HomeMy WebLinkAboutF211334-1053866Detail Sheet:• Plan Sheet: Grapevine, Texas SY1.1, Reinforcing Drawing RF20 Not Correct Reinforcement Clean Form Clean Item Observed Correct Grade Reinforcement Number of Reinforcement N/A 11/22/21, 01/07/22, 11/23/2021 X X Size of Reinforcement N/A •Date: X X X Stirrup Spacing Not Correct Proper Placement Reinforcement Tied Properly X X 1 of 3 Clear 6/1/2022 Off Champagne Boulevard and Merlot Avenue F211334 Technician:Thompson, Bryan Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Retaining Wall: Around Building and Smokehouse The representative utilized the following provided project plans to perform the observation: Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written X approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Drawings Approved Observation Information X X SP1.0, Reinforcing Drawing RF18 05/27/2022Service Date:Client:Chicken N Pickle 104 Armour Road North Kansas City, MO 64116 Work Order Number: Project Number: Report Date: Weather: Chicken N Pickle Grapevine 1053866 Project: Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Reinforcing Steel Observation Report • • Page Number: The representative observed the reinforcing steel related items for the following area: An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. Item Observed Bar Length & Spacing Correct X X Respectfully Submitted, Remarks: Paul Delaney X Sheathing X X The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. Proper Cover Proper Support Dowels in Place Stirrup Size X Grade Beam / Column Size Based on the representative's visual observation using the provided project plans, the area was compliant X PT Drawings X Cable/Tendon Count & Spacing X Cable/Tendon Drape X Correct Splicing Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Reinforcing Steel Observation Report Client:Chicken N Pickle Service Date:05/27/2022 Work Order Number: 1053866 Project:Chicken N Pickle Grapevine Project Number:F211334 104 Armour Road Report Date:6/1/2022 North Kansas City, MO 64116 Weather:Clear An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. The representative observed the reinforcing steel related items for the following area: • Pier Footer Shelters Off Champagne Boulevard and Merlot Avenue Technician:Thompson, Bryan Grapevine, Texas Page Number:2 of 3 •Plan Sheet:SP1.0, Reinforcing Drawing RF 18 •Detail Sheet:SS1.1, Reinforcing Drawing RF20 The representative utilized the following provided project plans to perform the observation: •Date:11/21/21, 01/07/22, 11/23/2021 Observation Information Item Observed Correct Not Correct N/A Item Observed Correct Not Correct N/A Drawings Approved X Proper Cover X Grade Reinforcement X Reinforcement Clean X Size of Reinforcement X Proper Support X Bar Length & Spacing X Dowels in Place X Number of Reinforcement X Form Clean X X Reinforcement Tied Properly X Stirrup Spacing X Proper Placement X Stirrup Size X PT Drawings X Cable/Tendon Count & Spacing X Correct Splicing X Grade Beam / Column Size The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. Remarks: X Based on the representative's visual observation using the provided project plans, the area was compliant Cable/Tendon Drape X Sheathing Respectfully Submitted, Paul Delaney Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Alpha Testing, LLC 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Reinforcing Steel Observation Report Client:Chicken N Pickle Service Date:05/27/2022 Work Order Number: 1053866 Project:Chicken N Pickle Grapevine Project Number:F211334 104 Armour Road Report Date:6/1/2022 North Kansas City, MO 64116 Weather:Clear An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. The representative observed the reinforcing steel related items for the following areas: • Footers: Smokehouse Off Champagne Boulevard and Merlot Avenue Technician:Thompson, Bryan Grapevine, Texas Page Number:3 of 3 •Plan Sheet:SP 1.0, Reinforcing Drawing RF 18 •Detail Sheet:SY1.1, Reinforcing Drawing RF20 • Grade Beam The representative utilized the following provided project plans to perform the observation: •Date:11/23/21, 01/07/22, 11/23/21 Observation Information Item Observed Correct Not Correct N/A Item Observed Correct Not Correct N/A Drawings Approved X Proper Cover X Grade Reinforcement X Reinforcement Clean X Size of Reinforcement X Proper Support X Bar Length & Spacing X Dowels in Place X Number of Reinforcement X Form Clean X Reinforcement Tied Properly X Stirrup Spacing X Proper Placement X Stirrup Size X PT Drawings X Cable/Tendon Count & Spacing X Correct Splicing X Grade Beam / Column Size X The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. Remarks: X Based on the representative's visual observation using the provided project plans, the area was compliant Cable/Tendon Drape X Sheathing Respectfully Submitted, Paul Delaney Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering