Loading...
HomeMy WebLinkAboutItem 04 - CU15-47 Grapevine Cricket FieldsTO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE PLANNING AND ZONING COMMISSION FROM: BRUNO RUMBELOW, CITY MANAGER SCOTT WILLIAMS, DEVELOPMENT SERVICES DIRECTOR MEETING DATE: JANAURY 19, 2016 SUBJECT: DEVELOPMENT SERVICES TECHNICAL REPORT OF CONDITIONAL USE APPLICATION CU15-47 GRAPEVINE CRICKET FIELDS APPLICANT: Thiru Kumaran PROPERTY LOCATION AND SIZE: The subject property is addressed as 3451 Foxfire Lane and is proposed to be platted Lot 1, Block 1, Grapevine Cricket Fields Addition. The site contains approximately 20 acres and has approximately 1,752 feet of frontage along Foxfire Lane. REQUESTED CONDITIONAL USE AND COMMENTS: The applicant is requesting a Conditional Use Permit to allow for stadium lighting and to exceed the maximum permitted height of a tent/canopy structure in coniunction with a cricket field complex on approximately 20 acres. In the fall of 2000 a zone change request was approved on the subject site and surrounding 63.2 acres along Foxfire Lane rezoning the property from "R-20" Single Family District to "RA" Recreational/Amusement District. In the fall of 2015, staff approved administratively a site plan for an outdoor cricket facility which included three cricket fields, a wicket practice area and a 1,600 square foot men's/women's dressing room and storage building, covered viewing area, and associated parking. With this request, the applicant \ZCU\CU15-48.4 1 January 14, 2016 (9:17AM) proposes to illuminate one of the cricket fields (the southernmost of the three) with four stadium lights which are 90 -feet in height; a wicket practice area along the northern property boundary will also be illuminated by four light standards that are 30 -feet in height. In lieu of bleacher seating, a 9,600 square foot tent/canopy that can accommodate 450 spectators will be located within the center of the three practice fields. This canopy is 38 - feet in height which exceeds by three feet the maximum permitted height of 35 -feet. With approval of a conditional use permit, the 38 -foot canopy height may be allowed. Lighting levels at the southwest, west and northwest property lines adjacent to the residential zoning meet the allowed lighting levels of 0.2 footcandles. The total parking provided is 98 spaces -95 spaces are required. At some point in the future the applicant plans to add 16 additional parking spaces providing a total of 114 spaces on site. No parking signs will be permanently installed along Foxfire Lane to discourage parking on the street. PRESENT ZONING AND USE: The property is currently zoned "RA" Recreational Amusement District and is undeveloped. HISTORY OF TRACT AND SURROUNDING AREA: The subject property was annexed into the City of Grapevine as part of an approximate 300 acre annexation from the City of Southlake and the Corps of Engineers which was approved by Council on November 2, 1993 (Ord. 1993-49). This property received the "R- 20" Single Family Designation upon annexation. Some of the property is unplatted and vacant with some single-family homes and Lonesome Dove Ranch. Property to the northwest received Zone Change Case Z01-01 (Ord. 2001-13) approved on February 20, 2001, changing the site zoning to "R-5.0" Zero Lot Line District with deed restrictions requiring all on site development to comply with the regulations of "R-7.5" Single Family District. Zone Change Z99-22 (Ord. 2000-113) and Conditional Use Permit C000-54 (Ord. 2000-121) were approved on November 7, 2000, changing the zoning on the subject property to from "R-20", Single Family District to "RA" Recreation/Amusement District and approving a conditional use permit for on -premise consumption of alcoholic beverages (beer, wine and mixed drinks) in conjunction with the operation of an existing recreation/amusement based business (Ranch of Lonesome Dove). SURROUNDING ZONING AND EXISTING LAND USE: NORTH: "RA", Recreational/Amusement District and "R-7.5" Single Family District, Lonesome Dove and Lakeview Estates SOUTH: "RA", Recreational/Amusement District and "R-12.5" Single Family District undeveloped and Cannon Homestead EAST: "RA", Recreation/Amusement District – Ranch of Lonesome Dove \ZCU\CU15-48.4 2 January 14, 2016 (9:17AM) WEST: "R-20", Single Family District — unplatted single family homes AIRPORT IMPACT: The subject tract is not located within any of the noise zones as defined on the "Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map. MASTER PLAN APPLICATION: The Master Plan designates the subject site as Recreational Amusement. The proposed development does comply with the Recreational/Amusement designation. THOROUGHFARE PLAN APPLICATION: Foxfire Lane is not list on the Thoroughfare Plan. /at \ZCU\CU15-48.4 3 January 14, 2016 (9:17AM) TR IA1A 22.295 AC A ' I, 90'"'1 TR TR GO P-1) 1 1P6B 1 B6 r swe TRACTA 6 OOMMON AREA 3 dS s . �0 -20 12! 17 13 1 16 10.955 @ 0 16 i 19 ? -12.5 1 1B j 20 1.00 @ 13.699@ Feet 0 150 300 450 600 Date Prepared: 12/31/2015 U � TR 1 4.25 AC TR IA7 TR 1A1 5.33 AC TR 1D 2.04 AC TR 1C2 10.803 AC TR 1G 25.6334 @ CU1 5-47 Grapevine Cricket Fields This data has been compiled by the City of Grapevine IT/GIS department. Various official and unofficial sources were used to gather this information. Every effort was made to ensure the accuracy of this data. however, no guarantee is given or implied as to the accuracy of said dela. TR 1G 25.6334 @ CUFD--Ln UV CITY OF GRAPEVINE CONDITIONAL USE APPLICATION Form 66A„ PART 1. APPLICANT INFORMATION Name of applicant/ agent:/company/contact Thiru Kumaran Street address of applicant/ agent: 217 Creekside Lane City/ State /Zip Code of applicant / agent: Coppell, TX 75019 Telephone number of applicant/ agent: Fax number of applicant/agent (512) 468-1711 Email address of applicant/agent Mobile phone number of applicant/agent PART 2. PROPERTY INFORMATION Street address of subject property 3420 Foxfire Lane Legal description of subject property (metes & bounds must be described on 8 1/2"x 11"sheet) Lot 1 Block 1 Addition Grapevine Cricket Fields Addition Size of subject property 18.929 Acres 824,535 Square footage Present zoning classification: Proposed use of the property: RA Cricket Fields Circle yes or no, if applies to this application Outdoor speakers Yes No Minimum / maximum district size for conditional use request., Minimum lot size 8,000 sq. ft. Zoning ordinance provision requiring a conditional use: Section 30 PART 3. PROPERTY OWNER INFORMATION Name of current property owner. Texas Cricket Academy Street address of property owner: 217 Creekside Lane City / State / Zip Code of property owner: Coppell, TX 75019 Telephone number of property owner: Fax number of property owner.- wner.(512) (512)468-1711 utt5 --q -1 ❑ Submit a letter describing the proposed conditional use and note the request on the site plan document ❑ In the same letter, describe or show on the site plan, and conditional requirements or conditions imposed upon the particular conditional use by applicable district regulations (example: buffer yards, distance between users) ❑ in the same letter, describe whether the proposed conditional use will, or will not cause substantial harm to the value, use, or enjoyment of other property in the neighborhood. Also, describe how the proposed conditional use will add to the value, use or enjoyment of other property in the neighborhood. ❑ Application of site plan approval (Section 47, see attached Form `B'). ❑ The site plan submission shall meet the requirements of Section 47, Site Plan Requirements. ❑ All conditional use and conditional use applications are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date. ❑ All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled. ❑ Any changes to a site plan (no matter how minor or major) approved with a conditional use or conditional use permit can only be approved by city council through the public hearing process. ❑ I have read and understand all the requirements as set forth by the application for conditional use or conditional use permit and acknowled a that all requirements of this a lication have been met at the time of submittal. PART 4. SIGNATURE TO AUTHORIZE CONDITIONAL US REQUEST AND PLACE A CONDITIONAL USE REQUEST SIGN ON THE SUBJECT PROPER' Thiru Kumaran Print Applicant's Name: The State of County Of Before Me W ! t 1 � i' C on this day personally appeared t��Oynoci (notary) (applicant) known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein expressed. (Seal) Given under my hand and seal of office this day of De A.D. 'ZZ (, 4 t pug JULtETA CORTE Notary Public STATE OF TEXAS r 10-12-16 Notary I�tAnd For State Of Tex s..." 4 5 s Fly cosmn Exp. Thiru Kumaran Print Property Owners Name: `-t � The State Of 1 C,Is CountyOf i, C i c'� -ThBefore Me �)1A`\6 G� on this day personally appeared I (notary) (property owner) known to me (or proved to me on the oath of card or other document) to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that he executed the same for the purposes and consideration therein�expressed. 7,0 (Seal) Given under my hand and seal of office this c� day of i `e d'y\b—r Y' p. rp� JULIE`I°A CORTE Notary Public Notary In nd For State Of Texas STATE OF TEXAS r � =V My Corrrn, Exp. 10-12-16 DEC 8 2015 d ct�r�L-LO IMMM4491c] All Conditional Use and Special Use Applications are assumed to be complete when filed and will be placed on the agenda for public hearing at the discretion of the staff. Based on the size of the agenda, your application may be scheduled to a later date. All public hearings will be opened and testimony given by applicants and interested citizenry. Public hearings may be continued to the next public hearing. Public hearings will not be tabled. Any changes to a site plan (no matter how minor or major) approved with a conditional use or a special use permit can only be approved by city council through the public hearing process. Any application for a change in zoning or for an amendment to the zoning ordinance shall have, from the date of submittal, a period of four months to request and be scheduled on an agenda before the Planning and Zoning Commission and City Council. If after said period of four months an application has not been scheduled before the Commission and Council said application shall be considered withdrawn, with forfeiture of all filing fees. The application, along with the required filing fee may be resubmitted any time thereafter for reconsideration. Delays in scheduling applications before the Planning and Zoning Commission and City Council created by city staff shall not be considered 2 part of the four month period. I have read and understand all of the requirements as set forth by the application for conditional use or special use permit and acknowledge that all requirements of this application have been met at the time of submittal. Signature of Applicant Date: 1)- 16 T I Signature of Owner CL/"� Date: AN ORDINANCE ISSUING A CONDITIONAL USE PERMIT IN ACCORDANCE WITH SECTION 48 OF ORDINANCE NO. 82-73, THE COMPREHENSIVE ZONING ORDINANCE OF THE CITY OF GRAPEVINE, TEXAS, SAME BEING ALSO KNOWN AS APPENDIX "D" OF THE CITY CODE, BY GRANTING CONDITIONAL USE PERMIT CU15-47 FOR STADIUM LIGHTING AND TO EXCEED THE MAXIMUM PERMITTED HEIGHT OF A TENT/CANOPY IN A DISTRICT ZONED "RA" RECREATION/AMUSEMENT DISTRICT ALL IN ACCORDANCE WITH A SITE PLAN APPROVED PURSUANT TO SECTION 47 OF ORDINANCE NO. 82-73 AND ALL OTHER CONDITIONS, RESTRICTIONS AND SAFEGUARDS IMPOSED HEREIN; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; PROVIDING A CLAUSE RELATING TO SEVERABILITY; DETERMINING THAT THE PUBLIC INTERESTS, MORALS AND GENERAL WELFARE DEMAND THE ISSUANCE OF THIS CONDITIONAL USE PERMIT; PROVIDING A PENALTY NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00); DECLARING AN EMERGENCY AND PROVIDING AN EFFECTIVE DATE q1s-Y17 Ga"6-01/16 CR ►cke7- F/ELD3 WHEREAS, an application was made requesting issuance of a conditional use permit by making applications for same with the Planning and Zoning Commission of the City of Grapevine, Texas, as required by State statutes and the zoning ordinance of the City of Grapevine, Texas, and all the legal requirements, conditions and prerequisites having been complied with, the case having come before the City Council of the City of Grapevine, Texas, after all legal notices requirements, conditions and prerequisites having been complied with; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied: safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the site; safety from fire hazards and measures for fire control; protection of adjacent property from flood or water damages, noise producing elements, and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting, and types of signs and relation of signs to traffic control and adjacent property; street size and adequacy of width for traffic reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off-street parking facilities; location of ingress and egress points for parking and off-street locating spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health and the general welfare; effect on light and air; the effect on the overcrowding of the land; the effect on the concentration of population; the effect on the transportation, water, sewerage, schools, parks and other facilities; and WHEREAS, the City Council of the City of Grapevine, Texas, at a public hearing called by the City Council of the City of Grapevine, Texas, did consider the following factors in making a determination as to whether this requested conditional use permit should be granted or denied; effect on the congestion of the streets, the fire hazards, panics and other dangers possibly present in the securing of safety from same, the effect on the promotion of health and the general welfare, effect on adequate light and air, the effect on the overcrowding of the land, the effect on the concentration of population, the effect on the transportation, water, sewerage, schools, parks and other public facilities; and WHEREAS, all of the requirements of Section 48 of Ordinance No. 82-73 have been satisfied by the submission of evidence at a public hearing; and WHEREAS, the City Council further considered among other things the character of the existing zoning district and its peculiar suitability for particular uses and with the view to conserve the value of buildings and encourage the most appropriate use of land throughout this City; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that there is a public necessity for the granting of this conditional use permit, that the public demands it, that the public interest clearly requires the amendment, that the zoning changes do not unreasonably invade the rights of those who bought or improved property with reference to the classification which existed at the time their original investment was made; and WHEREAS, the City Council of the City of Grapevine, Texas, does find that the conditional use permit lessens the congestion in the streets, helps secure safety from fire, panic and other dangers, prevents the overcrowding of land, avoids undue concentration of population, facilitates the adequate provisions of transportation, water, sewerage, schools, parks and other public requirements; and WHEREAS, the City Council of the City of Grapevine, Texas, has determined that there is a necessity and need for this conditional use permit and has also found and determined that there has been a change in the conditions of the property surrounding and in close proximity to the property requested for a change since this property was originally classified and, therefore, feels that the issuance of this conditional use permit for the particular piece of property is needed, is called for, and is in the best interest of the public at large, the citizens of the City of Grapevine, Texas, and helps promote the general health, safety and welfare of this community. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS: ORD. NO. 2 Section 1. That the City does hereby issue a conditional use permit in accordance with Section 48 of Ordinance No. 82-73, the Comprehensive Zoning Ordinance of the City of Grapevine, Texas, same being also known as Appendix "D" of the City Code, by granting Conditional Use Permit CU15-47 to allow for stadium lighting and to exceed the maximum permitted height of a tent/canopy structure in conjunction with a cricket field complex on approximately 20 acres (Grapevine Cricket Fields) in a district zoned "RA" Recreation/Amusement District within the following described property: proposed to be platted as Lot 1, Block 1, Grapevine Cricket Fields Addition (3451 Foxfire Lane) all in accordance with a site plan approved pursuant to Section 47 of Ordinance No. 82-73, attached hereto and made a part hereof as Exhibit "A", and all other conditions, restrictions, and safeguards imposed herein, including but not limited to the following: None. Section 2. That the City Manager is hereby directed to amend the official zoning map of the City of Grapevine, Texas, to reflect the herein conditional use permit. Section 3. That in all other respects the use of the tract or tracts of land herein above described shall be subject to all the applicable regulations contained in said City of Grapevine zoning ordinance and all other applicable and pertinent ordinances of the City of Grapevine, Texas. Section 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting health, safety, morals and the general welfare of the community. They have been designed with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets; to secure safely from fire, panic, flood and other dangers; provide adequate light and air; to prevent overcrowding of land, to avoid undue concentration of population; facilitate the adequate provisions of transportation, water, sewerage, drainage and surface water, parks and other public requirements, and to make adequate provisions for the normal business, commercial needs and development of the community. They have been made with reasonable consideration, among other things, of the character of the district, and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. Section 5. That this ordinance shall be cumulative of all other ordinances of the City of Grapevine, Texas, affecting zoning and shall not repeal any of the provisions of said ordinances except in those instances where provisions of those ordinances which are in direct conflict with the provisions of this ordinance. Section 6. That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of the tract or tracts of land described herein. ORD. NO. 3 Section 7. That any person violating any of the provisions of this ordinance shall be deemed guilty of a misdemeanor and upon conviction thereof shall be fined in a sum not to exceed Two Thousand Dollars ($2,000.00) and a separate offense shall be deemed committed upon each day during or on which a violation occurs or continues. Section 8. That the fact that the present ordinances and regulations of the City of Grapevine, Texas, are inadequate to properly safeguard the health, safety, morals, peace and general welfare of the inhabitants of the City of Grapevine, Texas, creates an emergency for the immediate preservation of the public business, property, health, safety and general welfare of the public which requires that this ordinance shall become effective from and after the date of its final passage, and it is accordingly so ordained. PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF GRAPEVINE, TEXAS on this the 19th day of January, 2016. ATTEST: ORD. NO. 4 ZONING RA — , — , — . — , — . _ _ _ _ _ .� - - - -- N89 59' ST'E 952.40' ZONING: R-7 .5 ^ i — — — — — — — — — — — — — — 10' REARYARD SETBACK —T- — — — — — — — — — -PROPOSED- -10' STREET PROPOSED 6' WOOD 3 �' "'�-1LwIGHTING TURNAROUND SCREENING FENCE _ 3p, / 30' HIGH N88-33'23' 83,161.I WICKET SIGHTING — FUTURE PARKING LIGHTING -0' HIGH FRONT YARD SETBACK ----- — —---------- 589° 29'58"W 265.11' NOl° 40' 18"W 30.01-' 6' WOOD SCREENING FENCE EX. FIRE HYC ZONING R-12.5 PROPOSED CRICKET FIELD (75 YD RAD) / LIGHTING 90' HIGH PROPOSED SIDEWALK FIRE HOSE LAY DISTANCE ALONG FIRE LANE = 420' +/- 90' HIGH PROPOSED--� RIGHT-OF-WAY DEDICATION (PER PLAT) PROPOSED CRIICKyET FIELD i EXISTING -1 GATE I 225' 735' b• 0' PROPERTY 1)B9. l PROPOSED 80' X 120' CANOPY STRUCTURE I — ,N cao' 02"vJ 170.42 . GRAPHIC SCALE PARKING SIGN so o z5 .w LEGEND t SAWCUT ( IN FEET ) PAVEMENT (CONCRETE) I inch = 50 It ✓. 7" 3500 P.S.I. ON 8" LIME STABILIZED SUBGRAOE F PAVEMENT (ASPHALT) 2" TYPE O ON 8" T%DOT TWE A OR D, GRADE 1 OR 2 GRANULAR BASE % T.SIDEWALK /FLATWORK j 4' 3500 P.S.I. THICK OTHERWISE NO PARKING SIGN NO PARKING SIGN d Ey/ PARKING r SIGN L NO PARKING / SIGN 0 N15° 01'2-"- FIELD 1'2P•cFIELD \NO LIGHTING90' HIGH PROPOSED PROPOSED / PARKING CRICKET FIELD IRRIGATION SIGN (75 YD RAD) POND 25• FRONT YARD ZONED: RA NO CURRENT USE: VACANT PARKING SIGN p' 735• 204.16' EX. 18" RCP El / / ( NO / PARKING SIGN FIELD PROP. N00° 30' 02"W 263.38' LIGHTING PROPERTY / 90' HIGH LINE EXIST. / PROPERTY / LINE — — — — — PROPOSED NO BACK _ _, RIGHT-OF-WAY PARKING — DEDICATION (PER PLAT) I SIGN N89° 29'58"E 676.39' NO PARKING SIGN I SI11, 18 c.m.luy EinU) fOxPftE VICINITY MAP NOT TO SCALE GRAPEVINE, TEXAS b11L UAIP, [T- --_ I I o I I I Z � I zI I W I ERMANENT UTILITY 6 SEATS (OUTDOOR COMMERCIAL EASEMENT K VOLUME 15499. PAGE 83 451, SPECTATORS /6=75 D. R. T. C.T. Q 3 I I 135'- � I 1 II I O II 1 I I OPEN SPACE REQUIRED II � I � (I I z II z No 0 II N II I (809. MAX) II I ;EUSE. IMPERVIOUS SURFACE PROVIDED 64,107 IF (1.47 AC) OiIDEYARD TACK II I —� a —IN EA SIGN ® a , ®I � II � � R1p II I i ® ORDINANCES. I Iry APPLICANT. DEVELOPER, -PROPOSE —SHOVE ?a DEPARTMENT OF DEVELOPMENT SERVICES �5' RE TR z TEXAS CRICKET ACADEMY CONTACT: KUMARAN (KENNY) THIRU -STRUOTUR II 4 Z z I I I +l, b W Ir MANSFIELD, TX 76063 COPPELL, TX 75019SEPARATE � I N I Il.m (@ least 48 hours prior to digging) DISCIPLINES. EACH SUBCONTRACTOR SHALL BE PROVIDED WITH AL SHEETS WITHIN THIS PLAN SET. o 3 � LI I e (I I II p5 I I I PERMANENT UTIUTY EASEMENT VOLUME 115603. 21 D.R.T.C.T. I FUTURE PARKING LIGHTING -0' HIGH FRONT YARD SETBACK ----- — —---------- 589° 29'58"W 265.11' NOl° 40' 18"W 30.01-' 6' WOOD SCREENING FENCE EX. FIRE HYC ZONING R-12.5 PROPOSED CRICKET FIELD (75 YD RAD) / LIGHTING 90' HIGH PROPOSED SIDEWALK FIRE HOSE LAY DISTANCE ALONG FIRE LANE = 420' +/- 90' HIGH PROPOSED--� RIGHT-OF-WAY DEDICATION (PER PLAT) PROPOSED CRIICKyET FIELD i EXISTING -1 GATE I 225' 735' b• 0' PROPERTY 1)B9. l PROPOSED 80' X 120' CANOPY STRUCTURE I — ,N cao' 02"vJ 170.42 . GRAPHIC SCALE PARKING SIGN so o z5 .w LEGEND t SAWCUT ( IN FEET ) PAVEMENT (CONCRETE) I inch = 50 It ✓. 7" 3500 P.S.I. ON 8" LIME STABILIZED SUBGRAOE F PAVEMENT (ASPHALT) 2" TYPE O ON 8" T%DOT TWE A OR D, GRADE 1 OR 2 GRANULAR BASE % T.SIDEWALK /FLATWORK j 4' 3500 P.S.I. THICK OTHERWISE NO PARKING SIGN NO PARKING SIGN d Ey/ PARKING r SIGN L NO PARKING / SIGN 0 N15° 01'2-"- FIELD 1'2P•cFIELD \NO LIGHTING90' HIGH PROPOSED PROPOSED / PARKING CRICKET FIELD IRRIGATION SIGN (75 YD RAD) POND 25• FRONT YARD ZONED: RA NO CURRENT USE: VACANT PARKING SIGN p' 735• 204.16' EX. 18" RCP El / / ( NO / PARKING SIGN FIELD PROP. N00° 30' 02"W 263.38' LIGHTING PROPERTY / 90' HIGH LINE EXIST. / PROPERTY / LINE — — — — — PROPOSED NO BACK _ _, RIGHT-OF-WAY PARKING — DEDICATION (PER PLAT) I SIGN N89° 29'58"E 676.39' NO PARKING SIGN I SI11, 18 c.m.luy EinU) fOxPftE VICINITY MAP NOT TO SCALE GRAPEVINE, TEXAS b11L UAIP, LAND USE: RECREATONAL/AMUSEMENT TOTAL LOT AREA: 20 ACRES (GROSS) 18.029 ACRES (NET) PARKING REQUIRED FOR USE: 20 SPACES PLUS 1 FOR EACH = 6 SEATS (OUTDOOR COMMERCIAL AMUSEMENTS REF ORD. 56.C.8) NO PARKING 451, SPECTATORS /6=75 51 720=95 REQUIRED TOTAL PARKING PROVIDED: 98 SPACES (4 REO'D HANDICAP) FUTURE PARKING PROVIDED: 114 SPACES (5 REO'D HANDICAP) RESTROOM/SHOWER FACILITY 1,600 S0, FT, OPEN SPACE REQUIRED 164,908 IF (3.79 AC) (20% SITE AREA) OPEN SPACE PROVIDED 258,561 IF (5.94 AC) BUILDING COVERAGE ALLOWED 494,728 IF (11.36 AC) (BOX MAX) No BUILDING COVERAGE PROVIDED 11,200 IF (0.26 AC) IMPERVIOUS SURFACE ALLOWED 659,638 IF (15.14 AC) (809. MAX) PARKING SIGN IMPERVIOUS SURFACE PROVIDED 64,107 IF (1.47 AC) 1, SITE PLAN HAS BEEN PREPARED AS E%HINT FOR PROPERTY ZONED RECREATIONAL/AMUSEMENT LOCATED LESS THAN 100' FROM RESIDENTIAL DISTRICT. 2. ALL PROPERTY LINES ABUTTING A RESIDENTIAL DISTRICT SHALL HAVE A 6' SCREEN FENCE PER SECTION 30 OF ZONING ORDINANCE. 3. NO NET FILL OF SOIL IS ALLOWED ON SITE PER U.S. ARMY CORPS OF ENGINEERS REQUIREMENTS. 4. YARD REQUIREMENTS: FRONT - 25 FEET, SIDE - 10 FEET, REAR - 10 FEET. 5. LANDSCAPING REQUIREMENTS ARE PROVIDED PER SECTION 53 OF ZONING ORDINANCE. 6. OFF-STREET PARKING HAS BEEN PROVIDED PER SECTION 56 OF THE ZONING ORDINANCE. 7. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERMISE NOTED. 8. ALL REQUIREMENTS OF THE GRAPEVNE SOIL EROSION CONTROL ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER:CU-15-47 LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION OXF E L Conditional Use Request CU15-47 is a ,NE A, = request to allow for the development of a ASPHALT NO CONNECTION PARKING NO PARKING �— NO PARKING cricket filed complex along with stadium lighting, a practice wicket area, and to CHAIRMAN SIGN SIGN SIGN exceed the maximum permitted height of a DATE: tent/canopy structure on 20 acres. No No No SHEET' 1 OF 9 PARKING SIGN ZONING RA PARKING SIGN PARKING SIGN ® APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR i ® ORDINANCES. APPLICANT. DEVELOPER, DEPARTMENT OF DEVELOPMENT SERVICES BANNISTER ENGINEERING, LLC CONTACT: BRANDON O'DONALD, P.E., CFM TEXAS CRICKET ACADEMY CONTACT: KUMARAN (KENNY) THIRU • 9, Know Wbat4S below. BRAN DONOBANNISTERENG.COM 240 N. MITCHELL ROAD KE NNYOTXCRICKET.COM 217 CREEKSIDE LANE Call before you dig. A INFORMATION ON THIS SHEET IS PERTINENT TO ALL OTHER DESIGI SHEETS IN THIS SET OF DRAWINGS. THE CONTRACTOR SHALL NOT MANSFIELD, TX 76063 COPPELL, TX 75019SEPARATE DRAWINGS FROM THE SET FOR DISTRIBUTION TO SP CH (817)842-2094 (512) 468-1711 (@ least 48 hours prior to digging) DISCIPLINES. EACH SUBCONTRACTOR SHALL BE PROVIDED WITH AL SHEETS WITHIN THIS PLAN SET. l $ V I—� z W WE z _ 2 ZE n Z u~i LU ry z ® W J LLJ H LL LU U.) iii V LU ~ � H — u (— z W 0 > LU 0 Z —I a. LA z WMA Ila. II -11 V) V z cW G F -i � 1a BWDON O'DO,YALOW saz»�� R 'YksyS/pkAL tMU.7° l•It- SHEET NO. C-2.1 i ...... _._._. ...... 566.5 7l 569.26 ME 569.2D I/ I m ON-SITE BENCHMARK BM#1 to FIELD FA I I 57.45 567.22567.00 566.00 ME ME ME ME 565.60 568 565.30 564.04 569.55 569 ZR } O .566 9. 5 � ebb �. / N _ I 566.40 DD EDEN 563.58 9.15 556 m 97 n V � 563.78 563.28 \� I 0 9.35 569.3 f 567.30) f 569.15 ��-56 ].30 / 569.25 3 64.0 566.46 ME: 569.15 / 566.6 569.35 569.35 �566.60i0 9.35 PROPOSED l h �O CRICKET �'� t FlELDr / 1 J 566.40 h �� I h 569.25I / ME4.34 565.40 567.5 569.35 569.35 O 566.40 567.30 \ ' "P 566.30 �_,.---567.30 se 6°j��56g rr l ® 66.71 566.47 Y•.®..1 E ME 566.36 YL�+ ME 1 `565.70 PROPOSED CRICKET FIELD / 1 _ I / 563. 563.5' 43 56 .4 O AU 1XI A, L II, S o FOXFIRE LANE -6- 18" RCP Q Know what's below. Call before you dig. (@ least 48 hours prior to digging) 0 W J LULL Z W (r, z V LU u Z e 1�1 H W V GRAPHIC SCALE 21 tLl W _P IN FEET) 1 i..h = 50 ft. LL GRADING LEGEND e Z ¢ f K EXISTING CONTOUR Z o U' -1.7- PROPOSED CONTOURS W ry DIRECTION OF FLOW 607.50 TOP OF PAVEMENT OR PROPOSED GRADE ME MATCH EXISTING 78 F ,_ ON-SITE BENCHMARK BM#1 to FIELD FA I I 57.45 567.22567.00 566.00 ME ME ME ME 565.60 568 565.30 564.04 569.55 569 ZR } O .566 9. 5 � ebb �. / N _ I 566.40 DD EDEN 563.58 9.15 556 m 97 n V � 563.78 563.28 \� I 0 9.35 569.3 f 567.30) f 569.15 ��-56 ].30 / 569.25 3 64.0 566.46 ME: 569.15 / 566.6 569.35 569.35 �566.60i0 9.35 PROPOSED l h �O CRICKET �'� t FlELDr / 1 J 566.40 h �� I h 569.25I / ME4.34 565.40 567.5 569.35 569.35 O 566.40 567.30 \ ' "P 566.30 �_,.---567.30 se 6°j��56g rr l ® 66.71 566.47 Y•.®..1 E ME 566.36 YL�+ ME 1 `565.70 PROPOSED CRICKET FIELD / 1 _ I / 563. 563.5' 43 56 .4 O AU 1XI A, L II, S o FOXFIRE LANE -6- 18" RCP Q Know what's below. Call before you dig. (@ least 48 hours prior to digging) 1. ALL SLOPES WITHIN ACCESSIBLE PARKING AREAS SHALL NOT EXCEED 2.0% IN ALL DIRECTIONS. ALL SLOPES At NO ACCESSIBLE ROUTES SHALL NOT EXCEED 5.0% LONGITUDINALLY AND 2.0% IN CROSS -SLOPE. 2, ALL SPOT ELEVATIONS ARE TO TOP OF PAVEMENT (GUTTER LINE) UNLESS OTHERWISE NOTED. ADD 0.5 FOR TOP OF CI1R8. 3. NO NET FILL OF SOIL IS ALLOWED ON SITE PER U.S. ARMY CORPS OF ENGINEERS REQUIREMENTS. CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER:CU-15-47 LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: st4EEr 2 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES U) 0 W J LULL Z W (r, z V LU u Z e 1�1 H W V GRAPHIC SCALE 21 tLl W _P IN FEET) 1 i..h = 50 ft. LL GRADING LEGEND e Z ¢ f K EXISTING CONTOUR Z o U' -1.7- PROPOSED CONTOURS W ry DIRECTION OF FLOW 607.50 TOP OF PAVEMENT OR PROPOSED GRADE ME MATCH EXISTING fl NOTES 1. ALL SLOPES WITHIN ACCESSIBLE PARKING AREAS SHALL NOT EXCEED 2.0% IN ALL DIRECTIONS. ALL SLOPES At NO ACCESSIBLE ROUTES SHALL NOT EXCEED 5.0% LONGITUDINALLY AND 2.0% IN CROSS -SLOPE. 2, ALL SPOT ELEVATIONS ARE TO TOP OF PAVEMENT (GUTTER LINE) UNLESS OTHERWISE NOTED. ADD 0.5 FOR TOP OF CI1R8. 3. NO NET FILL OF SOIL IS ALLOWED ON SITE PER U.S. ARMY CORPS OF ENGINEERS REQUIREMENTS. CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER:CU-15-47 LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: st4EEr 2 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES U) 0 J LULL Z W (r, z LU 1�1 H W V V Q LU LL Z UI a' Ln ®®/ M LLL> Wr� V bLINUHMAKKS BMRi: TOP OF EXISTING SANITARY SEWER MANHOLE RIM LOCATED NEAR THE SOUTHWEST PROPERTY CORNER. N: 7040527.68 E: 2390864.22 ELEV.=568.15 SOURCE BENCHMARK: GRAPEVINE MONUMENT NUMBER 1, ALUMINUM ROD WITH CAP FOUND 0.4 FEET BELOW ACCESS COVER, ACCESS COVER STAMPED 'CITY OF GRAPEVINE, MON. 1". MONUMENT IS LOCATED APPROXIMATELY 300 FEET SOUTH OF KIMBALL ROAD AND SILVERCREST LANE INTERSECTION IN THE CENTER OF A GRASS MEDIAN. ELEV. = 603.45' THIS SHEET IS PERTINENT TO ALL OTHER 1 SET OF DRAWINGS. THE CONTRACTOR SHALT NGS FROM THE SET FOR DISTRIBUTION TO H SUBCONTRACTOR SHALL BE PROVIDED WI S i p SHEET NO. C-3.1 PROPOSED 6' WOOD SCREENING FENCE 0 2 WOOD SCREENING FENCE GRAPHIC SCALE I IN FEET) 1 inch = 50 It. LEGEND: OEXISTING TREE TO REMAIN t n J EXISTING TREE TO BE REMOVED LANDSCAPE TABULATION: LOTAREA: __---_------—__ 824,538 sf (38,93 act OPEN SPACE REQUIRED: 20% SITE AREA OPEN SPACE PROVIDED: 164,908 d(3.79 a c) 258,561 d (5.94 ac) PARKING REQUIRED: PARKING PROVIDED: FUTURE PARKING PROVIDED: 95:PACES 98 SPACES 114 SPACES GROSS PARKING LOT AREA: PARKING LANDSCAPE AREA REQUIRED: 10% GROSS PARKING LANDSCAPE AREA PROVIDED: 52,907 sf 5,291sf 5,318 sf TREES REQUIRED: 1 TREE/2,500 SF OF REQ'D OPEN SPACE 1TREE/ 4005F OF REQ'D PARKING LOT LANDSCAPEAREA 66 TREES 13TREES TOTAL 79 TREES EXISTING TREES TO REMAIN: 9 TREES NEW TREES REQUIRED: 70TREES _ TREES PROVIDED: SHADETREES ORNAMENTAL TREES: 57 TREE: 21TREE: CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER: CU -15-47 LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET 3 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES i NOTE: Know what's below. Ad<as si dhWrb e tr con tr on zM1all b flM gntlM ane a dElknetl by we. Th < Hall be o-eyar<a ava mamrau,m vvm P<rmav<vc cava or yaa. is a<nl<v<a vdu, a Call before you dig. mp Imam o 7v my<rage. Thk k fl<wa<an ar as m m<ba<x a <oro arvuae m< (@ least 48 hours prior to digging) Prof m LU Ll— LU U, Z Q �gW Y w H W eV -I LL Q W LL LU �U/y V Z WCL M z V SHEET NO GENERAL NOTES: 1. Locate all utilities prior to digging. Contractor shall be responsible for all damage incurred by his/her work. 2. Contractor shall advise the Owner and Landscape Architect of any condition found on site which prohibits installation as shown on these plans. 3. If a discrepancy between drawings and plant schedule is found, the drawings shall take precedent over the plant schedule. 4. Plant material shall comply with all sizing and grading standards of the latest edition of'American Standard for Nursery Stock.' 5. Contractor shall stake out tree locations and bed configuration for approval by Owner prior to installation. 6. Substitutions shall not be made without prior written authorization from the Owner or Landscape Architect. 7. All disturbed areas not indicated as planting beds shall be sodded or seeded by Contractor to provide an established turf area. 8. Contractor shall remove reasonable amount of stones, dead roots, detritus and other undesirable material from existing soil. 9. If rocks are encountered, remove to a depth of 3" and add 3" of friable fertile topsoil to all sodded areas. Contractor to ensure that site is graded according to the Engineer's grading plan. 10. Lawn areas shall have 3" minimum friable topsoil and be treated with fertilizer applied at a rate of 20 pounds per 1,000 square feet. 11. Soil preparation for planting beds shall be as follows: 3" of organic compost 20 pounds of organic fertilizer/ 1,000 sf of bed area Till bed to a depth of 6" to 8" Check soil acidity. Soil acidity should range from 5.0 to 7.0 pH. Regulate if necessary. 12. Provide steel edge between all plant beds and lawn areas unless indicated differently on plans. 13. Tree planting pits shall be cleared of undesirable material and backfilled with prepared top soil. Place 1" of compost and 3" of shredded hardwood mulch on top of root ball. 14. The Contractor will be held liable for any damage caused to trees due to improper staking methods, including absence of staking throughout the warranty period. 15. Trees shall be planted at least 2.5 feet from any right-of-way line, curb, walk or fire hydrant, and outside all utility easements. 16. Trees shall be planted at least 8 feet from any public utility line where possible. In the event this is not possible, Contractor shall install a root barrier, per the detail(s) noted on this sheet. 17. Trees overhanging walks and parking areas shall have a clear trunk height of 7 feet from finish surface grade. 18. Contractor shall warranty plant material to remain alive and healthy for a period of one year after the final acceptance. All plant material shall be maintained in a healthy condition in accordance with the season. Dead, damaged or destroyed plant material shall be replaced in kind within thirty days. Warranty shall not include damage for loss of plant material due to natural causes, acts of vandalism or negligence on the part of the owner. 19. Landscape areas shall be kept free of trash, litter and weeds. 20. An automatic irrigation system shall be provided to maintain all landscape areas. Overspray on streets is prohibited. 22. Installing contractor to maintain landscaping for 30 days from owner occupancy to establish plants and grass, mowing and trimming to be included. 23. All areas disturbed by construction shall be fine graded and re-established by sod. These areas shall be irrigated and maintained until permanent stand of grass is achieved with a minimum of 70% coverage. This is to include all areas to the back of curb around the property. 24. All landscape areas,whether required or not must have an electronically controlled underground landscape irrigation system installed in compliance with current Texas Commission on Environmental Equality. NOTES: / d s / - 1. DO NOT HEAVILY PRUNE THE TREE METAL'T-POST'. THREE PER TREE, SPACED AT PLANTING. PRUNE ONLY �� ROOT BALL DOESN'T SHIFT. TREE. GUV WIRE SHALL CROSSOVER LIMBS. BRANCHES. INTERIOR TWIGS FLEXIBILITY ALLOW SOME FLEXIBILITY OF TRUNK. ALLOW SOME LEADERS, AND BROKEN EN OR DEAD DEAD OR TAMPED SOIL. NOT FIR REMOVE; HOWEVER, ETERMINAL BRANCH THE TERMINAL BUDS OF PROTECT TRUNK FROM GUY WIRE IO AND LATERAL BRANCHES MAY DE AND LATER SOME INTERIOR Y BE 05 EDGE OF THE CROWN. BDAMAGE WITH RUBBER COVER. (SEE NOTE BELOW) ELOW) PRUNED; HOWEVER, DO NOT 3" ca., 12' ht., Fuii, Mafchln SUCH THAT THE TRUNK FLARE IS SET TOP OF ROOT BALL 1' TO 2' REMOVE THE TERMINAL DUDS OF saidCypress BALL. TREES WHERE THE TRUNK ABOVE FINISHED GRADE. BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. Plstaohla chic -Is L.U-troema indica REJECTED. DONOTCOVERTHE (2') MULCH LAVER ABOVE PREPARED SOIL. TOP OF THE ROOT BALL WITH SOIL. 9 3. REMOVE ALL TWINE, ROPE, WIRE MAINTAIN THE MULCH WEED -FREE FOR 2. EACH TREE MUST SE PLANTED ROOT BALL. A MIN. OF THREE YEARS AFTER SUCH THAT THE TRUNK FLARE IS I� SH BA KE AROUND BASKET E BASKET IN FOU L. PLACE FOUR PLACES THE WIRE DOWN PLANTING. VISIBLE AT THE TOP OF THE ROOT DATE: o W HIGH EARTH SAUCER IN 5' BALL. TREES WHERE THE TRUNK Raphidepis indica Indian HaWlhom Clara' DIA. RING AROUND ROOT BALL, FLARE IS NOT VISIBLE SHALL BE 18 Leuco h lum 5utecens Texas Sae REJECTED. DONOTCOVERTHE C 23 TOP OF THE ROOT S&L WITH SOIL. Dwarf Burord Holly 5 gal., 24" ht, 30" O.C., triangular spacing 3, REMOVE ALL TWINE, ROPE, WIRE 4 Naldina domesbca Fire Wer AND BURLAP FROM TOP HALF OF 5 gal., 24" ht, 30" O.C., than ulara acin TAMP SOIL AROUND ROOT BALL BASE ROOT BALL. I FIRMLY WITH FOOT PRESSURE SO THAT Hameln Gass Salvia Red' ROOT BALL DOESN'T SHIFT. 4. IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND ROOT BALL. CUT PLACE ROOT BALLON UNEXCAVATED THE WIRE BASKET I�N� OR TAMPED SOIL. 8 NFTOOUPR��PALNAiC�NEGS ANp F002WAL'IREES WITHIN OU FEET OF A PLAYGROUND OR HOLE. PLAYFIELD ,UNLESS SEPARATED BY VEHICULAR PAVING, SHALL BE REINFORCED WITH WOOD STAKES (SEE DET. B, THIS SHEET) IN LIEU OF METAL-T�POSTS'. %qI TREE PLANTING DETAIL NGTTa.�A1E !'1 Q 3" HIGH EARTH SAUCER 1"COMPOST AND 2" MULCH.BEYOND EDGE OF ROOT BALL.BACKFILL PIT WITH PREEXCAVATE PIT TO A WIDTH EQUAL TO 2.5 TIMES SOIL PER GENERAL NOTTHE ROOT BALL WIDTH. PLACE ROOT BALL ON UNEXCAVATED OR TAMPED SOIL. SCARIFY SIDES OF PIT. CONTRACTOR MAY EXCAVATE LARGER PIT FOR MULTIPLE PLANTINGS. REMOVE ROOT BALL FROM CONTAINER AND SCARIFY. e L� 0 B SHRUB PLANTING DETAIL NOT TO SCALE a,e ru�c Hrc v nx¢ .a e< IBnU �,au�"iuis r'°oais s�°0S s, "m veno. � (a>.4rnwaour� awm �.� sae urr�vn oanasx J=' rore,",ra =at D- rwrew IM EY sno roams 'z KAawA.s To a Har Drum oALv. artlrr£ anal 7D.n ria ~ Alm --d miwlo . Acea Aic - wro o s s Au FIaAE PAraL. TO ea stt Lsw, m/ slseew xor m oaAm e• ro ARWIWDAie CRA.E - A.AISi POST Aala As NFmm. aAenNx caxrauous PAx¢ aaAsua¢ of 1r eft Nft&%,"I6wt' FSHrE eaums eseLE mm sllaxr os Ao.nlrro I'Raltptt. SCREENING FENCEFENCE NOTTO SCALE PLANT LIST AND SPECIFICATIONS: NOTES: d s / - 1. DO NOT HEAVILY PRUNE THE TREE COMMON NAME AT PLANTING. ONLY CROSSOVER LIMBS,BS, C CODOMINANT �� ROOT BALL DOESN'T SHIFT. LEADERS, AND BROKEN DEAD BRANCHES. INTERIOR TWIGS cMULTI V AND LATERAL BRANCHES MAYBE OR TAMPED SOIL. NOT FIR REMOVE; HOWEVER, ETERMINAL BRANCH THE TERMINAL BUDS OF Nn,Tn- BRANCHES THAT EXTEND TO THE 05 EDGE OF THE CROWN. Quercus ahurnardil 2 EACH TREE MUST BE PLANTED 3" ca., 12' ht., Fuii, Mafchln SUCH THAT THE TRUNK FLARE IS 18 VISIBLE AT THE TOP OF THE ROOT saidCypress BALL. TREES WHERE THE TRUNK PC LI FLARE IS NOT VISIBLE SHALL BE Plstaohla chic -Is L.U-troema indica REJECTED. DONOTCOVERTHE 3" cm, i2' ht., Full. Matching 3" cal., 8'-8' ht.. 35 canes min., Full, Matched TOP OF THE ROOT BALL WITH SOIL. 9 3. REMOVE ALL TWINE, ROPE, WIRE Vilex AND BURLAP FROM TOP HALF OF ROOT BALL. d. IF TIS HIPPED WIRE I� SH BA KE AROUND BASKET E BASKET IN FOU L. PLACE FOUR PLACES THE WIRE DOWN C I I AND FOLD DOWN a' INTO PLANTING HOLE. DATE: SET TOP OF ROOT BAU-1- TO T ABOVE FINISHED GRADE. (2•) MULCH LAVER ABOVE PREPARED SOIL. MAINTAIN THE MULCH WEED -FREE FOR A MIN. OF THREE YEARS AFTER PLANTING. 3' HIGH EARTH SAUCER IN 5' DIA. RING AROUND ROOT BALL. WOOD STAKE, THREE PER TREE, SPACED EQUALLY AROUND TREE. GUY WIRE SHALL ALLOW SOME FLEXIBILITY OF TRUNK. PROTECT TRUNK FROM GUY WIRE DAMAGE WITH RUBBER COVER. CRITICAL ROOT ZONE AREA Tn1 TREE PROTECTION DETAIL u O EXISTING TREES) TO REMAIN. O DRIPLINE OF EXISTING TREE (TYP) O CONTINUOUS NYLON TIE STRING TIED TO STAKE TOPS W12'TUNDRA WEIGHT ORANGE STREAMERS @ 3' O.G. O4 8METAL TSTAKES: Y O.C. MIN., DRIVEN 2' INTO GROUND AT (OR OUTSIDE) TREE DRIPLINE (D -IN. MIN. HEIGHT ORANGE PLASTIC FENCING INSTALLED PER MANF. RECOMMENDATIONS(TYPL SUPPLEMENT WI SILT FENCE FABRIC @ PRUNING TRENCH AS REQ'D. O EXISTING GRADE TO BE DISTURBED. OT SCOT PRUNING TRENCH - OUTSIDE FENCE SEE NOTES, O EXISTINGGRADE TO REMAIN. SYMBOL d s / - �-TAMPS 11- WITH OOT ROOTBALLRASE FIRMLY WITH FOOT PRESSURE SO THAT COMMON NAME - �� ROOT BALL DOESN'T SHIFT. PLACE ROOT BALL ON UNEXCAVATED cMULTI V -TRUNK TREE PLANTING DETAIL OR TAMPED SOIL. Quercus N IBlana Nn,Tn- CRITICAL ROOT ZONE AREA Tn1 TREE PROTECTION DETAIL u O EXISTING TREES) TO REMAIN. O DRIPLINE OF EXISTING TREE (TYP) O CONTINUOUS NYLON TIE STRING TIED TO STAKE TOPS W12'TUNDRA WEIGHT ORANGE STREAMERS @ 3' O.G. O4 8METAL TSTAKES: Y O.C. MIN., DRIVEN 2' INTO GROUND AT (OR OUTSIDE) TREE DRIPLINE (D -IN. MIN. HEIGHT ORANGE PLASTIC FENCING INSTALLED PER MANF. RECOMMENDATIONS(TYPL SUPPLEMENT WI SILT FENCE FABRIC @ PRUNING TRENCH AS REQ'D. O EXISTING GRADE TO BE DISTURBED. OT SCOT PRUNING TRENCH - OUTSIDE FENCE SEE NOTES, O EXISTINGGRADE TO REMAIN. SYMBOL QUANTITY BOTANICAL NAME COMMON NAME SPECIFICATION TREES LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 QV 18 Quercus N IBlana Lica Oak 3" cal., 12' ht Full, Matchln 05 13 Quercus ahurnardil Taxa. Red Oak 3" ca., 12' ht., Fuii, Mafchln TO 18 Taxodium Ssdchum saidCypress 3" cd., 12' ht., Fuli, Matching PC LI 10 12 Plstaohla chic -Is L.U-troema indica Chinese Plstsche Cape MyNa Natchez' 3" cm, i2' ht., Full. Matching 3" cal., 8'-8' ht.. 35 canes min., Full, Matched 21 9 Vitex agnus vastus Vilex 13'.d., "'ht, 35 canes min., Full, Matched CHAIRMAN SHRUBS O DATE: o RI 32 Raphidepis indica Indian HaWlhom Clara' 5 gal- 24" ht, 30" O.C., tdangularspacing LF 18 Leuco h lum 5utecens Texas Sae 5 gal.. 24" ht., 30" O.C., titan ulas .cin C 23 lex comute burbldii nano Dwarf Burord Holly 5 gal., 24" ht, 30" O.C., triangular spacing ND 4 Naldina domesbca Fire Wer Fire wer Nandnna 5 gal., 24" ht, 30" O.C., than ulara acin PA SG 5 3 Pennistetum alopecurddes'Hameln' Salla greggii Hameln Gass Salvia Red' 1 gal. 17 min. ht 18" CLC, triangular spacing 1 gal 12" min, ht 24" O.C. Mangularspming RR 13 Rosa'Rad-. Knockoul Rose Red` 5 gat., 24" hL, 30" O.C., tnangularep-ing GROUNDCOVER TA 125 Tnchelospemlum asiaUcum I Asian Jasmine 1 gal.. 24" O.C., loan lar spacing LM 13 Lidope muscad'Vangated' Vangated Linope 1 gal.. 18" O.C., indngUlar spacing LAWN Per Plan Cynodon dactykm Common Bennud. Sod STEEL EDGr'1G Per Plan 4" steei edge to be bused 3" deep. Contractor to intall steel stakes at end of each section ofedgaing. DECOMPOSED GRANfiE Per Plan 3 natural color decomposed granite compacted With permease vreedmat. S WLDER Per Plan 3-0' 11, Mass Rock, bottom to be bused 3" below giade for stability NOTES: 1. PERFORM ROOT PRUNING ON ALL EXISTING TREES TO REMAIN WHERE CONSTRUCTION ACTIVITY FALLS WITHIN DRIP LINE OF EXISTING TREES. ZR OT PRUNING METHOD: 2 MONTHS MIN. PRIOR TO EXCAVATION 8 CONSTRUCTION ACTIVITIES, HAND CUT ROOTS BY DIGGING A 18'-24' DEEP a WWI ETRENCH ALONG THE OUTSIDE PERIMETER OF EXISTING TREE(S) ADJACENTTOCONSTRUCTIONAREAS. MAXIMIZE PRUNING TRENCH DISTANCE FROM TRUNK TO THE FULLEST EXTENT POSSIBLE. WI THE ROOT PRUNING LINE PLACED Q THE EDGE OF CONSTRUCTION LIMITS. • ® e Know what's below. Call before you dig. (@ least 48 hours prior to digging) 0 J W W_ ILL. ISJ (, TJ Z Uj W 1-- Cy-1LLZ_ 0- W �1-I U a Z Ln W M (D r1. Y� CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER: CU -15-47 LOCATION:3451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION 8 S CHAIRMAN O DATE: o w SHEE'6. 4 OF 915 - z ¢ a APPROVAL DOESNOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES, DEPARTMENT OF DEVELOPMENT SERVICES K 1`T !q Jj 2433 h q>F � �P oi- 11-`Z�1Ga SHEET NO. NOTE: Al ar< dhturbed by "'w'cnon shall ce fine gad. and 11-bhhed by sod. These 1 1 �_ I I areas shag. Irrlgakd and mai__ until permanent stand d gals Is achieved vMh a mNhnum d 7WE coverage. Thus Is to IndNd an arena m cite uaa of euro done property. a CONTINUOUS LIGHT LEVEL Spill @ Property Line 126 points ALL FIXTURES TURNED ON HORIZONTAL FOOTCANDLES N SPILL READINGS @ SOUTH REFLECT A SIGHTSCREEN Average 0.8 Maximum 3.0 Minimum 0.0 Pole x-loc y -IOC height NARROW MEDIUM MEDIUMONARROWC Total[20558 P10 -159 -166 901t 6 23 29 P11 159 166 90ft 6 23 29 P12 159 -166 90ft 6 23 29 PS -320 -234 30ft 1 1 2 P6 -357 116.3 30ft 159 -166 90ft 6 23 -159 166 :Oft 6 23 24 92 2 2 P7 -54 571 30ft 46 46 44 3 3 6 P8 54 571 30ft 3 3 6 P9 -159 166 9011 6 23 29 Total 44 P9I 59 58 54 24 92 9 7 132 @tai- 0.1- e-Ne.t- 9.t r e.r eS-e.r 6.t--e:i- 9.i- a:r-0.� -0.+--Pr -0.a -0:i--0.+ -0+-&4 -0i di --or -0-1-ei -0-1-6.e--ofl-OO�I0 I P7 P8 b' at b �aro-1-41 1 f at .i. ' � ' • / •I � Iall tl I it I DO a 1 at I I at 1 El, / coil/ t at I �1 0,2 12 Ell _ _. ---------------- _ I 6 f 'ill \,\\��\\�\;\ �•i� :1i'i 14\ / w\\..`� �i/!i/J li I\t \° \ oa3 l , I \\\ \ /j /// \ \ \ 0/5 012A�''V �/•I 1vA - is ii A. O12 �\• i 'v:glii;�U'�:-�i=\-�Q\�\iii,/ 0,4 �1 Pi - 12 qI OI3 4 P5 ( uture) 1.R 2-0-2-2-45-2830-30-3.6-30-?�2-�r qt I GOARANTITO POR THR RAT® llFE OF TI1R Id.4 -0i 6x0.4 -0:2-&P -03 tea.^ -a? 2 ,,,\I ,m[{yN +/-IOT. of GGR'[ aK OF �>VEl POQi19 MAY VARY FROM THIS INFORMATION IS CONFIDENTIAL AND P PIES IR Do. -D. HASID ON PROPER PREDICTIONS. UNIFOR1lITIES TO QUALITE SPORTS LIGHTING, LLC AND IS NOT T DIS-UTION• VOLTAGE/ -3%. Pam GUARANTEED TO MEET THE IESNAS EE REVEALED OR DISTRIBUTED TO OTHERS WITH0 T PLACEMENT AND IIOIRTFNG HEGHT WITHIN 3 RECOMMENDATIONS (UNIFSS SHOWN FEET aP SPH'� ECD IIICATION AND HEGHT. I PERMISSION OF QUALITE SPORTS LIGHTING, LLC 0 HIGHER DUE TO DESIGN CRITERIA). USED IN ANV MANNER DETRIMENTAL TO THE INTE EST SEAND TANDARDB fU COMPLY WITH CURRENT AA9HT0 OF QUALITE SPORTS LIGHTING, LLC CONTINUOUS LIGHT LEVEL P7� ,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI F mYfa ,m 1U0111p0 ®IAT aYY,R® A iHi Iv�eq.5* QWIOm®Al1d NARROWO -- MEDIUM - UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW MEDIUMO NARROW UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW NARROW UNIVERSAL SERIES V 1000W MEDIUM UNIVERSAL SERIES V 1000W Pitching / Batting Area 24 points at z=3, sp 20ft by 20ft HORIZONTAL FOOTCANDLES Average 50 Maximum 67 Minimum 38 Avg: Min 1.32 Max: Min 1.76 Coef Var 0.18 UnifGrad 1.56 N DR VIEW FRONT VIEW BACK CRICKET GROUND LIGRT/NC TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX POELS P91 PIU, PN s FIX : nBBwrTriru. ,I ra SAT ASSXYBLLT.��M��Y�° TDP VIEW 10 r PI-H-A'A" /`r � ennrs 43 SIDE VIEW nxu m T" v sua<am wu mis Li FAVML FRONT VIEW BACK VIEW CRICKET GROUND MORI G TEXAS CNO)STF ACADE".. SOUTHLAEB. TX ItlELS PT ! P6 HARDWARE LIST 2 5 5 67 8 THREADED ROD I 2 B 51 6' THREADED ROD 2 2 4�aTmeP�'e I" BRACKET I 2 B ,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI F mYfa ,m 1U0111p0 ®IAT aYY,R® A iHi Iv�eq.5* QWIOm®Al1d NARROWO -- MEDIUM - UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW MEDIUMO NARROW UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW NARROW UNIVERSAL SERIES V 1000W MEDIUM UNIVERSAL SERIES V 1000W Pitching / Batting Area 24 points at z=3, sp 20ft by 20ft HORIZONTAL FOOTCANDLES Average 50 Maximum 67 Minimum 38 Avg: Min 1.32 Max: Min 1.76 Coef Var 0.18 UnifGrad 1.56 N DR VIEW FRONT VIEW BACK CRICKET GROUND LIGRT/NC TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX POELS P91 PIU, PN s FIX : nBBwrTriru. ,I ra SAT ASSXYBLLT.��M��Y�° TDP VIEW 10 r PI-H-A'A" /`r � ennrs 43 SIDE VIEW nxu m T" v sua<am wu mis Li FAVML FRONT VIEW BACK VIEW CRICKET GROUND MORI G TEXAS CNO)STF ACADE".. SOUTHLAEB. TX ItlELS PT ! P6 HARDWARE LIST 9 42- 51 67 8 THREADED ROD I 2 B 5 J 6' THREADED ROD 2 2 4�aTmeP�'e I" BRACKET I 2 B ,y,f�pNlp4lm,��pl���M�i �~� BaH101ULL FaEI F mYfa ,m 1U0111p0 ®IAT aYY,R® A iHi Iv�eq.5* QWIOm®Al1d NARROWO -- MEDIUM - UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW MEDIUMO NARROW UNIVERSAL SERIES V 1000W UNIVERSAL SERIES V 150OW NARROW UNIVERSAL SERIES V 1000W MEDIUM UNIVERSAL SERIES V 1000W Pitching / Batting Area 24 points at z=3, sp 20ft by 20ft HORIZONTAL FOOTCANDLES Average 50 Maximum 67 Minimum 38 Avg: Min 1.32 Max: Min 1.76 Coef Var 0.18 UnifGrad 1.56 N DR VIEW FRONT VIEW BACK CRICKET GROUND LIGRT/NC TEXAS CRICKET ACADEMY. SOUTHL.IXE. TX POELS P91 PIU, PN s FIX : nBBwrTriru. ,I ra SAT ASSXYBLLT.��M��Y�° TDP VIEW 10 r PI-H-A'A" /`r � ennrs QUALITE 215 W. MECHANIC ST. HILLSDALE, MI 49242 CASE NUMBER:CU-15-47 LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION. MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET: 5 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES SPORTS LIGHTING, LL( PHONE:517/439-1581 FAX:517/439-1194 800/933-9741 12/7/2015 1 QL-17049D22=.IG CRICKET GROUND LIGHTING TEXAS CRICKET ACADEMY, GRAPEVINE, TX TWS I SCALE=1 1 II -17-15 SIDE VIEW nxu m T" v sua<am wu mis Li FAVML FRONT VIEW BACK VIEW CRICKET GROUND MORI G TEXAS CNO)STF ACADE".. SOUTHLAEB. TX ItlELS PT ! P6 HARDWARE LIST �nBwN.T ,>B rxar CVNACOwrfaxs TOAb'SEYBOJtS. rmnore mB TOP "I, f1ue,BeB eon -� HARDWARE ID. L DESCRIPTIONTY.TY. TAL 8 THREADED ROD I 2 B 6' THREADED ROD 2 2 4�aTmeP�'e I" BRACKET I 2 B 618' CALV. NUT 12 2 24 Pde 6 B' GAL L ASNER 12 E 2I Total kN 314 4, S.S. TH. ROD 2 2 4 CONTINUOUS 0* LOCK-►ASHEF 2 2 4 LIGHT LEVEL 314- FLAT-IASHER 4 2 B -159 -168 90ft 6 23 159 166 Sort 6 23 29 29 S 4: S.S. NUT 4 Y B ' M!( BBLT B IB OWNIA N B 2 IB B" S.S. LOGE IASHER B 2 TB Li 2- NIPPLE PKC Y1 2 1 f QUALITE 215 W. MECHANIC ST. HILLSDALE, MI 49242 CASE NUMBER:CU-15-47 LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION. MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET: 5 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES SPORTS LIGHTING, LL( PHONE:517/439-1581 FAX:517/439-1194 800/933-9741 12/7/2015 1 QL-17049D22=.IG CRICKET GROUND LIGHTING TEXAS CRICKET ACADEMY, GRAPEVINE, TX TWS I SCALE=1 1 II -17-15 Pde a -lac NARROW MEDIUM Total kN CONTINUOUS LIGHT LEVEL 'to Pit -159 -168 90ft 6 23 159 166 Sort 6 23 29 29 47.1 47.1 P12 P9 Total 159 -166 90ft 6 23 -159 166 :Oft 6 23 24 92 29 29 116 47.1 47.1 188.5 44 46 46 46 44 MEDIUM UNIVERSAL SERIES V 150OW 44 P9I 59 58 54 53 54 58 59 44 I'll NARROW 53 54 55 53 54 54 54 53 55 54 53 UNIVERSAL SERIES V 150OW 47 56 56 55 52 53 3 52 55 56 56 47 47 57 54 50 0 53 55 53 50 54 57 47 54 56 52 5 54 53 54 53 54 0 52 56 54 5 51 57 52 52 1 55 5RIEUEM 55 1 52 52 57 51 46 53 52 53 53 53 53 52 53 46 CRICKET FIELD 51 57 52 52 1 55 55 1 52 62 57 s1 177 points at z=3, sp 30ft HORIZONTAL FOOTCANDLES by 30ft Average 53 3 54 56 52 5 54 53 54 53 54 52 56 54 Maximum 59 Minimum 44 47 57 54 50 0 53 55 53 50 54 57 47 Avg: Min 1.20 Max: Min 1.34 Var 0.06 47 56 56 55 52 53COef 53 52 55 56 58 47 UnifGrad 1.34 53 54 55 53 54 54 54 53 55 54 53 Pilo 44 59 58 54 53 54 58 59 44 P12 44 46 46 46 44 avtWriA _ � 90111WLL Fa91>s YAT 9ANY TROY T� �� m n a01YN®A I�mt �Ab 1.a m7Eats1 ai�� n� o OCtlamIWIDA 1aNMa BBaTII BO®1 DNR A �R 4LI®Al. QUALITE 215 W. MECHANIC ST. HILLSDALE, MI 49242 CASE NUMBER:CU-15-47 LOCATIONZ451 FOXFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION. MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET: 5 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES SPORTS LIGHTING, LL( PHONE:517/439-1581 FAX:517/439-1194 800/933-9741 12/7/2015 1 QL-17049D22=.IG CRICKET GROUND LIGHTING TEXAS CRICKET ACADEMY, GRAPEVINE, TX TWS I SCALE=1 1 II -17-15 - Ll.i H, I'I_ AN TL�.�..,� � 4 1 - Br 1— 1V FUUI Br are. Btl b F. -Callon i Foundation Slab Texas Cricket Academy 1 I j I T.--1. A°aoBmy rr�B21M �/ FOUNDATION PLAN L B B' 1 EEtltESESII °X-�X.i W C£fER.SEREEtl DUNPBTEB B. _._- ............._.-._._. la Daa�Bam, s«.a� E Gates F_EN6E SEE- TI°N IRI YBD1.E W B WIDE { i I z xo..EB EaBTku.x rExcE>I«B,s 9 EE�cB.xxEi To ^4O2-Dx e6 —EL EUBT FENCE DETAIL CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER:CU-15-47 LOCATION:3451 FOxFIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET. 6 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES LLJ U) D 0 LLJ 0 U LLJ \�� z � � z W W � �Q Q Q UU Q < \/ O LL LL X z 00~ Q L z o o LLQ LLJ /W LJ� y y a- J UUQ -Wi CL� CL� K U U = \J a rn REVISIONS REV. DATE: BY SHEET NO. XX 7 26 gouge Standing Ridge b colored Metal Roofing James Hardie Fiber Cement Jamea Hartlle / Sl Eing Fiber Camenl Garage Door siarn M^\ Door _ a x 14 xac o'. 3 0x6-6 stone Veneer / Rear Eleval'Dn Texas Cricket Academy la a'r }=•'r �, r3at Iia \ LED Llghta LED Lightd a -,Ips:. to I 1 a a •s ° a Metal Enteranca stone Venae F -_ Door-St—V.—, Front Elevation Texas Cricket Academy 26 gauge Standing "dge colored Metal Roofing Jamea Hardie Fiber Cement JemesH Fiber Com a, and / /Siding siding 7 LED Li /'-ght.� v b LED Lights 1'i I/tlll�`JJ Garage Door st a Veneer M^\ Door _ a x 14 xac o'. 3 0x6-6 stone Veneer J Rear Eleval'Dn Texas Cricket Academy Texas Cricket Academy a -,Ips:. to j 26 Hauge Standing Ridge oolbred MCI Roorinq Jamea Hardie Fiber came samgm Jem ea Herdie Fiber Cement 26 9aa90 Stantling Ridge Sltll q colored —.1 Awning 10'x10' LED Ligbta/ . I •a. •xa x I — .. -,� LED Llghta— I' stone veneer Stone Veneer ' South Side Elevation Texas Cricket Academy ••slam91. Jam a. Haraie Finer camera abam ane s )5X or eell0ing. James Hartlie 26 yaoSt—mg Ruga Fiber Cement wl9r9d Metal avandv -i- 29 gauge —d- Ling RidgeNorth Cide Flevati on colored Metal Awning Texas Cricks t Academy t9•xta• -Ti ae Cdekef Academy Rad Mlau LK 9)a-a:l ))ml CASE NAME: GRAPEVINE CRICKET FIELDS CASE NUMBER: CU -15-47 LOCATION:3451 FOXFIRE LANE; LOT i BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET 7 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES W U) 7) 0 w 0 rI V I L�yL WW Q� U U Q Q cn X 00 ~ O 0- El- Q z > j � wwW w y Y- n w UUQ CL� c w K U U _ 6. N REVISIONS REV. DATE: ey SHEET NO. X X/ f ==Al- INFO�=/M N onu __ wEPLn�ml� --_.— PND srFiL z,acn _. NMECTpNPIATE9 TE, 6Y'ixlcx aussEr _.._-__. TE. irrrx�cx ___ IxATEl DRDL L c wL_V. PND. sr RcxaP eacl L oP o � --- Pcnai 1 ean1. Du PxD s EiL TEE m: a ,a A1,1 e. D E __. vEArcu iaoulyoEDl _ —CK DEDsrw PEaDE rr,s., F - NCE eoL I ) _..SUONr -_--. TRIP- _-. C,BIE COIM.EC1ron RATe TE vte IwCJtLE... KLE - -_ N m,ENDUE -IIT -..-TRPEnoEn s.TUOS '.STEEL vurE,,rz' DETAIL LOCATION CALLOUTS T080HKMF001120 80x120 HKM TRUSS FRAME IN (Ail ...... _............ -.-COVER SHEET IB11 ......._.... _-...GENERALNOTES IC11 ..............BUILDING PIAN VIEW ID11 ...... MATERIALSPECIFICATIONS IE1I .. .. RAFTER PROFILES IF17 SIDE PROFESS [G11 .. .DETAIL LOCATIONS 8 BASE DETAILS IG21 .. ._SPLICE CONNECTION DETAILS IG31 ..... ...BRACE CONNECTION—MLS MAI .. .. C LE LAYOUT S DETAILS Mi] .._...... ...SASE PUTS UVOUTBS IHTI ............. ... ...FWNDATON DETAILS (ANCHORAGE) NAI .... ...BUILDING REACTION DATA IN ......OMITTED Ti� IL1 L])... ...FRONTENDWALL—HKF.110 IM 1- M21 .......... AMI � TTED. BACK ENDWALL OPEN lail v�x�i-AxrnEDePxCEcanEcxox � a.*`'� ��ox�v'rtew, snlcE sibinEaxai i°sE F,EPaxo E �E� „ rcsB..�F..BmR DwEsacElsEaNExrrosESNExn /� I�NVE�wsEu R.,ND,�Ecax,�DroxP.Dl� . Ia1vlrE�wB Bu,EPnt BPacEcaxxEc,gx B.ql ' / , I�Pw�H�rEBIBaPPaPre.BEraBEaI,ExP� � 9 «,a Icnvre""wd°'BensE rD wPPOPTBnsEmxxecTwx� �`% IG,1�3 wiucx mnrEwxuecrax,swoeuvsLEl ' [Gil VIEW 1 -NOT USED OR 920.14— aN BED'a W±RX s)2 �i" S !y<xexN:i IWME I. HDB,B PLS _ \\ [Gil VIEW 2- BASE pTO SUPPORT BASE CONNECTION (uli2xui _ � wNOI [G71 VIEW 3 - WINCH PLATE CONNECTION (IF APPLICABLE) . =M7, E,FA/M.irRCxlLpe.VgNles/ nw3 .t e v mncca+¢41cEN,ix,xEurFsieDRlw1 C£ w�fnfzarED B'EBwvemucvnE �, Tai �..ivnx®siEEL. BPacsssEsaWFmgcncEs 9LBLSELDEDJ: ,us PePEaWEn ev cTPnFlEn wEimis IDI 7 NI E 111D =MM IM FRneNC Gaal aN .wFAs w,mwvnPEHwsl. suPFncUTAsr BEaEaxaxsaL FPEE CTaFu �DrmuxD uPEiavl•ox'siFivanaxawnrEPws. c°naixlxsum FanNcnrxw.wD ."fwEhnsvmvlmLer wvnuHw�o roxurowiD wn�.w°wunP[o gxBa.s P N . roBxa N�raPE D iP p PN WHINrNE s,xVciVPE EPECTxM. '_S_iaolxwxw ^PDPCE'P[55,—acaa4UaBAI,YFro src°PP e. m ss. ane,N!cn DPnDEw DP EWUFDP c=_rxav she N,nE war(�'siPunaP4 no El.1.112 o(.muAeDl WxxEc° ilaxv:T ixEvmetEvusPwua, j�l. fN°F H. °6P BN�wPE a. TMF �•BP Df,w x W xaro P. a awP xDPeEP Grp=. P ExaDl ,,BP E,E<naP M H,BEEL MUII°m61 Nmsa'o`i'.-:ixg puxc-oP-,.e I:auLRG� enwe®Feec a` : —MI—d d sko- D w1 rxw. ,xwi�s"�N0 wEwEorPw sPm s/A«oP lnm:i."•n�celr.o.w,coro.,.Dx InB�,PnAwx,.xD eem.. rlaln=xEnuNEBulmxL,.•-..BnaBEVErncr<au,Nx. Bx¢:T cZw FrernE BNpxc z. arenros rEBPRI EDPaxcxaxceslw L. --T B - LATERAL BRACE (SKU: LB3%NSTLIN) AB ANGlEO BRACE (SKU: ASa'A1MNLIN) TAB ANGLED BRACE ISKU: AB]SGIMNLIN) SPLICE: SEE DETAIL SHEET IG31 j .PINE O `–o<.mP661,EE. P1BNxx.N»EB ` j / ,� `i L7 ePab [EI] VIEW 1 - FRONT PROFILE (END RAFTER) e IETI VIEW 2 - FRONT PROFILE (MID RAFTER) LB -LATERAL BRACE BAY (SKU: LB35GUSTL1N) SPLICE: SEE DETAIL SHEET 1.31 - Ifi%IBNx1'lEl: enc°PurER t �PFDcI � °EPI^h PH,Bx�xaPeafl . R4 IW M1%PiEx BOev, BEoxErO Rro \ xx[ '), � Fjt�'�i �� RNmMc4BCf\ n„ x . >: of w m .,,• xPw� 'F aala malA�;a _ _. `.� `�N,ncEPv,TEln,oaatcPBDFI ro,E.ea.s,Ps,awwx '� [GRI VIEW 1 F BRACE PLATES jjG2 VIEW 2' BRACE PLATES [4321 WEW 3 -MIDDLE SPLICE (SSEGMENT 70 SEGMENT) (SU�PORT BASE TO SEGMENT) (SSEGMENT TO SEGMENT) �,ax xaT +tr .a'-. �_Wlvrx�nExaa.vlc Dl%E tB�`lt ..w reau ew,a xa,El„eNT Y$ Pu,EDtmS gri-w}I Pnn:Pa�xn_o.E� eNEx lErol r� I aN °„w3; aE a ro K �DEj'a""P,xP B Aea --- x�P�,ExaxaPD TRNN.I I 54321 VIEW 4- END SPLICE [G2] VIEW 5- LATERAL BRACE S GYENT TO SEGMENT) CONNECTION (END) IG2I VIEW 6 -LATERAL BRACE PurEP CONNECTION (MID) Ixlva+*InEN,�/.. ISD Beate a*EPSEaNEBw.rSMce wrry P /� ,Ero PN,EPc„aPe '" pm Pa.hP�xax - PxaPaH�®wx�r N,, _ NEx.lwDl � oes,Iarx xF omP.l .mxµ,Eea,oP� :I;zS 17 aDro cPOPo sEexEPi-_ roa oDxO ,Bw HOx.aeLEI [4321 VIEW 7- ANGLED BRACE CONNECTION [G2I VIEW B- U43OLT BRACE CONNECTION ((G22I1VIEW B- SIDE DOOR OF APPLICABLE) bE1'AIL (IF APPUCABLEI LEFT SIDE -SEE SHEET IF11 FOR ELEVATION VIEW P :Ma 1 RIGHT SIDE - SEE SHEET IFII FOR ELEVATION VEIN I ISMIT ' - -- L, Erecting the Truss Frame CASE NAME' GRAPEVINE CRICKET FIELDS CASE NUMBER. CU -15-47 LOCATION:3451 FOXFIRE LANE: LOT 1BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE. STET 8 OF 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES 80'x120' TENT STRUCTURE aErtaTsroN�ruvcRrz sn[oF4 MCEss rgiEO i F .• D�FEm%TF ax TYPIrwLGMF s=+.we rnxFlsxml asxrwenv rvuuecxcrvm OsrtonTlwtF - o -i ___ SR F E �___�� Ix RenEnexwo [G3I VIEW 2 -TYPICAL CABLE F- CONNECTION DETAIL EFT fD,IFaReeYMAMERN. A aEFE l,.-w•TtwxEu.—TH MME creLE r' ur v nAx x x m x,me ru 1m xic,mo. �... Tt0'G^BlE SIEEYE [G3I VIEW T- CABLE SKU PER SPAN- -_- tzuac 1 /r'zcrac*HIrotE [G3]VIEW 3- (- --- CABLEASSE"I, ! / STD ^moo=__ �,/ �nTTxESE UTFwu etuCEs� `` � I vM TrMaE / n �w ICfI—BAY—SE ., to stwxL[fD'Pl__ >'t — Inrz. x.� UTERUS (G31 VIEW 4- SWAY CABLE LOCATIONS [G31 MEW 5- SWAY CABLE DETAILS IG3I CAB LE TYPICAL SWAY FOUNDATION NOTES: ESAPCD DOES NDT PRONDE ANY IMTERIAL OR OESIGN CRITERIA FORTHE CREATNIN OF THE FOUNWTgN OF THIS WILDING, UNLESS OTHERWISE NOTED, SDU�ND�ATIIO�N S� BBERENGINEERED ANDAPPROVED BY A LICENSED FOUNDATION MUST MEET THE BUILDING REACTION DATA6HOWN BELOW. SEE ENDY-L DRAWINGS FOR ENO—L REACTIONS (IF APPUCASLE) oommmm �m�� m Cm==®�� o===®®®m �.w��1 A WPT004WS DETAILS (IF APPLICABLE) ( 1 _rte r tsa.IF,Rx:wEw .. Io I� BPO62M DETAILS �� rz uFEa ,+'au�sE,Fa>ww. EH.en AMx�a c� xeaN'•I OJNRFYrvE 9r nEiE �f•i F I �ErowuF � 14r LF �J w.LE GASE NUMBER:CUe'Se47munel neI_w LOCATION:3451 FO%FIRE LANE; LOT 1 BLOCK 1 GRAPEVINE CRICKET FIELDS ADDITION MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET 9 Of 9 APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. DEPARTMENT OF DEVELOPMENT SERVICES 80'x120' TENT STRUCTURE