Loading...
HomeMy WebLinkAboutSP2022-11February 3, 2023, 2022 Structures & Interiors, Inc. Skylar Fallis 1594 Hart St. Southlake, TX 76092 Re: GRAPEVINE FILE # SP22-11; 1601 Lancaster Drive To Whom It May Concern, This letter is to verify that your site plan located at 1601 Lancaster Drive, platted Clearview Park Addition, Block 3, Lot 1 R for an addition of a generator was approved by staff on February 2, 2023. A copy of the approved site plan is enclosed. Any changes to a site plan approved with a conditional use or a special use (no matter how minor or major) can only be approved by city council through the public hearing process. Please do not hesitate to contact us if we may be of further assistance (817) 410-3155. Sincerely, AA� ��� , G Erica Marohnic, AICP Planning Services Director Planning Services The City of Grapevine * P.O. Box 95104 * Grapevine, Texas 76099 * (817) 410-3155 * https://bit.lv/GravevineF ianninLi REMODELING FOR 601 LANCAS I ER DRIVE GRAPEVINE, TEXAS PLANNING APPROVED BUILDING CODES 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL PLUMBING CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FIRE CODE 2005 NATIONAL ELECTRICAL CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODI OCCUPANT LOAD CALCULATIONS OCCUPANCY SO. FT. LOAD FACTOR NO. OF OCCUPANTS WAITING ROOM 519 1 `, SO. FT 35 CONTACTINFORMATION OUTPATIENT AREA 4742 1(10 SQ.FT. 48 ARCHITECT BUSINESS AREA 2432 100 SO, FT 25 BUSINESS: TMA-CHA ARCHITECTS, INC. ADDRESS: 814 PENNSYLVANIA AVE., SUITE 100 FORT WORTH, TEXAS 76104 TOTAL 7693 108 OFFICE NUMBER: 817.737.0404 FAX NUMBER: 817.737.0401 PROJECT SUMMARY M.E.P. ENGINEER BUSINESS: NOVA ENGINEERING ADDRESS: 4819 STATE HWY 121 #12 EXISTING 1ST FLOOR 1.'825 SQ.FT. THE COLONY, TEXAS 75056 OFFICE NUMBER: 817.336-0543 EXISTING 2ND FLOOR 1 1690 SQ.FT. CIVIL ENGINEER BUSINESS: GATEWAY ENGINEERING, INC. TOTAL 2.4515 SQ.FT. ADDRESS: 6012 REEF POINT LANE FORT WORTH, TEXAS 76135 OFFICE NUMBER: 866-936-8302 REMODELED ASC AREA 4742 SQ.FT. REMODELED BUSINESS & WAITING AREA 2951 SQ.FT. INDEX OF DRAWINGS TOTAL REMODELED AREA r 093 SQ.FT. COV COVER SHEET CIVIL C1_ _ ® C2 EXISTING GRADING &DRAINAGE PLAN ARCHITECTURAL A0.1 SITE PLAN A1.1 FLOOR PLAN, ROOM FINISH SCHEDULE A1.2 FLOOR PLAN DIMENSIONS, DOOR & WINDOW TYPES A1.3 REFLECTED CEILING PLAN, DOOR & WINDOW DETAILS A1.4 INTERIOR ELEVATIONS A1.5 INTERIOR ELEVATIONS RK DETAILS ® aA2.=1EXTERlOR ELEVATIONS L1 .1 EXISTING LANDSCAPING PLAN MECHANICAL MEP1.00 COVERSHEET - MEP MEP1.02 SITE PLAN - MEP M2.01 FLOOR PLAN - MECHANICAL M4.01 SCHEDULES AND DETAILS - MECHANICAL M5.01 SCHEDULES AND DETAILS - MECHANICAL ELECTRICAL DE2.01 DELETED E2.01 FLOOR PLAN - ELECTRICAL E4.01 SCHEDULES AND DETAILS - ELECTRICAL E4.02 SCHEDULES AND DETAILS - ELECTRICAL E5.01 SCHEDULES - ELECTRICAL E5.02 SCHEDULES - ELECTRICAL EL2.01 FLOOR PLAN - LIGHTING ES2.01 FLOOR PLAN - SPECIAL SYSTEMS PLUMBING P2.00 DELETED P2.01 UNDERFLOOR PLAN - PLUMBING P2.02 DELETED P2.03 FLOOR PLAN - PLUMBING P2.04 MEDICAL GAS FLOOR PLAN - PLUMBING P4.01 DETAILS - PLUMBING P5.01 SCHEDULES DETAILS & RISERS FP1.01 FIRE PROTECTION PLAN - PLUMBING ACCESSIBILITY 1 TAS REGULATIONS ACCESSIBILITY lAS REGULATIONS ACCESSIBILITY 3 TAS REGULATIONS NOTE: TAS ACCESSIBILITY DRAWINGS ARE NOT PROVIDED BY TMA-CHA ARCHITECTS, BUT ARE BEING PROVIDED FOR CONTRACTORS REFERENCE. ADHERING TO THE REQUIREMENTS OF THE FOLLOWING SHEETS SHOULD BE INCLUDED IN THE CONTRACTOR'S SCOPE OF WORK OCCUPANCY TYPE: B CONSTRUCTION TYPE: TYPE II B VICINITY MAP NORH C! OF GRAPE' rti't APPV' DENIED CASE #_S = - ORDINANCE # DATF FER n 12 21 Ir 0 LL 0 z LLI 0 0 LI cr U U) 5/11 /2022 LU > U M < C) X rr L1 L1JF-- _ 1i1 `/) z Q U > zW �Q r o C� c0 r PDF REPRODUCTION CONTROL: m 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: COVER SHEET DATE: 14 DEC 2022 DRAWN BY: TMA PROJECT NO, 2027 SUBMITTAL: 1. 10 29 APR 2022 2. ® 9 JUN 2022 3. ® 29 JUL 2022 4. A 10 AUG 2022 5. A 16 AUG 2022 cov 6. A 14 DEC 2022 SITE PLAN DATA SUMMARY TABLE (ITEM REQUIRED PROPOSED GENERAL SITE DATA ZONING (FROM ZONING MAP) PO PO LAND USE (FROM ZONING ORDINANCE; INCLUDE ALL APPLICABLE USES) PRC)FESSIONALOFFICES PROFESSIONAL OFFICES TOTAL LOT AREA ( SQUARE FEET AND ACRES) 10O00 SQ FT .22956 ACRES 77949 SOFT 1.789 ACRES FIRST FLOOR BUILDING FOOTPRINT AREA (SQUARE FEET) 46769 SQ.FT. 12825 SQ.FT. TOTAL BUILDING AREA (SQUARE FEET) 93538 SQ.FT. 24515 SQ.FT. BUILDING HEIGHT (FEET: # OF STORIES) 30i 2 STORIES 29'-6" 2 STORIES I FLOOR AREA RATIOS (X.XX.1) OPEN STORAGE (SQUARE FEET) 0 SQ.FT. 0 SQ.FT. PARKING PARKING RATIO (PROM ZONING ORDINANCE) (1 PER 300 SQ. FT.) 82 107 .ACCESSIBLE PARKING (# OF SPACES) 5 5 LANDSCAPE PLAN DATA SUMMARY TABLE ITEM I REQUIRED (PROPOSED LANDSCAPE AREA LANDSCAPE PERIMETER AREA (SQUARE FEET) 77949 SQ. FT. INTERIOR LANDSCAPE AREA - PARKING LOT LANDSCAPING (SQUARE FEET) 4337 SO. FT. 5168 SQ. FT. ADD(T ION.AL INTERIOR LANDSCAPE AREA 16583 SO. FT. OTHER LANDSCAPE AREA W':TH<N THE LOT (SQUARE FEET) IMPERVIOUS AREA BUILDING FOOTPRINT AREA (SQUARE FEET) 12825 SQ. FT. AREA OF SIDEWALKS. PAVEMENT & OTHER IMPERVIOUS FLATWORK 43373 SQ. FT. (SQUARE FEET'I OTHER IMPERVIOUS AREA TOTAL OPEN SPACE (SQUARE FEET AND PERCENTAGE) 15590 SQ. FT (20% MIN). 21751 SO. FT. (27.9%) TOTAL !MPERVOUS AREA ( SQUARE FEET AND PERCENTAGE) 62359 SQ. FT. (80% MAX). 56198 SQ. FT. (72.1%) TABLE 1. MAXIMUM PERMISABLE SOUND PRESSURE LEVELS BY RECEIVING ZONING DISTRICT La SOUND LEVEL, dBA LIMITS FOR CONTINUOUS SOUND SOURCES DISTRICT DAY 1 IME NIGHT TIME (7:00 AM TO 10.00 PM) (10:00 PM TO 7:00 AM) RESIDENTIAL 59 52 EXISTING EXTERIOR LIGHTING EXISTING PARKING LOT LIGHTING REMAINS AND DOES NOT EXCEED 3.0 FOOTCANDLES AT PROPERTY LINE. ON EAST PROPERTY LINE ADJACENT TO RESIDENTIAL, LiGHTINGDOES NOT EXCEED 0.2 FOOTCANDLES. EXISTINS FIRE HYDRA►IT 2(` INLETS j \'i l I I EXISTING 8" CITY j WATER MAIN I j 9 I y 1 y II I EXI ING 8" i SEVR MAI y l h I I I I ) I i I I I ! I i I I I � I I � I I \�j I I y i y i 4 I I II EXISTING 6" WATER SERVkE ,, i I / i I > i I I � EXISTIN 3 FIRE ) HYDRANT j I !I II r I I I i I I i I i I i I I > i I EXISTING SEWER MANHOLE 20' CURB I WEST COLLEGE STREET INLET l 8" SEWER 1 8" SEWER -- -------,-,�� ` n 1 tf ' I I j 42" STORMI i I I—� r -� EXISTING SEWER SERVICE I I I I 10 I 1 18" SD I I I20' INL.ET i s I 5 TOTAL LOT AREA - 7794 SQ.FT. 1 I I I CLEARVIEIN PARS I I ( I I LOT 1 R E (LOCK I I 1601 LANCA,iTER D IVE 10' INLET I I CITY OF GI?APEVI E TARRANT COUNTY, TEXAS EXISTING` PARKING COVER 27" SD "EXISTING GROUND SIGN a I (6-3" HIGH) - j 6 I \ I I I ( i I 1 ,,—EXISTING 3" i i C0 I I I j i cd STORM DR IN 1 1 6:D Z I I M I EXISTING FIREI LA CITYI I Q❑ � � I I EXISTING ENTRANCE iUT:LITr I IN i = I GATE ISLAND z Y I I I JASEM141 i OVQ I I I 1 EXISTING FIRE LANE STRIPING v c9 w j I i t I cf) zI10 o I I ra�C, I z j E(ISTIN_; GROUND I )1UN 1 X I I f "`4 (?'-7" H'GH) I 12 w I I! I 6'X5' BOX W( i I I f o 0 I I LOT 14, BLOCK A, I i s z COLLEGE CREEK LOT 15, BLOCK A, COLLEGE CREEK ZONING: R-7.5 (SINGLE FAMILY DISTRICT) I w w; I I ! ZONING: R-7.5 (SINGLE FAMILY DISTRICT) I r6" FIRE LINE i z z I FDC ON BLDG FACE g g I LLB PER FIRE SPRINKLER ¢ LL I � = i 1 DRAWINGS z z Q I �X z I EXISTING TWO _ rO w I w Q I • STORY MEDICAL J 1 OFFICE BUILDING j Z 1 E (ISTING i EL TRANCE 1 — fw TOTAL EXISTING STORIES 2 NOPY ; I I I LOT 13, BLOCK A, TOTAL EXISTING HEIGHT - 24'-6" I f- FIRST FLOOR SQ. FT. - 12825 ------ I I COLLEGE CREEK I `�1 EXISTING 4.2" SECOND FLOOR SO. FT. - 11690 I MIN. RE R-- WATER METERS TOTAL SQ.FT. - 24515 I I ZONING: R-7.5 (SINGLE FAMILY DISTRICT) I � I � I 1 ' 25' MIN- FFONT WARIT 624F 1 I I = I I I I 113 I I I Iall.A2.1 SIM OHI I I I I I 5 clI U LOT 12, BLOCKA, v t� I COLLEGE CREEK w— ccI 111 � i 26'4a a Q I I ZONING: R-7.5 (SINGLE FAMILY DISTRICT) I L-NEW SCREEN 8, Q Z FENCE m� a co I � UY I I zo i I I 4 1 I W I �0RA;NAG JTILI tpbwANT I � I I1 li I 5 ay ie-rcw cA i LOT 11, BLOCK A, (y COLLEGE CREEK i ( j I EXISTING F I4#� IPING = I j EXISTING ENTRANCE EXISTING BRICK I i ZONING: R-7.6 (SINGLE FAMILY DISTRICT) j I I GATE ISLAND WASTE ENCLOSURE I aq2., (T-9" HIGH) 112 i I i I i E (ISTIN 3 FIRE LAI JE_STRIPING I 1 ' I 4X4'INLET I I -EXISTING GROUND SIGN 'r V 10' MIN. SIDE YARD I 1 2'-7" HIGH)9iA' `.5 I i LOT 10, BLOCK A, — --- — ---- r----------- — — I COLLEGE CREEK I u I * II . • _ 'RaA' NE90,a', 2'E I n I h i I j ZONING' R-7.5 (SINGLE FAMILY DISTRICT) 1605 LANCASTER DRIVE II u I I _ al EVERGREEN FERN LTD j --- LOT 3R, BLOCK 3, ! CLEARVIEW PARK ADDITION j ZONING: PO (PROFESSIONAL OFFICE DISTRICT) I I I I 1 y0 II I I b9a �I 1 PLAN NORTH SITE PLAN T 1 1 LLJ W J m A 15' 30' GRAPHIC SCALE 150' SCALE: 1 " = 30'-0" W COLLEGE ST Lr w OXFORD LN co SITE U z ir g p EATON LN Y - I= m W HUDGINS ST pu X m O m a A E Yv'OODXS A 1R. / NORTH VICINITY MAP CASE NAME: NEXTMED CASE NUMBER: SP22-11 LOCATION: 1601 LANCASTER DRIVE CITY OF GFE, ,hE CENIEO ORDINANCE # DATF FEB 0 3 2023 ARCHITECT: TMA-CHA ARCHITECTS 814 PENNSYLVANIA AVE. FORT WORTH, TEXAS 76104 JOHN REESER PROJECT ARCHITECT 817-737-0404 JOHN@TMA-CHA.COM OWNER: DR. NATHAN GRAVES 1601 LANCASTER DRIVE GRAPEVINE, TEXAS 76051 817-481-7727 MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES PLANNING SERVICES DEPARTMENT SITE PLAN FOR NEXTMED ASC LOT 1 R, BLOCK 3, CLEARVIEW PARK CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.789 ACRES ZONE: P-O PROFESSIONAL OFFICE DISTRICT DATE OF PREPARATION: DECEMBER 12, 2022 U U) w > cr_ < cf) �W W w oZ U z > W W T 12/14/2022 .PDF REPRODUCTION CONTROL: 0 il 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: SITE PLAN DATE: 14 DEC 2022 DRAWN BY: TMA PROJECT NO. 2027 SUBMITTAL: 1. 2. 3. AO m 1 12 61 ~n / UJI .......... HARDI-SLATE ROOF, TYPICAL -TIE' . ........... . _111C - EIFS, TYPICAL r rr NOTE: GENERATOR EXHAUST IS O FLUSH W/ TOP OF UNIT w o Luu z �a T —LINE OF QU)Locr0 12 w'Q GENERATOR wwOwcn 6 , w`♦ O �" II BEYOND m a- cc >O r LINE OF o �° �T r Q Q Q c Q} CONDENSER _ O Ir I a~ BEYOND, TYP. w o C\i7�� o �z I �jLLj o w Co >I �c> LL m ` SOUTH ELEVATION Lo C7--2 X 10 CAP Q SECONDFLR.`` EQUIPMENT SCREEN � J O Q � 1/8" = 1'-0" NORTH ELEVATION SIM O.H. N N FINISH GRADE ♦ -1Q w EIFS, TYPICAL— r cc � o o �N, NOTE: SLOPE FENCE TO FOLLOW o � i w —LINE OF o w ` , EXIST. GRADE. ALL WOOD TO BE i Q z GENERATOR mA -___.. ..____. __._......... _._._._._ WI FIRST FL BETTER R c\, B z 20 g GRADE CEDAR OR BE _....._..._ _....__.._.. k—T, _._--.---...-_____._.__ ___ _. ,. I EY w � QUAmE GALV. FENCE ONDS, TYPICAL N O� H ELEVATION TOTAL SQ.FT. OF FACE = 1,526 SQ.FT.— -__ �1 I — _ o 0 0 POST @ 6=0 O.C. MAX. f 0 w -_ 1 — I. GLASS 540 SQ.FT. = C7 z LL U) 1/8 — 1 -0 E.I.F.S. 906 SQ.FT. I O a wc�l = CAST STONE 80 SQ.FT. I z = J L2, ;-: 2 X 4 NAILERS , TYP. 0o O C7 Q o U LLJ > = WEST ELEVATION 60 co 1 X 6 CEDAR @ 7" O.0 EA. SIDE. r STAGGER TO CONCEAL VIEW. w = 06 EQUIPMENT SCREEN = _ PROTECT EXIST. CONC. PAVING 1 /8+I � = 1 -0 a L� _ FROM DAMAGE HARDI-SLATE ROOF, TYPICAL - HIGHER SCREEN 12 a BEYOND 0D �C" 12" DIAM. 6 w CONC. Q 0 ♦ u 2 �' SQUARE GALV. FENCE wQ -0" POST @ 6=0" O.C. MAX. w Co 1 Z - co p 00 NOTE: ALL WOOD TO BE STAINED NO. 1 GRADE WESTERN RED CEDAR OR BETTER SECTION TH RU SCREENING ,> EAST ELEVATION 12 " = , „ EQUIPMENT SCREEN ''8 —1-° � 7 � — SIM._ AS NOTED j( jI II 12A - �� II—IL�LI� �.. — �� /1��� 1 /8 — 1 0 — _ EXISTING STEEL GATES ...... ...... ..........._L._... i .... A.. � I 1 ( I ! IV_ CAST STONE CAST STONE COLUMNS, TYPICAL EIFSTYPICAL CAST STONETYPICAL , , EIFS, TYPICAL EXISTING TOTAL SQ,FT. OF FACE = 2,220 SQ.FT. EAST ELEVATION GLASS 520 SQ.FT. 2 E.I.F.S. 1340 SQ.FT. 1 /8 = 1 -0 CAST STONE 360 SQ.FT. — HARDI-SLATE ROOF, TYPICAL ♦ SECOND FINISH GRADE EEIFS, TYPICAL IFS. TYPICAL co 1'RST FLR. EXISTING SOUTH ELEVATION 3 , 1 /8"= 1 -0 HARDI-SLATE ROOF, TYPICAL r I EIFS. TYPICAL EIFS: TYPICAL EXISTING (4) VV E .. T_ _E�LEVAT 10�1� 1 /8 = 11 .-0" r 1 EIFS, TYPICAL I I STANDING SEAM METAL ROOF - .......... r r E E ' ... _...i..._.. I i ! I : EIFS, TYPICAL CAST STONE, TYPICAL TOTAL SQ.FT. OF FACE = 1,526 SQ.FT. GLASS 540 SQ.FT. E.I.F.S. 906 SQ.FT. CAST STONE 80 SQ.FT. 12 16 I _.l L� CAST STONE COLUMNS, TYPICAL a o w `° m t-� 1 TOTAL SQ.FT. OF FACE = 1,388 SQ.FT. GLASS 428 SO. FT. E.I. F.S. 960 SQ.FT. SECOND FLR ` — Lo bo o FINISH GRADE., FIRST FLR. BRICK NORTH ELEVATION — EXISTING 0WASTE ENCLOSURE 8 II," 1 /8 -— 1 -0 i CAST STONE BRICKFitt 1 �'��§'-`'fx:�'"nx-•::'a.�.',x,.'-� �t'"-��: ..a SOUTH ELEVATION — EXISTING 9 WASTE ENCLOSURE II_,II - CAST STONE BRICK 0' 8' 24' GRAPHIC SCALE SCALE: 1/8" = V-0" W COLLEGE ST OXFORD UN x SITE m 0 EATON LN lJ ti m y� HUDGINS 51 r- jj Q ,pAE��OODs pyE / NORTH VICINITY MAP EAST ELEVATION — EXISTING WASTE ENCLOSURE 1 /8 — 1 -0 CITY OF Girhrc:riit APPV'D,..,®„ CASE CAST STONE r,� •, - ORDINANCE � '�� BRICK DATF FEM 2023 WEST ELEVATION —EXISTING WASTE ENCLOSURE 101 „_ — , 1 /8 1 -01 1 TABLE OF PERCENTAGES - TOTAL BUILDING 30% GLASS 47% E.I.F.S. 23% CAST STONE ARCHITECT: TMA-CHA ARCHITECTS 814 PENNSYLVANIA AVE. FORT WORTH, TEXAS 76104 JOHN REESER PROJECT ARCHITECT 817-737-0404 JOHN@TMA-CHA.COM OWNER: DR. NATHAN GRAVES 1601 LANCASTER DRIVE GRAPEVINE, TEXAS 76051 817-481-7727 CASE NAME: NEXTMED CASE NUMBER: SP22-11 LOCATION: 1601 LANCASTER DRIVE MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES PLANNING SERVICES DEPARTMENT EXTERIOR ELEVATIONS FOR NEXTMED ASC LOT 1 R, BLOCK 3, CLEARVIEW PARK CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.789 ACRES ZONE: P-O PROFESSIONAL OFFICE DISTRICT DATE OF PREPARATION: DECEMBER 12, 2022 40' 12/14/2022 PDF REPRODUCTION CONTROL: \.J 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: EXTERIOR ELEVATIONS DATE: 14 DEC 2022 DRAWN BY: TMA PROJECT NO. 2027 SUBMITTAL: 1. 2. 3. A2m 1 W COLLEGE ST OXFORD LN r m x EATON LN W f ItJpGWS. __. N r VICINITY MAP UTILITY CONSTRUCTION NOTES 1. CONTRACTOR SHALL OBTAIN A PARKWAY PERMIT FOR ANY WORK WITHIN THE CITY OF GRAPEVINE RIGHT-OF-WAY. 2. CONTRACTOR SHALL REVIEW THE SITE MECHANICAL AND PLUMBING PLANS PRIOR TO ANY CONSTRUCTION TO INSURE THAT THE PROPOSED UTILITIES SHOWN ON THESE PLANS ARE IN PROPER ALIGNMENT AND DEPTH. 3. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS OF THE CITY OF GRAPEVINE, TEXAS. 4, CONTRACTOR SHALL BE REQUIRED TO PROVIDE AND MAINTAIN ALL NECESSARY WARNING AND SAFETY DEVICES (FLASHING LIGHTS, BARRICADES, SIGNS, ETC.) TO PROTECT THE PUBLIC SAFETY AND HEALTH UNTIL THE WORK HAS BEEN COMPLETED AND ACCEPTED BY THE CITY. 5. ALL PIPES SHALL BE KEPT FREE OF TRASH AND DIRT AT ALL TIME. AT THE END OF EACH DAY, THE PIPE SHALL BE TEMPORARILY SEALED/CONNECTED. ALL PIPE INSTALLATION SHALL BE PERFORMED AS RECOMMENDED PER THE PIPE MANUFACTURER. THE CONTRACTOR SHALL INSPECT THE SITE DAILY AND KEEP THE SITE FREE OF TRASH AND CONSTRUCTION DEBRIS. 6. THE CONTRACTOR SHALL CONTACT THE ASSIGNED INSPECTOR FOR THE OPERATION OF ALI- WATER VALVES & SCHEDULING OF SERVICES BY WATER/WASTEWATER. 7. WATER PIPE FOR FIRE LINE SHALL BE POLY VINYL CHLORIDE (PVC) PIPE CONFORMING TO AWWA C900 CLASS 150 AND SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS, OR APPROVED EQUAL. MINIMUM 42 INCH COVER REQUIRED. 8. PROVIDE THRUST BLOCKING ON WATER PIPING PER NCTCOG SPECIFICATIONS. 9. WATER PIPE SMALLER THAN 4 INCHES SHALL BE POLY VINYL CHLORIDE (PVC) SCHEDULE 40 AND INSTALLED PER MANUFACTURER'S REQUIREMENTS, OR APPROVED EQUAL. 10. ALL ON -SITE WATER PIPE 4 INCH AND LARGER SHALL BE CHLORINATED AND TESTED BY AN APPROVED AGENCY AND - PLUMBING SECTION (AWWA C-601). 11. INSTALL WATER PIPE TO PROVIDE 12' MIN. CLEAR OF ALL PROPOSED AND EXISTING PIPING. 12. THE CONTRACTOR SHALL MAINTAIN THE EXISTING WATER MAINS AND SERVICES IN OPERATION WHEN INSTALLING NEW WATER MAINS. THIS SHALL INCLUDE ANY TEMPORARY CONNECTIONS, IF REQUIRED. 13. ALL TRENCHES SHALL BE BACKFILLED AND REPAIRED PER CITY STANDARDS. LINETYPE LEGEND EXISTING PROPOSED -- -- CENTERLINE ... -...... _........ .......__.-...-- EASEMENT - PROPERTY LINE ...... ...-....... — — — — — — — RIGHT-OF-WAY 0 CHAIN LINK FENCE _ ......;...:::.�:.:. I CURB AND GUTTER - --- - - - EDGE OF PAVEMENT S-24" SS SANITARY SEWER D 24" SD STORM DRAINAGE V W WATER ABBREVIATIONS AB AGGREGATE BASE LF LINEAR FEET AC ASPHALT CONCRETE MH MANHOLE BFP BACKFLOW PREVENTER OC ON CENTER BFR BARRIER FREE RAMP P PAVEMENT BM BENCHMARK R RADIUS CL CENTERLINE ROW RIGHT-OF-WAY CID CONTROL POINT SD STORM DRAIN DI DRAIN INLET SF SQUARE FEET DWG DRAWING SL STREET LIGHT EC EDGE OF CONCRETE S SEWER EP EDGE OF PAVEMENT STA STATION FF FINISH FLOOR STD STANDARD FG FINISH GRADE TBM TEMPORARY BENCHMARK FH FIRE HYDRANT TC TOP OF CURB FL FLOW LINE TYP TYPICAL GB GRADE: BREAK W WATER L.A.LANDSCAPE AREA WM WATER METER NOTES 1. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 2. WHERE UNDERGROUND OR SURFACE STRUCTURES ARE SHOWN ON THE PLANS, THE LOCATIONS, DEPTH AND DIMENSIONS OF STRUCTURES ARE BELIEVED TO BE REASONABLY CORRECT, BUT ARE NOT GUARANTEED. SUCH STRUCTURES ARE SHOWN FOR THE INFORMATION OF THE CONTRACTOR, BUT INFORMATION SO GIVEN IS NOT TO BE CONSTRUED AS A REPRESENTATION THAT SUCH STRUCTURES WILL, IN ALL CASES, BE FOUND WHERE SHOWN OR THAT THEY REPRESENT ALL THE STRUCTURES THAT MAY BE ENCOUNTERED. 3. CONTRACTOR SHALL NOTIFY "USA" (UNDERGROUND SERVICE ALERT) AT 811, TWO WORKING DAYS BEFORE COMMENCING EXCAVATION AND ALL UTILITY AUTHORITIES OR UTILITY COMPANIES HAVING POSSIBLE INTEREST IN THE WORK, OF CONTRACTOR'S INTENTION TO EXCAVATE PROXIMATE TO EXISTING FACILITIES, AND CONTRACTOR SHALL VERIFY THE LOCATION OF ANY UTILITIES WITHIN THE WORK AREA. 4. WHEN THE CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OF EXTENSION OF EXISTING SURFACE OR SUBSURFACE STRUCTURES, PIPES, OR APPURTENANCE, THE CONTRACTOR MUST VERIFY EXISTING LOCATION AND ELEVATIONS OF ITEMS SHOWN ON THE PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS, IN WRITING, BEFORE COMMENCEMENT OF WORK. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY QUESTIONS THAT MAY RISE CONCERNING THE INTENT, PLACEMENT, OR LIMITS OF DIMENSIONS OR GRADES NECESSARY FOR THE CONSTRUCTION OF THIS PROJECT. EXISTING SEWER MANHOLE -- 20' CURB INLET SD SD 5D SD SD SD SD SD COLLEGE STREET 8' SEWER �; sa S 6'x5' Box SID — — o sue. ••�..r�.... ��...� u••n r.••.... m•-.••a....�..� ..� �.....� .... ..-r..r . Y.._ . .. F__ �' //'�V PROPERTY LINE.. 1 N------ - SD7 42" STORM I EXISTING FIRE Q SD SD SID I HYDRANTrI N 20' INLET I i 18" SD 20' INLET / EXISTING SEWER SERVICE o � z N �U) ® 10' INLET � 27 SD00 EXISTING 8" CITY si WATER MAIN io �1 cif 1 20' DRAINAGE o EXISTING 30" &UTILITY 1600 LANCASTER DR LANCASTER LIQUID INVESTMENT S STORM DRAIN EASEMENT LOT 11 BR1, BLOCK 1, LLI CLEARVIEW PARK ADDITION ~ ZONING: PO (PROFESSIONAL OFFICE DISTRICT) Q I MA NT1NG 8' CITY SEWER EXIST CONC. PAVING, CURBS, () I SIDEWALKS AND STRIPING Zo J INSTALL 80f LF OF 6" FIRE LINE TO BUILDING. I BACKFILL LINE PER CITY STANDARDS. CONTRACTOR v.. . •r ,••, �a . ° I g SHALL BE RESPONSIBLE FOR REPLACING ALL o _ D BY INSTALLATION. � IMPROVEMENTS DISTURBED �;.... zx............ ..!...11 EXIST ELT, T _..... INSTALL CUT IN TEE WITH 6" cn w._ . _.... FLANGE. COORDINATE WITH A 1 CITY STAFF FOR SCHEDULING SEE BUILDING FIRE SPRINKLER PLANS s N FOR FIRE SERVICE INSIDE BUILDING j F6 DC FDC ON BUILDING FACE PER € a INSTALL 8" IN LINE GATE —� 1 FIRE SPRINKLER DRAWINGS VALVE ON EXISTING WATER o $ LINE PER CITY STD.'S j EXISTING TWO STORY ... ..._. .. — — V MEDICAL OFFICE BUILDING �w WATER ';•• (11569 SQ.FT. PER LEVEL) EXISTS U EXISTING 6 Z SERVICE „- m FF = 647.5 rNTRANPE I J _ FURNISH AND INSTALL 6" DETECTOR ; r ANOP�Y g I CHACK BACKFLOW PREVENTER WITH w o BYPASS AND CONRETE VAULT PER CITY o . m•_.......__� O cc STD. GR4160 OR CITY APPROVED EQUAL. o 3 a i on OKTEX PARTNERS, LTD. 1U) a LOT 1 R, BLOCK 3, EXISTING 4-2" CLEARVIEW PARK oj`e I WATER METERS ADDITION EXISTING FIRE i w ...... o HYDRANT� ._...�.... .�,�,..._ .••._m•••_•. ..•.•..•....... •...•..•.••._.. _.�....... ;;; ��. .� � __.... ............... .�....._..... \...................... .........�..... men.. _ �,� � _ ,.. g .. �. .: 77. a a ? a 1602 LANCASTER DR MER GENERATOR ) LT2 PROPERTIES, LLC LOT 11 BR2, BLOCK 1, CLEARVIEW PARK ADDITION a ZONING: PO (PROFESSIONAL OFFICE DISTRICT) �---EXTSfi-CONC. PAVING, CUd85, 1 SIDEWALKS AND STRIPING o co z cn I a 20 DRAINAGE��o &UTILITY a U) EXIST CONC. PAVING, CURBS, EASEMENT SIDEWALKS AND STRIPING co c a a — — .��.n .�m��. �..a�� m�•aw s..cccTa amA.. � � � n.�m�� ����� — .•A��. �scae wva \ [n 1604 LANCASTER DR I N PROPERTY LINE TROTTER BROOKS ETAL LOT 11 A, BLOCK 1, 1 CLEARVIEW PARK ADDITION I o r — a — — — .. , ..—..• — — — — 1605 LANCASTER DRIVE EVERGREEN FERN LTD ZONING: PO (PROFESSIONAL OFFICE DISTRIC 1) LOT 3R, BLOCK 3, CLEARVIEW PARK ADDITION r,<, °o ZONING: PO (PROFESSIONAL OFFICE DISTRICT) I I t-I 50' MAX. TO MAIN FLANGED COUPLING DETECTOR CHECK METER ADAPTORr VALVE MATH D.I. N�PI E 9b' BYPASS METER MJ x FLANGE .�... ,,:. a *Go 1 FM LINE INSTALLED BY LICENSED FIRE --- -- -- ---� PROTECTION DIRECTION OF FIuOW 1 3ji'VALV� � � I I ,a %"METkR I PENETRATION SHOULD BE 12" ABOVE VAULT FLOOR AND SEALED MATH NON —SKINK VALVE BOX PER J / GROUT DETAIL GR UM Z �36%48* HATCH — HATCH CENTERED MINIMUM, 6'X4'X6' DEEP PRECAST CONCRETE ON CHECK VALVE MEETING OSHA STANDARDS VAULT ON 12' CRUSHED ROCK ITEM 504.2 VAULT SHALL BE HS20 RATED IN TRAFFIC AREAS. DETECTOR CHECK GR4160 BACKFLOW PREVENTER 0 U) 10'x5' BOX 0 SD SD SD — I I I LOT 15, BLOCK A, COLLEGE CREEK 10 U.E. \y LOT 14, BLOCK A, / COLLEGE CREEK ' ZONING: R-7.5 (SINGLE FAMILY DISTRICT) 1 W LOT 13, BLOCK A, > COLLEGE CREEK ( cIf 0 LU ZONING: R-7.5 (SINGLE FAMILY DISTRICT) I Y cIf I 00 LOT 12, BLOCK A, COLLEGE CREEK ZONING: R-7.5 (SINGLE FAMILY DISTRICT) LOT 11, BLOCK A, COLLEGE CREEK ZONING: R-7.5 (SINGLE FAMILY DISTRICT) 4'x4' Y INLET LOT 10, BLOCK A, COLLEGE CREEK ZONING: R-7.5 (SINGLE FAMILY DISTRICT) 0 U) —M..8 - —M"8— - - - V/^� t�riArErl��i� CASE 0RDINANCE # " — DATE FES 0 3 2023 ENGINEERING, LLC_I P. 817-78246214924 BOLERO CT. FORT WORTH, Tx N8 ENGI . 0UTL JOOK CONI TPEE F PM F1EG F-' N SCALE IN FEET 0 15 30 60 1' = 30' i W 0 0 2 W cr W 0 t', W W I-- W W Z U> Z W C� L� Q T ♦o 0 W T % i z� o o °°°°°°°°°°° MATHEW E WILLU MSOM °° °°°°°°°°°°°°°°°°°°°°°°°° 00 119947 11 /14/2022 PDF REPRODUCTION CONTROL: ill 0 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: UTILITY PLAN DATE: DRAWN BY: TMA PROJECT NO.: 2027 SUBMITTAL: 1. 2. 3. ci 111 NOTES 1. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 2. WHERE UNDERGROUND OR SURFACE STRUCTURES ARE SHOWN ON THE PLANS, THE LOCATIONS, DEPTH AND DIMENSIONS OF STRUCTURES ARE BELIEVED TO BE REASONABLY CORRECT, BUT ARE NOT GUARANTEED. SUCH STRUCTURES ARE SHOWN FOR THE INFORMATION OF THE CONTRACTOR, BUT INFORMATION SO GIVEN IS NOT TO BE CONSTRUED AS A REPRESENTATION THAT SUCH STRUCTURES WILL, IN ALL CASES, BE FOUND WHERE SHOWN OR THAT THEY REPRESENT ALL THE STRUCTURES THAT MAY BE ENCOUNTERED. 3. CONTRACTOR SHALL NOTIFY "USA" (UNDERGROUND SERVICE ALERT) AT 811, TWO WORKING DAYS BEFORE COMMENCING EXCAVATION AND ALL UTILITY AUTHORITIES OR UTILITY COMPANIES HAVING POSSIBLE INTEREST IN THE WORK, OF CONTRACTOR'S INTENTION TO EXCAVATE PROXIMATE TO EXISTING FACILITIES, AND CONTRACTOR SHALL VERIFY THE LOCATION OF ANY UTILITIES WITHIN THE WORK AREA. 4. WHEN THE CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OF EXTENSION OF EXISTING SURFACE OR SUBSURFACE STRUCTURES, PIPES, OR APPURTENANCE, THE CONTRACTOR MUST VERIFY EXISTING LOCATION AND ELEVATIONS OF ITEMS SHOWN ON THE PLANS PRIOR TO CONSTRUCTION. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS, IN WRITING, BEFORE COMMENCEMENT OF WORK. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY QUESTIONS THAT MAY RISE CONCERNING THE INTENT, PLACEMENT, OR LIMITS OF DIMENSIONS OR GRADES NECESSARY FOR THE CONSTRUCTION OF THIS PROJECT. GRADING NOTES 1. ALL GRADING IS EXISTING. NO GRADING AND/OR DRAINAGE IMPROVEMENTS PROPOSED WITH THESE PLANS. 00 — SD SID I S EXISTING FIRE f HYDRANT EXISTING SEWER MANHOLE — 20'; CURB INLET D SD SD SD SD SID i SO LOT 15, BLOCK A, COLLEGE CREEK 10' U.E. \ \\ EXISTING 8' CITY SEWER I \ DNING: PO (PROFESSIONAL OFFICE DISTRICT)% MAIN EXIST CGNC. PAVING ;CURBS, \ \ SIDEWALKS AND STRIPING cc I ' W Z Q J EXISTING 6" WATER SERVICE ............. R z EXISTING FIRE C HYDRANT 1602 LANCASTER DR LT2 PROPERTIES, LLC LOT 11 BR2. BLOCK 1. CLEARVIEW PARK ADDITION I" '-ONING: PO (PROFESSIONAL OFFICE DISTRICT) 0 3 — _ — oo a I 1604 LANCASTER DRY 1= TROTTER BROOKS ETAL LOT 11 A, BLOCK 1, CLEARVIEW PARK ADDITION NG: PO (PROFESSIONAL OFFICE DISTRICT) > 0 0 "a E COLLEGE STREET 8' SEWER SD_ i-- s'xs' Box —s— —s— -� —s— �s—— SD £ . - "._. ....._._._._ _.."._..... _ OPERTY LINE I ....._— w I I STORM E3--- SD f SLi.._ SD SD — — — — — - - 20' INLET I 18 SD € 20' INLET ? ®� '`—� EXIStING SEWER SERVIC' E cn I r: i P 10' INLET I I` 27 SD a, a0Lij EXISTING 8' CITY WATER MAIN ,,r_. i ..L...a „ 120' DRAINAGE ' I EXISTING 30 w rn I & UTILITY 1600 LANCASTER DR Lw N STORM DRAIN °D EASEMENT LANCASTER LIQUID INVESTMENTS LOT 11BR1, BLOCK 1,00 CLEARVIEW PARK ADDITION I Go I I cn i .,aae''mm- a xea,.'a �aa� aaw� .awe a><.w� dw aama "... •.,•„\wawa .a`, n o _ PXIST ELE T' LOT 14, BLOCK A, \ ....."n.� a...".....w ;................ ................ ................ ." I .; COLLEGE CREEK f° `• i I '� U) ZONING: R-7.5 (SINGLE FAMILY DISTRICT) , p ? EXISTING TWO STORY MEDICAL OFFICE BUILDING N (11569 SO. FT. PER LEVEL) i pj m o FF � 647.5 w �4 I XISTI z N rRANCE Q, CANOFIY c LOT 13, BLOCK A, a- I;' COLLEGE CREEK O OKTEX PARTNERS, LTD. o I I ZONING: R-7.5 (SINGLE FAMILY DISTRICT) cn LOT 1 R, BLOCK 3, I CLEARVIEW PARK E ADDITION 0 cn i Z 1 y� . — � mow..• ��:, >.�•` � ..aa. �...a� II :n co ell � �, � I u " _ LOT 12, BLOCK A, g �DER. GENERATOR ? � I i COLLEGE CREEK o INDICATES EXISTING CONTOURS tI ZONING: R-7.5 (SINGLE FAMILY DISTRICT) -r_ONC. PAVING, CU , °f CD � SIDEWALKS AND STRIPING a a i t '\ LOT 11, BLOCK A, COLLEGE CREEK lft? \; ...aw.w 20' DRAINAGE a do U11LITY EASEMENT EXIST CONC. PAVING, CURS, ZONING: R-7.5 (SINGLE FAMILY DISTRICT) SIDEWALKS AND STRIPING .. �c \~ 44' Y �rINLET N �� — _, — ,.,,a .aa... — w.aw. ia.. — L.,�, j LOT 10, BLOCK A; PROPERTY LINE ,I ` COLLEGE CREEK p 3 � . >•�.. �..� ,..aa v� .,:�� �� avww . �•�. ' •� .. ��..��, - LE FAMILY DISTRICT) : 1�a05 LANCASTER DRIVE r \ ZONING: R 7.5 (SING CT) EVERGREEN FERN LTD N.. LOT 3R, BLOCK 3, U) ; CLEARVIEW PARK ADDITION ZONING: PO (PROFESSIONAL OFFICE DISTRICT) \ } 0 cn............Ln y�. ~ '6 ¢4 \ \ \ cl fta: I I p I I co I' i I cn I SD 10'x5' BOX a SD - �--r �I+ �,in�r t� „vE -- 2— �EB 0 3 2023 V m�l - P. 817-782 1 4924 BOLERO CT. FORT WORTH, TX NBM91ENQlI9ON7LOOK.(00rjA 7PBE FIIRN REQ. F-19551 0 SCALE IN FEET 0 15 30 60 1-=30' o o. oosoaoococoocc0000aooa000a0000a0 MATHEW E, VAUJAMM D 000000000c000000000000000000000g o 119947 0° 11 /14/2022 PDF REPRODUCTION CONTROL: 0 �fI �wf 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: EXISTING GRADING AND DRAINAGE PLAN DATE: DRAWN BY: TMA PROJECT NO.: 2027 SUBMITTAL: 1. 2. 3. C 2 WEST COLLEGE STREET LANDSCAPE PLAN DATA SUMMARY TABLE ITEM I REQUIRED 1PROPOSED LANDSCAPE AREA LANDSCAPE PERIMETER AREA (SQUARE FEET) 77949 SQ. FT. INTERIOR LANDSCAPE AREA -- PARKING LOT LANDSCAPING (SQUARE FEET) 4337 SQ, FT. 5168 SQ. FT. ADDITIONAL; NTERIOR LANDSCAPE AREA 16583 SQ. FT. 01 HER LANDSCAPE AREA WITHIN THE LOT (SQUARE FEET) IMPERVIOUS AREA BUILDING FOOTPRINT AREA (SQUARE FEET) 12825 SQ. FT. AREA OF SIDEWALKS, PAVEMENT & OTHER IMPERVIOUS FLATWORK 43373 SO. FT. (SQUARE FEET) OTHER IMPERVIOUS AREA TOTAL OPEN SPACE (SQUARE FEET ANC PERCENTAGE) 15590 SQ. FT. (20% MIN). 21751 SQ. FT. (27.9%) TOTAL IMPERVIOUS AREA( SQUARE FEET AND PERCENTAGE) 62359 SQ. FT. (80% MAX) 56198 SQ. FT. (72.1%) PLAN EXISTING NORTH LANDSCAPE PLAN ` 111 = 20'-0" —LIVE OAK CEDAR CEDAR CITY _ _ _ .DRA NAGE _�_ / -- -- - - ---- - - -- ----- -- P.Al - / CEDAR r CEDAR CEDAR LIVE OAK 1 ¢�EXI3TING Bt�FORD I-JLLY I LIVE OP LIVE OAI: SC 3EENING--4EDGE, PRESS ( 1 II TYPICAL I . 1 IBALD CYPRESS EXISTING BURFORD HOLLY ' SCREENING HEDGE, ( BRADFORD PEAR TYPICAL EXISTING BURFORD HOLLY I �' SCREENING HEDGE, TYPICAL 1—BRADFORD PEAR I I \ EXISTING GROUND SIGN (6'-3" HIGH) j— LIVE OAK b ( BRADFORD PEAR LIVE OAK I t— LIVE OAK I I EXISTING GROUND SIGN I (2'-7" HIGH) LIVE OAK EX STING Bt.RFORD tJLLY SC"IEENINGjHEDGE. TY 'CAL I r I I I I I I LIVE OAK EXISTING TWO STORY MEDICAL OFFICE BUILDING TOTAL EXISTING STORIES - 2 TOTAL EXISTING HEIGHT - 24'-6' FIRST FLOOR SO. FT. - 12825 SECOND FLOOR SO. FT. - 11690 TOTAL SO. FT. - 24515 LIVE OAK I i I •I ' • i it NEW SCREEN FENCE LIVE OAK EXISTING BURFORD HOLLY SCREENING HEDGE, TYPICAL I LIVE OAK —BALD CYPRESS II I I f LIVE OAK BRADFORD PEAR I I I (( A E.lc= I I I I I I I I 1 BRADFORD PEAR I LIVE OAK I i I _ 74" HIGH — BRICK SCREEN WALL �� 1 ON EAST PROPERTY i \ LINE I BRADFORD PEAR I I � 1 I I 1 I � I 1 ❑ I BRADFORD PEAR I I I I 1 � I � I ❑ i I I I I I I I I BRADFORD PEAR 1 d LIVE OAK I j 1 — LIVE OAK I i BRADFORD PEAR LANDSCAPING NOTES 1. EXISTING LANDSCAPE PLAN SHOWS LANDSCAPING AS ORIGINALLY APPROVED BY CITY OF GRAPEVINE AND CONSTRUCTED IN 2001, AND AS IT CURRENTLY EXISTS TODAY. 2. ANY MISSING OR DEAD SHRUBS SHALL BE REPLACED WITH THE SAME SPECIES SHRUB THAT IS A MINIMUM OF Z IN HEIGHT WHEN MEASURED IMMEDIATELY AFTER PLANTING, AND 3HIGH 1 YEAR AFTER TIME OF PLANTING. HEDGES, WHERE INSTALLED, SHALL BE PLANTED AND MAINTAINED TO FORM A CONTINUOUS, UNBROKEN, SOLID, VISUAL SCREEN 3HIGH WITHIN 1 YEAR OF PLANTING. 3. ANY MISSING OR DEAD TREES SHALL BE REPLACED WITH THE SAME SPECIES AND SHALL BE A MINIMUM 3" CALIPER 6" ABOVE GRADE. 4. ALL REQUIREMENTS OF THEE CITY OF GRAPEVINE SOIL EROSION ORDINANCE SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. 0' 10, 30' GRAPHIC SCALE I � I 1 BRADFORD PEAR { r,. �,i 1 Ill!' Littrtr Lv,;vL _ 2 nerE I Ij f3�tU[t�ANC;E �4, •••� 1 L LIVE OAK L LIVE OAK -- MAEsONRY SCREEN WALL I 1 VARIES IN HEIGHT FROM I I 9m Tr'1 Ad" Al HIrH RI IRFnRil LIVE OAK ARCHITECT: TMA-CHA ARCHITECTS 814 PENNSYLVANIA AVE. FORT WORTH, TEXAS 76104 JOHN REESER PROJECT ARCHITECT 817-737-0404 JOHN@TMA-CHA.COM OWNER: DR. NATHAN GRAVES 1601 LANCASTER DRIVE GRAPEVINE, TEXAS 76051 817-481-7727 9], 70' SCALE: 1 " = 20'-0" L4 COLLEGE ST o SITE or.FoaD LN m cl) Ul Z D g p EATON LN m Lu J Y w6U[)GINS 5T 1RAt��-1 ODS NORTH V I C I N I T TY MAP CASE NAME: NEXTMED CASE NUMBER: SP22-11 LOCATION: 1601 LANCASTER DRIVE MAYOR SECRETARY DATE: PLANNING AND ZONING COMMISSION CHAIRMAN DATE: SHEET- OF APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES PLANNING SERVICES DEPARTMENT 110, EXISTING LANDSCAPE PLAN FOR NEXTMED ASC LOT 1 R, BLOCK 3, CLEARVIEW PARK CITY OF GRAPEVINE, TARRANT COUNTY, TEXAS 1.789 ACRES ZONE: P-O PROFESSIONAL OFFICE DISTRICT DATE OF PREPARATION: DECEMBER 12, 2022 U cf) w Ir < U) ° �W z0 LLJw W W �> o� zW 2 � gQ Ir X o0 W T G 12/ 14/2022 PDF REPRODUCTION CONTROL: l_.-' 0 1" SQUARE WHEN PRINTED FULL SIZE DRAWING TITLE: EXISTING LANDSCAPE PLAN DATE: 14 DEC 2022 DRAWN BY: TMA PROJECT NO. 2027 SUBMITTAL: 1. 2. 3. Ll ol ■ SP22-11.1 1 Email a PDF of the revised plans by Tuesday, November 1, 2022 at 12:00 p.m. to emarohnic@grapevinetexas.gov/atriplett@grapveinetexas.gov/mzahir@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. PROJECT DESCRIPTION: SP22-07; 216 & 306 East Northwest Highway– submitted by Ridinger Associates, Inc for property located at 216 East Northwest Highway and 306 East Northwest Highway, proposed to be platted as Block 1, Lot 1, 430 Main Addition. The applicant has submitted a site plan application to specifically to allow for a multi-tenant office and retail development. The property is currently zoned “HC”, Highway Commercial District and owned by Wright 430 Main, LCC. PLANNING SERVICES All Sheets: 1. Ensure that within the approval block (2nd example) that it reads, “Planning Services Department.” The title block must be in the lower-right hand corner of the sheet. The approval block must be located near the title block (e.g., above or to the left of the title block). • Review and revise the following notes in regard to the signature block o Case Name: NextMed o Case Number: SP22-11 o Location 1601 Lancaster Drive 2. Include a vicinity map, written and graphic scale and north arrow, vicinity nearby to one another. 3. Add the owners name, address, and phone number. 4. Add the name, address, number, and email address of the person preparing the plans. 5. Ensure that north is at the top of all pages. Review and revise to reorient drawings accordingly. SP22-11 OCTOBER 25, 2022 1601 LANCASTER DRIVE BLOCK 3, LOT 1R, CLEARVIEW PARK ADDITION Site Plan/Landscape Plan/Photometric Plan/Façade Plan (example) for The Grapevine Brownstones Lot X-Y, Block X, SUBDIVISION NAME Ab. No. ZZZ City of Grapevine, Tarrant County, Texas X.X acres or XX sq. ft. Zone: “LI” Light Industrial, proposed Transit District Overlay Date of Preparation: January 17, 2022 (or subsequent date or revision) SP22-11.1 2 Dimensional Control Site Plan – Sheet #1 of 2 1. Address all comments found under All Sheets above. 2. Provide a site data summary table on the site plan sheet, utilize the table format link provided. Provide total open space and impervious area in square feet and percentages. 3. Label on plan drawing over existing building: total building height in stories and feet, and total building area 4. Label on plan drawing over existing lot: total lot area; subdivision name, lot and block; and address. 5. Label and dimension width of existing fire lane. 6. Label and dimension the width of the two existing drives adjacent to Lancaster Drive. 7. Dimension typical parking space and handicap accessible parking space. 8. Dimension existing solid waste enclosure. State enclosure type (e.g., materials) and enclosure height in feet. 9. Show and label the location, size and arrangement of all outdoor signs (pole signs, wall signs, and ground signs), the location and intensity of all outdoor lighting, and exterior lighting. Dimension any signs to the nearest property line. 10. Include an internal traffic circulation pattern with the use of arrows. 11. Label and show the existing carport cover to the north of the existing building. 12. Remove clouds around the bearing and distances. 13. Remove cloud and note over the north side of the parking lot. 14. Remove greyed area to denote existing building. Use blackline drawing only. 15. Review and revise entrance canopy for label to red “Existing Entrance Canopy” rather than exist. 16. Dimension existing entrance canopy to the east property line. 17. Show and label building setbacks adjacent to all property lines. 18. Ensure that all labels stating exist are revised to read existing. Number parking count for rows/a series of parking spaces over the site plan drawing. 19. Remove all clouded areas as the site plan is busy and utilize symbols and a legend to clean up site plan drawing. 20. Remove triangle symbols used to denote date of revisions from the site plan drawing, also remove the legend from the bottom right hand corner of the page. 21. Dimension the generator screening device to the east property line. 22. Dimension existing building to the adjacent property lines. 23. Include zoning, and lot and block information for the adjacent properties to the east and south. Show lot layout of residences adjacent to the east property line as shown on the attached plat. Include lots highlighted on the plat. 24. Remove enclosure elevations and fence details from the site plan sheet and provide on a separate sheet or on the requested building elevations sheet. 25. Remove clouded legal description below the site plan drawing. 26. Include the following table in regard to performance standards on the site plan drawing SP22-11.1 3 27. Label Lancaster Drive and West College Street on the site plan drawing 28. Show and label existing and proposed utilities. 29. Show and label entrance gate island. Landscape Plan – Sheet # 4 of 6 1. Address all comments found under All Sheets above. 2. Provide an original up to date landscape plan drawing consistent with Section 53. Landscaping Regulations. Ensure that all plans are signed and sealed including the landscape plan. 3. Provide a data summary table on the plan sheet, utilize the table format link provided. 4. Add the following standard notes: 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. 2. All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction. 5. Ensure that any missing or dead trees (minimum 3-inch caliper) and shrubs are included/ replaced. 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting and three (3) feet high within one (1) year after time of planting. Building Elevations – Not provided 1. Address all comments found under All Sheets above. 2. Provide building elevations on all four sides as label as north, east, south, and west. 3. Include a table with percentages of building of masonry exclusive of doors and windows. 4. Include an elevation of the trash enclosure with height and materials noted. 5. Include elevations of the generator screening enclosure and fence detail as shown on the site plan. Remove these details from the site plan. Grading, Drainage– Not Provided 1. Address all comments found under All Sheets heading above. 2. Provide a grading/drainage plan as one was not provided. Also, submit this sheet to public works. PUBLIC WORKS Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil Engineer at 817.410.3136 for the following comments: 1. Provide a grading and drainage plan to Public Works. SP22-11.1 4 BUILDING SERVICES Contact Larry Gray – Assistant Building Official at 817.410.3165 or lgray@grapevinetexas.gov to discuss the following: 1. No Comment FIRE MARSHALL Contact Bryan Parker - Fire Marshal at 817.410.4420 or bparker@grapevinetexas.gov for the following comments: 1. No Comment PARKS Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or knelson@grapevinetexas.gov to discuss the following: 1. No Comment ____________________________________________________________________ Email a PDF of the revised final plans by Tuesday, November 1, 2022 at 12:00 p.m. to emarohnic@grapevinetexas.gov/atriplett@grapveinetexas.gov/mzahir@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. Please direct all questions to Marium Zahir and/or Albert Triplett at (817) 410-3155. SP22-11.1bb 1 Email a PDF of the revised plans by Tuesday, January 3, 2023 at 12:00 p.m. to emarohnic@grapevinetexas.gov, atriplett@grapveinetexas.gov, and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. PROJECT DESCRIPTION: SP22-07; 216 & 306 East Northwest Highway– submitted by Ridinger Associates, Inc for property located at 216 East Northwest Highway and 306 East Northwest Highway, proposed to be platted as Block 1, Lot 1, 430 Main Addition. The applicant has submitted a site plan application to specifically to allow for a multi-tenant office and retail development. The property is currently zoned “HC”, Highway Commercial District and owned by Wright 430 Main, LCC. PLANNING SERVICES All Sheets: 1. ADDRESSED. Ensure that within the approval block (2nd example) that it reads, “Planning Services Department.” The title block must be in the lower-right hand corner of the sheet. The approval block must be located near the title block (e.g., above or to the left of the title block). • Review and revise the following notes in regard to the signature block o Case Name: NextMed o Case Number: SP22-11 o Location 1601 Lancaster Drive 2. ADDRESSED. Include a vicinity map, written and graphic scale and north arrow, vicinity nearby to one another. 3. ADDRESSED. Add the owners name, address, and phone number. 4. ADDRESSED. Add the name, address, number, and email address of the person preparing the plans. 5. ADDRESSED. Ensure that north is at the top of all pages. Review and revise to reorient drawings accordingly. SP22-11 DECEMBER 21, 2022 1601 LANCASTER DRIVE BLOCK 3, LOT 1R, CLEARVIEW PARK ADDITION Site Plan/Landscape Plan/Photometric Plan/Façade Plan (example) for The Grapevine Brownstones Lot X-Y, Block X, SUBDIVISION NAME Ab. No. ZZZ City of Grapevine, Tarrant County, Texas X.X acres or XX sq. ft. Zone: “LI” Light Industrial, proposed Transit District Overlay Date of Preparation: January 17, 2022 (or subsequent date or revision) SP22-11.1bb 2 Dimensional Control Site Plan – Sheet #1 of 2 1. ADDRESSED. Address all comments found under All Sheets above. 2. ADDRESSED. Provide a site data summary table on the site plan sheet, utilize the table format link provided. Provide total open space and impervious area in square feet and percentages. 3. ADDRESSED. Label on plan drawing over existing building: total building height in stories and feet, and total building area 4. ADDRESSED. Label on plan drawing over existing lot: total lot area; subdivision name, lot and block; and address. 5. ADDRESSED. Label and dimension width of existing fire lane. 6. ADDRESSED. Label and dimension the width of the two existing drives adjacent to Lancaster Drive. 7. ADDRESSED. Dimension typical parking space and handicap accessible parking space. 8. ADDRESSED. Dimension existing solid waste enclosure. State enclosure type (e.g., materials) and enclosure height in feet. 9. ADDRESSED. Show and label the location, size and arrangement of all outdoor signs (pole signs, wall signs, and ground signs), the location and intensity of all outdoor lighting, and exterior lighting. Dimension any signs to the nearest property line. 10. ADDRESSED. Include an internal traffic circulation pattern with the use of arrows. 11. ADDRESSED. Label and show the existing carport cover to the north of the existing building. 12. ADDRESSED. Remove clouds around the bearing and distances. 13. ADDRESSED. Remove cloud and note over the north side of the parking lot. 14. ADDRESSED. Remove greyed area to denote existing building. Use blackline drawing only. 15. ADDRESSED. Review and revise entrance canopy for label to red “Existing Entrance Canopy” rather than exist. 16. ADDRESSED. Dimension existing entrance canopy to the east property line. 17. ADDRESSED. Show and label building setbacks adjacent to all property lines. 18. ADDRESSED. Ensure that all labels stating exist are revised to read existing. ADDRESSED. Number parking count for rows/a series of parking spaces over the site plan drawing. 19. ADDRESSED. Remove all clouded areas as the site plan is busy and utilize symbols and a legend to clean up site plan drawing. 20. ADDRESSED. Remove triangle symbols used to denote date of revisions from the site plan drawing, also remove the legend from the bottom right hand corner of the page. 21. ADDRESSED. Dimension the generator screening device to the east property line. 22. ADDRESSED. Dimension existing building to the adjacent property lines. 23. ADDRESSED. Include zoning, and lot and block information for the adjacent properties to the east and south. Show lot layout of residences adjacent to the east property line as shown on the attached plat. Include lots highlighted on the plat. 24. ADDRESSED. Remove enclosure elevations and fence details from the site plan sheet and provide on a separate sheet or on the requested building elevations sheet. 25. ADDRESSED. Remove clouded legal description below the site plan drawing. 26. ADDRESSED. Include the following table in regard to performance standards on the site plan drawing SP22-11.1bb 3 27. ADDRESSED. Label Lancaster Drive and West College Street on the site plan drawing 28. ADDRESSED. Show and label existing and proposed utilities. 29. ADDRESSED. Show and label entrance gate island. Landscape Plan – Sheet # 4 of 6 1. ADDRESSED. Address all comments found under All Sheets above. 2. ADDRESSED. Provide an original up to date landscape plan drawing consistent with Section 53. Landscaping Regulations. Ensure that all plans are signed and sealed including the landscape plan. 3. ADDRESSED. Provide a data summary table on the plan sheet, utilize the table format link provided. 4. ADDRESSED. Add the following standard notes: 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting. Hedges, where installed, shall be planted and maintained to form a continuous, unbroken, solid, visual screen which will be three (3) feet high within one (1) year after time of planting. 2. All requirements of the City of Grapevine soil erosion control ordinance shall be met during the period of construction. 5. ADDRESSED. Ensure that any missing or dead trees (minimum 3-inch caliper) and shrubs are included/ replaced. 1. Shrubs shall be a minimum of two (2) feet in height when measured immediately after planting and three (3) feet high within one (1) year after time of planting. Building Elevations – Not provided 1. ADDRESSED. Address all comments found under All Sheets above. 2. ADDRESSED. Provide building elevations on all four sides as label as north, east, south, and west. 3. ADDRESSED. Include a table with percentages of building of masonry exclusive of doors and windows. 4. ADDRESSED. Include an elevation of the trash enclosure with height and materials noted. 5. ADDRESSED. Include elevations of the generator screening enclosure and fence detail as shown on the site plan. Remove these details from the site plan. Grading, Drainage– Not Provided 1. ADDRESSED. Address all comments found under All Sheets heading above. 2. ADDRESSED. Provide a grading/drainage plan as one was not provided. Also, submit this sheet to public works. SP22-11.1bb 4 PUBLIC WORKS Contact Paul Lee - Civil Engineer, Elizabeth Reynold EIT or Cristin Turner (Platting) – Civil Engineer at 817.410.3136 for the following comments: 1. PENDING. Provide a grading and drainage plan to Public Works. 2. NEW COMMENT. A Utility Plan (Sheet C1) was submitted which depicts four new water taps in a configuration that is not acceptable to the Public Works Department and Fire Marshall’s office. Refer to the attached markup, “Engineering Markup of Requested Water Taps 12.21.22.” Reach out to Elizabeth Reynolds directly to discuss. BUILDING SERVICES Contact Larry Gray – Assistant Building Official at 817.410.3165 or lgray@grapevinetexas.gov to discuss the following: 1. No Comment FIRE MARSHALL Contact Bryan Parker - Fire Marshal at 817.410.4420 or bparker@grapevinetexas.gov for the following comments: 1. NEW COMMENT. A Utility Plan (Sheet C1) was submitted which depicts four new water taps in a configuration that is not acceptable to the Public Works Department and Fire Marshall’s office. Refer to the attached markup, “Engineering Markup of Requested Water Taps 12.21.22.” Reach out to Bryan Parker directly to discuss. PARKS Contact Kathy Nelson – Capital Improvements Program Manager at 817.410.3394 or knelson@grapevinetexas.gov to discuss the following: 1. No Comment ____________________________________________________________________ Email a PDF of the revised final plans by Tuesday, January 3, 2023 at 12:00 p.m. to emarohnic@grapevinetexas.gov, atriplett@grapveinetexas.gov, and nlgale@grapevinetexas.gov. Verify that all text is legible on an 11”x 17” sheet. Do not reproduce final copies requested below prior to Planning Staff approval. Please direct all questions to Natasha Gale and/or Albert Triplett at (817) 410-3155.