Loading...
HomeMy WebLinkAboutF211334-1071656,1071656,1071656,1071656Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1071656-S1 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:7/5/2022 Time Placed:3:15 AM 2.50 3.0 85 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Webb, Jason Plant Number:506 Delivery Ticket No.:50924936 146.8 Batch Time:2:26:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:100'W AND 10' S FROM THE EXT ROADWAY PM:PAUL DELANEY Date Issued:07/13/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 210 7/12/2022 7 3895012.56 3100LABC-1231 8.00 N/A 4.003 211 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 212 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 213 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 214 8/30/2022 56 012.56LABC-1231 8.00 N/A 4.00 CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 491431 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 1 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1071656-S2 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:7/5/2022 Time Placed:4:30 AM 6.00 1.5 83 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Webb, Jason Plant Number:506 Delivery Ticket No.:50924979 145.4 Batch Time:3:29:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:100'W AND 50'S FROM THE EXT ROADWAY PM:PAUL DELANEY Date Issued:07/13/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 215 7/12/2022 7 4249012.56 3380LABC-1231 8.00 N/A 4.002 216 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 217 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 218 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 219 8/30/2022 56 012.56LABC-1231 8.00 N/A 4.00 CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 491432 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 2 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: PARKING LOT Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1071656-S3 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:7/5/2022 Time Placed:5:30 AM 6.00 3.5 81 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Webb, Jason Plant Number:506 Delivery Ticket No.:50925046 146 Batch Time:4:40:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:100'W AND 100'S FROM THE EXT ROADWAY PM:PAUL DELANEY Date Issued:07/13/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 220 7/12/2022 7 4534012.56 3610LABC-1231 8.00 N/A 4.003 221 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 222 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 223 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 224 8/30/2022 56 012.56LABC-1231 8.00 N/A 4.00 CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 491434 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 3 of 4 Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, LLC TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: FIRELANE Project Desc:CHICKEN N PICKLE GRAPEVINE OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE Our Report #:F211334-1071656-S4 CHICKEN N PICKLE 104 ARMOUR ROAD NORTH KANSAS CITY, MO 64116 ALEX STEHLATTN: Date Placed:7/5/2022 Time Placed:8:00 AM 3.50 5.5 82 90 Date Received:N/A Concrete Supplier:BURNCO Submitted By:Webb, Jason Plant Number:508 Delivery Ticket No.:50925174 145.9 Batch Time:7:20:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:30U500BG Break Type: Sample Location:20'W AND 150' S FROM EXSTING ROADWAY PM:PAUL DELANEY Date Issued:07/13/2022 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): Weather: Wind: Clear Initial Curing Method:Protected Area, Covered with Lid Final Curing Method:Moist Room 225 7/12/2022 7 3782012.56 3010LABC-1231 8.00 N/A 4.003 226 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 227 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 228 8/2/2022 28 012.56LABC-1231 8.00 N/A 4.00 229 8/30/2022 56 012.56LABC-1231 8.00 N/A 4.00 CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 491435 Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. This report shall not be reproduced except in full, without the prior written approval of Alpha Testing. Page 4 of 4