared I
(notary) (property owner)
known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and
acknowledged to me that he executed the same for the purposes and consideration therein�expressed.
7,0
(Seal) Given under my hand and seal of office this c� day of i `e d'y\b—r Y' p.
rp� JULIE`I°A CORTE
Notary Public
Notary In nd For State Of Texas
STATE OF TEXAS
r � =V My Corrrn, Exp. 10-12-16
DEC 8 2015
d
ct�r�L-LO
IMMM4491c]
All Conditional Use and Special Use Applications are assumed to be complete
when filed and will be placed on the agenda for public hearing at the discretion of
the staff. Based on the size of the agenda, your application may be scheduled to a
later date.
All public hearings will be opened and testimony given by applicants and
interested citizenry. Public hearings may be continued to the next public hearing.
Public hearings will not be tabled.
Any changes to a site plan (no matter how minor or major) approved with a
conditional use or a special use permit can only be approved by city council
through the public hearing process.
Any application for a change in zoning or for an amendment to the zoning
ordinance shall have, from the date of submittal, a period of four months to
request and be scheduled on an agenda before the Planning and Zoning
Commission and City Council. If after said period of four months an application
has not been scheduled before the Commission and Council said application shall
be considered withdrawn, with forfeiture of all filing fees. The application, along
with the required filing fee may be resubmitted any time thereafter for
reconsideration. Delays in scheduling applications before the Planning and
Zoning Commission and City Council created by city staff shall not be considered
2 part of the four month period.
I have read and understand all of the requirements as set forth by the application
for conditional use or special use permit and acknowledge that all requirements of
this application have been met at the time of submittal.
Signature of Applicant
Date: 1)- 16
T
I
Signature of Owner CL/"�
Date:
AN ORDINANCE ISSUING A CONDITIONAL USE PERMIT IN
ACCORDANCE WITH SECTION 48 OF ORDINANCE
NO. 82-73, THE COMPREHENSIVE ZONING ORDINANCE
OF THE CITY OF GRAPEVINE, TEXAS, SAME BEING ALSO
KNOWN AS APPENDIX "D" OF THE CITY CODE, BY
GRANTING CONDITIONAL USE PERMIT CU15-47 FOR
STADIUM LIGHTING AND TO EXCEED THE MAXIMUM
PERMITTED HEIGHT OF A TENT/CANOPY IN A DISTRICT
ZONED "RA" RECREATION/AMUSEMENT DISTRICT ALL IN
ACCORDANCE WITH A SITE PLAN APPROVED PURSUANT
TO SECTION 47 OF ORDINANCE NO. 82-73 AND ALL
OTHER CONDITIONS, RESTRICTIONS AND SAFEGUARDS
IMPOSED HEREIN; CORRECTING THE OFFICIAL ZONING
MAP; PRESERVING ALL OTHER PORTIONS OF THE
ZONING ORDINANCE; PROVIDING A CLAUSE RELATING
TO SEVERABILITY; DETERMINING THAT THE PUBLIC
INTERESTS, MORALS AND GENERAL WELFARE DEMAND
THE ISSUANCE OF THIS CONDITIONAL USE PERMIT;
PROVIDING A PENALTY NOT TO EXCEED THE SUM OF
TWO THOUSAND DOLLARS ($2,000.00); DECLARING AN
EMERGENCY AND PROVIDING AN EFFECTIVE DATE
q1s-Y17
Ga"6-01/16
CR ►cke7- F/ELD3
WHEREAS, an application was made requesting issuance of a conditional use
permit by making applications for same with the Planning and Zoning Commission of the
City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the
City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites
having been complied with, the case having come before the City Council of the City of
Grapevine, Texas, after all legal notices requirements, conditions and prerequisites having
been complied with; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council did consider the following factors in making a determination as to
whether this requested conditional use permit should be granted or denied: safety of the
motoring public and the pedestrians using the facilities in the area immediately surrounding
the site; safety from fire hazards and measures for fire control; protection of adjacent
property from flood or water damages, noise producing elements, and glare of the
vehicular and stationary lights and effect of such lights on established character of the
neighborhood; location, lighting, and types of signs and relation of signs to traffic control
and adjacent property; street size and adequacy of width for traffic reasonably expected to
be generated by the proposed use around the site and in the immediate neighborhood;
adequacy of parking as determined by requirements of this ordinance for off-street parking
facilities; location of ingress and egress points for parking and off-street locating spaces,
and protection of public health by surfacing on all parking areas to control dust; effect on
the promotion of health and the general welfare; effect on light and air; the effect on the
overcrowding of the land; the effect on the concentration of population; the effect on the
transportation, water, sewerage, schools, parks and other facilities; and
WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing
called by the City Council of the City of Grapevine, Texas, did consider the following factors
in making a determination as to whether this requested conditional use permit should be
granted or denied; effect on the congestion of the streets, the fire hazards, panics and
other dangers possibly present in the securing of safety from same, the effect on the
promotion of health and the general welfare, effect on adequate light and air, the effect on
the overcrowding of the land, the effect on the concentration of population, the effect on
the transportation, water, sewerage, schools, parks and other public facilities; and
WHEREAS, all of the requirements of Section 48 of Ordinance No. 82-73 have been
satisfied by the submission of evidence at a public hearing; and
WHEREAS, the City Council further considered among other things the character of
the existing zoning district and its peculiar suitability for particular uses and with the view to
conserve the value of buildings and encourage the most appropriate use of land
throughout this City; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is
a public necessity for the granting of this conditional use permit, that the public demands it,
that the public interest clearly requires the amendment, that the zoning changes do not
unreasonably invade the rights of those who bought or improved property with reference to
the classification which existed at the time their original investment was made; and
WHEREAS, the City Council of the City of Grapevine, Texas, does find that the
conditional use permit lessens the congestion in the streets, helps secure safety from fire,
panic and other dangers, prevents the overcrowding of land, avoids undue concentration of
population, facilitates the adequate provisions of transportation, water, sewerage, schools,
parks and other public requirements; and
WHEREAS, the City Council of the City of Grapevine, Texas, has determined that
there is a necessity and need for this conditional use permit and has also found and
determined that there has been a change in the conditions of the property surrounding and
in close proximity to the property requested for a change since this property was originally
classified and, therefore, feels that the issuance of this conditional use permit for the
particular piece of property is needed, is called for, and is in the best interest of the public
at large, the citizens of the City of Grapevine, Texas, and helps promote the general health,
safety and welfare of this community.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS:
ORD. NO. 2
Section 1. That the City does hereby issue a conditional use permit in accordance
with Section 48 of Ordinance No. 82-73, the Comprehensive Zoning Ordinance of the City
of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by granting
Conditional Use Permit CU15-47 to allow for stadium lighting and to exceed the maximum
permitted height of a tent/canopy structure in conjunction with a cricket field complex on
approximately 20 acres (Grapevine Cricket Fields) in a district zoned "RA"
Recreation/Amusement District within the following described property: proposed to be
platted as Lot 1, Block 1, Grapevine Cricket Fields Addition (3451 Foxfire Lane) all in
accordance with a site plan approved pursuant to Section 47 of Ordinance No. 82-73,
attached hereto and made a part hereof as Exhibit "A", and all other conditions,
restrictions, and safeguards imposed herein, including but not limited to the following:
None.
Section 2. That the City Manager is hereby directed to amend the official zoning
map of the City of Grapevine, Texas, to reflect the herein conditional use permit.
Section 3. That in all other respects the use of the tract or tracts of land herein
above described shall be subject to all the applicable regulations contained in said City of
Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of
Grapevine, Texas.
Section 4. That the zoning regulations and districts as herein established have
been made in accordance with the comprehensive plan for the purpose of promoting
health, safety, morals and the general welfare of the community. They have been
designed with respect to both present conditions and the conditions reasonably anticipated
to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from
fire, panic, flood and other dangers; provide adequate light and air; to prevent
overcrowding of land, to avoid undue concentration of population; facilitate the adequate
provisions of transportation, water, sewerage, drainage and surface water, parks and other
public requirements, and to make adequate provisions for the normal business, commercial
needs and development of the community. They have been made with reasonable
consideration, among other things, of the character of the district, and its peculiar suitability
for the particular uses and with a view of conserving the value of buildings and encouraging
the most appropriate use of land throughout the community.
Section 5. That this ordinance shall be cumulative of all other ordinances of the
City of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said
ordinances except in those instances where provisions of those ordinances which are in
direct conflict with the provisions of this ordinance.
Section 6. That the terms and provisions of this ordinance shall be deemed to be
severable and that if the validity of the zoning affecting any portion of the tract or tracts of
land described herein shall be declared to be invalid, the same shall not affect the validity
of the zoning of the balance of the tract or tracts of land described herein.
ORD. NO. 3
Section 7. That any person violating any of the provisions of this ordinance shall
be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum
not to exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed
committed upon each day during or on which a violation occurs or continues.
Section 8. That the fact that the present ordinances and regulations of the City of
Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace
and general welfare of the inhabitants of the City of Grapevine, Texas, creates an
emergency for the immediate preservation of the public business, property, health, safety
and general welfare of the public which requires that this ordinance shall become effective
from and after the date of its final passage, and it is accordingly so ordained.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF
GRAPEVINE, TEXAS on this the 19th day of January, 2016.
ATTEST:
ORD. NO. 4
ZONING RA
— , — , — . — , — . _ _ _ _ _ .� - - - -- N89 59' ST'E 952.40'
ZONING: R-7 .5 ^ i — — — — — — — — — — — — — — 10' REARYARD SETBACK —T- — — — — — — — — — -PROPOSED-
-10'
STREET
PROPOSED 6' WOOD 3 �' "'�-1LwIGHTING TURNAROUND
SCREENING FENCE _ 3p, /
30' HIGH
N88-33'23' 83,161.I WICKET
SIGHTING —
FUTURE
PARKING
LIGHTING
-0' HIGH
FRONT YARD SETBACK
----- — —----------
589° 29'58"W 265.11'
NOl° 40' 18"W 30.01-'
6' WOOD SCREENING FENCE
EX. FIRE HYC
ZONING R-12.5
PROPOSED
CRICKET FIELD
(75 YD RAD)
/ LIGHTING
90' HIGH
PROPOSED
SIDEWALK
FIRE HOSE LAY
DISTANCE ALONG FIRE
LANE = 420' +/-
90' HIGH
PROPOSED--�
RIGHT-OF-WAY
DEDICATION
(PER PLAT)
PROPOSED
CRIICKyET FIELD
i
EXISTING -1
GATE I
225'
735' b• 0'
PROPERTY
1)B9. l
PROPOSED
80' X 120'
CANOPY
STRUCTURE
I
— ,N cao' 02"vJ 170.42 . GRAPHIC SCALE
PARKING
SIGN so o z5 .w
LEGEND t
SAWCUT ( IN FEET )
PAVEMENT (CONCRETE) I inch = 50 It
✓. 7" 3500 P.S.I. ON 8" LIME STABILIZED
SUBGRAOE
F PAVEMENT (ASPHALT)
2" TYPE O ON 8" T%DOT TWE A OR D,
GRADE 1 OR 2 GRANULAR BASE
% T.SIDEWALK /FLATWORK
j 4' 3500 P.S.I. THICK OTHERWISE
NO
PARKING
SIGN
NO
PARKING
SIGN d
Ey/ PARKING r
SIGN L
NO
PARKING
/ SIGN
0
N15° 01'2-"-
FIELD
1'2P•cFIELD \NO LIGHTING90' HIGH
PROPOSED PROPOSED / PARKING
CRICKET FIELD IRRIGATION SIGN
(75 YD RAD) POND
25• FRONT YARD
ZONED: RA NO
CURRENT USE: VACANT PARKING
SIGN
p' 735• 204.16' EX. 18" RCP
El
/ / ( NO
/ PARKING
SIGN
FIELD PROP. N00° 30' 02"W 263.38'
LIGHTING PROPERTY /
90' HIGH LINE EXIST.
/ PROPERTY
/ LINE
— — — — — PROPOSED NO
BACK _ _, RIGHT-OF-WAY PARKING
— DEDICATION
(PER PLAT) I SIGN
N89° 29'58"E 676.39'
NO
PARKING
SIGN
I SI11, 18
c.m.luy
EinU) fOxPftE
VICINITY MAP
NOT TO SCALE
GRAPEVINE, TEXAS
b11L UAIP,
[T- --_
I
I
o
I
I
I
Z
�
I
zI
I
W
I ERMANENT UTILITY
6 SEATS (OUTDOOR COMMERCIAL
EASEMENT
K
VOLUME 15499.
PAGE 83
451, SPECTATORS /6=75
D. R. T. C.T.
Q
3
I
I
135'-
�
I 1
II I
O
II
1
I
I
OPEN SPACE REQUIRED
II
�
I
�
(I I
z
II
z
No
0
II
N
II I
(809. MAX)
II
I
;EUSE.
IMPERVIOUS SURFACE PROVIDED
64,107 IF (1.47 AC)
OiIDEYARD
TACK
II
I
—�
a —IN EA
SIGN
®
a ,
®I
�
II
�
� R1p
II
I
i ®
ORDINANCES.
I
Iry
APPLICANT.
DEVELOPER,
-PROPOSE
—SHOVE ?a
DEPARTMENT OF DEVELOPMENT SERVICES
�5'
RE TR
z
TEXAS CRICKET ACADEMY
CONTACT: KUMARAN (KENNY) THIRU
-STRUOTUR
II
4
Z
z
I
I I
+l,
b
W
Ir
MANSFIELD, TX 76063
COPPELL, TX 75019SEPARATE
�
I
N
I
Il.m
(@ least 48 hours prior to digging)
DISCIPLINES. EACH SUBCONTRACTOR SHALL BE PROVIDED WITH AL
SHEETS WITHIN THIS PLAN SET.
o
3
�
LI
I
e
(I I
II p5
I
I
I
PERMANENT
UTIUTY EASEMENT
VOLUME 115603.
21
D.R.T.C.T.
I
FUTURE
PARKING
LIGHTING
-0' HIGH
FRONT YARD SETBACK
----- — —----------
589° 29'58"W 265.11'
NOl° 40' 18"W 30.01-'
6' WOOD SCREENING FENCE
EX. FIRE HYC
ZONING R-12.5
PROPOSED
CRICKET FIELD
(75 YD RAD)
/ LIGHTING
90' HIGH
PROPOSED
SIDEWALK
FIRE HOSE LAY
DISTANCE ALONG FIRE
LANE = 420' +/-
90' HIGH
PROPOSED--�
RIGHT-OF-WAY
DEDICATION
(PER PLAT)
PROPOSED
CRIICKyET FIELD
i
EXISTING -1
GATE I
225'
735' b• 0'
PROPERTY
1)B9. l
PROPOSED
80' X 120'
CANOPY
STRUCTURE
I
— ,N cao' 02"vJ 170.42 . GRAPHIC SCALE
PARKING
SIGN so o z5 .w
LEGEND t
SAWCUT ( IN FEET )
PAVEMENT (CONCRETE) I inch = 50 It
✓. 7" 3500 P.S.I. ON 8" LIME STABILIZED
SUBGRAOE
F PAVEMENT (ASPHALT)
2" TYPE O ON 8" T%DOT TWE A OR D,
GRADE 1 OR 2 GRANULAR BASE
% T.SIDEWALK /FLATWORK
j 4' 3500 P.S.I. THICK OTHERWISE
NO
PARKING
SIGN
NO
PARKING
SIGN d
Ey/ PARKING r
SIGN L
NO
PARKING
/ SIGN
0
N15° 01'2-"-
FIELD
1'2P•cFIELD \NO LIGHTING90' HIGH
PROPOSED PROPOSED / PARKING
CRICKET FIELD IRRIGATION SIGN
(75 YD RAD) POND
25• FRONT YARD
ZONED: RA NO
CURRENT USE: VACANT PARKING
SIGN
p' 735• 204.16' EX. 18" RCP
El
/ / ( NO
/ PARKING
SIGN
FIELD PROP. N00° 30' 02"W 263.38'
LIGHTING PROPERTY /
90' HIGH LINE EXIST.
/ PROPERTY
/ LINE
— — — — — PROPOSED NO
BACK _ _, RIGHT-OF-WAY PARKING
— DEDICATION
(PER PLAT) I SIGN
N89° 29'58"E 676.39'
NO
PARKING
SIGN
I SI11, 18
c.m.luy
EinU) fOxPftE
VICINITY MAP
NOT TO SCALE
GRAPEVINE, TEXAS
b11L UAIP,
LAND USE:
RECREATONAL/AMUSEMENT
TOTAL LOT AREA:
20 ACRES (GROSS)
18.029 ACRES (NET)
PARKING REQUIRED FOR USE:
20 SPACES PLUS 1 FOR EACH
=
6 SEATS (OUTDOOR COMMERCIAL
AMUSEMENTS REF ORD. 56.C.8)
NO
PARKING
451, SPECTATORS /6=75
51
720=95 REQUIRED
TOTAL PARKING PROVIDED:
98 SPACES (4 REO'D HANDICAP)
FUTURE PARKING PROVIDED:
114 SPACES (5 REO'D HANDICAP)
RESTROOM/SHOWER FACILITY
1,600 S0, FT,
OPEN SPACE REQUIRED
164,908 IF (3.79 AC)
(20% SITE AREA)
OPEN SPACE PROVIDED
258,561 IF (5.94 AC)
BUILDING COVERAGE ALLOWED
494,728 IF (11.36 AC)
(BOX MAX)
No
BUILDING COVERAGE PROVIDED
11,200 IF (0.26 AC)
IMPERVIOUS SURFACE ALLOWED
659,638 IF (15.14 AC)
(809. MAX)
PARKING
SIGN
IMPERVIOUS SURFACE PROVIDED
64,107 IF (1.47 AC)
1, SITE PLAN HAS BEEN PREPARED AS
E%HINT FOR PROPERTY ZONED
RECREATIONAL/AMUSEMENT LOCATED
LESS THAN 100' FROM RESIDENTIAL
DISTRICT.
2. ALL PROPERTY LINES ABUTTING A
RESIDENTIAL DISTRICT SHALL HAVE A
6' SCREEN FENCE PER SECTION 30 OF
ZONING ORDINANCE.
3. NO NET FILL OF SOIL IS ALLOWED ON
SITE PER U.S. ARMY CORPS OF
ENGINEERS REQUIREMENTS.
4. YARD REQUIREMENTS: FRONT - 25
FEET, SIDE - 10 FEET, REAR - 10
FEET.
5. LANDSCAPING REQUIREMENTS ARE
PROVIDED PER SECTION 53 OF ZONING
ORDINANCE.
6. OFF-STREET PARKING HAS BEEN
PROVIDED PER SECTION 56 OF THE
ZONING ORDINANCE.
7. ALL DIMENSIONS ARE TO FACE OF
CURB UNLESS OTHERMISE NOTED.
8. ALL REQUIREMENTS OF THE GRAPEVNE
SOIL EROSION CONTROL ORDINANCE
SHALL BE MET DURING THE PERIOD OF
CONSTRUCTION.
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER:CU-15-47
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
OXF
E L
Conditional Use Request CU15-47 is a
,NE
A,
=
request to allow for the development of a
ASPHALT NO
CONNECTION PARKING
NO
PARKING
�— NO
PARKING
cricket filed complex along with stadium
lighting, a practice wicket area, and to
CHAIRMAN
SIGN
SIGN
SIGN
exceed the maximum permitted height of a
DATE:
tent/canopy structure on 20 acres.
No
No
No
SHEET' 1 OF 9
PARKING
SIGN
ZONING RA
PARKING
SIGN
PARKING
SIGN
®
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
i ®
ORDINANCES.
APPLICANT.
DEVELOPER,
DEPARTMENT OF DEVELOPMENT SERVICES
BANNISTER ENGINEERING, LLC
CONTACT: BRANDON O'DONALD, P.E., CFM
TEXAS CRICKET ACADEMY
CONTACT: KUMARAN (KENNY) THIRU
• 9,
Know Wbat4S below.
BRAN DONOBANNISTERENG.COM
240 N. MITCHELL ROAD
KE NNYOTXCRICKET.COM
217 CREEKSIDE LANE
Call before you dig.
A
INFORMATION ON THIS SHEET IS PERTINENT TO ALL OTHER DESIGI
SHEETS IN THIS SET OF DRAWINGS. THE CONTRACTOR SHALL NOT
MANSFIELD, TX 76063
COPPELL, TX 75019SEPARATE
DRAWINGS FROM THE SET FOR DISTRIBUTION TO SP CH
(817)842-2094
(512) 468-1711
(@ least 48 hours prior to digging)
DISCIPLINES. EACH SUBCONTRACTOR SHALL BE PROVIDED WITH AL
SHEETS WITHIN THIS PLAN SET.
l $
V
I—� z
W
WE
z
_ 2
ZE n
Z u~i
LU ry
z
® W
J
LLJ H
LL LU U.) iii
V LU ~ �
H — u (—
z
W 0 > LU 0
Z —I a.
LA z
WMA
Ila. II -11
V)
V z
cW
G
F -i
� 1a
BWDON O'DO,YALOW
saz»��
R 'YksyS/pkAL tMU.7°
l•It-
SHEET NO.
C-2.1
i
...... _._._. ......
566.5
7l
569.26
ME
569.2D
I/
I m
ON-SITE
BENCHMARK
BM#1
to
FIELD
FA
I
I
57.45 567.22567.00 566.00
ME ME ME ME
565.60
568
565.30 564.04
569.55 569 ZR } O
.566 9. 5 � ebb
�. / N _
I
566.40 DD EDEN 563.58
9.15 556
m 97 n
V � 563.78
563.28
\� I
0
9.35 569.3 f
567.30) f 569.15 ��-56 ].30 /
569.25 3 64.0
566.46 ME:
569.15 /
566.6 569.35 569.35 �566.60i0
9.35 PROPOSED l h
�O CRICKET �'� t
FlELDr /
1
J
566.40 h �� I
h 569.25I / ME4.34
565.40
567.5 569.35 569.35
O
566.40 567.30 \ '
"P 566.30
�_,.---567.30
se
6°j��56g rr l
® 66.71 566.47 Y•.®..1
E ME
566.36
YL�+ ME
1 `565.70
PROPOSED
CRICKET
FIELD
/ 1
_ I
/ 563.
563.5'
43 56 .4 O
AU 1XI A, L II, S o
FOXFIRE LANE -6-
18" RCP
Q
Know what's below.
Call before you dig.
(@ least 48 hours prior to digging)
0
W
J
LULL
Z
W (r,
z
V
LU
u
Z e
1�1 H W
V
GRAPHIC SCALE
21
tLl
W _P
IN FEET)
1 i..h = 50 ft.
LL
GRADING LEGEND
e Z
¢
f K
EXISTING CONTOUR
Z
o U'
-1.7- PROPOSED CONTOURS
W ry
DIRECTION OF FLOW
607.50 TOP OF PAVEMENT
OR PROPOSED GRADE
ME MATCH EXISTING
78
F
,_
ON-SITE
BENCHMARK
BM#1
to
FIELD
FA
I
I
57.45 567.22567.00 566.00
ME ME ME ME
565.60
568
565.30 564.04
569.55 569 ZR } O
.566 9. 5 � ebb
�. / N _
I
566.40 DD EDEN 563.58
9.15 556
m 97 n
V � 563.78
563.28
\� I
0
9.35 569.3 f
567.30) f 569.15 ��-56 ].30 /
569.25 3 64.0
566.46 ME:
569.15 /
566.6 569.35 569.35 �566.60i0
9.35 PROPOSED l h
�O CRICKET �'� t
FlELDr /
1
J
566.40 h �� I
h 569.25I / ME4.34
565.40
567.5 569.35 569.35
O
566.40 567.30 \ '
"P 566.30
�_,.---567.30
se
6°j��56g rr l
® 66.71 566.47 Y•.®..1
E ME
566.36
YL�+ ME
1 `565.70
PROPOSED
CRICKET
FIELD
/ 1
_ I
/ 563.
563.5'
43 56 .4 O
AU 1XI A, L II, S o
FOXFIRE LANE -6-
18" RCP
Q
Know what's below.
Call before you dig.
(@ least 48 hours prior to digging)
1. ALL SLOPES WITHIN ACCESSIBLE PARKING
AREAS SHALL NOT EXCEED 2.0% IN ALL
DIRECTIONS. ALL SLOPES At NO
ACCESSIBLE ROUTES SHALL NOT EXCEED
5.0% LONGITUDINALLY AND 2.0% IN
CROSS -SLOPE.
2, ALL SPOT ELEVATIONS ARE TO TOP OF
PAVEMENT (GUTTER LINE) UNLESS
OTHERWISE NOTED. ADD 0.5 FOR TOP OF
CI1R8.
3. NO NET FILL OF SOIL IS ALLOWED ON SITE
PER U.S. ARMY CORPS OF ENGINEERS
REQUIREMENTS.
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER:CU-15-47
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
st4EEr 2 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
U)
0
W
J
LULL
Z
W (r,
z
V
LU
u
Z e
1�1 H W
V
GRAPHIC SCALE
21
tLl
W _P
IN FEET)
1 i..h = 50 ft.
LL
GRADING LEGEND
e Z
¢
f K
EXISTING CONTOUR
Z
o U'
-1.7- PROPOSED CONTOURS
W ry
DIRECTION OF FLOW
607.50 TOP OF PAVEMENT
OR PROPOSED GRADE
ME MATCH EXISTING
fl
NOTES
1. ALL SLOPES WITHIN ACCESSIBLE PARKING
AREAS SHALL NOT EXCEED 2.0% IN ALL
DIRECTIONS. ALL SLOPES At NO
ACCESSIBLE ROUTES SHALL NOT EXCEED
5.0% LONGITUDINALLY AND 2.0% IN
CROSS -SLOPE.
2, ALL SPOT ELEVATIONS ARE TO TOP OF
PAVEMENT (GUTTER LINE) UNLESS
OTHERWISE NOTED. ADD 0.5 FOR TOP OF
CI1R8.
3. NO NET FILL OF SOIL IS ALLOWED ON SITE
PER U.S. ARMY CORPS OF ENGINEERS
REQUIREMENTS.
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER:CU-15-47
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
st4EEr 2 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
U)
0
J
LULL
Z
W (r,
z
LU
1�1 H W
V
V Q
LU LL
Z UI a'
Ln
®®/
M
LLL>
Wr�
V
bLINUHMAKKS
BMRi:
TOP OF EXISTING SANITARY SEWER MANHOLE
RIM LOCATED NEAR THE SOUTHWEST
PROPERTY CORNER.
N: 7040527.68
E: 2390864.22
ELEV.=568.15
SOURCE BENCHMARK:
GRAPEVINE MONUMENT NUMBER 1, ALUMINUM ROD
WITH CAP FOUND 0.4 FEET BELOW ACCESS COVER,
ACCESS COVER STAMPED 'CITY OF GRAPEVINE,
MON. 1". MONUMENT IS LOCATED APPROXIMATELY
300 FEET SOUTH OF KIMBALL ROAD AND
SILVERCREST LANE INTERSECTION IN THE CENTER
OF A GRASS MEDIAN.
ELEV. = 603.45'
THIS SHEET IS PERTINENT TO ALL OTHER 1
SET OF DRAWINGS. THE CONTRACTOR SHALT
NGS FROM THE SET FOR DISTRIBUTION TO
H SUBCONTRACTOR SHALL BE PROVIDED WI
S
i
p
SHEET NO.
C-3.1
PROPOSED 6' WOOD
SCREENING FENCE
0
2
WOOD SCREENING FENCE
GRAPHIC SCALE
I
IN FEET)
1 inch = 50 It.
LEGEND:
OEXISTING TREE TO REMAIN
t n J EXISTING TREE TO BE REMOVED
LANDSCAPE TABULATION:
LOTAREA: __---_------—__
824,538 sf (38,93 act
OPEN SPACE REQUIRED: 20% SITE AREA
OPEN SPACE PROVIDED:
164,908 d(3.79 a c)
258,561 d (5.94 ac)
PARKING REQUIRED:
PARKING PROVIDED:
FUTURE PARKING PROVIDED:
95:PACES
98 SPACES
114 SPACES
GROSS PARKING LOT AREA:
PARKING LANDSCAPE AREA REQUIRED: 10% GROSS PARKING
LANDSCAPE AREA PROVIDED:
52,907 sf
5,291sf
5,318 sf
TREES REQUIRED:
1 TREE/2,500 SF OF REQ'D OPEN SPACE
1TREE/ 4005F OF REQ'D PARKING LOT LANDSCAPEAREA
66 TREES
13TREES
TOTAL 79 TREES
EXISTING TREES TO REMAIN:
9 TREES
NEW TREES REQUIRED:
70TREES
_
TREES PROVIDED:
SHADETREES
ORNAMENTAL TREES:
57 TREE:
21TREE:
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER: CU -15-47
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET 3 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
i
NOTE:
Know what's below. Ad<as si dhWrb e tr con tr on zM1all b flM gntlM ane a dElknetl by we. Th <
Hall be o-eyar<a ava mamrau,m vvm P<rmav<vc cava or yaa. is a<nl<v<a vdu, a
Call before you dig. mp Imam o 7v my<rage. Thk k fl<wa<an ar as m m<ba<x a <oro arvuae m<
(@ least 48 hours prior to digging) Prof m
LU
Ll—
LU U,
Z Q
�gW
Y w H W
eV -I LL Q
W LL LU �U/y
V
Z
WCL
M z
V
SHEET NO
GENERAL NOTES:
1. Locate all utilities prior to digging. Contractor shall be responsible for all damage
incurred by his/her work.
2. Contractor shall advise the Owner and Landscape Architect of any condition found
on site which prohibits installation as shown on these plans.
3. If a discrepancy between drawings and plant schedule is found, the drawings shall
take precedent over the plant schedule.
4. Plant material shall comply with all sizing and grading standards of the latest edition
of'American Standard for Nursery Stock.'
5. Contractor shall stake out tree locations and bed configuration for approval by
Owner prior to installation.
6. Substitutions shall not be made without prior written authorization from the Owner or
Landscape Architect.
7. All disturbed areas not indicated as planting beds shall be sodded or seeded by
Contractor to provide an established turf area.
8. Contractor shall remove reasonable amount of stones, dead roots, detritus and
other undesirable material from existing soil.
9. If rocks are encountered, remove to a depth of 3" and add 3" of friable fertile topsoil
to all sodded areas. Contractor to ensure that site is graded according to the
Engineer's grading plan.
10. Lawn areas shall have 3" minimum friable topsoil and be treated with fertilizer
applied at a rate of 20 pounds per 1,000 square feet.
11. Soil preparation for planting beds shall be as follows:
3" of organic compost
20 pounds of organic fertilizer/ 1,000 sf of bed area
Till bed to a depth of 6" to 8"
Check soil acidity. Soil acidity should range from 5.0 to 7.0 pH. Regulate if
necessary.
12. Provide steel edge between all plant beds and lawn areas unless indicated
differently on plans.
13. Tree planting pits shall be cleared of undesirable material and backfilled with
prepared top soil. Place 1" of compost and 3" of shredded hardwood mulch on top
of root ball.
14. The Contractor will be held liable for any damage caused to trees due to improper
staking methods, including absence of staking throughout the warranty period.
15. Trees shall be planted at least 2.5 feet from any right-of-way line, curb, walk or fire
hydrant, and outside all utility easements.
16. Trees shall be planted at least 8 feet from any public utility line where possible. In
the event this is not possible, Contractor shall install a root barrier, per the detail(s)
noted on this sheet.
17. Trees overhanging walks and parking areas shall have a clear trunk height of 7 feet
from finish surface grade.
18. Contractor shall warranty plant material to remain alive and healthy for a period of
one year after the final acceptance. All plant material shall be maintained in a
healthy condition in accordance with the season. Dead, damaged or destroyed
plant material shall be replaced in kind within thirty days. Warranty shall not include
damage for loss of plant material due to natural causes, acts of vandalism or
negligence on the part of the owner.
19. Landscape areas shall be kept free of trash, litter and weeds.
20. An automatic irrigation system shall be provided to maintain all landscape areas.
Overspray on streets is prohibited.
22. Installing contractor to maintain landscaping for 30 days from owner occupancy to
establish plants and grass, mowing and trimming to be included.
23. All areas disturbed by construction shall be fine graded and re-established by sod.
These areas shall be irrigated and maintained until permanent stand of grass is
achieved with a minimum of 70% coverage. This is to include all areas to the back
of curb around the property.
24. All landscape areas,whether required or not must have an electronically controlled
underground landscape irrigation system installed in compliance with current Texas
Commission on Environmental Equality.
NOTES: /
d s
/ -
1. DO NOT HEAVILY PRUNE THE TREE
METAL'T-POST'. THREE PER TREE, SPACED
AT PLANTING. PRUNE ONLY
�� ROOT BALL DOESN'T SHIFT.
TREE. GUV WIRE SHALL
CROSSOVER LIMBS.
BRANCHES. INTERIOR TWIGS
FLEXIBILITY
ALLOW SOME FLEXIBILITY OF TRUNK.
ALLOW SOME
LEADERS, AND BROKEN
EN OR DEAD
DEAD
OR TAMPED SOIL.
NOT
FIR REMOVE; HOWEVER, ETERMINAL
BRANCH THE TERMINAL BUDS OF
PROTECT TRUNK FROM GUY WIRE
IO
AND LATERAL BRANCHES MAY DE
AND LATER SOME INTERIOR Y BE
05
EDGE OF THE CROWN.
BDAMAGE
WITH RUBBER COVER. (SEE NOTE BELOW)
ELOW)
PRUNED; HOWEVER, DO NOT
3" ca., 12' ht., Fuii, Mafchln
SUCH THAT THE TRUNK FLARE IS
SET TOP OF ROOT BALL 1' TO 2'
REMOVE THE TERMINAL DUDS OF
saidCypress
BALL. TREES WHERE THE TRUNK
ABOVE FINISHED GRADE.
BRANCHES THAT EXTEND TO THE
EDGE OF THE CROWN.
Plstaohla chic -Is
L.U-troema indica
REJECTED. DONOTCOVERTHE
(2') MULCH LAVER ABOVE PREPARED SOIL.
TOP OF THE ROOT BALL WITH SOIL.
9
3. REMOVE ALL TWINE, ROPE, WIRE
MAINTAIN THE MULCH WEED -FREE FOR
2. EACH TREE MUST SE PLANTED
ROOT BALL.
A MIN. OF THREE YEARS AFTER
SUCH THAT THE TRUNK FLARE IS
I�
SH
BA KE AROUND
BASKET E BASKET IN FOU L. PLACE
FOUR PLACES
THE WIRE DOWN
PLANTING.
VISIBLE AT THE TOP OF THE ROOT
DATE:
o
W HIGH EARTH SAUCER IN 5'
BALL. TREES WHERE THE TRUNK
Raphidepis indica
Indian HaWlhom Clara'
DIA. RING AROUND ROOT BALL,
FLARE IS NOT VISIBLE SHALL BE
18
Leuco h lum 5utecens
Texas Sae
REJECTED. DONOTCOVERTHE
C
23
TOP OF THE ROOT S&L WITH SOIL.
Dwarf Burord Holly
5 gal., 24" ht, 30" O.C., triangular spacing
3, REMOVE ALL TWINE, ROPE, WIRE
4
Naldina domesbca Fire Wer
AND BURLAP FROM TOP HALF OF
5 gal., 24" ht, 30" O.C., than ulara acin
TAMP SOIL AROUND ROOT BALL BASE
ROOT BALL. I
FIRMLY WITH FOOT PRESSURE SO THAT
Hameln Gass
Salvia Red'
ROOT BALL DOESN'T SHIFT.
4. IF PLANT IS SHIPPED WITH A WIRE
BASKET AROUND ROOT BALL. CUT
PLACE ROOT BALLON UNEXCAVATED
THE WIRE BASKET I�N�
OR TAMPED SOIL.
8 NFTOOUPR��PALNAiC�NEGS
ANp F002WAL'IREES WITHIN OU FEET OF A PLAYGROUND OR
HOLE. PLAYFIELD ,UNLESS SEPARATED BY VEHICULAR PAVING,
SHALL BE REINFORCED WITH WOOD STAKES (SEE DET. B,
THIS SHEET) IN LIEU OF METAL-T�POSTS'.
%qI TREE PLANTING DETAIL
NGTTa.�A1E
!'1
Q
3" HIGH EARTH SAUCER
1"COMPOST AND 2" MULCH.BEYOND EDGE OF ROOT BALL.BACKFILL PIT WITH PREEXCAVATE PIT TO A WIDTH EQUAL TO 2.5 TIMES
SOIL PER GENERAL NOTTHE ROOT BALL WIDTH. PLACE ROOT BALL ON
UNEXCAVATED OR TAMPED SOIL. SCARIFY
SIDES OF PIT. CONTRACTOR MAY EXCAVATE
LARGER PIT FOR MULTIPLE PLANTINGS.
REMOVE ROOT BALL FROM
CONTAINER AND SCARIFY.
e
L�
0
B SHRUB PLANTING DETAIL
NOT TO SCALE
a,e ru�c Hrc v nx¢ .a e< IBnU
�,au�"iuis r'°oais s�°0S s, "m veno.
� (a>.4rnwaour� awm
�.� sae urr�vn oanasx
J='
rore,",ra =at
D- rwrew
IM EY
sno roams
'z KAawA.s To a Har Drum oALv.
artlrr£ anal 7D.n ria
~ Alm --d
miwlo . Acea Aic -
wro o s
s Au FIaAE PAraL.
TO ea stt Lsw, m/
slseew xor m oaAm e• ro
ARWIWDAie CRA.E - A.AISi POST
Aala As NFmm. aAenNx
caxrauous PAx¢ aaAsua¢ of 1r
eft Nft&%,"I6wt'
FSHrE eaums eseLE mm sllaxr os
Ao.nlrro I'Raltptt.
SCREENING FENCEFENCE
NOTTO SCALE
PLANT LIST AND SPECIFICATIONS:
NOTES:
d s
/ -
1. DO NOT HEAVILY PRUNE THE TREE
COMMON NAME
AT PLANTING. ONLY
CROSSOVER LIMBS,BS, C CODOMINANT
�� ROOT BALL DOESN'T SHIFT.
LEADERS, AND BROKEN DEAD
BRANCHES. INTERIOR TWIGS
cMULTI
V
AND LATERAL BRANCHES MAYBE
OR TAMPED SOIL.
NOT
FIR REMOVE; HOWEVER, ETERMINAL
BRANCH THE TERMINAL BUDS OF
Nn,Tn-
BRANCHES THAT EXTEND TO THE
05
EDGE OF THE CROWN.
Quercus ahurnardil
2 EACH TREE MUST BE PLANTED
3" ca., 12' ht., Fuii, Mafchln
SUCH THAT THE TRUNK FLARE IS
18
VISIBLE AT THE TOP OF THE ROOT
saidCypress
BALL. TREES WHERE THE TRUNK
PC
LI
FLARE IS NOT VISIBLE SHALL BE
Plstaohla chic -Is
L.U-troema indica
REJECTED. DONOTCOVERTHE
3" cm, i2' ht., Full. Matching
3" cal., 8'-8' ht.. 35 canes min., Full, Matched
TOP OF THE ROOT BALL WITH SOIL.
9
3. REMOVE ALL TWINE, ROPE, WIRE
Vilex
AND BURLAP FROM TOP HALF OF
ROOT BALL.
d. IF TIS HIPPED WIRE
I�
SH
BA KE AROUND
BASKET E BASKET IN FOU L. PLACE
FOUR PLACES
THE WIRE DOWN
C
I I
AND FOLD DOWN a' INTO PLANTING
HOLE.
DATE:
SET TOP OF ROOT BAU-1- TO T
ABOVE FINISHED GRADE.
(2•) MULCH LAVER ABOVE PREPARED SOIL.
MAINTAIN THE MULCH WEED -FREE FOR
A MIN. OF THREE YEARS AFTER
PLANTING.
3' HIGH EARTH SAUCER IN 5'
DIA. RING AROUND ROOT BALL.
WOOD STAKE, THREE PER TREE, SPACED
EQUALLY AROUND TREE. GUY WIRE SHALL
ALLOW SOME FLEXIBILITY OF TRUNK.
PROTECT TRUNK FROM GUY WIRE DAMAGE
WITH RUBBER COVER.
CRITICAL ROOT
ZONE AREA
Tn1 TREE PROTECTION DETAIL
u
O EXISTING TREES) TO REMAIN.
O DRIPLINE OF EXISTING TREE (TYP)
O CONTINUOUS NYLON TIE STRING
TIED TO STAKE TOPS W12'TUNDRA
WEIGHT ORANGE STREAMERS @ 3'
O.G.
O4 8METAL TSTAKES: Y O.C. MIN.,
DRIVEN 2' INTO GROUND AT (OR
OUTSIDE) TREE DRIPLINE
(D
-IN. MIN. HEIGHT ORANGE PLASTIC FENCING
INSTALLED PER MANF.
RECOMMENDATIONS(TYPL SUPPLEMENT
WI SILT FENCE FABRIC @ PRUNING
TRENCH AS REQ'D.
O EXISTING GRADE TO BE DISTURBED.
OT
SCOT PRUNING TRENCH -
OUTSIDE FENCE SEE NOTES,
O EXISTINGGRADE TO REMAIN.
SYMBOL
d s
/ -
�-TAMPS 11- WITH OOT ROOTBALLRASE
FIRMLY WITH FOOT PRESSURE SO THAT
COMMON NAME
-
�� ROOT BALL DOESN'T SHIFT.
PLACE ROOT BALL ON UNEXCAVATED
cMULTI
V
-TRUNK TREE PLANTING DETAIL
OR TAMPED SOIL.
Quercus N IBlana
Nn,Tn-
CRITICAL ROOT
ZONE AREA
Tn1 TREE PROTECTION DETAIL
u
O EXISTING TREES) TO REMAIN.
O DRIPLINE OF EXISTING TREE (TYP)
O CONTINUOUS NYLON TIE STRING
TIED TO STAKE TOPS W12'TUNDRA
WEIGHT ORANGE STREAMERS @ 3'
O.G.
O4 8METAL TSTAKES: Y O.C. MIN.,
DRIVEN 2' INTO GROUND AT (OR
OUTSIDE) TREE DRIPLINE
(D
-IN. MIN. HEIGHT ORANGE PLASTIC FENCING
INSTALLED PER MANF.
RECOMMENDATIONS(TYPL SUPPLEMENT
WI SILT FENCE FABRIC @ PRUNING
TRENCH AS REQ'D.
O EXISTING GRADE TO BE DISTURBED.
OT
SCOT PRUNING TRENCH -
OUTSIDE FENCE SEE NOTES,
O EXISTINGGRADE TO REMAIN.
SYMBOL
QUANTITY
BOTANICAL NAME
COMMON NAME
SPECIFICATION
TREES
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
QV
18
Quercus N IBlana
Lica Oak
3" cal., 12' ht Full, Matchln
05
13
Quercus ahurnardil
Taxa. Red Oak
3" ca., 12' ht., Fuii, Mafchln
TO
18
Taxodium Ssdchum
saidCypress
3" cd., 12' ht., Fuli, Matching
PC
LI
10
12
Plstaohla chic -Is
L.U-troema indica
Chinese Plstsche
Cape MyNa Natchez'
3" cm, i2' ht., Full. Matching
3" cal., 8'-8' ht.. 35 canes min., Full, Matched
21
9
Vitex agnus vastus
Vilex
13'.d., "'ht, 35 canes min., Full, Matched
CHAIRMAN
SHRUBS
O
DATE:
o
RI
32
Raphidepis indica
Indian HaWlhom Clara'
5 gal- 24" ht, 30" O.C., tdangularspacing
LF
18
Leuco h lum 5utecens
Texas Sae
5 gal.. 24" ht., 30" O.C., titan ulas .cin
C
23
lex comute burbldii nano
Dwarf Burord Holly
5 gal., 24" ht, 30" O.C., triangular spacing
ND
4
Naldina domesbca Fire Wer
Fire wer Nandnna
5 gal., 24" ht, 30" O.C., than ulara acin
PA
SG
5
3
Pennistetum alopecurddes'Hameln'
Salla greggii
Hameln Gass
Salvia Red'
1 gal. 17 min. ht 18" CLC, triangular spacing
1 gal 12" min, ht 24" O.C. Mangularspming
RR
13
Rosa'Rad-.
Knockoul Rose Red`
5 gat., 24" hL, 30" O.C., tnangularep-ing
GROUNDCOVER
TA
125
Tnchelospemlum asiaUcum I
Asian Jasmine
1 gal.. 24" O.C., loan lar spacing
LM
13
Lidope muscad'Vangated'
Vangated Linope
1 gal.. 18" O.C., indngUlar spacing
LAWN
Per Plan
Cynodon dactykm
Common Bennud.
Sod
STEEL EDGr'1G
Per Plan
4" steei edge to be bused 3" deep. Contractor to intall steel stakes at end of each
section ofedgaing.
DECOMPOSED
GRANfiE
Per Plan
3 natural color decomposed granite compacted With permease vreedmat.
S WLDER
Per Plan
3-0' 11, Mass Rock, bottom to be bused 3" below giade for stability
NOTES:
1. PERFORM ROOT PRUNING ON ALL EXISTING TREES TO REMAIN WHERE
CONSTRUCTION ACTIVITY FALLS WITHIN DRIP LINE OF EXISTING TREES.
ZR OT PRUNING METHOD: 2 MONTHS MIN. PRIOR TO EXCAVATION 8
CONSTRUCTION ACTIVITIES, HAND CUT ROOTS BY DIGGING A 18'-24' DEEP
a WWI ETRENCH ALONG THE OUTSIDE PERIMETER OF EXISTING TREE(S)
ADJACENTTOCONSTRUCTIONAREAS. MAXIMIZE PRUNING TRENCH
DISTANCE FROM TRUNK TO THE FULLEST EXTENT POSSIBLE. WI THE ROOT
PRUNING LINE PLACED Q THE EDGE OF CONSTRUCTION LIMITS.
•
® e
Know what's below.
Call before you dig.
(@ least 48 hours prior to digging)
0
J W
W_
ILL. ISJ (,
TJ Z
Uj
W 1--
Cy-1LLZ_ 0-
W �1-I U
a
Z Ln
W M (D
r1.
Y�
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER: CU -15-47
LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
8
S
CHAIRMAN
O
DATE:
o
w
SHEE'6. 4 OF 915
-
z
¢
a
APPROVAL DOESNOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES,
DEPARTMENT OF DEVELOPMENT SERVICES
K 1`T !q
Jj 2433 h
q>F
�
�P
oi- 11-`Z�1Ga
SHEET NO.
NOTE:
Al ar< dhturbed by "'w'cnon shall ce fine gad. and 11-bhhed by sod. These
1 1
�_ I I
areas shag. Irrlgakd and mai__ until permanent stand d gals Is achieved vMh a
mNhnum d 7WE coverage. Thus Is to IndNd an arena m cite uaa of euro done
property.
a
CONTINUOUS LIGHT LEVEL Spill @ Property Line
126 points
ALL FIXTURES TURNED ON HORIZONTAL FOOTCANDLES
N SPILL READINGS @ SOUTH REFLECT A SIGHTSCREEN Average 0.8
Maximum 3.0
Minimum 0.0
Pole
x-loc
y -IOC
height NARROW MEDIUM MEDIUMONARROWC
Total[20558
P10
-159
-166
901t
6
23
29
P11
159
166
90ft
6
23
29
P12
159
-166
90ft
6
23
29
PS
-320
-234
30ft
1 1
2
P6
-357
116.3
30ft
159 -166 90ft 6 23
-159 166 :Oft
6 23
24 92
2
2
P7
-54
571
30ft
46 46 44
3 3
6
P8
54
571
30ft
3 3
6
P9
-159
166
9011
6
23
29
Total
44
P9I
59 58
54
24
92 9 7
132
@tai- 0.1- e-Ne.t- 9.t r e.r eS-e.r 6.t--e:i- 9.i- a:r-0.� -0.+--Pr -0.a -0:i--0.+ -0+-&4 -0i di --or -0-1-ei -0-1-6.e--ofl-OO�I0
I P7 P8
b'
at
b
�aro-1-41 1 f
at .i. ' � ' • / •I � Iall
tl
I
it
I
DO a
1
at
I I
at 1
El,
/
coil/
t at
I
�1 0,2
12
Ell
_ _. ---------------- _ I
6 f 'ill \,\\��\\�\;\ �•i� :1i'i 14\ /
w\\..`� �i/!i/J li I\t \° \ oa3
l , I \\\ \ /j /// \ \ \ 0/5
012A�''V
�/•I 1vA - is ii A.
O12
�\• i 'v:glii;�U'�:-�i=\-�Q\�\iii,/
0,4
�1
Pi - 12
qI OI3
4 P5 ( uture) 1.R 2-0-2-2-45-2830-30-3.6-30-?�2-�r
qt I GOARANTITO POR THR RAT® llFE OF TI1R
Id.4 -0i 6x0.4 -0:2-&P -03 tea.^ -a? 2 ,,,\I ,m[{yN +/-IOT. of GGR'[ aK OF �>VEl POQi19 MAY VARY FROM
THIS INFORMATION IS CONFIDENTIAL AND P PIES IR Do. -D. HASID ON PROPER PREDICTIONS. UNIFOR1lITIES
TO QUALITE SPORTS LIGHTING, LLC AND IS NOT T DIS-UTION• VOLTAGE/ -3%. Pam GUARANTEED TO MEET THE IESNAS
EE REVEALED OR DISTRIBUTED TO OTHERS WITH0 T PLACEMENT AND IIOIRTFNG HEGHT WITHIN 3 RECOMMENDATIONS (UNIFSS SHOWN
FEET aP SPH'�
ECD IIICATION AND HEGHT.
I
PERMISSION OF QUALITE SPORTS LIGHTING, LLC 0 HIGHER DUE TO DESIGN CRITERIA).
USED IN ANV MANNER DETRIMENTAL TO THE INTE EST SEAND TANDARDB
fU COMPLY WITH CURRENT AA9HT0
OF QUALITE SPORTS LIGHTING, LLC
CONTINUOUS LIGHT LEVEL
P7�
,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI
F mYfa ,m 1U0111p0 ®IAT aYY,R® A
iHi Iv�eq.5* QWIOm®Al1d
NARROWO -- MEDIUM -
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
MEDIUMO NARROW
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
NARROW
UNIVERSAL SERIES V 1000W
MEDIUM
UNIVERSAL SERIES V 1000W
Pitching / Batting Area
24 points at z=3, sp 20ft by 20ft
HORIZONTAL FOOTCANDLES
Average 50
Maximum 67
Minimum 38
Avg: Min 1.32
Max: Min 1.76
Coef Var 0.18
UnifGrad 1.56
N
DR VIEW FRONT VIEW BACK
CRICKET GROUND LIGRT/NC
TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX
POELS P91
PIU, PN s FIX
: nBBwrTriru. ,I
ra SAT ASSXYBLLT.��M��Y�°
TDP VIEW
10 r PI-H-A'A"
/`r � ennrs
43
SIDE VIEW
nxu
m
T"
v
sua<am
wu mis
Li FAVML
FRONT VIEW BACK VIEW
CRICKET GROUND MORI G
TEXAS CNO)STF ACADE".. SOUTHLAEB. TX
ItlELS PT ! P6
HARDWARE LIST
2
5
5
67
8 THREADED ROD I 2 B
51
6' THREADED ROD 2 2 4�aTmeP�'e
I" BRACKET I 2 B
,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI
F mYfa ,m 1U0111p0 ®IAT aYY,R® A
iHi Iv�eq.5* QWIOm®Al1d
NARROWO -- MEDIUM -
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
MEDIUMO NARROW
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
NARROW
UNIVERSAL SERIES V 1000W
MEDIUM
UNIVERSAL SERIES V 1000W
Pitching / Batting Area
24 points at z=3, sp 20ft by 20ft
HORIZONTAL FOOTCANDLES
Average 50
Maximum 67
Minimum 38
Avg: Min 1.32
Max: Min 1.76
Coef Var 0.18
UnifGrad 1.56
N
DR VIEW FRONT VIEW BACK
CRICKET GROUND LIGRT/NC
TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX
POELS P91
PIU, PN s FIX
: nBBwrTriru. ,I
ra SAT ASSXYBLLT.��M��Y�°
TDP VIEW
10 r PI-H-A'A"
/`r � ennrs
43
SIDE VIEW
nxu
m
T"
v
sua<am
wu mis
Li FAVML
FRONT VIEW BACK VIEW
CRICKET GROUND MORI G
TEXAS CNO)STF ACADE".. SOUTHLAEB. TX
ItlELS PT ! P6
HARDWARE LIST
9
42-
51
67
8 THREADED ROD I 2 B
5
J
6' THREADED ROD 2 2 4�aTmeP�'e
I" BRACKET I 2 B
,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI
F mYfa ,m 1U0111p0 ®IAT aYY,R® A
iHi Iv�eq.5* QWIOm®Al1d
NARROWO -- MEDIUM -
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
MEDIUMO NARROW
UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW
NARROW
UNIVERSAL SERIES V 1000W
MEDIUM
UNIVERSAL SERIES V 1000W
Pitching / Batting Area
24 points at z=3, sp 20ft by 20ft
HORIZONTAL FOOTCANDLES
Average 50
Maximum 67
Minimum 38
Avg: Min 1.32
Max: Min 1.76
Coef Var 0.18
UnifGrad 1.56
N
DR VIEW FRONT VIEW BACK
CRICKET GROUND LIGRT/NC
TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX
POELS P91
PIU, PN s FIX
: nBBwrTriru. ,I
ra SAT ASSXYBLLT.��M��Y�°
TDP VIEW
10 r PI-H-A'A"
/`r � ennrs
QUALITE
215 W. MECHANIC ST.
HILLSDALE, MI 49242
CASE NUMBER:CU-15-47
LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION.
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET: 5 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
SPORTS LIGHTING, LL(
PHONE:517/439-1581
FAX:517/439-1194
800/933-9741
12/7/2015 1 QL-17049D22=.IG
CRICKET GROUND LIGHTING
TEXAS CRICKET ACADEMY, GRAPEVINE, TX
TWS I SCALE=1 1 II -17-15
SIDE VIEW
nxu
m
T"
v
sua<am
wu mis
Li FAVML
FRONT VIEW BACK VIEW
CRICKET GROUND MORI G
TEXAS CNO)STF ACADE".. SOUTHLAEB. TX
ItlELS PT ! P6
HARDWARE LIST
�nBwN.T
,>B rxar CVNACOwrfaxs
TOAb'SEYBOJtS.
rmnore mB TOP "I,
f1ue,BeB eon
-�
HARDWARE ID. L
DESCRIPTIONTY.TY. TAL
8 THREADED ROD I 2 B
6' THREADED ROD 2 2 4�aTmeP�'e
I" BRACKET I 2 B
618' CALV. NUT 12 2 24
Pde
6 B' GAL L ASNER 12 E 2I
Total
kN
314 4, S.S. TH. ROD 2 2 4
CONTINUOUS
0* LOCK-►ASHEF 2 2 4
LIGHT
LEVEL
314- FLAT-IASHER 4 2 B
-159 -168 90ft 6 23
159 166 Sort 6 23
29
29
S 4: S.S. NUT 4 Y B
' M!( BBLT B IB
OWNIA N B 2 IB
B" S.S. LOGE IASHER B 2 TB
Li 2- NIPPLE PKC Y1 2 1 f
QUALITE
215 W. MECHANIC ST.
HILLSDALE, MI 49242
CASE NUMBER:CU-15-47
LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION.
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET: 5 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
SPORTS LIGHTING, LL(
PHONE:517/439-1581
FAX:517/439-1194
800/933-9741
12/7/2015 1 QL-17049D22=.IG
CRICKET GROUND LIGHTING
TEXAS CRICKET ACADEMY, GRAPEVINE, TX
TWS I SCALE=1 1 II -17-15
Pde
a -lac NARROW MEDIUM
Total
kN
CONTINUOUS
LIGHT
LEVEL
'to
Pit
-159 -168 90ft 6 23
159 166 Sort 6 23
29
29
47.1
47.1
P12
P9
Total
159 -166 90ft 6 23
-159 166 :Oft
6 23
24 92
29
29
116
47.1
47.1
188.5
44
46
46 46 44
MEDIUM
UNIVERSAL SERIES V 150OW
44
P9I
59 58
54
53 54 58
59 44
I'll
NARROW
53 54
55 53
54
54 54 53
55 54
53
UNIVERSAL SERIES V 150OW
47 56 56
55 52
53
3 52
55 56
56
47
47 57 54
50 0
53
55 53
50 54
57
47
54 56 52
5 54
53
54 53 54
0 52
56
54 5
51 57 52 52
1 55
5RIEUEM 55
1 52
52
57 51
46 53 52 53
53
53
53
52
53 46
CRICKET FIELD
51 57 52 52
1 55
55
1 52
62
57 s1
177 points at z=3, sp 30ft
HORIZONTAL FOOTCANDLES
by
30ft
Average 53
3 54 56 52
5 54
53
54 53 54
52
56
54
Maximum 59
Minimum 44
47 57 54
50 0
53
55 53
50 54
57
47
Avg: Min 1.20
Max: Min 1.34
Var 0.06
47 56 56
55 52
53COef
53 52
55 56
58
47
UnifGrad 1.34
53 54
55 53
54
54 54 53
55 54
53
Pilo 44
59 58
54
53 54 58
59 44
P12
44
46
46 46 44
avtWriA _
�
90111WLL Fa91>s
YAT 9ANY TROY
T� �� m
n
a01YN®A
I�mt �Ab
1.a m7Eats1
ai��
n� o
OCtlamIWIDA 1aNMa BBaTII
BO®1 DNR A �R 4LI®Al.
QUALITE
215 W. MECHANIC ST.
HILLSDALE, MI 49242
CASE NUMBER:CU-15-47
LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION.
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET: 5 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
SPORTS LIGHTING, LL(
PHONE:517/439-1581
FAX:517/439-1194
800/933-9741
12/7/2015 1 QL-17049D22=.IG
CRICKET GROUND LIGHTING
TEXAS CRICKET ACADEMY, GRAPEVINE, TX
TWS I SCALE=1 1 II -17-15
- Ll.i H, I'I_ AN
TL�.�..,�
� 4
1 -
Br
1— 1V FUUI Br are. Btl
b F. -Callon
i
Foundation Slab
Texas Cricket Academy
1 I
j
I
T.--1. A°aoBmy
rr�B21M
�/ FOUNDATION PLAN
L
B B' 1 EEtltESESII °X-�X.i W C£fER.SEREEtl
DUNPBTEB B.
_._- ............._.-._._.
la
Daa�Bam, s«.a�
E Gates
F_EN6E SEE-
TI°N IRI YBD1.E W
B WIDE {
i
I
z xo..EB EaBTku.x rExcE>I«B,s 9 EE�cB.xxEi To ^4O2-Dx e6 —EL EUBT
FENCE DETAIL
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER:CU-15-47
LOCATION:3451 FOxFIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET. 6 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
LLJ
U)
D
0
LLJ
0
U
LLJ
\�� z
� � z
W W �
�Q Q Q
UU
Q <
\/ O
LL LL X z
00~ Q
L
z o
o
LLQ LLJ /W LJ�
y y a- J
UUQ
-Wi CL� CL�
K U U =
\J
a rn
REVISIONS
REV. DATE: BY
SHEET NO.
XX
7
26 gouge Standing Ridge
b
colored Metal Roofing
James Hardie
Fiber Cement
Jamea Hartlle
/ Sl Eing
Fiber Camenl
Garage Door
siarn
M^\ Door _
a x 14 xac o'. 3 0x6-6 stone Veneer
/
Rear Eleval'Dn
Texas Cricket Academy
la a'r
}=•'r �, r3at Iia
\
LED Llghta
LED Lightd
a -,Ips:. to
I 1
a a
•s ° a Metal Enteranca
stone Venae
F
-_ Door-St—V.—,
Front Elevation
Texas Cricket Academy
26 gauge Standing "dge
colored Metal Roofing Jamea Hardie
Fiber Cement
JemesH
Fiber Com a, and
/ /Siding
siding
7
LED Li /'-ght.� v
b
LED Lights
1'i I/tlll�`JJ
Garage Door
st a Veneer
M^\ Door _
a x 14 xac o'. 3 0x6-6 stone Veneer
J
Rear Eleval'Dn
Texas Cricket Academy
Texas Cricket Academy
a -,Ips:. to
j
26 Hauge Standing Ridge
oolbred MCI Roorinq
Jamea Hardie
Fiber came
samgm
Jem ea Herdie
Fiber Cement 26 9aa90 Stantling Ridge
Sltll q colored —.1 Awning
10'x10'
LED Ligbta/ . I •a. •xa x I — .. -,�
LED Llghta— I'
stone veneer Stone Veneer '
South Side Elevation
Texas Cricket Academy ••slam91. Jam a. Haraie
Finer camera abam ane
s )5X or eell0ing.
James Hartlie
26 yaoSt—mg Ruga Fiber Cement
wl9r9d Metal avandv -i-
29 gauge —d- Ling RidgeNorth Cide Flevati on
colored Metal Awning Texas Cricks t Academy
t9•xta•
-Ti ae Cdekef Academy
Rad Mlau LK 9)a-a:l ))ml
CASE NAME: GRAPEVINE CRICKET FIELDS
CASE NUMBER: CU -15-47
LOCATION:3451 FOXFIRE LANE; LOT i BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET 7 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
W
U)
7)
0
w
0
rI
V I
L�yL
WW
Q�
U U
Q Q
cn
X
00 ~ O
0- El- Q
z >
j �
wwW w
y Y- n w
UUQ
CL� c w
K U U _
6. N
REVISIONS
REV. DATE: ey
SHEET NO. X
X/
f ==Al- INFO�=/M N onu
__ wEPLn�ml� --_.— PND srFiL z,acn _.
NMECTpNPIATE9 TE, 6Y'ixlcx
aussEr _.._-__. TE. irrrx�cx
___ IxATEl DRDL
L c
wL_V. PND. sr
RcxaP eacl L oP o �
--- Pcnai 1 ean1. Du PxD s EiL
TEE m:
a ,a
A1,1
e. D
E
__. vEArcu iaoulyoEDl _ —CK
DEDsrw PEaDE rr,s.,
F
- NCE eoL I )
_..SUONr -_--.
TRIP-
_-. C,BIE COIM.EC1ron RATe TE vte
IwCJtLE... KLE - -_
N
m,ENDUE -IIT
-..-TRPEnoEn s.TUOS '.STEEL vurE,,rz'
DETAIL LOCATION CALLOUTS
T080HKMF001120
80x120 HKM TRUSS FRAME
IN
(Ail ...... _............
-.-COVER SHEET
IB11 ......._....
_-...GENERALNOTES
IC11
..............BUILDING PIAN VIEW
ID11 ......
MATERIALSPECIFICATIONS
IE1I .. ..
RAFTER PROFILES
IF17
SIDE PROFESS
[G11 ..
.DETAIL LOCATIONS 8 BASE DETAILS
IG21 ..
._SPLICE CONNECTION DETAILS
IG31 .....
...BRACE CONNECTION—MLS
MAI .. ..
C LE LAYOUT S DETAILS
Mi] .._......
...SASE PUTS UVOUTBS
IHTI .............
... ...FWNDATON DETAILS (ANCHORAGE)
NAI ....
...BUILDING REACTION DATA
IN
......OMITTED
Ti�
IL1 L])...
...FRONTENDWALL—HKF.110
IM 1- M21 ..........
AMI �
TTED. BACK ENDWALL OPEN
lail v�x�i-AxrnEDePxCEcanEcxox � a.*`'�
��ox�v'rtew, snlcE sibinEaxai i°sE
F,EPaxo E �E� „
rcsB..�F..BmR DwEsacElsEaNExrrosESNExn /�
I�NVE�wsEu R.,ND,�Ecax,�DroxP.Dl� .
Ia1vlrE�wB Bu,EPnt BPacEcaxxEc,gx B.ql ' / ,
I�Pw�H�rEBIBaPPaPre.BEraBEaI,ExP� � 9
«,a Icnvre""wd°'BensE rD wPPOPTBnsEmxxecTwx� �`%
IG,1�3 wiucx mnrEwxuecrax,swoeuvsLEl '
[Gil VIEW 1 -NOT USED
OR
920.14— aN BED'a W±RX
s)2
�i" S
!y<xexN:i IWME
I.
HDB,B PLS _
\\
[Gil VIEW 2- BASE
pTO SUPPORT BASE CONNECTION
(uli2xui _ � wNOI
[G71 VIEW 3 - WINCH PLATE
CONNECTION (IF APPLICABLE) .
=M7, E,FA/M.irRCxlLpe.VgNles/ nw3 .t e v mncca+¢41cEN,ix,xEurFsieDRlw1 C£
w�fnfzarED B'EBwvemucvnE �, Tai �..ivnx®siEEL. BPacsssEsaWFmgcncEs
9LBLSELDEDJ: ,us PePEaWEn ev cTPnFlEn wEimis
IDI 7
NI
E 111D
=MM IM
FRneNC Gaal aN .wFAs w,mwvnPEHwsl. suPFncUTAsr BEaEaxaxsaL FPEE
CTaFu �DrmuxD uPEiavl•ox'siFivanaxawnrEPws. c°naixlxsum FanNcnrxw.wD ."fwEhnsvmvlmLer wvnuHw�o roxurowiD wn�.w°wunP[o
gxBa.s P N . roBxa N�raPE D
iP p
PN WHINrNE s,xVciVPE EPECTxM. '_S_iaolxwxw ^PDPCE'P[55,—acaa4UaBAI,YFro
src°PP e. m ss. ane,N!cn DPnDEw DP EWUFDP c=_rxav she N,nE war(�'siPunaP4
no El.1.112 o(.muAeDl WxxEc° ilaxv:T ixEvmetEvusPwua,
j�l. fN°F H.
°6P BN�wPE a. TMF �•BP Df,w x W xaro P. a awP xDPeEP
Grp=. P ExaDl ,,BP E,E<naP M H,BEEL MUII°m61
Nmsa'o`i'.-:ixg puxc-oP-,.e I:auLRG�
enwe®Feec
a` : —MI—d
d sko- D w1
rxw. ,xwi�s"�N0 wEwEorPw sPm s/A«oP lnm:i."•n�celr.o.w,coro.,.Dx InB�,PnAwx,.xD
eem.. rlaln=xEnuNEBulmxL,.•-..BnaBEVErncr<au,Nx.
Bx¢:T cZw FrernE BNpxc
z. arenros rEBPRI EDPaxcxaxceslw
L. --T
B - LATERAL BRACE (SKU: LB3%NSTLIN)
AB ANGlEO BRACE (SKU: ASa'A1MNLIN)
TAB ANGLED BRACE ISKU: AB]SGIMNLIN)
SPLICE: SEE DETAIL SHEET IG31
j .PINE
O `–o<.mP661,EE. P1BNxx.N»EB ` j / ,�
`i
L7
ePab [EI] VIEW 1 - FRONT PROFILE (END RAFTER) e
IETI VIEW 2 - FRONT PROFILE (MID RAFTER)
LB -LATERAL BRACE BAY (SKU: LB35GUSTL1N)
SPLICE: SEE DETAIL SHEET 1.31
- Ifi%IBNx1'lEl: enc°PurER t �PFDcI � °EPI^h PH,Bx�xaPeafl .
R4
IW M1%PiEx BOev, BEoxErO Rro \ xx[ '), � Fjt�'�i
�� RNmMc4BCf\ n„ x .
>: of w m .,,• xPw� 'F aala malA�;a
_ _. `.� `�N,ncEPv,TEln,oaatcPBDFI ro,E.ea.s,Ps,awwx '�
[GRI VIEW 1 F BRACE PLATES jjG2 VIEW 2' BRACE PLATES [4321 WEW 3 -MIDDLE SPLICE
(SSEGMENT 70 SEGMENT) (SU�PORT BASE TO SEGMENT) (SSEGMENT TO SEGMENT)
�,ax xaT +tr
.a'-. �_Wlvrx�nExaa.vlc Dl%E tB�`lt ..w reau ew,a xa,El„eNT Y$ Pu,EDtmS
gri-w}I Pnn:Pa�xn_o.E�
eNEx lErol r� I aN °„w3; aE a ro K �DEj'a""P,xP B Aea
--- x�P�,ExaxaPD TRNN.I I
54321 VIEW 4- END SPLICE [G2] VIEW 5- LATERAL BRACE
S GYENT TO SEGMENT) CONNECTION (END) IG2I VIEW 6 -LATERAL BRACE
PurEP CONNECTION (MID)
Ixlva+*InEN,�/.. ISD Beate a*EPSEaNEBw.rSMce wrry P
/� ,Ero PN,EPc„aPe '" pm Pa.hP�xax - PxaPaH�®wx�r
N,, _ NEx.lwDl � oes,Iarx xF omP.l
.mxµ,Eea,oP� :I;zS 17 aDro cPOPo sEexEPi-_ roa oDxO ,Bw HOx.aeLEI
[4321 VIEW 7- ANGLED BRACE CONNECTION [G2I VIEW B- U43OLT BRACE CONNECTION ((G22I1VIEW B- SIDE DOOR
OF APPLICABLE) bE1'AIL (IF APPUCABLEI
LEFT SIDE -SEE SHEET IF11 FOR ELEVATION VIEW
P :Ma
1 RIGHT SIDE - SEE SHEET IFII FOR ELEVATION VEIN I ISMIT ' -
--
L,
Erecting the Truss Frame
CASE NAME' GRAPEVINE CRICKET FIELDS
CASE NUMBER. CU -15-47
LOCATION:3451 FOXFIRE LANE: LOT 1BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE.
STET 8 OF 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
80'x120' TENT
STRUCTURE
aErtaTsroN�ruvcRrz sn[oF4 MCEss rgiEO i F .•
D�FEm%TF ax TYPIrwLGMF s=+.we
rnxFlsxml asxrwenv rvuuecxcrvm OsrtonTlwtF - o -i ___ SR
F E �___�� Ix RenEnexwo
[G3I VIEW 2 -TYPICAL CABLE
F- CONNECTION DETAIL
EFT fD,IFaReeYMAMERN. A
aEFE l,.-w•TtwxEu.—TH MME
creLE r'
ur v nAx
x x m x,me ru 1m xic,mo. �... Tt0'G^BlE SIEEYE
[G3I VIEW T- CABLE SKU PER SPAN- -_- tzuac 1 /r'zcrac*HIrotE
[G3]VIEW 3-
(- --- CABLEASSE"I,
! / STD ^moo=__
�,/ �nTTxESE UTFwu etuCEs� `` � I vM TrMaE /
n
�w
ICfI—BAY—SE ., to stwxL[fD'Pl__ >'t —
Inrz.
x.� UTERUS
(G31 VIEW 4- SWAY CABLE LOCATIONS [G31 MEW 5- SWAY CABLE DETAILS IG3I CAB LE TYPICAL SWAY
FOUNDATION NOTES:
ESAPCD DOES NDT PRONDE ANY IMTERIAL OR OESIGN CRITERIA FORTHE CREATNIN
OF THE FOUNWTgN OF THIS WILDING, UNLESS OTHERWISE NOTED,
SDU�ND�ATIIO�N S� BBERENGINEERED ANDAPPROVED BY A LICENSED
FOUNDATION MUST MEET THE BUILDING REACTION DATA6HOWN BELOW.
SEE ENDY-L DRAWINGS FOR ENO—L REACTIONS (IF APPUCASLE)
oommmm �m��
m
Cm==®��
o===®®®m �.w��1
A WPT004WS DETAILS (IF APPLICABLE)
(
1 _rte r tsa.IF,Rx:wEw
.. Io
I�
BPO62M DETAILS
�� rz uFEa
,+'au�sE,Fa>ww. EH.en AMx�a
c� xeaN'•I
OJNRFYrvE 9r nEiE �f•i F
I �ErowuF � 14r
LF �J w.LE
GASE NUMBER:CUe'Se47munel neI_w
LOCATION:3451 FO%FIRE LANE; LOT 1 BLOCK 1
GRAPEVINE CRICKET FIELDS ADDITION
MAYOR SECRETARY
DATE:
PLANNING AND ZONING COMMISSION
CHAIRMAN
DATE:
SHEET 9 Of 9
APPROVAL DOES NOT AUTHORIZE ANY WORK
IN CONFLICT WITH ANY CODES OR
ORDINANCES.
DEPARTMENT OF DEVELOPMENT SERVICES
80'x120' TENT