HomeMy WebLinkAboutF211334-1076107Concrete Compression Test
Report
5058 Brush Creek Rd.
Fort Worth, TX 76119
(817)496-5600
Alpha Testing, LLC
TBPE Firm No. 813
FIELD DATA
Placement Location:PAVING: SECOND APPROACH
Project Desc:CHICKEN N PICKLE GRAPEVINE
OFF CHAMPAGNE BOULEVARD AND MERLOT AVENUE
Our Report #:F211334-1076107-S2
CHICKEN N PICKLE
104 ARMOUR ROAD
NORTH KANSAS CITY, MO 64116
ALEX STEHLATTN:
Date Placed:7/12/2022
Time Placed:6:45 AM
5.00
4.6
80
87
Date Received:N/A
Concrete Supplier:BURNCO
Submitted By:Thompson, Bryan
Plant Number:508
Delivery Ticket No.:50927485
144
Batch Time:5:45:00 AM
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
(ASTM C-231)
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Cast By:ALPHA
Cured Specification:ASTM C-31
Mix ID:4OU500BG
Break
Type:
Sample Location:10'N AND 4' W OF MERLOT AVE
PM:PAUL DELANEY
Date Issued:09/06/2022
Specified Strength:4000
Result
Air Content:
Ambient Temp (F):
Concrete Temp (F):
Unit Weight:
Slump (ASTM C-143):
Weather:
Wind:
N/A
Initial Curing Method:Protected Area, Covered with Lid
Final Curing Method:Moist Room
235 7/19/2022 7 3719012.56 2960LABC-1231 8.00 N/A 4.002
236 8/9/2022 28 4827012.56 3840LABC-1231 8.00 N/A 4.002
237 8/9/2022 28 4657012.56 3710LABC-1231 8.00 N/A 4.002
238 8/9/2022 28 4972012.56 3960LABC-1231 8.00 N/A 4.002
239 9/6/2022 56 5780012.56 4600LABC-1231 8.00 N/A 4.002
CC:
3840
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, LLC
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 492286
Break Types: 1: Cone 2: Cone and Split 3: Columnar 4: Diagonal 5: Single Sided Fracture 6: Double Sided Fracture * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.
Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.
This report shall not be reproduced except in full, without the prior written approval of Alpha Testing.
Page 1 of 1